Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC 180 10 STREET NO 10 HARPAL NAGAR NEAR TRIVENI MANDIR BHATTI ROAD BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC accepted | |
| 2 | L2₹17.0 L+₹1.2 L (7.90%)Rejected-AOC | L2 | Rejected-AOC rejected |
Tender Value
₹14.4 L
EMD Value
₹28,736
Closing Date
9 Oct 2023, 2:00 pmClosed
Xen,Kandi Canal Stage2 Division,hoshiarpur
Xen,Kandi Canal Stage2 Division,hoshiarpur
Estimate For Restoration Of Damage Direct Outlet At. 122.700 Km Right Side Of Kandi Canal Stage-2.
2023_WR_110155_1
56
Open Tender
Civil Works - Canal
Item Rate
60 days
Hoshiarpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
₹28,736
Yes
6 Mar 2024
30 Sept 2023
9 Oct 2023
30 Sept 2023
9 Oct 2023
30 Sept 2023
Amount
WATER SUPPLY
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of ewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
Earth work upto 1.5 m. Depth for
All classes of soil except rock
Providing & fixing Single air valve ISI Marked as per IS-14845 including jointing , cost of nut bolts & rubber insertion all carriages complete.
C.I Single air valve screwed (Size 50mm)
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
(a) Size 0.6 m. x 0.6 m.
(b) Size 0.9 m. x 0.9 m.
Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Capacity of Air compressor 300 cfm at 250 PSI
BRICK WORK
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
PLASTERING & POINTING
12.5 mm thick cement plaster 1:4
Cement rendering on plaster 1mm thick
CONCRETE
1:2:4 Cement concrete
mixing by mechanical means using concrete mixer volumetric type
STEEL AND IRON WORK
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete 12mm of steel
Providing, Laying , fixing & jointing of uP.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. pipe of 2.5 Kg. /sqcm 160mm
Providing, Laying , fixing & jointing of uP.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. pipe of 2.5 Kg. /sqcm 180mm
Providing, Laying , fixing & jointing of uP.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. pipe of 2.5 Kg. /sqcm 250mm
Providing, Laying , fixing & jointing of uP.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. pipe of 2.5 Kg. /sqcm 280 mm
Providing, Laying , fixing & jointing of u P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. pipe of 2.5 Kg. /sqcm 315mm
Providing, Laying , fixing & jointing of u P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. pipe of 2.5 Kg. /sqcm 400 mm
Providing & fixing ISI Marked . Alfa Valve 160 mm
Providing & fixing ISI Marked . Alfa Valve 180mm
Providing & fixing uPVC Bend (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge. 160mm
Providing & fixing uPVC Bend (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.180mm
any other item
Deepak Kumar Beetan
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .