| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹25.1 L+₹1.5 L (6.41%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹25.4 L+₹1.8 L (7.54%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹27.8 L+₹4.2 L (17.7%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹29.1 L+₹5.5 L (23.3%)Rejected-Finance 275 2 AJIT NAGAR UPPER GADIGARH AIR PORT ROAD JAMMU INDEX NO D 04 ADGNJ | JAMMU | JAMMU AND KASHMIR | 180001 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
4 Mar 2024, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
PROVN OF ROOF TREATMENT OF CERTAIN OTM ACCN AND CERTAIN MINOR WORKS AT NAGROTA MIL STN UNDER GE NAGROTA
2024_MES_640921_1
GEN-8581/E8
Open Tender
Civil Works
Item Rate
180 days
NAGROTA
CLASS D CATEGORY a i
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹93,000
Yes
2 Jul 2024
6 Feb 2024
12 Mar 2024
6 Feb 2024
4 Mar 2024
21 Feb 2024
Amount
SCHEDULE A PART -I Dismantling of Brick tiles, brick bats and taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100 m but n.exc.250m. complete all as specified and directed.
M&L for 10 mm rendering in CM 1:4 including water proofing compound @2% of cement over roof surfaces finished even and smooth without using extra cement complete all as specified and directed Note:- WPC Mesured and Paid Separately.
Supply only for Integral water proofing compound.complete all as specified and directed
M&L for Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces complete all as specified and directed
M&L for Applying evenly a tack coat of induatrial bitumen 85/25 grade @ 1.2 Kg/Sqm. complete all as specified and directed
M&L for One layer of APP based polymeric membrane of approved manufacturer, 3mm thick, weight not less than 3.50 Kgs per Sqm , reinforced with non woven polyester fabric or weight not less than 150 gms per Sqm . Polymeric membrane shall be taken to a height 60 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing(Note (i) Laying of APP based polymeric membrane shall be done by torch on method or as per manufacturers instructions (ii) A Minimum overlap of 100 mm and 75 mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufacturers instructions (iii) The make of polymeric membrane shall be IWL India Ltd chennai. Ltd or "MOPLY FP" of Texsa India Ltd). NOTE : S&F of APP based polimeric membrane of approved manufacturer will be laid/fixed by authorised person of the same manufacturers units asper relevent IS.
Applying one coat of aluminium paint on top of APP membrane.
Dismantling and breaking up PVC Rain water pipes of 75/100mm bore jointed in CM and taking out of Wall/trenches.complete all as specified and directed
S&F 110mm bore PVC pipe single socketed in any length with rubber ring joints, fixed to walll and or in floors, fixed in repairs.complete all as specified and directed
S&F for PVC (SWR) with access bends 110mm bore complete all as specified and directed .
S&F in repairs Stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof for 100 mm bore complete all as specified and directed
PCC 1:2:4 type B-0 (12.50mm graded aggregate) as in padding finished even and smooth without using extra cement all as specified and directed.
Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles complete all as specified and directed .
Demolition of Concrete (Unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster etccomplete all as specified and directed
M&L for Brick work with sub class “B” bricks straight or curved on plan exc 6M mean radius build in CM 1:6 using all as specified using old size bricks complete all as specified and directed
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement all as specified
M&L for Rendering 5 mm thick in CM (1:3) on ceiling finished even and smooth without using extra cement including three coats of white wash on ceiling including preparation of new surfaces complete all as specified and directed
M&L for Preparing newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed
M & L preparing new plastered surfaces of ceiling chajjas facia etc. and applying three coats of white wash complete all as specified and directed .
Preparation of old decorated plastered or unplastered surfaces of walls by brooming down or by steel wire brushes, scraping down smoke spot, moulds, moss and efflorescent salts, trading oil, greasy spots etc and applying two coat of cement base paint on walls after filling any hole with putty complete all as specified and directed
All as per item No 21 above here in before but applying one coat of exterior emulsion paint on plaster surfaces on chajjas/band/facia/balcony etc upto four storied bldg complete all as specified and directed
M & L for Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) Exc 250 and n exc 500 ltr complete all as specified and directed
M & L for Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) Exc 500 and n exc 1000 ltr complete all as specified and directed .
Dismantling water tank and removing to stores exc 500 ltr n.exc 1000 ltr complete all as specified and directed
Dismantling water tank and removing to stores exc 250 ltr n.exc 500 ltr complete all as specified and directed
S&F 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part I.complete all as specified and directed
S&F 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part I.complete all as specified and directed
Taking up or down 20mm bore steel tubing and connection including cleaning for refixing or removel to store.complete all as specified and directed
S & F 20mm dia GI tubing medium grade with all fittings and fixed complete to walls or laid in floors.complete all as specified and directed
SCHEDULE A PART -II Supply,installation,connecting, testing & commissioning Split AC 2 Ton capacity cold, reversible cycle non CFC refrigerant including cutting of wall /window & grouting of nut bolts frame 60cmx40cm of angle iron of size 40x40x6mm thick etc. for installation AC's. Making good disturbed surfaces by means of using sand, cement etc. complete all as specified & directed. (Note :- 1. A.C. Should be Minimum 3 star rated under BEE Label) 2. all items for fixing ACs such as Metal Stand for fixing external unit, PVC pipe 1/2'' for extension of drain pipe provided by contractor and rate for the same shall be deemed to be included in quoted rates complete all as specified and directed.
Supply,installation,connecting, testing & commissioning Split AC 1.5 Ton capacity cold, reversible cycle non CFC refrigerant including cutting of wall /window & grouting of nut bolts frame 60cmx40cm of angle iron of size 40x40x6mm thick etc. for installation AC's. Making good disturbed surfaces by means of using sand, cement etc. complete all as specified & directed. (Note :- 1. A.C. Should be Minimum 3 star rated under BEE Label) 2. all items for fixing ACs such as Metal Stand for fixing external unit, PVC pipe 1/2'' for extension of drain pipe provided by contractor and rate for the same shall be deemed to be included in quoted rates complete all as specified and directed.
Supply and Install automatic copper wound voltage stabilizer for low and high voltage correction equipped with electronic transistorised relay suitable for connection on single phase 50 HZ AC supply, designed for input voltage of 90 to 290 V and output voltage stablized at 215 to 240 V of Capacity 5 KVA complete with digital voltmeter and ammeter with time delay relay of 2-3 Minute complete all as specified and directed
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn in & incl PVC conduit of approrpriate dia complete all as specified and directed. (Note :- (a) PVC Conduit shall be included in same rate. (b) All the incomming and outgoing cable should be connected through proper lugs & sockets as per site requirement)
S&F Single pole & neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amp 240V complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 16 Sqmm 4 core in any position complete all as specified and directed
Supply and fix wall mounted Busbar chambers 415 V, 3 phase, 4 wire 50 Hz AC supply system fabricated from stainless steel with 3 mm thick for outer cell TPN aluminium busbar of cap 63 Amp 4 pole 6 way connected with proper Nut and bolt complete all as specfied and directed Make Havells cat Part No IHBC006306 or equivalent make as specified in PS
U K Engineering Works
M/S KALSI ENGINEERS AND CONTRACTORS
R.K. Works
GENESIS INDIA
KRISHNA BUILDERS
RAJINDRA ENGINEERS & CONTRACTORS
Karmnaya Construction
M/S. RAM PAUL KHAJURIA & BROS.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .