Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC | L1 | Accepted-AOC Being a lowest bidder and reasonable rate quoted | |
| 2 | L2₹20.5 L+₹2.9 L (16.3%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹21.2 L+₹3.6 L (20.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹21.7 L+₹4.1 L (23.5%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹22.4 L+₹4.8 L (27.3%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹17.5 L
EMD Value
₹35,000
Closing Date
14 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PULGAON
GE PULGAON
REPAIR REPLACEMENT OF B/R WORKS AND EM WORK IN RA ZONE A AREA AT CAD PULGAON
2022_MES_501835_3
8944/PUL/E8
Open Tender
Civil Works
Item Rate
180 days
GE Pulgaon
AS PER TENDERDOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
₹35,000
Yes
24 Mar 2022
4 Mar 2022
19 Mar 2022
4 Mar 2022
14 Mar 2022
9 Mar 2022
4 Mar 2022 - 5 Mar 2022
60 days
Amount
Demolition of cement concrete (un-reinforced) in ground floors and paving n.exc 15 cm thickness (below or above ground level) and removing salvage to a distance not exc 50 m complete all as specified and as directed.
M&L 75mm thick PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection laid in alternative bays not exceeding 3 metres in length including filling of joint with bitumen mastic (1:3) complete all as specified and as directed.
M&L Cement concrete 25mm thick type B-0, 1:2:4 (12.5 mm graded aggregate) as in floor leveling course complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing the rubbish off the premises complete all as specified and as directed.
M & L for Glazed ceramic coloured tiles of size 450 mm X 350 mm X 7 mm thick as on vertical surfaces such as skirting, dados and rises to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over 10 mm thick CM 1:4 all as specified. complete all as specified and as directed.
M & L for Non skid ceramic coloured tiles (square / rectangular) of 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exc. 0.18sqm as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over 15 mm thick screed bed (1:6) CM complete all as specified and as directed.
M & L for Non skid ceramic coloured tiles (square / rectangular) of 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exc. 0.18sqm as in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over 10 mm thick plaster (1:4) CM complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary formwork required complete all as specified and as directed.
M&L Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System with 19mm thick Microlook 90 Edge Ultima Tiles with 15mm face exposed grid. The tiles shall have smooth bright laminated visual with Humidity Resistance (RH) of 99%, NRC 0.75 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 36db as per ASTM E1414, Light Reflectance ≥85% as per ASTM E-1477, Thermal Conductivity k = 0.045 - 0.048 W/mK, Colour Global White, Fire Performance of class A2-s1, d0 according to EN 13501-1 with 19mm Square Tegular/Microlook 90˚ edge and 8mm drop in module size of 600 x 600mm. The scrim on the face of the tile shall be cleanable, soil and scratch resistant and having superior scrub-ability (Gardner Test). The tiles shall be classified as ISO 14644-1 cleanroom class 5. The tile shall have a rating of 8 or above for tests conducted for Resistance to growth of Mold in accordance to ASTM D3273. It shall be suitable for Green Building application, with Recycled content of 36%. The tile shall have certifications from GRIHA and GreenPro thereby confirming that it is an environment friendly product. SUSPENSION: The tile shall be laid on with 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. All border cross tee/main beam shall be levelled using perimeter fill and Including Dismatling old existing False ceining any discription complete The supply shall be backed by a Manufacturing Test Certificate. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications above) at 1200mm maximum. The First/Last suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall. Note : The work to carried out up 6 mtr to 8 mtr height from the GL by providing necessary scaffolding
M&L for Brick work with fly ash modular bricks straight or curved on plan exc 6m in radius but built in 1:6 cement mortar and including demolition of brick complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls or from concrete surface incl raking out joints, hacking for key, scrubbing down with water etc all as specified,and removing unserviceable material outside the premises complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 on finished even and smooth with out using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick or concrete surfaces for CM 1:4 on finished even and smooth without using extra cement all as specified. ( incl all necessary scaffolding, lifting arrangement for three story building on external surfaces) complete all as specified and as directed.
M&L for oil bound distempering two coats over a coat of wall care putty including preparation of new plastered or unplastered surfaces of wall complete all as specified and as directed.
M&L for cement base paint two coats over one coat of wall care putty including preparation of new plastered or unplastered surfaces of wall complete all as specified and as directed.
Taking down carefully concealed/ casing caping point wiring (light/ fan / socket) complete (with fittings such as switches ceiling rose, pendents, regulators sockets etc) and making good disturbed surface with exisitng specification all as specified and as directed.
M&L point wiring complete with 1.5sqmm single core sheathed PVC insulated FRLSH cable 1100 V grade multistranded copper conductor of different code of ISI marked drawn through and incl PVC conduit of suitable size with accessories ISI marked incl PVC insulated copper cable for earth of same type and size connected to earth dolly including provision of PVC box of suitable size for mounting switches / sockets and fan regulators etc complete all as specified and as directed for One light point controlled by one switch one way.
All as per item No 24.00…. But for one ceiling fan / exhaust fan / wall mounting fan point controlled by one switch one way
All as per item No 24.00…. But for one socket outlet three pin 5/6 Amps controlled by one switch on the same board.
All as per item No 24.00…. But for one switch socket outlet three pin 5 /6 Amps controlled by one switch on independent board.
M&L for point wiring with stranded copper conductor 2.5 Sqmm (nominal area), single core, multistranded, FRLSH , PVC insulated and sheathed cabel 1100 volts grade, ISI marked drawn in and incl PVC casing caping of suitable size with accessories ISI marked incl PVC insulated copper cable for earth of same type and size connected to earth dolly including provision of PVC box of suitable size for mounting complete all as specified and as directed.
M&L switch piano flush type single pole,one way, 5 Amps, 240 V complete all as specified and as directed. Make : Anchor/Havells/Cona
S&F socket outlet 5/6 pin type,5 Amps, 240 V complete all as specified and as directed . Make : Anchor/Havells/cona
Supply & fix switch socket combination flush type 2 and 3 pin, 5 Amps, 250 volts, AC, multipurpose complete all as specified and as directed.
S&F switch socket combination flush type (multipurpose type) but 15A/16A, 5 in 1 15 Amps, 240V complete all as specified and as directed.
S&F ceiling rose surface type with 3 terminals complete .Make : Havells/SSK/Cona
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. all as specified and directed including taking down U/S old any type of TL fitting. Make Havells /Philips/Bajaj .
S&F in replacement of sheet steel enclosure with double door flush mounting ,MCB, DB, TPN 12 ways,415 volt factory fitted rated bus bars,earth bar,neutral links complete incl. blanking plates as required & making good the disturbed surfaces including taking down old one. Make : Havells/legrand/Schneider
S&F in replacement of MCB TPN 40 Amps 240V ,50 Hz ,breaking capacity 10 KA," C " series. Make:Havells/Legrand/Schneider
S&F in replacement of sheet steel enclosure with double door flush mounting ,MCB, DB, SPN 4 ways,240 volt factory fitted rated bus bars,earth bar,neutral links complete incl. blanking plates as required & making good the disturbed surfaces including taking down old one. Make : Havells/legrand/Schneider
S&F in replacement of MCB SPN 40 Amps 240V ,50 Hz ,breaking capacity 10 KA," C " series. Make:Havells/Legrand/Schneider
S&F in replacement of MCB SP 06-32 Amps 240V ,50 Hz, breaking capacity 10 KA," C " series. Make:Havells/Legrand/Schneider
M and L for sub main wiring 2 run of 4 sqmm PVC FRLSH copper cable and one run of 4 sqmm PVC FRLSH copper cable for earth wire multistranded single core cable in PVC conduit 20mm dia pipe complete all as specified and as directed. Note :- (i) 2 runs of wire and 1 run of earth wire will be measured as one unit. (ii). Groove Cutting ,pinning and plastering of disturbed surface etc shall deemed to be included in the quoted rate.wiring 2 run of wire and1 run of earth wire
Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below ground level connected to galvanized iron earth lead wire 4.00mm dia by means of bolts, nuts, check nuts, washers of galvanized iron and connected to main switch/control board upto 7.5m away from the earth electrode including excavation earth work, PCC 1:3:6 type C-1 chamber, pre-cast RCC cover 40 mm thick 1:2:4 reinforced with 8 mm dia TMT bars 100 mm centre to centre both ways slab, char coal, 20 mm bore medium grade watering pipe, funnel with wire mesh, lugs, earth lead protection pipe 15mm bore medium grade 7.5m long as applicable and as per plate No. 3 of SSR Part-I 2009 and all as specified including excavation, earthwork and taking down old one.
Supply and fix down lighter LED of 36 Watt indoor type, cool day light 2ftx 2ft slim panel with super bright highly efficient light smoothing optics to deliver superior illumination and energy savings complete including taking down old one. Cat Part No. CCR-127-36-57SLNWH Make Crompton or equivalent in Bajaj/philips as directed by Engr-in-Charge
Supply and fixing building street lights LED of 35/36 Watt IP-65 outdoor type suitable luminus complete including necessary brackets suitable size, clamps and three core wire not less than 1.5 sqmm and taking down old one, and fixing at suitable hight not less than 5.5 Mtr.as directed by Engr-in-Charge Make :Bajaj/CG or equivalent
Ankit Construction
RAJ ENTERPRISES
M/S L M Chourasia
SHREE CONSTRUCTIONS
SHREE SIDDHIVINAYAK TRADERS
Arnav Enterprises
Bidder Name
M/S L M Chourasia
Ankit Construction
RAJ ENTERPRISES
SHREE CONSTRUCTIONS
SHREE SIDDHIVINAYAK TRADERS
M/S Ramakant Chourasia
Arnav Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .