| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹12.5 L+₹16,845 (1.37%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest bidder | |
| 3 | L3₹12.7 L+₹44,335 (3.60%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest bidder |
Tender Value
₹14.9 L
EMD Value
₹29,900
Closing Date
19 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur
ROUTINE PREVENTIVE AND CORRECTIVE MAINTENANCE OF SEWAGE SYSTEM INCLUDING CLEANING OF SEPTING TANK IN VARIOUS OTM BLDG AND LIVING IN ACCN UNDER AGE BR II AT AFS CHAKERI KANPUR
2022_MES_564212_1
GE(AF)/CHK/T-45 OF 2022-23
Open Tender
Civil Works
Item Rate
330 days
GE(AF) B/R Chakeri Kanpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) B/R Chakeri Kanpur
₹29,900
Yes
10 Jan 2023
21 Nov 2022
26 Dec 2022
21 Nov 2022
19 Dec 2022
5 Dec 2022
Amount
Dismantling of brick work of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M & L for brick work old size with sub class `B` bricks in cement mortar straight or curved on plan exceeding 6 m mean radius built in CM (1:4) provided complete all as specified and directed
Ditto all as per item No. 2.00 above but except bricks.
M & L for rendering 15 mm thick in CM (1:4) on brick work or concrete surfaces, finished even & smooth without using extra cement, with water etc, complete all as specified & directed.
M & L for rendering 15 mm thick cement plaster in CM (1:6) on other than fair faces brick work finished even and smooth without using extra cement including taking down old cement plaster, complete all as specified and directed.
M & L for rendering 5 mm thick cement plaster in CM (1:3) on fair faces brick work finished even and smooth mixed with water proofing compound (@ 3 % by wt of cement) without using extra cement and applying three coat of white wash on ceiling after preparation of surfaces including taking down old cement plaster complete all as specified
M & L for preparation of new undecorated surfaces of walls and applying two coat of oil bound distemper over a coat of primer over and including 1 mm thick (average) wall care putty complete all as specified and directed.
M & L for preparation of new undecorated surfaces of walls and applying two coat of cement based paint over a coat of primer complete all as specified and directed.
Demolition of reinforced cement concrete of any description complete all as specified and directed.
Demolition of cement concrete (Unreinforced ) of any description and in any position not otherwise specifically described for complete all as specified and directed.
M & L for precast RCC (1:2:4) type B-2 using 20 mm graded stone aggregate as in manhole cover / drain covers set in CM (1:6) etc complete all as specified and dircted.
M & L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete etc complete all as specified and directed.
M & L for PCC (1;3:6) type C-2 using 40 mm graded stone aggregate as in surface channel and drain, complete all as specified and directed.
M & L for PCC (1;3:6) type C-2 using 75 mm thick as in flooring /paving/plinth protection including finishing even & smooth without using extra cement complete all as specified and directed.
Demolition or breaking up drain pipes of 150 mm dia (SGSW/AC or reinforced concrete) set in cement mortar including breaking and removal of bedding and hunching complete all as specified and directed.
Ditto all as per Item No 16.00 above but for with 200 mm dia
M & L for 150 mm bore RCC Pipe class NP-2 lwith collars laid and jointed in CM (1:3) complete all as specified and directed.
Ditto all as per Item No 18.00 above but for 200 mm dia pipe
Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m depth & getting out in any type of soil complete all as specified and directed.
Returning and filling in including spreading and levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr from the starting point complete all as specified and directed.
Cleaning of the blocked sewage lines by rodding between manholes and removing muck sludge/silt/liquid mud etc (incl foul position) from pipes & MH including taking down cover slab of any type, thickness and size carefully and re-fixing in same position after necessary cleaning and removing the cleaned sludge out side of MD land in sealed containers complete all as specified and directed.
Dewatering & Cleaning of septic tank/ soakage well at diffrent locations of any description up to any users capacity by mechanically only with using sewage tankers/truck mounted hydraulic jet pressure mehanism with heavy duty flushing the sewage line with heavy duty sewage suction pump including necessary arrangements such as sweepers to clean up the site after work in the following steps :(i) Bailing out /dewatering of septic tank ,soakagewell (ii) Removing of all sludge/waste material (liquid/semi liquid /solid/semi/solid) silt, bricks bats debris mud soil , polythene etc any kind of materials from all chambers of the septic tank,soakage well, clean the floor and walls of the tank after removing the same complete(iii) Removing the blockage of inlet/outlet pipe in any depth , in any situation (iv) Finally flushing septic tank /soakage well including inlet/outlet with adequate water and making fully functional the septic tanks/soakage well with entire satisfaction of Engineer-in- charge and removing retrieved/takingout all type materials , sludge/soil waste liquid/semi liquid /solid/ semi solid/ or any unwanted materials of any kind etc outsidethe periphery of defence land at his own arrangement in packed container where sanitary hazards do not take place as per directions/instructions of civil authority and buried in excavated pits in suitable size and depth and covering the same with the soli obtained from excavation of pit including all excavations and earth work including applying bleaching powder to maint hygiene. Adequatewater for flush out sludge to be arranged by the contractor without any extra cost and including taking out manholes cover and re-fixing the same after cleaning/removing blockage, fully functional complete all as specified and directed. Note :- A particularr septic tank/soakge well which is undertaken once for cleaning and paid for shall be kept function or entire contract period and no extra payment shall be made for repetitive cleaning if required.
Supply only integral water proof compound complete all as specified and directed.
M & L for RCC(1:2:4) Type B-1 using 20 mm graded granite stone aggregate for slabs supported on walls, beams and columns, in floors, roofs, landings and in shelves and the like including necessary form work complete all as specified and directed.
Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (half round or thre forth section ) in PCC (1:2:4) type B-1 using 20mm graded stone aggregate smooth finished and reforming benching as required complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips qual complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed.
M & L for 100 mm thick PCC (1:4:8) Type D-2 using 40 mm graded stone aggregate as in sub base and mass concrete complete all as specified and directed.
M & L for providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawn, drive ways or light traffic parking etc, of required strenth, thickness & size shape mady by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in copings and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
S & F 1.60 mm thick mild steel plain ,black sheet in hearths covering to door shutters ,covering to door chowkhats (Frame for water tank) water throughs ducts etc cut to size edges beaded if directed holes punches fixed to wood or steel members etc complete all as specified and directed .
S & F framed brackets of angles or tees with web and flanges cut to shape , drilled and countersunk for screw, including bending and welding angles as necessarry gusset plates riveting, etc not exceeding 10 kg each bracket confirming to Fe-290 Grade -E 165 (brackets over 10 kgs each to be measurd under structural steel) induling disamntling of old steel work complete all as specified and directed .
M & L for providing two coat of master seal 550 (Two component acrylic modified cementious coating coverage 1.80 Kg/Sqm for 1mm thick layer) of BASF or equvalient make in Fosroc /Sika to prevent leakage /seepage through sunken floor over prepared surfaces complete all as specified and directed.
M & L for PCC (1:5:10) type E2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
S & F in repair 40 mm dia GI tubing medium grade galvanised with all fittings under floor as spout pipe complete all as specified and directed.
S & F in repair Vitreous china squatting pan 'orrisa' pattern size 580mm x 440 mm white integral floor rests ( excluding flushing cistern ) including connection to trap and to flushing pipe anti syphonage pipe etc complete including making good to floor, complete all as specified and directed.
S & F in repair vitreous china urinals, Half stall type, white with grating union for discharge pipe of wall type complete including providing and fixing plugs, bedding urinal against wall in CM(1:2), securing urinal to plug with and including 60 mm long brass screw pointing around urinal back in cement, fixing automatic flushing cistern with brackets flush pipe grating and union for discharge pipe, complete all as specified and directed.
Rectify sewage system complaint in daily routine basis as per complaint lodged by user at complaint cell of AGE B/R-II sub division chakeri by deploying manpower by cleaning/clearing/removal blockage such as blockage /chocked in any type size/height/depth/location of WCs/urinal/bathroom /kitchen/WHB along with any type/size/height/depth bore of outlet SGSW/PVC/CI/UPVC/RCC etc pipe and including all kind of traps such as inspection chamber/floor/nahani/gully/intercepting/bottle trap/P,S/multi floor traps of any SGSW/PVC/CI/UPVC etc description and in any position below or above ground level,in any floor,located in different situations,including opening the clearing eyes of sewage waste pipes/vent pipe etc,opening the access cover/granting and taking out/removing all material such as sludge/soil waste/sludge water/polythene/mud/slit/ liquid/ semi liquid/semi solid/ solid/ bricks bats/ debris/ soil etc any unwanted materials of any kind etc and also cleaning/ removal blokage up to Ist manhole /sewage line etc in any type/size/height/depth/location/pattern including flushing with adequate water after cleaning make the all system fully functional to the entire satisfaction of Engr-in-Charge, re-fixing the existing opened access cover and removing all retrieved material/ unwanted/ foreign material in any liquid/ solid state etc outside the periphery of defence land at his own arrangement where sanitary hazards do not take place as per directions/instructions of civil authority and buried in excavated pits in suitable size and depth and covering the same minimum 25cm thick compacted layer of soil with the soil obtained from excavation of pit including all excavations and earth work including applying bleaching powder to maintain hygiene. adequate water for flush out to be arranged by the contractor without any extra cost complete all as specified and directed.
S & F in repair PVC connection of 15 mm dia with PTMT nuts of length 450mm, complete all as specified and directed.
S & F in repair PVC waste pipe 32 mm bore for WHB/Urinal complete all as specified and directed.
S & F in repair 10 ltrs capacity PVC valveless, symphonic action type, flushing cistern, low level, with inlet ,ball valve, float and handle including flush pipe (long bend) for low level cistern complete all as specified and directed.
S & F in repairs vitreous china wash down water closet pan (pedestal pattern), including necessary fittings complete all as specified and directed.
S & F in repairs vitreous china WHB ,white or coloured, size 550 mm x 400 mm with 32 mm dia CP waste coupling and all fittings and fixtures complete all as specified and directed.
S & F in repair 15 mm bore small GI fitting/articles like socket, elbow, reducer, unions, nipple(not more than 150mm long), long screw and other articles complete all specified and directed.
S & F in repairs 15 mm dia Ball valves high pressure with polythene float and fly nut complete, screwed for for iron pipe or brass ferrule complete all as specified and directed.
S & F in repairs 20 mm dia Ball valves high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
S & F in repair 15 mm bore Bib taps standard of PTMT any colour high pressure screwed for iron pipes and fixed (minimum weight 15 mm- 90 gms complete all as specified and directed.
S & F as in repair 15 mm dia bib cock ,chromium plated, cast copper alloy ,fancy type with capstan head screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repairs 15 mm bore pillar taps fancy type chromium plated screw down high pressure with long screwed shanks and fly-nuts, screwed for iron pipe all as specified and directed.
S & F in repair 15 mm bore Pillar taps of PTMT any colour high pressure screwed for iron pipes and fixed (minimum weight 15 mm- 110 gms) complete all specified & directed.
S & F in repair 15 mm bore Stop Valve of PTMT any colour high pressure screwed for iron pipes and fixed (minimum weight 15 mm- 90) gms complete all as specified & directed.
S & F in repair 15 mm bore Angle Valve of PTMT any colour high pressure screwed for iron pipes and fixed (minimum weight 15 mm-110 gms) complete all as specified & directed.
S & F as in repair 15 mm dia angle cock/stop cock, chromium plated, cast copper alloy, screwed down high pressure, screwed both ends for iron pipe or for union complete all as specified & directed.
M & L for glazed ceramic colour tiles on vertical surface of size 350 mm x 250 mm x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick rendering in CM (1:4) complete all as specified and directed.
M & L for 7 to 8 mm thick Non - skid Ceramic colour tiles (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc. set and jointed in neat cement slurry over and including 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
Dismantling floor, hearth or wall tilling including cement mortar beading (but not backing), removing serviceable tiles to store and rubbish off the premises.
Taking down 15 mm dia GI steel tubing and connection including cleaning for re-fixing or removal ,complete all as specified and directed
Re-fixing of 15 mm bore old steel tubing and connection in new or old position fixed I wall or floor, ceiling etc complete all as specified and directed.
M & L for GI Tubing 15 mm dia ,medium grade galvanised ,with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and directed.
Taking down 20 mm dia GI steel tubing and connection including cleaning for re-fixing or removal ,complete all as specified and directed
Re-fixing of 20 mm bore old steel tubing and connection in new or old position fixed I wall or floor, ceiling etc complete all as specified and directed.
M & L for GI Tubing 20 mm dia ,medium grade galvanised ,with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and directed.
S&F Low density polyet?hylene pipes (LDPE)32mm bore of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed.
S&F Low density polyet?hylene pipes (LDPE)40mm bore of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as speceified and directed.
S&F Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/ 40mm-270 gms) complete all as specified and directed.
S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed.
S&F PVC (SWR) pipes single socketed 110 mm of bore in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) pipes single socketed75 mm of bore in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) bends any radius 75mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius 110mm bore complete all as specified and directed.
PVC (SWR) branch piece, single (single Y) equal or unequal 110mm bore complete all as specified and directed.
S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm dia if out let complete all as specified and directed.
continentalconstructionco.
JEEWAN BUILDERS AND ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .