Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹43.7 LAccepted-AOC HOUSE NO 129 BASISTHA ROAD BASISTHA CHARIALI PO BASISTHA GUWAHATI 781029 ASSAM | KAMRUP METRO | ASSAM | 781029 | 1 | Accepted-AOC L1 | |
| 2 | 2₹46.0 L+₹2.3 L (5.34%)Rejected-Finance OPP BSF GATE NO 3 AZARA GUWAHATI 17 ASSAM | 2 | Rejected-Finance OTHER THAN L1 | |
| 3 | 3₹49.4 L+₹5.7 L (13.0%)Rejected-Finance | 3 | Rejected-Finance OTHER THAN L1 | |
| 4 | 4₹52.5 L+₹8.8 L (20.1%)Rejected-Finance | 4 | Rejected-Finance OTHER THAN L1 | |
| 5 | 5₹54.3 L+₹10.6 L (24.3%)Rejected-Finance | 5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
17 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE SHILLONG
HQ CWE SHILLONG SE FALLS SHILLONG MEGHALAYA - 793 011
PROVISION OF WEIGH BRIDGE AT 313 COY ASC SUP TYPE F UNDER GE NARANGI
2021_MES_427988_2
8457/NAR/E8
Open Tender
Civil Works
Lump-sum
240 days
NARANGI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE NARANGI
₹93,000
Yes
13 May 2021
3 Apr 2021
19 Apr 2021
3 Apr 2021
17 Apr 2021
3 Apr 2021
60 days
Amount
Total Amount of Sch 'A' Part-I (Buildings/Structures Work) Prepriced
Total Amount of Sch 'A' Part - II (Internal Electrification) Prepriced
Total amount of Sch 'A' Part - III (External Electrification) Prepriced
Total amount of Sch 'A' Part IV (Approach Road/ Hardstanding) Prepriced
Sch 'A' Part - V (Miscellaneous B/R & E/M Items) Note - This Schedule (item No 6 to 19) has not been pre-priced by MES and the estimated rate not indicated in col.5 siginifies this fact only.
Supply, Installation, testing, calibration & commissioning of PIT less type PC based electronic weigh bridge of capacity of 40 MT, double ended sher beam load cell having steel frame work platform of size 12m x 3m size having least count 10 kg, Desktop with printer and online UPS of capacity 1 KVA including necessary foundation as per drawing given by OEM comprising of following:- (a) Load Cell: OIML approved double ended shear beam load cell made of nickel plated alloy steel, hermetically sealed IP-68 protection, rated outpur 2 mv/V, error should be with + 02% safely loaded upto 150% of rated capacity and having ultimate over load capacity 300% of rated capacity. (b) Weigh bridge Indicator: Stainless Steel enclosure having 6 digit, 20mm red LED display, IP-67, operated with 100-280 VAC/24 power supply having the following features:- (i) 24 bit A/D convertor with 200 samples/sec. (ii) RS 232 & RS 485 communication port with MODBUS protocol, (iii) Clearly labelled tactile keys. (c) Weigh bridge steel structure: The structure to be manufactured using closed orthotropc section U beams, each module should be seal welded including top plate, side plates of size 12m x 3m fabricated with specific grade HT steel plates and having factor of safety (FOS) >1.5 and duly painted with anti corrosive eppoxy paints.
(d) Desktop: Desktop with 24" LED 4K display monitor having intel 8th generation quardcore 17 processor, Hard disk of capacity 1 TB with 16 GB RAM including mouse and keyboard. Make: HP/Dell/ Apple or its equivalent Make as approved by Accepting Officer, (e) Printer: Single function monochrome printer operating voltage 220 to 240 VAC (+/- 10%), 50/60 Hz (+/- 2 Hz) with i7 compatible including all accessories. Make: HP Model: Laserjet Pro M403n or its equivalent Make and Model as approved by Acceoting Officer. (f) UPS: UPS of rating 1 KVA with input voltage single phase 160V - 260V sinewave, 50 Hz and output voltage single phase 230V +/- 1% sinewave 50 Hz, Backup time 60 min having protection of over voltage, short circuit & over load at UPS output terminal and incorporated with metering and indications for AC input voltage, output AC voltage. Current frequency, battery voltage and current all as specified and directed. Make: Aplab or APC or its equivalent as approved by Accepting Officer.
Note: - (i) The contractor shall submit the test certificate and calibration report from manufacturer, (ii) Operating system of desktop shall be Windows 7 or higher version & 17 processor with 64 bit license version, (iii) Standard weights as per W&M Act and for calibration to be arrange by contractor, (iv) Cost of cable for interconnection between load cell to junction box & junction box to indicator including GI conduit of adequate size deemed to be included in quoted rate, (v) PC based weighing transaction software shoule be as per OEM, (vi) Cost of excavation, removing, returning filling, PCC work for foundation work as per OEM design all as shown and specified in drawings (Sheet No 1/3 to 3/3) deemed to be included in the quoted rate.
M&L for Advance encapsultated compound based Chemical earthing CPRI tested maintenance free, pipein-pipe technology upgraded (Zinc & Alloy coated), Zinc & Alloy coated (80-100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2mm and 41.9mm dia respectively of 3 mtrs long zinc coated with additional special alloy coating 300mm on top side for additional protection of the terminal. The annular space between the pipe to be filled up with compact fill (CF) (Crystalline Conductive) mixture which should be machine preseed in the pipes not disintegrate or collapse when outer pipe corrodes. the inner pipe should be extended with terminals for connectivity. The job includes digging the pits, lowering the pipe in pipe earth electrode, filling of pure and conductolite back fitting compound (BFC Conductolite) having excellent moisutre retaining capacity in 250mm around friendly it should not contain environmentally hazardous material/metal having ROHS certification from NABL accredited lab. The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrode should have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M&L for in PCC (1:3:6) type C-1 around the FRP fover for support and foundation and colouring the PCC work with desired colour complete all as specified and directed. Make: ASHLOK (Model ASEEL-39AC 3 mtr length 76.3 mm dia or its equivalent as approved by Accepting Officer. NOTE: - (i) Design of earth electrode should be pipein-pipe technology, (ii) Contractor have to submit literature of earth electrode and get the make approved by GE before procurement, (iii) The earth electrode shall be CPRI tested to withstand short current test for 60 KA rms for 1.0 second and 150KA for peak current, (iv) Contractor has to fill pure back fill compound 250mm all around the earth.
Supply, Installatio/fixing, testing commissioning of Air Conditioner unit, invertor (Variable speed) of 1.5 TR capacity (Split Type unit comprising of indoor and outdoor unit) electric driven (Single phase 230 volt, 50 Hz) and with inbuilt air ioniser and plasma filter for better indoor air quality with BEE 5 star rating, including necessary fixing arrangment complete (indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) including metalic bracket with fixing bolts for outdoor unit, insulated piping etc, all as directed by Engr-in-charge. NOTE: - (i) Airconditioner shall be initial filled / charged with refrigerant of specified quantity, (ii) Additional refrigerant pipes as required from ourter unit to indoor unit on site deemed to be included in AC rate (iii) Suitable piping shall be provided of adequate length of size 5/8" for draining of condensate water from indoor unit, (iv) Split type AC unit to supplied with cordless remote control for operation.
Supply and Installation of voltage stabilizer wall mounting, copper wound, Built in Thermal Overload protection, digital automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 270V with output voltage stabilised at 220 volt with accuracy of +/- 3% of capacity 12 Amps all as specified and directed. Make: V Guard Model VG 400 or equivalent make and model of Sen & Pandit/ Microtek
S&F energy efficient ceiling fan BEE 5 star rated complete all accessories 230V, 1200mm sweep complete including proper hanging arrangement
S&F LED 20 watt tube light fitting (T8 type) single end connection type LED retrofit tube lamp 20W, 240 volts, PF > 0.90, colour Temp 6500K, system Luminous efficacy > 100 Lm/W, complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core and PVC round/square box white coloure x 2 Nos for mounting of fitting complete all as specifed and directed.
S&F inr repair LED bulkhead light of 10W with pressure die cast housing along with polycarbonite diffuser and LED's IP-65 protection of watt, PF>0.95 complete all as specified and directed by Engineer-in-Charge
S&F die cast alumnium housing with fron toughened glass type LED flood light luminarie (Luminous efficancy 120 lumen/watt) of 50W with all accessories including necessary electrical connections by three core sheathed alumnium/copper conductor cable of suitable sizes specified location all as directed and specified by Engr-in-Charge including down unserviceable one. NOTE: (i) MS clamp, Nut, Bolt & Washers or any modifications reqd for fixing the luminaries in the existing pole the rates for the sare deemed to be included in this rate. Make: Baja Mode No: BJFL 50W LED or equivalent in Havells / Philips.
S&F sheet metal enclosure for VT TPN 4 way (with MCCB as INCOMER), double door with 63 Amps, 25 KA, FP MCB as incomer (MCCB rate inclusive) including fixing the DB box flush in wall of any type and making good the distributed surface to match as the existing complete all as specified and directed by Engr-in-Charge
S&F of MCB DP 240 volts, 6-32 Amps, 10 KA, `C' series complete all as specified and directed.
S&F MCB SP 6 to 32 A, 240V, 50Hz, `C' series breaking capacity 10KA all as specified and directed.
S&F Type 1 = 2 AC surge protection decive TP + N Uc = 320V, In=20KA and Imax = 50KA in existing DBs all as specified and directed by Engr-in-Charge
Supply, Installation, testing and commissioning silet, AC Diesel Engine driven generating set of capacity 15 KVA, 12 KW at 0.8 PF (lag) 415 volts, 3 phase 4 wire at 1500 RPM engine IS: 10001/10002 (as per OEM design), and Alternator as per IS: 13364 mounted on common base frame complete with control panel, fuel tank, battery & leads, Canopized, Residential silencer, AVM pads and first fill of Lube oil & Accoustic enclosure exhaust pipe complete including PCC foundation of suitable size as per manufacturers recommendation including all features to comply with latest CPCB II guidelines and comprising of following: - Note: - The cost of all the materials required for testing of DG set to be included in the quoted rate. (a) Diesel Engine 21 bhp, 1500 RPM, multi cylinder, four stroke,confirming to IS03046, radiator cooled, diesel engine developing the rated power continuously while running at 1500 RPM as per BS: 5514 under NTP conditions. The engine is capable of taking an overload of 10% intermittenly for one hour in every 12 hours of operation as per provisions of BS:5514 and will be complete with the following: (i) Electrical starter motor 12 V DC with soft start engagement feature, (ii) Battery charging alternator, (iii) Inline fuel pump with A1 class Mechanical governor, (iv) Splin - On Fuel filter, (v) Full flow spin on lube oin filter, (vi) 1 x 12 V DC battery, (vii) Dry type, Replaceable paper element air cleaner with restriction indicator, (viii) Air to air after cooling, (ix) Flywheel & Flywheel housing, (x) First fill of lube oil and coolant.
(b) Alternator of 15 KVA stamford make, suitable for continuous operation at 1500 RPM, 415 volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire system conforming to BS 5000/IS 4722. The Alternator is brush less type, screen protected, revolving field, self excited, Class H insulation, self regulated through an AVR. The alternator having the following features:- (i) + 1.0 % voltage regulation (max) in static conditions, (ii) IP: 23 enclosure, (iii), It is capable of taking an overload of 10% intermittently for 1 Hour in every 12 hours of operation. Make of Diesel Engine & Alternator:- Kirloskar / Cummins / Jakson Power / Mahindra
(c) CONTROL PANEL:- The genset control panel is manufactured with 14/16 gauges CRCA sheet and power coated for a whether proof, long lasting finish. Control panel consist of following parts: - (i) Standrard Engine Instrumentation, (ii) PS0600 controller with AMF functionally, (iii) Circuit brakers of suitable rating with overload and short circuit protection, (iv) Push button (Starter), (v) LED indications for main functions, (vi) Instrument fuses duly wired and ferruled.
(d) MOUNTING ARRANGEMENT: - Engine and Alternator are mounted on a common MS fabricated base frame with ACM pades, Base frame with integral fuel tank of adequate capacity is provided with drain plug, air vent, inlet and outlet connection, level indicator and having provision of cleaning
Supply, Install testing, commissioning CPRI approved LT feeder pillar box of suitable size (leg of three feeder pillar should not less than 600mm length) out door type made out of 3.15 mm thick CRCA sheet supported and fixed on structural frame, factory made duly fixed on the ground by PCC foundation (1:2:4 type B-1) of size 700mm x 300mm x 600mm on the adjacent pairs of legs & net cementing the same. The feeder pillar box should duly painted with two coats of enamel paint over a coat of red oxide primer (Internally & Externally) on the surface all as specifed and directed by Engr - in - Charge. The feeder pillar box is cubicle shaped, roof canopy type, with special type of heavy duty industrial door hinges and totally enclosed dust proof and vermin proof front and back opening with locking arrangements. The box should have provision / accommodation of the following electrical items
INCOMING: (i) Alumnium bus bar 4 strips (coverd coded insulated PVC sleeves) 200 Amps capacity 60 - 70 cm long including connection etc complete - 01 set, (ii) Indicator lamp for RYB phase, (iii) Moulded case circuit breaker 50 - 63 Amps 415 volts, Thermal magnetic release with adjustable over load setting and adjustable shor circuit setting, 4 pole, lcs = 100% lcu, 25 KA breaking capacity = 01 Nos. Make: L & T Cat Part No CM91712OOHOOG or equivalent in Schneider / Legrand, (iv) Flush mounted type 96 x 96mm, VAF + PF, input measurement range 50 - 520 VAC (P-P), Accuracy Class 0.5M.
OUTGOING: - (i) Modular case circuit breaker 40 - 50 Amps, 415 Volts, Thermal Magnetic release with adjustable over load setting and adjustable short circuit setting, 4 pole, lcs = 100%lcu, 25 KA breaking capacity = 01 Nos. Make: L&T Cat Part No : CM91712OOGOOG or equivalent in Shhneider / Legrant, (ii) 3 Pole power contactors MO type with inbuilt surge suppressor, RoHS complaint with AC1 rating 45 Amps - 01 Nos, Make: L&T Car Part No CS94567 or equivalent in Havells/ABB, (iii) Astronomical timer with operating voltage 110 - 240 VAC, 1 phase, Base/Din mounted type-01 Nos. Make: L&T Cat Part No T2DDT7 or equivalent in Havells
M/s Dhani Enterprise
M/S C.M.V CONSTRUCTIONS
Tractors Machinary Components
M/s SS Engineering
M/S MANOJ PAUL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .