Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC | L1 | Accepted-AOC Awarded being L1 | |
| 2 | L2₹24.9 L+₹4.0 L (19.0%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹25.4 L+₹4.4 L (21.2%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹28.4 L+₹7.5 L (35.7%)Rejected-Finance HOUSE NO 87 SHAH FAISAL ABAD DHOBI MOHALLA BATAMALOO SRINAGAR 190009 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190009 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹32.3 L+₹11.3 L (54.0%)Rejected-Finance 254 GOVT HOUSING COLONY CHANNAPORA SRINAGAR 190015 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190015 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹34.4 L
EMD Value
₹68,800
Closing Date
25 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 Wks Engrs
HQ 134 Wks Engrs PIN 914134 c/o 56 APO
REPAIR AND MAINT OF HT DISTRIBUTION SYSTEM AND ALLIED WORKS AT KHUNDRU AND KHANABAL GRN UNDER GE 861 EWS
2021_MES_481469_2
134 WE-29/2021-22
Open Tender
Civil Works
Item Rate
180 days
Srinagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 861 EWS
₹68,800
Yes
17 Dec 2021
3 Nov 2021
27 Nov 2021
3 Nov 2021
25 Nov 2021
10 Nov 2021
60 days
Amount
M&L Strip opening of transformer and removing the top cover for draining the transformer oil and taking out the core alongwith HT/ LT coils (windings) assembling the core after replacement defective part, HT/ LT coils heating varnishing, testing and housing accessories in transformer body and connection up filling in dehydrated new transformer oil and connecting, commissioning with existing electrical system HT/ LT on load of capacity not exceeding 200 KVA including taking down and refixing complete all as specified and directed by EIC. Note :- (i) Winding wire including labour for making coil and supply only of new spare for replacement of UNSV spare will be measured and paid separately. (ii) Transformer oil will be measured and paid separately.
Supply only of HT Bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal suitable for transformer of capacity upto 200 KVA complete all as specified and directed by Engr-in-Charge.
Supply only LT bushes porcelain Vitreous with brass spindle threaded with washers nuts, lacknuts and rubber seal for indoor/outdoor transformer of capacity not exceeding 200 KVA complete all as specified and directed by Engr-in-Charge.
Supply only Top gasket made of 3mm thick cork sheet with suitable holes for transformer including providing suitable size of bolts, nuts and washer for transformer top cover complete for any capacity upto 200 KVA.
Supply only Tapping switch/gear changer mechanism for variation of HT voltage in steps for transformer of capacity not exceeding 200 KVA .
Supply only breather assembly CI body of standard size filled with silica gel of transformer up to 200 KVA .
M&L for Winding of HT/LT coil of different type capacity and make of transformer with approved quality super enamelled copper wire/ strips of approved make of suitable gauge and number of turns alongwith allied materials like cork sheet, fibre glass insulations, paper insulations, cotton/ Empire tap and tube wooden blocks bolts, nuts and washer (Brass) soldering and other packing material etc. complete all as required at site or as directed by Engr-in-Charge.
M&L for Reconditioning of LT coil of aluminium/copper wound transformer by turning the old paper insulations, straightening the entire LT Strip providing new paper insulations of superior quality and making coil of suitable design as original complete all as specified and directed by Engr-in-Charge.
S&F (in repair) Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50/95 Sqmm 3 core complete all as specified and directed by Engr-in-Charge.
S&F (in repair) Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50/95 Sqmm 3 core complete all as specified and directed by Engr-in-Charge.
Supply, laying and testing in repair HT cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with aluminium conductor, 11000 volts grade cross section area 95 sqmm 3 core complete laid in trenchers, duct, passing through pipe, fixed to poles complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5m wide and depth beyond 1.5m but not exceeding 3 metre deep and getting out in loose/ soft soil, complete all as specified and directed by Engineer-in-charge.
Excavation in trenches beyond 1.5m but not exceeding 3 metre deep and getting out in any type of soil for laying of cable complete all as specified and directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engr-in-Charge.
Removing surplus soil to a distance n.exc 50m and deposited where directed at a level not exceeding 1.50 m above the starting point, complete, all as specified and directed by Engr-in-Charge.
Sand cushioning to underground cables 8cm thick before laying cable and 15cm thick after lying and streching the cable, complete all as specified and directed by Engr-in-Charge. Note :- For payment purpose punned thickness shall be measured.
Supplying and laying unreinforced precast concrete cable cover, class HV, type 2, flat, size 450mmx l80mm x 40mm, complete all as specified and directed by Engr-in-Charge.
Suply and fixing in replacement of GI strip 32x6mm, buried in ground upto 50 cm or fixed to wall with insulators etc for loop earthing including welding for joints complete all as specified and directed by Engr-in-Charge. Note : Earth work will be measured and paid separetely.
S&F (in repair) Supply and fixing in replacement GOD triple pole 11000 Volts, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked form ground level for current rating upto 200 Amps with dropout fuse complete all as specified and directed by Engr-in-Charge.
S&F (in repair) Pin type white, brown and green insulator including one galvansied mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm high, 150mm dia for 11000 volts grade, complete all as specified and directed by Engr-in-Charge.
S&F (in repair) Disc type insulator, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green two in series assembly for tension with tension clamps for conductors working pressure 11000 volts, complete all as specified and directed by Engr-in-Charge.
S&F (in repair) Stay assembly, 20mm stay rod complete with accessories as shown in electrical plate No 1. All as speceified and directed. Note :- (Loop type insulator stay clamp Excavation and concrete work shall be measured and paid seprately)
M&L for cradle ground, hexagonal/ rectangular, fabricated with galvanized steel wire of 4mm dia for road crossing etc. All as specified directed.
S&F (in repair) Loop type insulator, vitreous, porcelain, white, brown or green insulator large size, with over all dimensions 90 x 140 mm, clearance of hole 25.5mm, complete all as specified and directed by Engr-in-Charge.
S& F in repair Galvanised stay strand, size 7/4 mm complete all as directed including taking down the old unserviceable stay wire, complete all as specified and directed by Engr-in-Charge.
S&F (In repair) Aluminium conductor steel reinforced any size in over head lines on HT poles including stretching the aluminium conductor and binding with binding wires of aluminium or aluminium tapes etc. jumpers and connections, complete all as specified and directed by Engr-in-Charge. TYPE of Aluminium Conductor : Rabit, Wolf.
S&F (in repair) Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engr-in-Charge.
Stretching the aluminium conductor on overhead line of HT pole and binding with binding wires of aluminium or aluminium tapes etc. jumpers and connections, complete all as specified and directed by Engr-in-Charge. Note :- (a) Necessary shut down to be taken by contaractor from 33 KV/ 11 KV MRS before performing the repair. (b) Stretching of each conductor between two pole will be treated as one job.
M&L Earthing complete with copper earth plate electrode 600x600x3.15mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.25mtr below normal ground level connected to the copper strip 20x3mm size by means of bolts ,nuts,check nuts and washers of copper and 20x3mm Copper strip protected by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mesh and medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I all as specified and directed. Notes:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 metres length shall deem to be included in the unit rate quoted against this item. (ii) GI protection pipe & earthing lead beyond 7.5 metres shall be measured and paid for seperately under appropriate item of BOQ (iii) On testing after completion if desired resistanace is not obtained, the contrator shall redo the earthing without any extra cost to the department.
M&L for servicing of HT 11KV, VCB installed at various locations including calibration by dismantling, cleaning, greasing the complete VCB with attached relays, bus bar etc. insulation testing, setting the contractor gap by measuring as required, reassembling the VCB and reinstalling back to its original position checking repairing the current, circuit panel wiring, relay testing (i.e. Primary and Secondary injection test)/ setting of relay rating in 06 months intervals of all CT's and submitting the test report to Engr-in-Charge including provision of new spares as required complete including operational testing and commissioning all as directed. Note :- (a) New spares, if required for repair/ service of VCBs will be measured and paid separately. (b) Caliberation of relays and primary and secondary injuction test shall be conducted by authorises company/ manufactures. Certificate of authority shall be produced by the OEM authorised company.
Supply only for replacement of the following spares for VCBs 33/11 KV of any make all as directed :
Resin encapsulated Vacuum bottles suitable for 11 KV VCB panel of cap 400 Amp up to 25 KA as per existing.
Clossing coil 30V DC
Tripping coil 30V DC
11 KV porcelain bushing for VCB Top/Bottom
S&F in repair of indicator bulb 20watt 1100 volts as per existing and make & specification suitable for 400 amps VCB, including necessary connections .
Suppy and fixing in replacement of epoxy resin cast CT dual core of ratio as per existing accuracy class .055 buden 200/100/05vA for 11 KV complete Make:- Vishal/Crompton/concord
Operating switch (ON-OFF Lever)assembly
Manual charging/operating gear system assembly with operating handle of complete assembly
Digital type Earth fault & over current relay equivalent of L&T Mode No MC61A 24-110V
S&F (in repair) Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engr-in-Charge.
Disconnecting HT/ LT side electrical connection carefully existing 11 KV/ 440 Volt stepdown transformer of any capacity, draining out and refilling of existing transformer oil after filtration dehydration and measuring the dielectric strength not less than 40 KV at 2mm gap including reinstallation of transformer satisfactory on its original position connecting testing and commissioning complete all as directed by Engr-in-Charge.
Supply and filling of Fresh transformer power oil of BDV not less than 45KVA for topping up reduced level due to evoporation/leakage/loss due to dehyderation in HT transformer complete all as specified and directed by Engr-in-Charge. Make : Power link/ Power oil/ Savita/ Midel
Replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous, enamelled white with letters. figures and conventional skull and bones in signal red colour and fixed with MS clamps made of 25x3mm MS flat, bolts and nuts for HT 25 x 20 cm size complete all as directed including taking down old danger notice plate, complete all as specified and directed by Engr-in-Charge.
S & F cable route indicator made out of 50x50x6mm angle iron, 60 mm long embedded in PCC block of suitable size with moulded letter ''HT cable'' suitable inscribed including PCC 1:3:6 type C2 (Using 40 mm graded aggregate block of 150x150x150mm size complete all as specified and directed by Engr-in-Charge.
Supply and laying 20mm thick graded coarse aggregate all around of the HT poles/ feeder panel/ station etc of bed 45cm thick, complete all as specified and directed by Engr-in-Charge.
M&L for GI tubing light grade 80 mm dia with all fittings laid in trench or fixed on wall, along pole for protection of cable complete all as specified and directed by Engr-in-Charge.
S &F in replacement of Lighting arresters expulsion type complete with all fittings, suitable for volts 11000 V and discharge capacity 65 Kilo Amps complete all as specified and directed by Engr-in-Charge
M&L for Steel tubular swaged poles 11 meter long, type 410, SP-55 with 300mm x 300mm x 6mm mild steel base plate, finial taper plug, bolts, nuts and screws duly painted with two coats of anti-corrosive paint internally and externally complete including alternate black and yellow strips of 30 cm each of synthetic enamel paint upto 1.50 metre from GL and remaining external portion of pole painted with aluminium paint including writing number including dismantling and removing thereof old U/S steel HT pole, complete all as specified and as directed by Engr-in-Charge. Note : Excavation, earthwork and PCC shall be measured and paid separately
Plain cement concrete, (1:4:8), type D-2( using 40mm graded crushed stone aggregates) as in foundation filling & mass concrete for pole complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, (1:3:6), type C-1( using 20mm graded crushed stone aggregates) as in foundation filling & mass concrete for stay complete all as specified and directed by Engr-in-Charge.
Painting of HT pole applying two coats of synthetic enamel paint over one coat of redoxide zinc chrome primer. (Painting of one pole is treated as one job)
Plain cement concrete (1:2:4), type B-1 (using 20mm graded crushed stone aggregates) as in coping filling including necessary form work through finised all as specified and directed by Engineer-in-Charge.
Preparation of old steel surfaces of XPM jali and angle iron fixed on transformer plinth up to 100 KVA and painting with two coats of synthetic enamelled paint over a coat of red oxide primer and two coats of colour wash over a coat of white wash on plastered surface complete all as specified and directed by Engr-in-Charge.
Taking out old unserviceable cable of any size and type complete all as specified and directed by Engr-in-charge.
S&F Chemical earthing with copper earth plate 90 x 60 x 5mm and copper earth strip 32 X 6 mm main, burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5 mtr deep below normal ground level with top edge of earth plate not less than1.5mtr below normal ground level connected to the galvanised iron wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised steel all as shown on electrical plate No 3 of MES Sch 2009 Part-1 connected to earthing test point and testing on completion with and including necessary excavation and earthwork, earth electrode, earthing lead from electrode to eqpt/ sub stn, adequated quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 using 20mm graded black trap/granite/basalt stone aggregate, 40mm thick cover reinforced with 8mm dia bar 4 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20mm bore with funnel and wiremesh and 15mm dia GI light grade earth lead protection pipe upto equipments max length 7.5 mtr complete all as specified and directed by Engr-in-charge. On testing after completion if the desired resistenance is not obtained the contractor shall re do the earthing without any extra cost to the department.
M&L Earthing complete with GI steel earth plate electrode 600x600x6mm, burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5 mtr deep below normal ground level with top edge of earth plate not less than1.5mtr below normal ground level connected to the galvanised iron wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised steel all as shown on electrical plate No 3 of MES Sch 2009 Part-1 connected to earthing test point and testing on completion with and including necessary excavation and earthwork, earth electrode, earthing lead from electrode to eqpt/ sub stn, adequated quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 using 20mm graded black trap/granite/basalt stone aggregate, 40mm thick cover reinforced with 8mm dia bar 4 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20mm bore with funnel and wiremesh and 15mm dia GI light grade earth lead protection pipe upto equipments max length 7.5 mtr complete all as specified and directed by Engr-in-charge. On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
M&L for replacement of copper strip of size 20mm x 3mm fixed to wall on batten, recess, chases or burried in ground, drawn in conduit/pipe, fixed to poles or any other indicated situation for earthing complete all as specified and directed by Engr-in-Charge.
M&L filling in with new transformer oil low viscosity of approved make as per IS-335 of 1993 and die-electric strength 30 KV when tested at 4mm gap complete all as specified and directed by Engr-in-Charge.
Supply and Fixing 4mm dia galvanised steel wire (Chain link) 100x100mm mesh, 1.8 mtr high and 14 m long made up into mattresses or cages, lapped wired and laid in position, including excavation in post holes of require size, getting out, returning filling in and ramming and removing, including cement concrete type C2 1:3:6 (40mm graded aggregate) in mass concrete filling in holes to support angle size of concrete is 0.45x0.45x0.60CM complete, including mild steel work as in posts and struts in fencing drillings holes notching for wire etc flat iron fillets with 8 nos iron angle of size 65x65x6mm up to 1.8 mtr high and 60cm in PCC under ground, including applying two coats of synthetic enamal paint over one coat of redoxide zinc chrome primer.
M/S NORTHERN ELECTRICAL WORKS
M/S STARE BUILDERS
M/s Lal Enterprises
M/S Sky Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .