Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 24 FLOWER STREET FLOWER STREET SAIDAPET CHENNAI CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹18.5 L
EMD Value
₹36,990
Closing Date
28 Jan 2025, 3:00 pmClosed
EE
BSNL EC-2 kellys Chennai
Rewiring of SQ at Anna Nagar Netaji circle and Valluvar circle
2025_BSNL_224296_1
NIT No 08/EE-T/EC-II/CH/2024-25
Open Tender
Electrical Works
Works
60 days
Annanagar SQ
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
BSNL Chennai Telephones
₹36,990
Yes
18 Feb 2025
18 Jan 2025
29 Jan 2025
18 Jan 2025
28 Jan 2025
18 Jan 2025
18 Jan 2025 - 28 Jan 2025
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required. (Group A )
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2x1.5 sq.mm + 1x1.5 sq.mm earth wire
2x6 sq.mm + 1x6 sq.mm earth wire
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing 5/6 Amps piano type switch and 5/6 amps 3pin socket with swicth box including connections etc. as required.
Supply and fixing of 4Nos.5A switch and 4Nos 5A socket with suitable MS box and covering with phenolic laminated sheet with necessary connections etc.as required.
S/F brass batten/angle lamp holder i/c connection etc as required.
S/F call bell buzzar and piano type bell push,suitable for AC/DC single phase 230 V complete as reqd.
Supplying and fixing of LED round fitting suitable for 230 volts 50 Hz Ac supply i/c including connections etc. complete as required.
Supply and fixing of 20W LED type type fitting directly on ceiling /wall including connection with 1.5 Sq.mm FR PVC insulated, copper conductor, single core cable and earthing etc as reqd.,
S/F of 48" high speed ceiling fan with downrod I/c wiring the down rod of standard length (upto 30cm) with 1.5sq.mm PVC insulated copper conductor, single core cable etc. as reqd.. (make : Crompton /Bajaj /Khaitan /Usha/ orient or SS Make)
Supply and fixing of fancy type LED fitting directly on wall including connection with 1.5 Sq.mm FR PVC insulated, copper conductor etc as reqd.,
SITC of cubicle type wall mounting metering panel consisting the following switch gears, space for energy metering i/ c wiring with suitable size of copper conductor complete as reqd. a)100 Amps 4 strip Al. busbar 1 set with sealable arrangement. b)32 Amps rewirable cutout - 8 Nos c) Space to accommodate 8 Nos of single phase energy meters d) 32 Amps SPN Mainswitch with R/W cut outs - 8 Nos. e) 16 Amps SPN Mainswitch with R/W cut outs - 1 No.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way Double door
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connection, testing and commissioning etc as reqd.,
supplying and fixing the following in the existing MCB Distribution boards i/c connections etc complete as required.
6 - 32 A SP MCB 'C' series
Blankers
S/F 16 SWG thick MS sheet for DB adaptors, junction boxes etc, including cutting, bending, grinding, painting two coats of redoxide and approved colour paint etc. as reqd
Supply and laying of 4x50 Sq.mm on surface wall with necessary connections etc.as required.
Supply and fixing of 63A double break Switch fuse unit with HRC fuse with necessary connections etc.as required.
Earthing with GI earth pipe 4.5m long x 40mm dia including accessories, and providing masonry enclosure with coverplate having locking arrangement etc. (but with charcoal or coke and salt) complete as required.
Providing and laying earth connections from earth electrode with 6 SWG dia GI wire in 15 mm dia GI pipe from earth electrode including connections with GI thimble excavation and re-filling etc.as reqd
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required.
SSK ELECTRICALS (BID ID -813045)
SAIDAPET ELECTRICALS CHN PVT LTD (BID ID -811034)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .