Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC | L1 | Accepted-AOC lowest and reasonable | |
| 2 | L2₹43.7 L+₹9.2 L (26.7%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L2 | Rejected-Finance Lowest and reasonable | |
| 3 | L3₹49.0 L+₹14.5 L (42.2%)Rejected-Finance | L3 | Rejected-Finance Not lowest |
Tender Value
Refer Docs
EMD Value
₹93,626
Closing Date
20 Jul 2022, 6:00 pmClosed
Col Vikas Kesarwani
CWE AF Lohegaon
SPECIAL REPAIR TO BLDG NO P 66 P 134 AT AF STN MADH ISLAND UNDER GE AF THANE
2022_MES_519499_3
82620/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF Thane
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF Thane
₹93,626
Yes
23 Aug 2022
21 Jun 2022
27 Jul 2022
21 Jun 2022
20 Jul 2022
27 Jun 2022
Amount
Taking down cement or cement lime plaster on brick or stone walls, etc including racking out joints hacking for key, scrubbing down with water etc complete all as specified and as directed by Engr-in- Charge.
Demolition of brick work / stone built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed by Engr-in- Charge.
M&L for brick work with sub-class 'B' bricks, straight or curved on plain to any radius in half brick thick walls, 115mm thick built in CM 1:4 complete all as specified and directed by Engr-in- Charge.
M&L for 10mm thick rendering in CM 1:6 finished with neeru finish on fair faces of brick or concrete surface complete all as specified and directed by Engr-in- Charge.
M&L for rendering 20mm thick in two layers on external surfaces first layer 15mm thick in CM 1:6 on fair faces of brick/PCC block or concrete surfaces and second layer ( setting coat / finishing) 5mm thick in CM 1:4 with approved water proofing liquid compound finished even and smooth without using extra cement complete all as specified and directed by Engr-in- Charge. (Note:- WPC shall be measured and paid seperately)
M&L for 5 mm thick rendering in cement mortar 1:3 on fair faces of brick or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engr-in- Charge.
Supplied only water proofing liquid /compound complete all as specified and directed by Engineer in charge.
M&L for plain cement concrete (PCC) padding in cement concrete (1:2:4) type BO (using 12.5mm graded aggregate) finished even and smooth with out using extra cement all as specified directed by Engr-in-Charge
Material & labour for applying two coats of premium exterior acrylic emulsion paint having VOC less than 50 gm/ltr and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silcon additives @ 1.43 litre / 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre /10 Sqm over new surface complete all as specified and directed by Engr-in- CHarge.
M&L for applying two coats of oil bound distemper over a coat of primer,over 1mm thick wall care putty on walls including preparation of new or previously untreated surfaces complete all specified and directed by Engr-in- Charge.
M&L for applying three coats of white wash including preparation of newly plastered ceiling surfaces complete all as specified and directed by Engr-in- Charge.
M&L for water proofing treatment with APP based polymeric membrane over 15mm thick plaster on roof with the following courses of treatment :- (a) Complete removal of existing treatment, cleaning & washing the concrete /tiles surface by using wire brush including junction of parapet etc. (b) M&L 15mm thick cement plaster in CM 1:4 using water proofing liquid as per manufacturer instructions over neat cement slurry @ 3kg/Sqm on roof surface. Note: Water proofing liquid /compound will be measured & paid separately. (c) Applying bituminous primer (IS 3384) @ 0.160 Kg per sqm of the surface area including cleaning the surfaces complete all as specified. (d) M&L for APP based polymeric membrane minimum weighing 3 kg/Sqm and minimum 3mm thick reinforcement with polyster non woven fabric (wt of reinforcement not less than 150gms/sqm) laid in primed surfaced application including preparation and applying two coats of Heat resisting Aluminium paint over APP membrane complete all as specified and directed.
Removal of existing concrete including loose/weak concrete from the concrete structure ie. beams/columns/deckslab etc upto beyond corroded steel reinforcements to a depth of minimum 10mm behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting and removal of debris. Concrete around corroded reinforcement shall be removed properly. The edges of the repair locations of concrete should be saw cut to depth of at least 10mm to avoid featheredging and to provide a square edge including steel frame height of single scaffolding Complete all as specified and directed by Engr-in- Charge
Preparation of surface and removal of rust from steel bars, loosely bonded concrete of the RCC deckslab, beam / girder shall be chipped out using the mechanical cutter exposing the reinforcement bars and applying Rust Remover using small brush and allow to react it for 16-24 hrs. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth including necessary scaffolding complete all as per manufacturer instructions and directed by Engr- in- Charge.
M&L for applying two coats of Anti-Corrosive Primer two component (epoxy anticorrosive zinc rich coating) on reinforcement steel surfaces uniformely. Coating shall be applied by the brush to the exposed and cleaned rebars with an interval of 45 minutes to 1 hour @40 microns DFT/ coat and allowed to completely dry for 24 hours including necessary scaffolding complete all as per manufacturer instructions and directed by Engr- in-Charge.
M&L preparation of concrete surfaces by removing loose concrete dust, dirt etc. Cleaning the surface properly and applying one liberal coat of epoxy bonding agent ( two component agent) by brush application to parent concrete including necessary scaffolding complete all as per manufacturer instruction and directed by Engr-in- Charge.
M&L 50mm thick ( average thickness) polymer modified single component alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar on conrete structure. Applying the mortar arround the reinforcement and finishing to bring it in line with existing concrete surface including necessary scaffolding complete all as per manufacturer instructions and directed by the Engr-in- Charge. Cured mortar should exhibit compressive strength of 20 MPa after 1 day and atleast 45 MPa after 28 days, tensile strength atleast 2.5 MPa after 28 days and flexural strength atleast 7 MPa after 28 days.
M&L for holes of dia 16mm and depth 100mm drilled @ a spacing of 1mtr c/c both ways on the existing structure. The loose cementitious particles are removed using a air blower to clean the holes. Shear keys of dia 10mm cut from HYSD rebars are anchored into these holes of depth 75mm and bent out to an equal length of 75mm using resin anchor grout complete all as per manufacturer instructions and directed by Engineer in Charge
M&L for injection / pressure grouting in the cracks in the parent concrete by fixing PVC/Aluminium nipples at 150mm to 200 mm distance or specified distances as per design and detailed specifications. Pressure grouting using low viscous epoxy grout. Moisture intensitive epoxy resign injection material supplied in 1.5 ltr pack which can grout gaps ranging from 0.25mm to 9mm having mix density 1060 kg/cum, compressive strength 60N/mm2 , tensile strength 20 N/mm2, Flexural strength 45 N/mm2 . Pressure grouting shall be carried out after surface preparations including fixing nipples and filling cracks with epoxy mortar etc including necessary steel double scaffolding and form work as well as the protection of existing structure during rehabilitation complete all as specified and directed by Engr - in- Charge.
M&L for 25mm thick sand faced rendering on external surfaces in CM 1:4 mixed with approved water proofing admixture based on lignosulphates having chloride content as per IS 2645- 2003 mixed as per manufacturer instructions etc finished even and smooth without using extra cement including necessary steel double scaffolding and form work as well as the protection of existing structure during rehabilitation complete all as specified and directed by Engr - in- Charge.
M&L for micro concrete to existing concrete structure including proper tight leak proof shuttering SPL polimer modified cementitious ,low pemeable 'free flow ' non shrink ' self compacting micro concrete shall be grade M70 as per recommended w/c ratio and pouring as per the required thickness including double scaffolding and form work complete all as per manufacturer instructions and directed by Engr-in- Charge. Quoted rates to include scffolding costs.
Dismantling of structural steel work of any description complete all as specified and directed by Engineer in charge.
M & L for MS TMT bars 10mm dia and over as in reinforcement, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed by Engineer in charge.
Dismantling floor, hearth or wall tiles laid, bedded, pointed in any mortar of any description or thickness in floors, aprons etc. complete all as specified and directed by Engineer in charge.
M&L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tilest exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm screed bed or bedding layer for floor finishes in CM 1:4 complete all as specified and directed by Engr-in- Charge.
M&L for joint free coloured Glazed ceramic tiles in vertical surface 350x 250x 7 mm or 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match in colour cement to match complete all as specified and as directed by Engr-in- Charge.
M&L for Non - skid Ceramic Coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm screed bed or bedding layer for floor finishes in CM 1:4 complete all as specified and as directed by Engr-in-Charge.
Taking up or down carefully 20 mm bore steel tubing and connections complete all as specified and directed by Engineer in charge.
Taking up or down carefully 15 mm bore steel tubing and connections complete all as specified and directed by Engineer in charge.
S&F 20mm bore galvanised Steel Water tubing, ISI marked medium grade with necessary fittings such as bends, elbows, tees, unions, short pieces, caps & plugs etc fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer in charge.
-Ditto- all as per item No.29 above, but fixing only old GI tubing complete all as specified and as directed by Engineer in charge..
S&F 15mm bore galvanised Steel Water tubing, ISI marked medium grade with necessary fittings such as bends, elbows, tees, unions, short pieces, caps & plugs etc fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer in charge.
-Ditto- all as per item No.31 above, but fixing only old GI tubing complete all as specified and as directed by Engineer in charge..
S&F for 15 mm bore stop valves chromium plated fancy type weight not less than 575 gm screwed down high pressure with crutch or batterfly handle screwed both ends for iron pipes or for union fixed in repair complete all as specified and as directed by Engr-in- Charge..
S&F for bib tap 15 mm bore of fancy chromioum plated with long shank & cup , weight not less than 575 gmscrewed down high pressure with crutch or butterfly, screwed both ends for iron pipe or for brass ferrule fixed in repair complete all as specified and as directed by Engr-in- Charge.
S&F PVC connection 15mm dia sizes with PTMT nuts of length 600 mm complete all as specified and directed by Engineer in charge.
S&F PVC valve less syphonic action type, flushing cistern 10 ltrs capacity,low level white with inlet, ball valve float and handle including brackets including 32mm dia PVC flush pipe for low level cistern including all joints fixed in repair complete all as specified and directed by Engr-in- Charge.
S&F Grating down 150mm square of PTMT ( minimum weight 150 gms) complete all as specified and directed by Engr - in- Charge.
S&F in repairs aluminium powder coated decorative curtain rod 20 to 25 mm dia complete all as specified and directed by Engr - in- Charge.
S&F in decorative PVC end cap suitable for aluminium powder coated decorative curtain rod 20 to 25 mm dia complete all as specified and directed by Engr - in- Charge.
S&F in repairs aluminium powder coated brackets suitable for decorative curtain rod 20 to 25 mm dia complete all as specified and directed by Engr - in- Charge.
S&F in repairs PVC bathroom cabinet of size 460x600x5mm thick made out of 4mm thick PVC acrylic sheet approved colour and as per trade pattern with mirror of 5mm thick glass openable type etc complete all as specified and directed by Engr - in- Charge.
S&F vitreous china wash down water closet pan, 'Pedestal' white, including fixing bolts, PVC seat cover white with flat bottom, mild steel chromium plated or aluminium anodised hinge devices, inlet, outlet pipe connections etc. complete all as specified and as directed.
S&F in repair 15mm ball brass valves high pressure weight not less than 280 gm with polythene flot and flynut completescred for iron pipes or brass ferrule and fix complete all as specified and directed by Engineer in charge.
S&F rotational moulded polyethylene water storage tank tripple layer cylindrical vertical with closed top 1000 ltrs capacity hoisted and fixed in position connecting to inlet and outlet pipe connections with and including 20mm dia GI wash out with plug fixed in repairs complete all as specified and directed by Engineer in charge.
S&F health faucet with 15 mm bore dia chromium plated angle cock with stud complete all as specified and as directed by Engr-in- Charge.
S&F in repairs for 15 mm bore CP angle stop valves weight not less than 575 gmof high pressure screwed for iron pipe and fixed complete all as specified and directed by Engineer in charge.as specified.
S & F rolled mild steel as in tubular trusses (framed) purlins, angle, beam, tee, channel including distance piece, cleats etc , grade Fe - 410W (gde E 250 quality B) with and including necessary cutting, bending, drilling holes, welding rebates etc complete all as specified and directed by Engineer in charge.
S&F wind ties for roof including securing bolts and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer in charge.
S&F for Mild steel Plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410W(Gde-E-250) complete all as specified and as directed by Engr-in- Charge.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed by Engineer in charge.
S&F Pre-painted galvalume aluminium zinc coated GI based corrugated rib pattern steel sheeting (PPGL) 0.50mm thick ( base metal thickness not less than 0.45mm) of any colour having tensile strength 550 Mpa as in roof covering/cladding to wall , fixed with self tapping screws etc complete all as specified and directed by Engineer in charge.
M&L for Preparation of new steel surface of any description over 10 Cm in width or girth, not otherwise described applying two coats of synthetic enamel paints over a coat of red oxide zinc primer complete all as specified and directed by Engineer in charge.
S&F stainless steel Gde 304, polished pipe, square or round in framed work such as stair case railing etc with necessary fitting & fixtures as per manufacturer instructions complete all as specified and as directed by Engr-in- Charge.
Taking down Shutters of any description exc 1 sq. m and not exc 2 sq. m each complete all as specified and as directed by Engr-in- Charge.
S&F 150 mm extruded aluminum alloy handles, cast type, anodized complete all as specified and directed by Engineer in charge.
S&F 100 mm extruded aluminum alloy handles, cast type, anodized complete all as specified and directed by Engineer in charge.
S&F mild steel 100 mm long butt hinges, medium weight cold rolled complete all as specified and directed by Engineer in charge.
S&F in repairs 300 mm long aluminium alloy, anodised , sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast - aluminium alloy and fixed complete all as specified and directed by Engineer in charge.
S&F 150 mm long aluminum anodised barrel tower bolts of extruded section of size complete all as specified and directed by Engineer in charge.
S&F 100 mm long aluminum anodised barrel tower bolts of extruded section of size complete all as specified and directed by Engineer in charge.
S&F in repairs for Galvanised mild steel wire cloth of 0.56 mm nominal dia of wire & and average width of aperture 1.18 mm fixed with Aluminium beeds for bird proofing of ventillators complete all as specified and directed by Engineer in charge.
Taking down Chowkhats or frames without taking of shutters exc 1.5 sq. m but not exc 4 sq. m each complete all as specified and as directed by Engr-in- Charge.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing complete all as specified and directed by Engr-in- Charge.
S&F for 30mm thick IInd class hard wood glazed and skelton shutters divided into squares with plain chamfered or rounded miltred and related sash bars number to received glass gauze etc edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I section 8 clause 8.20 supplied and fitted to chowkats complete complete all as specified and directed by Engr-in-charge.
S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of ms tubes for top &bottem rails, ms frame shall be covered with heat moulded plain colour PVC 'C' channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour pvc sheetfor top rail ,lock rail, &bottem rail, on either side & as gap insert for top rail , panneling of plain colour pvc sheet to be fitted in the ms frame welded /sealed to the stiles & rails with suitable pvc sheet beading, & jointed together with solvent cement suppling & fixing in the frame at site as specified in SSR Part I clause 8.34 section 8 complete all as specified and directed by Engr-in-Charge.
S&F LPDE waste pipes of 32mm bore pressure rating 6 Kgf/Sqcm for wash hand basin, all as specified complete all as specified and directed by Engineer in charge.
S&F grating 150mm dia of Chromium plated for wash basin fixed in repairs complete all as specified and directed by Engineer in charge.as specified.
S & F in repair CP Brass shower rose with or without swivel joints, 100mm x 100 mm size , including fixing to steel pipe or union 15mm bore complete all as specified and as directed by Engr-in- Charge.
S & F in repair CP Brass shower arm 195mm long with bend of 45 degree with flange of PTMT of any colour minimum weight 40 gms including fixing to steel pipe or union 15mm bore complete all as specified and as directed by Engr-in- Charge.
S&F brass Chromium plated towel rod 600 mm long fixed with and including chromium plated brass screws complete all as specified and directed by Engineer in charge.
S&F brass Chromium plated towel ring of PTMT fixed with and including chromium plated brass screws complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) pipes 110mm dia in any length with rubber ring joints fixed to walls/trenches/floors etc complete all as specified and directed by Engineer in charge.
S&F in repair stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays , including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) bend 110mm dia with access door bends complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) "S" traps in bore 110 mm dia complete all as specified and directed by Engineer in charge.
S & F in repair PVC (SWR) WC connector bent type in bore 110 mm dia complete all as specified and directed by Engineer in charge.
M&L for repair 75mm PVC (SWR) floor trap with grating including jointing to waste pipe fixed in cement concrte type B1- 1:2:4 complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) gully trap 110 mm dia setting and jointing with solvent cement concrete and providing connection upto 1st manhole with PVC pipe complete all as specified and directed by Engineer in charge.
S & F in repair PVC (SWR) nahani trap with grating including jointing to waste pipe fixed in cement concrte type B1- 1:2:4 complete all as specified and directed by Engineer in charge.
S&F in repairs Powder Coated ( thickness 50 micron) aluminium frame (any colour) for partitions, doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. including sealing of window/door frames with sillicon gel to avoid rain water entry complete all as specified and as directed by Engr-in- Charge.
S&F Powder Coated (any colour) aluminium door shutters using aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges, anodised aluminum snap beading screws and floor door closer mechanism etc. complete all as specified and as directed by Engr-in- Charge.
S & F Sheet Glass, Ordinary quality 4.8 mm thick including glazing beadings/ rubber beading not exc 0.5 Sq.m in each pane complete all as specified and directed by Engr-in- Charge.
S&F in repairs 12mm thick Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination fixed with screws to timber frame work to timber/rubber beading to Aluminium framework in Partition or Wall Panelling complete all as specified and as directed by Engr-in- Charge.
S&F vitreous china wash down water closet pan ( pedestal pattern) ( as per parryware NXT wall hung with cistern) of size 670mmx365mm x 770mm including seat cover etc complete all as specified and as directed by Engr-in- Charge.
Supply and fix in repair for aluminium (extruded section) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed
Taking down carefully point wiring and removing from site such as ( light , fan socket or power) complete including fittings and fixtures, fan regulators switch boards, switches, celing roses lamp holder from existing batten PVC conduit /steel conduit wiring complete excluding light fittings and fans all as specified and making good to the disturbed surfaces to match with existing complete etc complete all as specified and as directed by Engr-in- Charge.
Taking down cearfully by unscrewing the unserviceable DB Boxes, MCB distribution boards SP & TPN with porcelain cutouts, main switches etc complete all as specified and as directed by Engr-in- Charge.
Taking down the sub main wiring of any dia / sq mm on teak wood batten / PVC conduit GI earth wire complete all as specified and as directed by Engr-in- Charge.
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets complete all as specified and as directed by Engr-in- Charge for the following:-
One light/Fan/Exhaust Fan point controlled by one way switch.
One socket outlet 5 Amps on independent board
One socket outlet 5 Amps on the same board
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping 25mm size with all fittings/fixture etc fixed wall and open recessed type Plastic switch board made of robust Synthetic material Fire Proof, Anti corrosive & shock proof ISI Marked complete for housing one 15 A Switch / sockets complete all as specified and as directed by Engr-in- Charge for the following:-
Supply and fix ceiling rose surface type bakelite/PVC three terminal 65x50mm complete all as specified and as directed by Engr-in- Charge.
S &F Modular white switch one way 6 amps 01 module complete all as specified and directed by Engr-in- Charge.
S &F Modular white switch one way 16 amps 01 module complete all as specified and directed by Engr-in- Charge.
S &F Modular white socket 06 amps 2/3 pin combined 2 module complete all as specified and directed by Engr-in- Charge.
S &F Modular white socket 6/16 amps 2/3 pin combined 2 module complete all as specified and directed by Engr-in- Charge.
S &F Modular white cover plate with frame 1 module complete all as specified and directed by Engr-in- Charge.
S &F Modular white cover plate with frame 2 module complete all as specified and directed by Engr-in- Charge.
S &F Modular white cover plate with frame 3 module complete all as specified and directed by Engr-in- Charge.
S &F Modular white cover plate with frame 4 module complete all as specified and directed by Engr-in- Charge.
S &F Modular white cover plate with frame 6 module complete all as specified and directed by Engr-in- Charge.
S &F Modular metal flush box 1/2 module complete all as specified and directed by Engr-in- Charge.
S &F Modular metal flush box 3 module complete all as specified and directed by Engr-in- Charge.
S &F Modular metal flush box 4 module complete all as specified and directed by Engr-in- Charge.
S &F Modular metal flush box 6 module complete all as specified and directed by Engr-in- Charge.
S &F Modular bell push 6 Amps 1 module complete all as specified and directed by Engr-in- Charge.
S &F Modular electric fan step type regulator, 120 W- 2 module complete all as specified and directed by Engr-in- Charge.
S &F ceiling rose surfacebacklite two to three terminal complete all as specified and directed by Engr-in- Charge.
S &F Modular Electronic fan regulator 120 Watt step type complete all as specified and directed by Engr-in- Charge.
S &F Modular Call bell AC-230 Volt single pole ding dong complete all as specified and directed by Engr-in- Charge.
S &F in replacement of Lamp holder insulated body with back plate including LED lamp 7 watt for angle holdercomplete all as specified and directed by Engr-in- Charge.
S &F Modular Switch piano flush type single pole one way 6 amps,230 V AC, single pole, one way complete all as specified and directed by Engr-in- Charge.
S &F Modular Switch piano flush type single pole one way 16 amps,230 V AC, single pole, one way complete all as specified and directed by Engr-in- Charge.
S &F socket out let multipurpose suitable for 2 pin and 3 pin 6 amp flush type complete all as specified and directed by Engr-in- Charge.
S &F socket out let multipurpose suitable for 3 pin and 3 pin 6 and 16 amp flush type complete all as specified and directed by Engr-in- Charge.
S &F in repair fan step regulator electronic type , single phase 240 volts including connection complete all as specified and directed by Engr-in- Charge.
Supply and fix in repairs sheet metal enclosure MCB DB double door SPN 8 way 240 V with neutral link and 200 A bus bar complete all as specified and as directed by Engr-in- Charge.
Supply and fix in repairs MCB DB double door SPN 12 way 240 V with neutral link and 200 A bus bar complete all as specified and as directed by Engr-in- Charge.
Supply and fix in repairs sheet metal enclosure MCB DB double door TPN 4 way 240 V with neutral link and 200 A bus bar complete all as specified and as directed by Engr-in- Charge.
Supply and fix in repairs sheet metal enclosure MCB DB TPN 4 way double door type 415 V with bus bar complete all as specified and as directed by Engr-in- Charge.
S&F in repairs sheet metal enclosure MCB TPN 63 Amps, 415Volts, complete all as specified and directed by Engr-in- Charge.
S&F in repairs sheet metal enclosure MCB SP 06 to 32 Amps 240Volts complete all as specified and directed by Engr-in- Charge.
S&F in repairs sheet metal enclosure MCB SPN 06 to 32 Amps 240Volts complete all as specified and directed by Engr-in- Charge.
Supply & fixing in repairs isolator SPN 40 A complete all as specified and directed by Engr-in-Charge
Supply & fixing in repairs isolator TPN 63 Amps 415 volts complete all as specified and directed by Engr-in-Charge
M&L for sub main wiring with two runs of single core 2.5 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 650 / 1100 V grade with colour code and one run of 1.5 Sq mm ( 22 / 0.3 mm ) single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor including PVC casing & caping all as directed. ( Note :Two runs of 2.5 Sqmm copper cable,one run of earth wire of 1.5 Sqmm copper cable shall be measured & paid as one length.) complete all as specified and as directed by Engr-in- Charge.
M&L for sub main wiring with two runs of single core 4.0 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 650 / 1100 V grade with colour code and one run of 2.5 Sq mm ( 22 / 0.3 mm ) single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor including PVC casing & caping all as directed. ( Note :Two runs of 4.0 Sqmm copper cable,one run of earth wire of 2.5 Sqmm copper cable shall be measured & paid as one length.) complete all as specified and as directed by Engr-in- Charge.
M&L for sub main wiring with two runs of single core 6.0 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4.0 Sq mm single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable for continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures complee all as specified and directed by Engineer-in-charge. (Note:- Two runs of 6.0 & one run of 4.0 sqmm copper cable including PVC casing & caping shall be mesured and paid as one length)
S&F in replacement of single pole and neutral enclouserwith a two pin and earth and metal clad plug socket complete with single pole MCB 20 AMP 240 volts complee all as specified and directed by Engineer-in-charge.
Supply and fix Energy efficient light emmitting LED light fitting aluminium body 1 x 18 watt, four feet white fittings with LED rod complete with all accessories & provn of three core cable of copper conductor of size 0.75 sqmm, making necessary electric connection from ceiling rose to fitting terminal fixing the fitting on wall including all necessary fixing accessories complete all as specified and as directed by Engr-in- Charge.
Material and labour for taking down the out door and indoor unit of split AC any capacity from the existing position and preparing of old painted surfaces of the following appliances except cooling coil cleaning and applying two coats of synthetic enamelled paint of approved colour by spray gun machanically and fixing at the same position including necessary changing of refrigerant and copper pipe, for smooth functioning of AC complete all as specified and directed by Engr-in-Charge.
M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32x6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified and as directed by Engr-in- Charge. Note:- (i) Venders are bound to get earthing result upto 5 Ohm for single earthings and 3 Ohm with the grid of two earthing.Any additional work and material required to achive the required result is included in the cost deemed to be quoted rate by Contractor. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with M&L for black cotton soil 1 cum. (iv) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (v) Taking down all items in respect of existing earthing is included in the cost deemed to be quoted by contractor.
Vishal Builders
Maaz Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .