Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹63.3 LAccepted-AOC 4TH FLOOR OFFICE NO 417 MAGNETO OFFIZO COMMERCIAL MALL VIP ROAD RAIPUR 492001 | RAIPUR | RAIPUR | CHHATTISGARH | 492001 | L1 | Accepted-AOC L1 for all items | |
| 2 | L2₹99.9 L+₹36.6 L (57.8%)Rejected-AOC B 46 INDUSTRIAL AREA SECTOR 59 NOIDA UP 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L2 | Rejected-AOC L2 | |
| 3 | Rejected-Technical PLOT 4 S NO 17 1 B KOTHRUD IND ESTATE KOTHRUD PUNE PUNE MAHARASHTRA 411038 | PUNE | MAHARASHTRA | 411038 | - | Rejected-Technical Due to non submission of valid EMD and tender fee | |
| 4 | Rejected-Technical 4 1309 NEW SIR SYED NAGAR ALIGARH ALIGARH UTTAR PRADESH 202002 | ALIGARH | UTTAR PRADESH | 202002 | - | Rejected-Technical Due to non submission of valid order copies to fulfill PQR clause(b) |
| Sl No | Description | Qty | Unit | Aaxis Nano Technologies Pvt. Ltd. L1 | EECG INDUSTRIAL SOLUTION PVT LTD L2 |
|---|---|---|---|---|---|
| 1.00Ultrasonic type flow meters of following specifications: Sensor: (1) Type: Ultrasonic Clamp on, 1 channel , one sensor set (2 ) Measuring Principle: Transit Time difference (3) Type of mounting - 2 trasverses (4) Sensor Material :Anodized Al (Standard) (5) Sensor Holder Material : SS 1.4308 /CF-8 (6)Sensor Housing- SS 1.4301/304 (7) strapping bands/bracket: SS 1.4301/304 (8) Sensor contact surfaces: chemically safe plastic Transmitter with totalizer: (1) Accuracy: +/- 0.5 % instrument error, +/- 1.5 % installation error, Total error +/-2 % of measured value (2) Repeatability : < +/- 0.2 % (3) Converter: Die cast Al (4) Power supply: 85-250 VAC, 50 Hz (5) Calibration range: As per max flow in area of application (6) Signal cable: Double shielded, 10 m (7) Display : Instantaneous flow rate with cumulative flow totalizer (8) Output: 4-20 mA HART 7, Pulse O/P, frequency O/P, Status O/P, Control O/P (9) Protection class: IP67/68 (10) Housing: AI diecast (11) Application: Hot/cold water (12) Zero Flow Detection , (13)Security : Temperproof | |||||
| 1.10 | Ultrasonic type flow meters for following areas:
(1)Raw Water Inhouse-600 NB Line Size-600 NB Qty-1No. (2) Raw Water Interconnection line between PH-I & PH-II, Line Size-600 NB , Qty-1No (3) Plant Potable Line Size- 80 NB , Qty- 1 No.
(4)Colony Potable Line Size-80 NB Qty-1No.
(5)CT makeup Line Size-100 NB Qty-1No.
(6)CW blow down to ash water sump Line Size-80 NB, Qty-1No.
(7)PTP sludge to ASH water sump Line Size-200 NB, Qty-1No.
(8)DM transfer pump common discharge line Line Size-200 NB Qty-1 No.
(9)Discharge line of sludge pit in DM plant-II(Waste water line for deashing) , Line Size-300 NB , Qty-1No. (10) Discharge line of OWS(Oily water system), Line Size-150 NB, Qty-1No.
(11) Discharge line-25 NB of (all 8 nos) sewage treatment plants to-
(i) Hydrogen plant
(ii) Silo
(iii) switchyard
(iv) primary crusher
(v) secondery crusher
(vi) TP-1
(Vii)Ash water recovery
(Viii) DM plant
(Qty -8 nos.(1 qty each of i to viii)
(As per Tender Schedule) | 18 | Nos. | 3,70,500 ₹4,37,190 | 1,66,320 ₹1,96,257.6 Lowest |
| 2.00 | Electromagnetic flowmeter for Ash Slurry Disposal lines
Inline version.
(1) Application: for Ash slurry measurement ,(2) Installation length: DVGW/ISO conform.
(3)Approval non hazardous area (4) Design: Lap joint flange (5) Sensor Housing : SS 304 , Liner : Natural Rubber (6) Process Connection: Cl.150, carbon steel, lap (7) Electrodes: SS 316 Brush type , meas. electrode only (8) Protection for sensor : IP68 Transmitter with Totalizer (1) Corrosion-resistant transmitter version., Failure modeStop
(2) Curr. output : 4...20 mA NAMUR
(3) Power Supply: 100-240VAC
(4) Input: 4-20mA HART, 2x pulse/freq.
(5) Housing: Remote, alu, coated ,IP66 NEMA 4X
(6) Remote Version: 5m/15ft coil + signal cable
(7) Electrical Connection: Thread NPT1/2 joint flange ASME B16.5
(8) Calibration Flow: 0.5%
(9) Totalizer, 8 digit T/Hr.
(10) Accuracy: +/- 0.35 % of Measured value,
(11) Process Connection: Flange connection Cl 150 ASME, 316L/1.4404 ASME B16.5 flange (12) Adjustment : Software Feature: Factory set up; basic version
(13) Protection for transmitter : IP-67, (14) Zero flow detection (15) Reverse flow detection Note:- Reducer/Expander not acceptable | 4 | Nos. | 1,75,000 ₹2,06,500 Lowest | 5,93,476 ₹7,00,301.68 |
| 3.00Work part | |||||
| 3.01 | Instalation & commissioning of above flow meters alongwith all required material, hardware, accessories, consumables etc | 22 | Nos. | 50,000 ₹59,000 Lowest | - |
Tender Value
₹1.3 Cr
EMD Value
₹2 L
Closing Date
16 Aug 2023, 3:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE Purchase dongalia
SE Purchase dongalia
Supply, Installation and Commissioning of Ultrasonic and Magnetic Flow meters along with totalizer for various locations at 2X660MW SSTPP, Dongalia, Khandwa
2023_MPPGC_273450_1
PT-2365
Open Tender
Miscellaneous Goods
Item Rate
90 days
Dongalia
Please refer Tender documents.
11 documents required · 11 mandatory
₹5,000
Yes
₹2 L
Yes
17 Sept 2025
26 Jun 2023
21 Aug 2023
26 Jun 2023
16 Aug 2023
26 Jun 2023
Ultrasonic type flow meters of following specifications: Sensor: (1) Type: Ultrasonic Clamp on, 1 channel , one sensor set (2 ) Measuring Principle: Transit Time difference (3) Type of mounting - 2 trasverses (4) Sensor Material :Anodized Al (Standard) (5) Sensor Holder Material : SS 1.4308 /CF-8 (6)Sensor Housing- SS 1.4301/304 (7) strapping bands/bracket: SS 1.4301/304 (8) Sensor contact surfaces: chemically safe plastic Transmitter with totalizer: (1) Accuracy: +/- 0.5 % instrument error, +/- 1.5 % installation error, Total error +/-2 % of measured value (2) Repeatability : < +/- 0.2 % (3) Converter: Die cast Al (4) Power supply: 85-250 VAC, 50 Hz (5) Calibration range: As per max flow in area of application (6) Signal cable: Double shielded, 10 m (7) Display : Instantaneous flow rate with cumulative flow totalizer (8) Output: 4-20 mA HART 7, Pulse O/P, frequency O/P, Status O/P, Control O/P (9) Protection class: IP67/68 (10) Housing: AI diecast (11) Application: Hot/cold water (12) Zero Flow Detection , (13)Security : Temperproof
Ultrasonic type flow meters for following areas: (1)Raw Water Inhouse-600 NB Line Size-600 NB Qty-1No. (2) Raw Water Interconnection line between PH-I & PH-II, Line Size-600 NB , Qty-1No (3) Plant Potable Line Size- 80 NB , Qty- 1 No. (4)Colony Potable Line Size-80 NB Qty-1No. (5)CT makeup Line Size-100 NB Qty-1No. (6)CW blow down to ash water sump Line Size-80 NB, Qty-1No. (7)PTP sludge to ASH water sump Line Size-200 NB, Qty-1No. (8)DM transfer pump common discharge line Line Size-200 NB Qty-1 No. (9)Discharge line of sludge pit in DM plant-II(Waste water line for deashing) , Line Size-300 NB , Qty-1No. (10) Discharge line of OWS(Oily water system), Line Size-150 NB, Qty-1No. (11) Discharge line-25 NB of (all 8 nos) sewage treatment plants to- (i) Hydrogen plant (ii) Silo (iii) switchyard (iv) primary crusher (v) secondery crusher (vi) TP-1 (Vii)Ash water recovery (Viii) DM plant (Qty -8 nos.(1 qty each of i to viii) (As per Tender Schedule)
Electromagnetic flowmeter for Ash Slurry Disposal lines Inline version. (1) Application: for Ash slurry measurement ,(2) Installation length: DVGW/ISO conform. (3)Approval non hazardous area (4) Design: Lap joint flange (5) Sensor Housing : SS 304 , Liner : Natural Rubber (6) Process Connection: Cl.150, carbon steel, lap (7) Electrodes: SS 316 Brush type , meas. electrode only (8) Protection for sensor : IP68 Transmitter with Totalizer (1) Corrosion-resistant transmitter version., Failure modeStop (2) Curr. output : 4...20 mA NAMUR (3) Power Supply: 100-240VAC (4) Input: 4-20mA HART, 2x pulse/freq. (5) Housing: Remote, alu, coated ,IP66 NEMA 4X (6) Remote Version: 5m/15ft coil + signal cable (7) Electrical Connection: Thread NPT1/2 joint flange ASME B16.5 (8) Calibration Flow: 0.5% (9) Totalizer, 8 digit T/Hr. (10) Accuracy: +/- 0.35 % of Measured value, (11) Process Connection: Flange connection Cl 150 ASME, 316L/1.4404 ASME B16.5 flange (12) Adjustment : Software Feature: Factory set up; basic version (13) Protection for transmitter : IP-67, (14) Zero flow detection (15) Reverse flow detection Note:- Reducer/Expander not acceptable
Work part
Instalation & commissioning of above flow meters alongwith all required material, hardware, accessories, consumables etc
EECG INDUSTRIAL SOLUTION PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .