Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹1.3 Cr | L1 | Accepted-AOC Lowest Tender |
| 2 | L2₹1.6 Cr+₹24.8 L (18.6%)Rejected-Finance | ₹1.6 Cr+₹24.8 L (18.6%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹1.7 Cr+₹39.9 L (29.9%)Rejected-Finance BU 02 SFS FLATS OUTER RING ROAD PITAMPURA NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | ₹1.7 Cr+₹39.9 L (29.9%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹1.7 Cr+₹41.1 L (30.9%)Rejected-Finance | ₹1.7 Cr+₹41.1 L (30.9%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹1.8 Cr+₹50.7 L (38.0%)Rejected-Finance | ₹1.8 Cr+₹50.7 L (38.0%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹2.3 Cr
EMD Value
₹3.1 L
Closing Date
10 Aug 2020, 6:00 pmClosed
CHIEF ENGINEER DELHI ZONE
HQ CHIEF ENGINEER DELHI ZONE
Special repair and replacement of BER package type AC plant at Army Hospital RR under GE EM RR Hospital Delhi cantt-10
2020_MES_329118_1
CEDZ-15 OF 2019-20
Open Tender
Civil Works
Item Rate
270 days
DELHI CANTT
MES contractor enlisted in MES under class B cat c (i) having deposited Standing Security of Rs 4.00 lakh with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹2,000
GE EM RR HOSPITAL
₹3.1 L
Yes
27 Sept 2020
5 Mar 2020
13 Aug 2020
5 Mar 2020
10 Aug 2020
3 Aug 2020
Amount
Item No .1 Taking down of old UNSV/Package/ Ductable Type Air conditioning Plant including connected acessories(Floor/Ceiling mounted AHUs of various capacities, Hot water Genrators, LT Panel Boards, Electric driven pump motor) of various capacity, Details as given below:-(a) 4 x 7.5 TR , Intervantion Lab (b) 4 x 7.5 TR, MRI Centre (c) 4 x 15 TR ,JRC (d) 2 x 15 TR, Path Lab. (e) 2 x 30 TR , ART Centre (f) 2 x 30 TR , BMT Centre. NOTE:- OLD EQUIPMENT ARE THE PROPERTY OF DEPARTMENT AND TO BE DEPOSITED TO MES YARD.
Item No .2 Supply, installation, testing and commissioning of air cooled Scroll chiller with multi compressor and comprising of one or multiple hermetic compressor ,DX evaporator shell and tube condenser ,suitable expansion device suitable for operation on R 407 c Refrigrent of capacity minimum 30 TR for ART and BMT centre including suitable LT panel Board indoor type CPRI approved , made out of 2mm thick MS Sheet comprising of MCB,MCCB,Contactors,Relays fully automatic,Star-Delta starter,Over load protection,CT Coils,Digital Voltmeter,Ameter,Start/stop push Button and Phase indicator of suitable capacity for ART and BMT with following parameter :- (a) Chilled water in Temp : 12 Deg c (b) chilled water out Temp : 7 Deg c (c) WBT 83 Deg F (d) Ambieant temp 45 Deg centigrate. Note- (i) BMT Centre - 2 Nos (ii) ART Centre- 2 Nos (iii) The contractor must visit the site before quoting the rate.
Item No .3 Supply installation testing and commissioning of Chilled water pump set monoblock type with capacity of 156 USGPM , 20 M Head set of for BMT and ART complete all as specified and directed. Note- (i) BMT Centre - 2 Nos (ii) ART Centre- 2 Nos (iii) The contractor must visit the site before quoting the rate.
Item No .4 Supply, installation, testing and commissioning of Double Skin, Floor Mounted, Air Handling Unit (AHU) with 6 Rows Deep Coil and 2 rows heating coils of nominal min capacity of 12000 CFM with static pressure 125 mm including VFD of suitable capacity and LT panel board CPRI approved, made out of 2 mm thick MS Sheet comprising of MCB,MCCB,Contactors,Relays,Star-DeltaTimer,Over load protection,CT Coils,Digital Voltmeter,Ameter,Start/stop push Button and Phase indicatorof suitable capacity complete for ART and BMT with following parameters DOUBLE SKIN CASING I).Outer skin - 0.6 mm pre coated GI II).Inner skin - 0.6mm pre coated GI III) Frame work - Thermal break AL profile with thermal barrier IV) Thickness of insulated panels- 43mm thick ,CFC free PUF injected (density 40kg/cum) V) Material of drain Pan - 18 GSS-304 tray duly insulated with 13mm closed cell nitrile insulation VI) Unit base - GSS base channel Note- (i) BMT Centre - 01 Nos (ii) ART Centre- 01 Nos (iii) The contractor must visit the site before quoting the rate.
CHW COIL/ HOT COIL : (i) Make of coil : AHRI certified as per test standard ARI-410 And UL certified for safety . (ii) Coil casing /blank Offs : SS-304 (iii) Material Of Tube : Copper (iv) Tube Diameter(mm/inch) : 12.7mm/1/2" OD (v) Thickness of tube (SWG/MM) : 27SWG / 0.41MM (vi) Header Material : MS (vii )Thickness & Material of Fins : 0.15mm Plain Aluminium (viii) No of fins per inch (FPI) : 11/12 (for cooling coil) (ix) No of fins per inch (FPI) : 08/10 (for Heating coil)
FILTERS : (I) Make of filters : Thermadyne /Spectrum /Puramatic /Mechmark (II) Media of filter : Synthetic (Non woven Type) (III) Efficiency of pre filters (EU-4) : 90% down to 10 micron (IV) Efficiency of fine filters (EU-5) : 99% down to 5 micron FAN & MOTOR : (I)Fan make : Kruger / Nicotra (II) Motor Make : ABB/Cromton/Bharat Bijlee /Havells/marathons /Siemens NOTE : Double skin floor mounted horizontal air handling unit shall have (SS-304 coil casing and SS-304 blank off) (Ill) Mixing box section with FA & RA Damper in Al construction (IV) Filter section with 50 mm thick (EU-4) flange typr pre filter and 305mm thick (EU-5) flange type fine filter mounted on GI common filter frame . (V) Coil section with 6 row deep chilled water cooling coil and 2 row deep heating coil . (VI) Fan section with imported DIDW centrifugal backword curved fan - drive set with V-belt & motor (EFF-3) (VII) Manualy Operated SA Damper in Al construction
Spl. Instruction :- 1-Motor will have (IE-2) VFD compatible . 2-Unit will be supplied in assembled condition duly factory run tested. 3-Mannually operated all damper in aluminium construction . 4-Light ,Limit switch, wire Guard & view Glass will be provided in fan section only. 5-Coil Casing & its blank off will be in SS
Item No .5 All as per Srl item No.4 (hereinbefore) but of the capacity 6000 CFM for ART, BMT and JRC complete all as specified and directed. Note- (i) BMT Centre - 02 Nos (ii) ART Centre- 02 Nos (iii) JRC Centre - 01 Nos (iv) The contractor must visit the site before quoting the rate.
Item No .6 All as per Srl item No.4 (hereinbefore) but of the capacity 3000 CFM for JRC and LAB complete all as specified and directed. Note- (i) Molecular Lab - 02 Nos (ii) JRC Centre- 01 Nos (iii) The contractor must visit the site before quoting the rate.
Item No .7 Supply, installation, testing and commissioning of air cooled Scroll chiller with multi compressor and comprising of one or multiple hermetic compressor ,DX evaporator shell and tube condenser ,suitable expansion device suitable for operation on R 407 c Refrigrent of capacity minimum 15 TR for JRC & path Lab including suitable LT panel Board indoor type CPRI Approved, made of 2 mm thick MS sheet comprising of suitable MCB,MCCB,Contactors,Relays,automatic Star-Delta starter,Over load protection,CT Coils,Digital Voltmeter,Ameter,Start/stop push Button and Phase indicator of suitable capacity as reccommended by OEM. The parameter shall be as under :- (a) Chilled water in Temp : 12 Deg c (b) chilled water out Temp : 7 Deg c (c) WBT 83 Deg F (d) Ambient temp 45 Deg centigrate. Note- The contractor must visit the site before quoting the rate to see the existing location of plant which is located at difference floor. Note- (i) Molecular Lab - 02 Nos (ii) JRC Centre- 04 Nos (iii) The contractor must visit the site before quoting the rate.
Item No .8 Supply installation Testing and comissioning of Chilled water/hot water Monoblock Pump set of capacity 40 USGPM, 20 Mtr Head for JRC and LAB complete all as specified and directed. Note- (i) Molecular Lab - (Chilled Water- 03 Nos & Hot Water- 01 Nos) (ii) JRC Centre- (Chilled Water-04 Nos & Hot Water- 02 Nos) (iii) The contractor must visit the site before quoting the rate.
Item No .9 Supply installation Testing and comissioning of Hot water Genrator of capacity 18 KW. Indoor type ,IP :52 & IP:55 Degree protaction as complete package with all components mounted wired and plumbed as necessary to allow installation and start up with minimum effort for JRC and LAB complete all as specified and directed. Note- (i) Molecular Lab - 01 Nos (ii) JRC Centre- 01 Nos (iii) The contractor must visit the site before quoting the rate.
Item No .10 Supply installation testing and comissoning of Ductable airconditioning units complete comprising of hermetically sealed scrool compressor with microprocessor based control , including copper refrigrent piping , electric wire connection between indoor and outdoor unit with R407C Refrigrent of capacity minimum 8.5 TR for MRI and Intervantion Lab complete all as specified and directed. Note- (i) Indoor unit to be fixed in celling. (ii) MRI - 04 Nos (iii) Invention Lab- 04 Nos (iii) The contractor must visit the site before quoting the rate.
Item No .11 Supply installation Testing and commissioning of seamless heavy gauge refrigrent copper piping of size 7/8" liquid line duly insulated with 13mm thick nitrile rubber insulation covered with alluminium foil (As per specific with K value of 0.027-0.029K Cal/hrs.M deg C at 0-16 Deg C) including taking down old copper pipe, support fixing joints etc complete all as specified and directed.
Item No .12 Supply installation Testing and commissioning of seamless heavy gauge refrigrent copper piping of size 11/8" liquid line duly insulated with 13mm thick nitrile rubber insulation covered with alluminium foil (As per specific with K value of 0.027-0.029K Cal/hrs.M deg C at 0-16 Deg C) including taking down old copper pipe, support fixing joints etc complete all as specified and directed.
Item No .13 Supply installation testing and commissioning of pvc insulated copper cable for 8.5 TR DSU of size 3 core 4 sqmm for compressor including PVC conduit of suitable size including taking down old copper pipe, support fixing joints etc complete all as specified and directed.
Item No .14 Supply, installation, testing and commissioning of pvc copper cable for 8.5 TR DSU of size 7 core 1.5 sqmm for indoor & outdoor units including PVC conduit of suitable size including taking down old copper pipe, support fixing joints etc complete all as specified and directed.
Item No .15 Supply installation testing and commissioning of pvc copper cable for 8.5 TR DSU of size 3 core 1.5 sqmm for indoor unit including PVC conduit of suitable size including taking down old copper pipe, support fixing joints etc complete all as specified and directed.
Item No .16 Supply installation testing and commissioning of MCCB 63 Amp 4 pole 36 KA for individual ductable units including taking down old MCCB complete all as specified and directed.
Item No .17 M & L in replacment of pre-insulated MS pipe of class 'C' having thickness of PUF insulation 36 mm of density 36 Kg/Cum and 26 Gauge GI clading complete suitable for above ground of size 100 mm including taking down old pipe alongwith accessoires complete all as specified and directed.
Item No .18 All as per item No 17 (hereinbefore) but of size 80 mm dia
Item No .19 All as per item No 17(hereinbefore) but of size 65 mm dia
Item No .20 All as per item No 17(hereinbefore) but of size 50 mm dia
Item No .21 All as per item No 17(hereinbefore) but of size 40 mm dia
Item No .22 All as per item No 17(hereinbefore) but of size 20 mm dia
Item No .23 Supply installation testing and commissioning of Butterfly valve of size 100 mm with insulation . The chilled valves shall be insulated with Alluminium faced Nitrile rubber of thickness 25 mm including taking down old u/s items complete all as specified and directed.
Item No .24 Supply installation testing and commissioning of Butterfly valve of size 80 mm with insulation . The chilled valves shall be insulated with Alluminium faced Nitrile rubber of thickness 25mm including taking down old u/s items complete all as specified and directed.
Item No .25 Supply installation testing and commissioning of Butterfly valve of size 65 mm with insulation . The chilled valves shall be insulated with Alluminium faced Nitrile rubber of thickness 25mm including taking down old u/s items complete all as specified and directed.
Item No .26 Supply installation testing and commissioning of check valve of size 80 mm with insulation . The chilled valves shall be insulated with Alluminium faced Nitrile rubber of thickness 25mm including taking down old u/s items complete all as specified and directed.
Item No .27 Supply installation testing and commissioning of check valve of size 65 mm with insulation . The chilled valves shall be insulated with Alluminium faced Nitrile rub.ber of thickness 25mm including taking down old u/s items complete all as specified and directed.
Item No .28 Supply installation testing and commissioning of Y Stainer of size 80 mm with insulation . The chilled valves shall be insulated with Alluminium faced Nitrile rubber of thickness 25mm including taking down old u/s items complete all as specified and directed.
Item No .29 Supply installation testing and commissioning of Y Stainer of size 65 mm with insulation . The chilled valves shall be insulated with Alluminium faced Nitrile rubber of thickness 25mm including taking down old u/s items complete all as specified and directed.
Item No .30 Supply installation testing and commissioning of Balancing valve of size 80 mm with insulation . The chilled valves shall be insulated with Alluminium faced Nitrile rubber of thickness 25mm including taking down old u/s items complete all as specified and directed.
Item No .31 Supply installation testing and commissioning of pressure gauge dial type rating 0-14 Kgs/cm & dial size 150mm including taking down old u/s items complete all as specified and directed.
Item No .32 Supply only in replacement of temperature gauge bottom connected, direct mounted type, of temperature range of 0 - 100°C or 32 - 212°F, including taking down old u/s items complete all as specified and directed.
Item No .33 Supply installation testing and commissioning of flow switch made of brass including taking down old u/s items complete all as specified and directed.
Item No .34 Supply installation testing and commissioning of auto air vent 10 mm including taking down old u/s items complete all as specified and directed.
Item No .35 Supply, fixing and laying, in replacement of GI duct fabricated from 24 Guage GI Sheet of any dimension/cross-section with and including all necessary fixing arrangement and support to roof and connected accessories i. e. nut, bolts, fastener, flat iron strip, clamps etc and taking down of old duct alongwith accessories, complete all as directed.
Item No .36 Supply, fixing and laying, in replacement of GI duct fabricated from 22 Guage Sheet of any dimension/cross-section with and including all necessary fixing arrangement and support to roof and connected accessories i. e. nut, bolts, fastener, flat iron strip, clamps etc and taking down of old duct alongwith accessories, complete all as directed.
Item No .37 Supply, fixing and laying, in replacement of Aluminium duct fabricated from 24 Guage Sheet of any dimension/cross-section with and including all necessary fixing arrangement and support to roof and connected accessories i. e. nut, bolts, fastener, flat iron strip, clamps etc and taking down of old duct alongwith accessories, complete all as directed.
Item No .38 Supply, fixing and laying, in replacement of Aluminium duct fabricated from 22 Guage GI Sheet of any dimension/cross-section with and including all necessary fixing arrangement and support to roof and connected accessories i. e. nut, bolts, fastener, flat iron strip, clamps etc and taking down of old duct alongwith accessories, complete all as specified and as directed.
Item No .39 Supply and fixing of accoustic lining with nitrile rubber 15 mm thick complete all as specified and directed.
Item No .40 Supply and fixing of thermal insulation on Duct aluminium faced thickness 22/24 SWG with XPLE insulation 19 mm thick complete all as specified and directed.
Item No .41 Supply and fixing of GI Wire 6 SWG including taking down Old GI Wire 6 SWG complete all as specified and directed.
Item No .42 Supply and fixing of PVC drain pipe of 25mm dia complete all as specified and directed.
Item No .43 M&L for compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases splices etc built up from two or more beam or channel sections or angles with plates, including all lattice bar, stiffeners, gusset plates etc made of Fe 410-W (Gde-E- 250) quality - A, with and incl all machine works i. e. cutting, welding, drilling, grinding etc and applying two coats of synthetic enamel paint over a coat of red oxide paint including taking down old girder, complete all as specified and directed.
Item No .44 M&L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work, complete all as specified and directed.
Item No .45 M&L for XLPE insulated heavy duty electrical cables with aluminium conductor,1100 volt grade,cross sectional area 16 Sqmm 3 core including taking down old cable complete all as specified and directed.
Item No .46 M&L for XLPE insulated heavy duty electrical cables with aluminium conductor,1100 volt grade,cross sectional area 25 Sqmm 3 core including taking down old cable complete all as specified and directed.
Item No .47 Supply only, in replacement, of absolute HEPA Filter AAFH1 of size 610 x 610 x 300 mm having rated flow of 1700 CMH, pressure drop less than 25 mm WG and efficiency more than 99.97 down to 0.3 micron, including taking down old HEPA fitter complete all as specified and directed.
Item No .48 M&L for 50 mm bore gate valve cast copper alloy screwed down high pressure with clutch handle screwed both ends for Iron pipe including taking out of old unserviceable gate valve complete all as specified and directed.
Item No .49 All as per item No 48 (hereinbefore) but size 40 mm bore
Item No .50 All as per item No 49 (hereinbefore) but size 20 mm bore
Item No .51 Earthig complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised using galvanised iron strip 32x6mm as earthing lead by means of bolts, nuts, checks nuts and washers of galvanised iron of steel all as shown in electrical plate No 3 connect to earthing test point complete all as specified or indicatd including testing on completion.
Item No .52 Earth continuity conductor or main earthing lead fix to wall on batten or recess or chases or burried in ground or drawn in conduit /pipe or fix to pole or any other indicated situation for loop earthing extra as required but size 32 x 6 mm galvanised iron strip complete all as specified and directed.
Item No .53 Supply and fixing canvas connectionn from AHUs to supply and return duct all as direct.
N K BUILDERS
Pneumatic Engineers Pvt. Ltd.
M/s Vijay Airconditioning Pvt Ltd
Chauhan Associates
NAFREF ENGINEERS PVT LTD
AMIT ASSOCIATES
M P TYAGI ENGINEERS AND CONTRACTORS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .