Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC R O KHREW TEH PAMPORE DISTT PULWAMA PIN 191103 J K | PULWAMA | JAMMU AND KASHMIR | 191103 | L1 | Accepted-AOC Being L1. | |
| 2 | L2₹7.3 L+₹33,835 (4.88%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹7.5 L+₹56,550 (8.16%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹8.6 L+₹1.7 L (24.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹8.7 L+₹1.7 L (25.1%)Rejected-Finance R O IQBAL MARKET AALI MAJID EIDGAH SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
11 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (K)
AGE (I) CIF (K) SHALATENG
REPAIR AND MAINT OF INTERNAL ELECTRIFICATION , AC , REFGS AND OTHER CONNECTED WORKS OF 10 SECTOR RR AND 29 RR BN UNDER AGE (I) CIF(K).
2024_MES_675451_1
AGE (I) CIF (K) - 41/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SHALATENG
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE (I) CIF (K)
₹18,000
Yes
4 Dec 2024
20 Sept 2024
14 Oct 2024
20 Sept 2024
11 Oct 2024
4 Oct 2024
Amount
Taking down copper /aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches , ceilling roses , holder , tube light , bulk head , pendants, regulators, sockets etc, removing materials to store for keeping in safe custody or for taking credit (Credit for above items should be made as per conditions separately) and making good surfaces , wall, floors etc.)
M& L in replacement of Point wiring for one light point / fan point or bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed, FRLS , Multistranded copper conductor cable as in and including non metalic rigid PVC concealed conduit ISI marked, not less than 20mm dia, mediun duty for one light, fan, bell pioint controlled by one switch including sunken steel boxes of suitable size with 3mm thick plastic laminated backelite sheet including FRLS PVC insulated unsheathed multistranded copper conductor cable of size 1.5sqmm (green colour ) as continious earth wire and connecting to earth dolly, and making good to distrub surfaces of wall/floor to match to existing finishes etc complete all as specified and directed. Note: The unit rate quoted include the cost of cutting chases in surfaces for conduits and fixing of sunken boxes and making good the distrubed surfaces to match the existing surfaces.
All as per Sl item No 2 here in before but wiring with FRLS , Multistranded copper conductor cables in PVC Casing and capping Note : Rates are deemed to be including providing PVC accessories i.e Tee,elbow,socket etc.
M& L in replacement of Point wiring for one 2 way light point/ fan point/ bell point etc controlled by one switch with copper conductor cable FRLS type multistrand of size 1.5 Sqmm(red or yellow or blue colour) PVC insulated and unsheathed with 1.5 Sqmm PVC insulated copper conductor cable as earth wire (green colour), in and including non metalic rigid PVC Conduit of appropriate size not less than 20mm dia,and with sunk cast iron for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified.
M& L in replacement of Point wiring for one socket outlet 5 Amp 3/5 pin for independent board etc controlled by one switch with copper conductor cable FRLS type multistrand of size 1.5 Sqmm(red or yellow or blue colour) PVC insulated and unsheathed with 1.5 Sqmm PVC insulated copper conductor cable as earth wire (green colour), in and including non metalic rigid PVC Conduit of appropriate size not less than 20mm dia,and with sunk cast iron for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified.
All as per Sl item No 5 here in before but for one 3 pin 5 amps socket outlet independent board in PVC casing & caping all as specified and directed. Note: Rates are deemed to be including providing PVC accessories i.e Tee,elbow,socket etc.
All as per Sl item No 5 here in before but for one 3 pin 5 amps socket outlet on the same board with other switch.
All as per Sl item No 5 here in before but for one 3 pin 5 amps socket outlet on the same board in PVC casing & caping all as specified and directed. Note: Rates are deemed to be including providing PVC accessories i.e Tee,elbow,socket etc.
All as per Srl item No. 5 above but for one 15 Amp independant socket outlet point using 4.0 Sqmm FRLS PVC insulated unsheathed multi-strand copper conductor cable drawn in including non metalic rigid PVC concealed conduit (ISI marked) not less than 20mm dia,medium duty including sunken steel boxex of suitable size with 3mm thick plastic laminated bakelite sheet incl FRLS PVC insulated unsheathed multistranded copper conductor cable of size 4.0 Sqmm (green colour) earth wire connecting to earth dolly .
All as per Sl item No 9 here in before but for 15 Amp socket outlet in in PVC casing & caping all as specified and directed. Note: Rates are deemed to be including providing PVC accessories i.e Tee,elbow,socket etc.casing/caping
All as per Srl item No. 9 above but for metal plug top AC & Geyser point using 4.0 Sqmm FRLS PVC insulated unsheathed multi-strand copper conductor cable drawn in including non metalic rigid PVC concealed conduit (ISI marked) not less than 20mm dia, incl FRLS PVC insulated unsheathed multistranded copper conductor cable of size 4.0 Sqmm (green colour) earth wire connecting to earth dolly .
M & L for Switch piano flush button single pole one way 6 Amps 240 volts with polycarbonate body complete all as specified and directed.
M & L in replacement for Switch piano flush button single pole one way 6 Amps 240 volts with polycarbonate body complete all as specified and directed.
M&L for two way switch piano, flush button, single pole two way 6 amps 240 Volt with polycarbonate body complete all as specified and directed.
M&L in replacement for two way switch piano, flush button, single pole two way 6 amps 240 Volt with polycarbonate body complete all as specified and directed.
M&L for Bell push switch piano flush button single pole one way 5 Amps 240 volts with polycarbonate body complete all as specified and directed.
M&L in replacement for Bell push switch piano flush button single pole one way 5 Amps 240 volts with polycarbonate body complete all as specified and directed.
S&F for multi socket outlet for 2 &3 pin, 6A, flush type complete all as specified and directed.
S&F in replacement for multi socket outlet for 2 &3 pin, 6A, flush type complete all as specified and directed.
S&F for socket outlet 2 in 1, 3 pin, 6 and 16 Amps , flush type, single pole, one way, 230Volts complete all as specified and directed.
S&F in replacement of socket outlet 2 in 1, 3 pin, 6 and 16 Amps , flush type, single pole, one way, 230Volts complete all as specified and directed.
S&F for switch piano, flush type, single pole, one way, 16 Amps 230Volts complete all as specified and directed.
S&F in replacement of switch piano, flush type, single pole, one way, 16 Amps 230Volts complete all as specified and directed.
S&F for stepped type electronic mini fan regulator 100 watt rotary step all as specified and directed.
S&Fin replacement for stepped type electronic mini fan regulator 100 watt rotary step all as specified and directed.
S&F for stepped type electronic deluxe fan regulator100 Watt rotary step all as specified and directed.
S&F in replacement for stepped type electronic deluxe fan regulator100 Watt rotary step all as specified and directed.
M&L for modular point wiring for one light/fan/bell point controlled by one switch complete with 1.5 Sqmm multistranded FRLS PVC insulated unsheathed ,FRLS , multistranded copper conductor cable 1100 volts grade in and including non metallic rigid PVC medium duty concealed conduit with wall thickness not less than 20 mm dia including conduit accessories like bends, tees junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sqmm single core FRLS PVC green insulated unsheathed multi stranded copper conductor 1100 Volts grade as earth continuity wire connected to earth dolly including inner and outer frame plate matching with surrouding with modular sunken steel boxes zinc oxide plated of suitable size including modular sheets of suitable module and back plates etc. complete all as specified and directed by Engineer-in-Charge.
Description all as per srl item No. 28.00 here-in-before but for 5 pin 5 Amps socket outlet on independent board controlled by one switch 5 Amps one way, complete all as specified and directed.
Description all as per srl item No. 28.00 here-in-before but for 5 pin 5 Amps socket outlet on same board controlled by one switch 5 Amps one way, complete all as specified and directed.
Description all as per srl item No.28.00 here-in-before but for 15 Amps socket outlets point using 4.00 Sqmm FRLS PVC insulated multistranded copper conductor cable including 4.0 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable as earth wire complete all as specified and directed.
M&L for one Module switch 1 way 10 Amps 240 volts all as specified and directed.
M&L in replacement for one Module switch 1 way 10 Amps 240 volts all as specified and directed.
M&L for one Module switch 1 way 16 Amps 240 volts all as specified and directed.
M&L in replacement for one Module switch 1 way 16 Amps 240 volts all as specified and directed.
M&L for Moduler bell push 6A, 240 volts 1 Module all as specified and directed.
M&L in replacement for Moduler bell push 6A, 240 volts 1 Module all as specified and directed.
M&L for Modular socket 6A, 240 volts 2/3 pin 2 Module all as specified and directed.
M&L in replacement for Modular socket 6A, 240 volts 2/3 pin 2 Module all as specified and directed.
M&L for Modular socket 6A/16A , 240 volts 2/3 pin 2 Module all as specified and directed.
M&L in replacement for Modular socket 6A/16A , 240 volts 2/3 pin 2 Module all as specified and directed.
M&L for Modular Fan step regulator 100W , 240 volts 2 Module all as specified and directed.
M&L in replacement for Modular Fan step regulator 100W , 240 volts 2 Module all as specified and directed.
M&L in replacement for Modular Fan step regulator 100W , 240 volts 1 Module all as specified and directed.
M&L in replacement for ceiling rose surface bakelite 2 to 3 terminals with polycarbonate body.
M&L for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings.
M&Lin replacement for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings.
M&L in replacement of LED bulb 12 watt 230 Volt all as specified and directed.
Supply & fix for wall mounted 1x20 watt LED 6500K tube light fittings (4 feet long),Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient with all accessories and making connection using 2 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed.
Supply & fix in replacement of wall mounted 1x20 watt LED 6500K tube light fittings (4 feet long),Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient with all accessories and making connection using 2 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed.
Supply and fixing for LED light fittings mirror type with high out put diffuser 2 feet .10 watt 220 volt AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing in replacement of LED light fittings mirror type with high out put diffuser 2 feet .10 watt 220 volt AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED Bulk Head luminaries 10W complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ.
S&F in replacement of LED Bulk Head luminaries 10W complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ.
M&L for Bell, Ding Dong AC. 230 volts, single pole all as specified.
M&L for in replacement of Bell, Ding Dong AC. 230 volts, single pole all as specified.
M&L in replacement of sheet metal enclousers single pole and neutral 240 volt , 20 Amps with two pin and earth plug and socket plug top complete with single pole MCBs all as specified and directed.
Supply and fix in replacement of old unserviciable Sheet metal enclousre for DBs single door single pole and neutral with 200 amps rated bus bar of 2- way, 240 volts complete all as spd and directed.
Supply and fix in replacement of old unserviciable Sheet metal enclousre for DBs double door single pole and neutral with 200 amps rated bus bar of 4- way, 240 volts complete all as spd and directed.
Supply and fix in replacement of old unserviciable Sheet metal enclousre for DBs double door single pole and neutral with 200 amps rated bus bar of 8- way, 240 volts complete all as spd and directed.
Supply and fixing in repair MCB single pole and nuetral 40 Amps, 240 volts , B-series complete all as specified and directed.
Supply and fixing in repair MCB single pole 6 to 32 Amps, 240 volts , B-series all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 600mmx600mm thickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electric plate No 3 connected to earth test point/MCB DBs all as specified and indicated complete with funnel, charcoal, dust, salt etc and GI protection pipe, medium grade 15mm bore and GI watering pipe 20mm bore light grade, 40mm thick precast RCC M-15 (nomial mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover, PCC M-15 (Nominal mix) pit, excavation and earth work in any type of soil and connected, complete all as specified & directed. Note:- 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in the unit rate quoted by the contractor. 2. Soil should be free fromstone, boulders, aggregate, gravels etc
M & L for sub main wiring with 6.0 sqmm copper conductor cable multistrand, FRLS PVC sheathed two run (as phase and neutral) and one run 6.0 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in drawn in existing surface /recessed steel/ PVC conduit complete all as specified and directed by Engr-in-charge.,
S & F in replacement (including taking down old fitting) LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in Repair octane LED panel of 15 W 6500K round slim,compact,auminum die cast edge lit panel.Recessed mounted round fixture with opal diffuser and separate electronic driver and low profile downlights are engineered to deliver superior light output and uniformity utilising the latest edge-lit LED technology.An ideal solution where ceiling voids are limited but high lumen output Cat No- LHEBADP7IZ1W015 of Havells or equivalent in Bajaj/Crompton Greaves/Phillips
S&F in Repair octane LED panel of 15 W 6500K square slim,compact,auminum die cast edge lit panel.Recessed mounted square fixture with opal diffuser and separate electronic driver and low profile downlights are engineered to deliver superior light output and uniformity utilising the latest edge-lit LED technology.An ideal solution where ceiling voids are limited but high lumen output Cat No- LHEBAEP7IZ1W015 of Havells or equivalent in Bajaj/Crompton Greaves/Phillips
S&F in replacement of old u/s service cable size 10 sqmm twin core multistranded fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire of 4mm dia or tape and overall PVC sheathed complete all as specified and directed.
S&F in replacement of old u/s service cable size 16 sqmm twin core multistranded fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire of 4mm dia or tape and overall PVC sheathed complete all as specified and directed.
S&F "as in repair prewired" VTPN Distribution board with provision for MCCB as incommer 100 A 04 pole IP 54 ,04way(for incomming MCCB & outgoing MCBs), with copper busbar for each phase, with Neutral bar, Earth bar and cable ties for cable managemet, fully insulated busbar & shrouded Neutral bars, with 100 Amps MCCB, 25 KA, 4 pole, as incomer and SP MCB's of cap 6-32amps as outgoing complete all as specified and as directed. Note: Rate of MCCBs and MCB,cutting,chasing,grouting in wall are included in above rate.
Repair & maint of water cooler 60/120 Ltr capacity by disconnecting and taking down old u/s burnt compressor unit and S&F with new company manufactures sealed unit compressor complete with initial filling of gas confirming to ISI mark suitable to existing water cooler including testing, complete unit for required performance and smooth functioning for 24 Hrs complete with checking internal wiring cleaning, flushing to condensing coil, cleaning to tank etc complete all as specified and directed. Notes (For Srl item No. 1 ) :- (i) Purchase Voucher, test certificate, warranty to be furnished by the contractor to Engineer-in-Charge. (ii) All engineering works shall be carried out at site/MES store yard. (Make of compressor unit :- Copeland / Usha / Sidwal / Voltas / Blue star)
Material and labour for repairing to bottom base/stand of water cooler of any make/type/capacity including welding of MS/GI sheet 16 SWG of suitable size to fill up rusted patches, grinding and applying base material for smooth surface and applying 2 coat of synthetic enamel spray paint of existing colour over one coat of primer etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement of old UNSV starting relay with overload protector for water cooler of any cap, complete all as specified and directed. Make :- As per existing sample or Model No. 85002/85003 of Kirloskar / Sri Ram / Hi Tech)
S&F in replacement of running capacitor 10/15/20 mfd for water cooler complete all as specified and directed. Make :- Havells / Asian / Texla / Bajaj / EPCOS
S&F in replacement of old UNSV push cock / bib cock tap, copper alloy chromium plated of 15mm bore, matching to the existing one, complete all as specified and directed.
S&F in replacement of old UNSV fan blade for water cooler fan motor of type and size matching to existing sample and size complete all as specified and directed.
S&F in replacement of old UNSV fan motor of cap 1/10 HP, single phase, 230 volt suitable to existing type water cooler complete all as specified and directed. Make :- Universel / AUE / Airmaster
S&F in replacement of old UNSV thermostat as per existing sample/make for water cooler of any capacity, complete all as specified and directed. Make :- Renutral / Indfos / ANNAPURNA
S&F in replacement of old UNSV PVC waste water pipe with clamp, suitable to existing size for water cooler of any cap, complete all as specified and directed.
S&F chromium plated water tray basin for water cooler of any cap matching to the existing including taking down old one and removal from site, complete all as specified and directed.
M&L for preparation of old painted surfaces of water cooler including repairing the denting surface by applying putty and removing old paint cleaning and applying two coats by spray painting with approved colour,,writting the SM /Ser No / unit name and date of repair of machine complete all as specified and directed. Note :- Colour code shall be approved by Engineer-in-Charge.
S&F in replacement 15mm dia PTMT float ball valve complete for water cooler, complete all as specified and directed.
S&F in replacement of starting capacitor 100/120 mfd complete all as specified and directed. Make :- Havells / Asian / Texla / Bajaj / EPCOS
Replacement of old unsericeable / damage condensing coil with new condensing coil matching to existing one for water cooler of cap any type , complete all as specified and directed by Engineer-in-charge.
S&F in replacement of 5 Amp plug top, 3 pin complete all as specified and directed. Make :- Anchor / GM / Havells
S&F in replacement of old unserviceable PVC insulated, sheathed, stranded copper conductor cable of size 0.75 Sqmm, 3 core, 1100 volt grade, incl connection and testing, complete all as specified and directed. Make :- Finolex / Polycab / Havells
Repair and Maint of window/split AC 1.5/2Ton capacity by disconnecting and taking down old unserviceable burnt compressor unit and S&F with new company manufactures sealed unit compressor complete with initial filling of gas confirming to ISI suitable to existing AC including testing complete unit for required performance and smooth functioning for 24 Hrs, complete with checking internal wiring , cleaning , flushing to condensing coil , cleaning to tank etc complete all as specified and directed. Notes for item 17:- (i) Purchase Voucher, test certificate, warranty to be furnished by the contractor to Engineer-in-Charge. (ii) All engineering works shall be carried out at site/MES store yard. Make of compressor :- Copeland / Kirloskar / Whirlpool / Voltas / Blue star / LG
S&F in replacement of starting capacitor 36 or 50 + 6 mfd as required at site complete all as specified and directed. Make :- Havelles / TEXLA / AUE / ASIAN / USHA / EPCOS
S&F in replacement of starting relay with overload protector suitable for split/ window AC any cap complete as per existing sample complete all as specified and directed. Make Anapurna / TEXLA / AUE / ASIAN / USHA.
S&F in replacement of anti-bacteria air filter as per sample for split/window type AC of any capacity complete all as specified and directed.
S&F in replacement of blower for split/window type AC complete as per existing sample complete all as specified and directed.
S&F in replacement of 15 Amp plug top, 3 pin complete all as specified and directed. Make :- Anchor / GM / Havells
S&F in replacement of old unserviceable PVC insulated, sheathed, stranded copper conductor cable of size 2.5 Sqmm, 3 core, 1100 volt grade, incl connection and testing, complete all as specified and directed. Make :- Finolex / Polycab / Havells
S&F in replacement of plug top (male)20 Amps for sheet metal(industrial) enclosure complete all as specified and directed.
S&F in replacement of old unserviceable swing motor for 1.5/2.00 Ton split AC/ window type AC as per sample and existing make, complete all as specified and directed.
S&F in replacement of old unsv condenser coil/ evaporator coil (cooling coil) suitable for split AC/ window AC 1.5/ 2.0 Ton including welding/ soldering at site, all as per sample complete all as specified and directed.
S&F in replacement of old unsv PCB circuit with remote,display, board, display sticker, Transformer, suitable for window / split type AC of any type and any capacity including all electrical connections at site, complete all as specified and directed. Make of OEM :- Samsung / LG / VOLTAS / Haier
S&F in replacement old unsv PVC front grill as per existing sample for window type AC 1.5/ 2.0 Ton complete all as specified and directed.
Dismantling/ opening the split AC/ window type AC 1.0 / 1.5 / 2.0 ton capacity from the site and supply and fixing reversible cycle valves in existing AC to function for cooling or heating system including electrical connection, refixing the AC at it's position and testing, complete all as specified and directed.
S&F in replacement of old unsv blower motor (as per sample) double shaft having for 1.5/ 2 Ton window AC, complete all as specified and directed.
S&F in replacement of old unsv indoor unit blower motor for split AC 1.5/ 2.0 Ton as per sample complete all as specified and directed..
S&F in replacement of old unsv discharge service valve as per sample for Split AC of any type complete all as specified and directed.
S&F in replacement old unsv condensing coil fan motor for Split AC 1.5/ 2 Ton as per sample complete all as specified and directed.
S&F in replacement of unsv copper pipe ½" dia as per sample complete all as specified and directed.
S&F in replacement of unsv copper pipe ¼" dia as per sample complete all as specified and directed.
S & F in replacement of new nitrile rubber insulation tube for split air conditioner copper pipes of any size upto 1/2" dia complete all as specified and directed. (Make : Glaxy/Superlon/KAIFLEX/PARAMOUNT/ARMAFLEX/ VIDOFLEX)
M&L for fixing M-Seal water proof in ACs window/split type, complete all as specified and directed.
M&L for replacement of liquid line valve of suitable size for Split AC, complete all as specified and directed.
Supply in replacement of remote control suitable to existing window/split type ACs (As per sample & existing make) complete all as specified and directed.
M&L for servicing at site of window/ split AC of any type, any size by opening , cleaning, re-fixing the filters, cleaning & washing of condenser and evaporator coil with brushes, chemical etc. including taking down and refixing in position of AC, if reqd for satisfactory functioning of AC complete all as specified and directed. Note : Gas and spaire parts are measure for separately.
Repair and maint of deep freezer of 120 to 500 ltr capacity by disconnecting and taking down old unsv burn compressor unit and Supply and fixing new company manufactures sealed unit compressor complete with initialfilling of Gas confirming to ISI suitable to existing deep freezer including testing ,complete unit for required perfermance and smooth functioning for 24 Hrs complete with checking internal wiring , cleaning , flushing to condensing coil, cleaning to tank etc. complete all as specified and directed . Note for item Sr No 41 :- (i) Purchase Voucher, test certificate, warranty to be furnished by the contractor to Engineer-in-Charge. (ii) All Engineering works shall be carried out at site/ MES store yard and in presence of Engineer-in-Charge. (Make of compressor : Copeland / Voltas / LG / Usha / Godrej
S&F in replacement of old unsv starting relay as per sample for deep freezers of any capacity, complete all as specified and directed.
S&F in replacement of old unsv thermostat switch as per sample for deep freezer of any capacity, complete all as specified and directed. Make :- Renutrol / Indofoss / ANNAPURNA
S&F in replacement of old unsv blower motor as per sample for deep freezer complete all as specified and directed.
Supply and fixing in replacement of Door Lock with door gasket for refrigerator 165 to 310 ltrs complete all as specified and directed.
M & L for replacement of deep freezer outer body 320 ltr capacity including all accessories as per existing make approved by Engr-in- charge.
Repair and maint of refrigirator 210 to 320 Ltrs capacity by disconnecting and taking down old unsv burnt compressor unit and S&F with new company manufactures sealed unit compressor complete with initial filling of gas confirming to ISI suitable to existing refrigirator including testing complete unit for required performance and smooth functioning for 24 Hrs complete with checking internal wiring , cleaning , flushing to considering coil , cleaning to tank etc complete all as specified and directed. Notes for item Sr No 47 :- (i) Purchase Voucher, test certificate, warranty to be furnished by the contractor to Engineer-in-Charge. (ii) All engineering works shall be carried out at site/ MES store yard and in presence of Engineer-in-Charge. Make of compressor :- Whirlpool / LG / Samsung / Copeland / Godrej
S&F in replacement of old unsv cooling coil freezer/ evaporator assy as per sample for refrigerator of any capacity complete all as specified and directed.
S&F in replacement of old unsv condensing coil assy as per sample for refrigerator of any capacity, any type (single door/ double door) complete all as specified and directed.
S&F in replacement of old unsv auto defrost thermostat switch as per sample for refrigerator of any capacity. Make: ANNAPURNA or equivalent approved make.
S&F in replacement of old unsv starting PTC relay with OLP as per existing sample for Refrigerator of any cap Make:- Godrej / Whirpool / Hi-Tech / LG complete all as specified and directed.
S&F in replacement of old unsv cooling coils (fins and tube type/ pressed type) for double door refrigerator (as per sample required at site) complete all as specified and directed.
S&F in replacement of old unsv timer as per sample for double door refrigerator of any capacity complete all as specified and directed.
S&F in replacement of old unsv Bimetal thermostat assy as per sample for double door refrigerator of any capacity complete all as specified and directed.
S&F in replacement of old unsv blower motor/fan motor as per sample for double door refrigerator of any capacity complete all as specified and directed.
S&F in replacement of old unsv heater as per sample for any capacity refrigerator complete all as specified and directed.
S&F in replacement of old unsv transparent vegetable tray as per sample for any capacity refrigerator complete all as specified and directed.
S&F in replacement of old unsv wire shelf set as per sample for any capacity refrigerator complete all as specified and directed.
S&F in replacement of old unsv electronic control board (PCB) as per sample for refrigerator of capacity 210 Ltrs to 320 Ltrs including connection, complete as specified and as directed.
M&L for charging refrigerant gas R-22 in old or new compressor and make up required pressure including brazing and testing, complete all as specified and directed.
Supply and fixing in replacement of Interior light fittings with bulb for refrigirator of any size and any capcity.
M&L for charging refrigerant gas R-134a or 410a in old or new compressor to make-up required pressure including cutting piping, brazing and testing, complete all as specified and directed.
M&L for writing SM Number / MES No , Unit and date of repair on refrigerator / deep freezer and AC with paint & colour, text height complete all as specified and directed by Engr-in-Charge. Note: The writing of SM/MES No at one equipment shall be measured as one unit.
M&L for repair of voltage stabilizer of 15 KVA of any type including replacement of spare parts such as transformer, PCB, diode, condenser, preset ic , volt meter, ammeter, indicator lamp, socket outlet and any other parts as required for proper functioning of stabilizer complete along with testing and transportation charges from site to workshop, complete all as specified and directed.
Supply of CTC (commercial technical chemical) for flushing of refrigerator & deep freezer lines to remove choking all as specified and directed.(200 ML BOTTLE).
S&F copper coil capillary tube for Refrigerator/ Deep freezer as per sample size complete all as speciifed and directed.
S&F in replacement of old Unsv copper Pencil filter drier with new drier filter having desiccant complete including necessary cutting, removing old drier filter with reqd brading work for Refrigerator, Deep Freezer any cap complete all as specified and directed.
M & L for replacement of Gas charging pin valve for any type of AC as per sample all as specified and directed.
Note :- An amount of Rs. 34,280.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/s Nasir Rasool Dar (BID ID -3134951)
M/S A Q ENTERPRISES (BID ID -3136214)
M/s FAYAZ AHMAD BHAT C/O ZAHOOR AHMAD DAR (BID ID -3136806)
M/S SHIMAR STAR GLACIER (BID ID -3136366)
M/S N A Enterprises (BID ID -3136416)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .