Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹10.1 LAccepted-AOC | l1 | Accepted-AOC L1 | |
| 2 | l2₹10.4 L+₹26,650 (2.63%)Rejected-Finance | l2 | Rejected-Finance l2 | |
| 3 | l3₹11.0 L+₹87,500 (8.63%)Rejected-Finance NEAR KRIPAN GATE PO BINNAGURI DIST JALPAIGURI W B PIN 735203 | JALPAIGURI | WEST BENGAL | 735203 | l3 | Rejected-Finance l3 |
Tender Value
₹11.3 L
EMD Value
₹22,600
Closing Date
30 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE (Navy) Lakshadweep C/o NOIC (LAM) Navy Office Coast Guard Road Kavaratti Islands UT of Lakshadweep-682555
PROVISION OF LT AIR CIRCUIT BRAKER ALONG WITH ASSOCIATED WORKS UNDER AGE B R I KAVARATTI OF GE NAVY LAKSHADWEEP
2022_MES_516356_2
8327/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE NAVY LAKSHADWEEP
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER NAVY LAKSHADWEEP
₹22,600
Yes
6 Aug 2022
12 May 2022
1 Jun 2022
12 May 2022
30 May 2022
18 May 2022
60 days
Amount
Supply & install, test and commission of 3 phase 4 pole, 415V LT Air Circuit Breaker (ACB) 800A, short circuit rating 80kA confirms to IS/IEC 60947-2 & IEC 60947-2, Short time fault withstand capacity, Icu= Ics =Icw for 1sec, Over load & short circuit protection, power harmonic measurement, temparature rise monitoring & protection circuit, Data communication on modbus horizontal Draw-out type accommodate in factory made of CRCA sheet powder coated pedestal type panel with sheet thickness not less than 2mm for provision of connecting LT cables with copper bus bar rating having current rating of 1600A for phase and neutral having following sapres:- (i) Inbuilt electrical & mechanical Anti-pumping system (ii) Common fault indication micro switch, 4 NO + 4 NC Aux contacts (iii) Smart racking shutter type, safety shutter assembly (iv) Racking Handle, Door sealing frame, Pad - locking arrangements for ON/OFF (v) Rating Error preventer (vi) Arc shield Note : LT Panel manufacturer should have CPRI approval and certificate should produce the dept before sample approval.
Supply and Install, test and commission in replacement of factory made outdoor type/Floor mounted thermoplastic polycarbonate cubical type feeder pillar box IP 65 protection suitable for 3 phase 4 wire 415 V, 50 Hz of size (1700x2050x700mm) with 400 Amps rated copper busbar, internal wiring connection with suitable size copper cables and MS angle iron based frame painted with two coats of synthetic enamel paint over a coat of red oxide primer including PCC foundation to accmoomodate unserveceable one comprising of following:- (i) On Load change over switch TPN 415V 250A 36kA-01 (incoming) (ii) MCCB TPN 415V 100A 36kA-08 (outgoing) (iii) Digital voltmeter 0-500 V - 01 No (iv) Digital ammeter with Cts 250 amps- 01 No (v) Tamper proof digital KWH enery meter with CTs - 01 No (vi) Indicator lamp LED type 240V AC (RYB) - 01 set complete all as specified and as directed by Engineer-in-Charge. Note : LT panel manufacturer should have CPRI approval and certificate should produce the dept before sample approval.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip of size 20 x 3 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point or indicated including testing on completion complete all as specified and as directed by Engineer-in-Charge.
Supply and laying of earth continuity conductor madeup of copper conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3 mm copper strip complete all as specified and as directed by Engineer-in-Charge.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 250 Amps complete all as specified and as directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3½ core complete all as specified and as directed by Engineer-in-Charge.
PHEJAYS AGENCIES
N K Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .