Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹29.9 L+₹3.2 L (12.1%)Rejected-Finance NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹34.0 L+₹7.3 L (27.4%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹35.0 L+₹8.3 L (31.2%)Rejected-Finance 402 C WING BUILDING NO 86 NAVRANG CO OP HSG SOCIETY LTD TILAKNAGAR CHEMBUR MUMBAI 89 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400089 | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹38.6 L+₹11.9 L (44.6%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
29 Jun 2020, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIRS / REPLACEMENT OF AC SHEETS, ROOF GUTTERS CLEANING TO ROOF AND ROOF TREATMENT TO CERTAIN BLDGS AT DRDL/ASL, ANURAG, GE OFFICE COMPLEX, DRDL DSC COMPLEX, MES KEY PERS QTRS AND ADJOINING AREA UNDER AGE B/R-I HYDERABAD
2020_MES_340882_1
GE I KBAGH TOKEN 14 OF 2020 2021
Open Tender
Civil Works
Item Rate
270 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹98,000
Yes
18 Aug 2020
25 Apr 2020
1 Jul 2020
25 Apr 2020
29 Jun 2020
9 May 2020
25 Apr 2020 - 30 Apr 2020
Amount
M&L Pre painted galvalume aluminium zinc coating GI based corrugated /trepezoidal steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws including dismantling of existing asbestos cement (corrugated/semi corrugated ,etc) sheets complete all as specified and directed.
M&L Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in ridges fixed with self tapping screws including dismantling of existing ridge complete all as directed.
S&F in repairs polycarbonate sheet 10 mm thick fixed with aluminium profile top at joint, aluminium section 50 mm wide with 2 mm thick including fixed with self tapping screw and full welding of 10 mm thick, scaffolding and wastege material for fixing in doom complete all as directed. Note: Safety precautions to be taken deemed to be included in quoted rate. Make:- Lexan,Arolite or Techno commercial equivalent as approved by GE
S&F 6mm thick asbestos cement corrugated or semi corugated sheets in roof covering fixed with L or J type hook or cranked hook, bolts including dismantling of existing asbestos cement (corrugated/semi corrugated ,etc) sheets complete all as specified and directed.
Dismantling of existing AC (corrugated, semi corrugated etc) sheet & re-fixing the same in roof covering fixed with L or J type hook or cranked hook, bolts complete all as specified and directed.
M&L Asbestos cement single piece adjustable serrated ridge for corrugated or semi corrugated sheets including dismantling of existing sheet complete all as directed.
S&F in repairs 1.00 mm thick plain black, mild steel sheeting in ridges, hips valley gutters drip and straight flashings (length and girth) welded or soldered joints are provided complete all as directed.
M&L brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick built in CM 1:4 including domolition of existing brick work, complete all as directed .
M&L brick work with old size sub class 'B' bricks straight or curved on plan exc 6M mean radius built in CM 1:6 including demoliton of existing brick work complete all as directed .
M & L Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even & smooth without using extra cement complete all as directed.
S&F in repairs false ceiling with pre-coated standard GI angle, Tee and grid suspended with 2 mm dia GI wire at 600mm c/c ,Angle of size 25x25x0.7mm fixed around, main Tee and Cross Tee of the section 38x25x0.7mm with soffits clips, holding and level clips, Gypsum board of size 600x600 mm of 12.5 mm thick with white paper layer on face side as directed and applying two coats of acrylic emulsion over a coat of primer, complete all as directed.
S&F in repairs 12mm thick Gyp board false ceiling of any size fixed with screws as directed and applying two coats of acrylic emulsion over a coat of primer complete all as directed .
S&F in repairs gypsum corner moulds of decorative type fixed over wall junction and finished similar to ceiling all as directed cross section area exc 13 sqcm and n.exc 25 sqcm complete all as directed.
M/L for preparation of new surfaces and applying two coats of cement base paint over primer complete all as directed.
M&L for cement concrete type B1 1:2:4 (using 20mm graded stone aggregate) as in padding concrete , coving of in vertical junctions, coping and plat form for OH water tanks etc on roof top including demolition of existing PCC complete all as directed.
Taking down existing roof treatment of tarfelt or of any description completely as directed and removing the debris to a distance exc 250m and n.exc 500m and depositing where directed complete all as directed.
M&L Brushing neat cement slurry with 3.0 Kg of cement per Sqm on roof surface complete all as directed.
M&L for cement screed/rendering 10mm thick in CM (1:3) over roof slab including parapets inverted beams etc. mixed with water proofing compound, rendering all as specified and directed (WPC shall be measured and paid separately) and finished even and smooth without using extra cement complete all as directed.
Supply only integral water proofing compound
M&L for APP based polymeric membrane 3 mm thick reinforced with polyster non wove fabric over a coat of hot bitumen 85/25 grade applied @ 1.20 Kg/Sqm after priming the surface with bitumenious emulsion (tack coat) @ 100 gms/sqm with 10 cm overlap of the membrane to be provided duly fused uniformly by LPG torch flame complete all as directed. Note: Work shall be carried and by authorised applicator only.
M&L for preparation of surface and applying one coat of aluminium paint @ 100 ml/sqm over APP membrane all as specified and directed.
S&F 20mm thick hydraulically pressed cement tiles laid over 15mm thick cement screed bed 1:6 mixed with water proofing compound and joined with CM 1:3 mixed with 5% crude oil by weight of cement over APP membrane.
M&L Non skid coloured ceramic tiles 7 mm thick area of each tiles exc 0.06 sqm but n.exc 0.11 sqm as in floor finishes set and jointed in neat cement slurry and pointed in white or coloured cement to match laid on and including 15 mm thick screed bed in cement mortar (1:4) , over 25mm thick PCC 1:2:4 type B-1 (20 mm graded aggregate) finished even and fair to receive tiles including dismantling of existing tiles, cement mortar, bedding and padding complete all as directed.
M & L for coloured glazed ceramic tiles of size 300x200x7mm thick on vertical surfaces such as skirting/dado, jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 15 mm thick rendering in cement mortar (1:4) as backing coat including dismantling of existing tiles including cement mortar bedding complete all as directed.
M & L for coloured glazed ceramic tiles of size 350x250x7mm /450 x 300 x 7 mm thick on vertical surfaces such as skirting/dado, jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 15 mm thick rendering in cement mortar (1:4) as backing coat including dismantling of existing tiles including cement mortar bedding complete all as specified and as directed.
M & L for 10mm thick, light shade vitrified ceramic tiles, area of each tile n exc. 0.36 sqm as in floors, set and jointed in neat cement slurry and pointed in cloured cement to match laid on and including 15 mm thick screed bed in cement mortar (1:4) ,complete including dismantling of existing tiles including cement mortar bedding all as specified and as directed..
All as per Sl item No. 26 above, but as in skirting/dado laid on and including 15 mm thick rendering in cement mortar (1:4) as backing coat including dismantling of existing tiles including cement mortar bedding , complete all as specified and as directed..
S&F in repairs vitrous china squatting pan orrisa pattern size 580x440mm white with integral footrest incl trap etc complete making good to floor (excluding flushing cistern and flush pipe), complete all as specified and as directed.
S&F in repairs vitrous china white wash down water closet pan, pedestal pattern including fixing bolt, plastic water closet seat and cover with recessed bottom with MS CP hinging device (excluding flushing cistern and flush pipe), complete all as specified and as directed .
S&F in repairs Vitreous china Urinal half stall type, white (excluding flushing cistern and waste pipe), complete all as specified and as directed.
S&F in repairs PVC valveless, syphonic action type , flushing cistern , low level, white , with inlet, ball valve ,bend float and handle including brackets, complete all as specified and as directed .
S&F in repair 15mm bore angle valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in repair 15mm bore bib cock cast copper alloy chromium plated, screwed down complete all as specified and as directed.
S&F in repairs 15mm bore Fancy type, Pillar taps , cast copper alloy , with capstan heads , chromium plated , screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F in repairs urinial spreader of CP for fixing with 15mm dia pipe min wt 60 gms, complete all as specified and as directed.
S&F in repairs Galvanised steel water tubing 15 mm bore Medium Grade with all fittings , fixed on walls and ceiling or laid in floors as required, complete all as specified and as directed.
S&F in repairs Ball valve PTMT for GI pipe 25 mm bore(dia) (Minimum weight 210 Grams), High pressure with Epoxy coated aluminium Rod and High densitye plastic Ball, screwed for Iron pipe and fixed in repairs, complete all as specified and as directed.
S&F Roof trusses (framed) trussed,purlins, crane gantries rail and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces cleats etc., including dismantling of old work complete all as specified and as directed.
Preparation new or previously untreated steel surface and applying two coats synthetic enamel paint over one coat of red oxide primer of any description over 10cm in width or girth not otherwise described
Disconnecting water storage/service tank (RCC/PVC tank) exc 250 Litre but not exc 500 Litre capacity, cleaning and removing all scales Dirt, etc from Tank and mouths of circulating and wash out pipes of Tank with bleaching power. Re-hoisting in same position and re-connecting, including writing DATE OF CLEANING and DUE ON complete all as specified and as directed.
All as per item No-40 above but exc 500 ltr but not exc 1000 Litre capacity,
All as per item No- 40 above but exc 1000 ltr not exc 2000 Ltrs
Supply and fixed in repair PVC tank cover screw type for 500 Ltr capacity complete all as directed.
Supply and fixed in repair PVC tank cover screw type for 1000 Ltr capacity of approved brand.
S & F Machine pressed precast concrete interlocking paver block any shape and size with gray cement and pigment (approved by GE) confirming to IS 15658-2006 of 60 mm thickness, M-35 grade including laid over 100mm thick sand cushion bed and preparing the surface to uniform level to receive tiles and the corners shall be finished with 1:2:4 PCC (using 20 mm graded stone aggregate) finished the surface even and smooth including taking down old unserviceable tiles alongwith sand bed and depositing debries in low laying areas upto a lead of 500 mtrs complete all as directed.
Cleaning of Rain Water pipes and removing the materials (sludge) to distance n exc 50m, complete all as specified and directed.
Cleaning of Valley Gutter, roof sorrounding area mud, tree leaves etc including water outgoing holes at hight of bldg, not less than 15mm removing the materials (sludge) to distance n exc 50m, complete all as specified and directed. Note: Charges for safety measurements shall be deemed to included in quoted rate
Taking down / Cutting / Removing growth of Vegetations, Plants, roots etc, in roof, chajjas, at (any floor and any height), and making good to damaged portion with PCC (1:2:4), type B-0, complete all as specified and as directed.
S&F S/S grade 304 railing 50 mm dia hand rail and 3 Nos 16 mm dia horizontal rails and 40 mm dia verticles complete incl grinding and buffing at joints all as specified and directed including taking down old existing railing
M&L for flush pointing in CM 1:3 to bricks laid flat or brick tiles in roofs, floors, pavings etc including racking out joints complete all as directed
M/S GDR CONSTRUCTIONS
M/S VASU ENGINEERS
Sai construction & services
Anjana corporation
sanjar enterprises
Ravi Enterprises
PAVAN ENTERPRISES
SHAH ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .