Col Jigar Trivedi, SM
HQ CWE (AF) Gurgaon, Old Palam Road, Delhi Cantt-10
SPECIAL REPAIR TO FIRE HYDRANT SYSTEM AT TECH AREA AND TEJAS ENCLAVE AT AFSSR GURGAON UNDER GE (AF) GURGAON
2022_MES_523175_3
CWE/GGN/GT-04/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Air Force Station Gurgaon
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹87,000
Yes
21 Oct 2022
13 Sept 2022
6 Oct 2022
13 Sept 2022
4 Oct 2022
21 Sept 2022
13 Sept 2022 - 20 Sept 2022
Amount
Taking out unserviceable fire hydrant door complete and S&F New door of size 2.10m x 0.75m including chowkhat made of MS angle 40 x 40 x 6mm frame and lower half portion with MS Sheet of 3.15, thcik and half of upper portion fixed the glass of 4mm thick including painting with fire red and plaster/cement work etc as required at site complete all as specified and dircted.
Supply and fixing, erection and installation of Fire Hose Cabinet to be mounted externally near the Hydrant Post fabricated from 16 SWG MS Steel of appox size 750 mm x 600 mm x 250 mm with a canopy , door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accomodate one hydrant valve, one branch nozzle and two 7.5 mtrs hose, weather proof, Finished with P.O. fire red color including taking down old complete all as specified and directed.
Supply ,fixing,testing and commissioning of wall mounting swinging type First aid fire hose reel with drum,hanging bracket,30 mtr long and 20mm dia high pressure hose reel as per IS 444 with gun metal shut off nozzle having 5mm dia orifice.The hose reel shall be conforming to IS 884-1985. Drum shall be fixed on adjoining wall through anchor fasteners/cement concrete book or MS stand as per site requirement and the rate for fixing/hanging items in the rates quoted(for internal hydrant and one each an either side of stage) including taking down old etc complete all as specified and directed by Engr-in-charge.
Supply and fix fire hydrant landing valve type A (single head outlet) gun metal of 80 mm dia landing valve with 63 mm dia female outlet complete and 80 mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63 mm with couplings concorming to IS 903 including taking down old complete all as specified and directed.
S & F, testing and commissioning of 100mm dia, heavy duty class "C" MS pipe 6 mm thick, ISI marked as per IS : 1239 with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer includingtaking down old etc complete all as specified and directed.
S & F, testing and commissioning of 80mm dia, heavy duty class "C" MS pipe 6 mm thick ,ISI marked as per IS: 1239 with all necessary fittings & fabrication like tees , elbows ,flanges ,reducers ,gaskets ,nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer includingtaking down old etc complete all as specified and directed.
Supply and fix fire hydrant landing valve type A (single head outlet) gun metal of 80 mm dia landing valve with 63 mm dia female outlet complete and 80 mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63 mm with couplings concorming to IS 903 (for internal hydrant at 1.5 mtr height including taking down old complete all as specified and directed.
M&L for making connection from riser to to hose reel drum with GI pipe Medium grage of size 25mm dia including GI Socket, Elbow, Tee, Nipple, socket etc all materials required at site complete all as specified and directed.
M&L for replacement of gate/butterfly valve 25mm dia of cast copper alloy including taking down old complete all as specified and directed.
M & L for replacement of CI non return valve of size 100mm dia including flage and Nut, bolts, wahsher etc including taking down old complete all as specified and directed by Engr in charge.
M & L for replacement of CI sluice valve class PN 1.6 of size 100mm dia including flage and Nut, bolts, wahsher etc including taking down old complete all as specified and directed by Engr in charge.
M & L for replacement of Fire Brigade inlet connection 2 way if size 80mm dia including Nut, bolts, wahsher etc including taking down old complete all as specified and directed by Engr in charge.
M & L for wheather protective cover for 15 HP Centrifugal/ Jockey Pump made out of MS sheet of 3.15mm thick of size 1.2M x 1.0M screwed over MS Angle of size 30mm x 30mm x 5mm having four legs grouted with nuts and bolts with suitable height for proper working space including painting of two coat of synthic enamelled paint over ove coat of red oxide etc complete all as specified and directed by Engr in Charge.
M & L for replacement of Fire alarm control panel complying with BS EN 54 two loop panel of capacity from 99 detectors & 99 modules for 8 zone to detect 07 floor Addressable manual call point and modulesetc including taking down old complete all as specified and directed by Engr in charge.
M&L for replacement of Power contactor, 3 pole, MNX 22 type (AC3 rating 22 Amp and AC1 rating 32 Amp as per Cat No CS94980 of make L & T including taking down old & unserviceable complete all as specified and directed.
M&L for replacement of Bimetal Over load Relay, 3 pole, MN-2 direct mounting on MNX-22 type of relay range 14-23 Amp as per Cat No SS94144OODO of make L & T including taking down old & unserviceable complete all as specified and directed.
M&L for Single Phase Preventer, VSP2 type, 415 volts, 50 Hz including taking down old & unserviceable complete all as specified and directed.
M&L for MCB TP, 63 Amps, 415 volts including taking down old & unserviceable complete all as specified and directed.
M&L for MCCB TP, 100 Amps, 415 volts, breaking capacity 25 KA including taking down old & unserviceable complete all as specified and directed.
M&L for Submain wiring in PVC conduit with 2 x 2.5 Sqmm and 1x2.5 sq. mm earth wire wire copper conductor multistranded, run through existing PVC conduit not less than 20mm dia complete all as specified and directed.
M&L for Submain wiring in In existing surface/recessed steel/PVC conduit with 2 x 2.5 Sqmm and 1 x 2.5 sqmm earth wire wire copper conductor multistranded, PVC conduit not less than 20mm dia complete all as specified and directed.
M&L for Fire alarm MS Hooter including taking down old & unserviceable complete all as specified and directed.
M & L for replacement of Pressure gauge 4"dial 0-14 kgs rating complete all as specified and directed.
M & L for replacement of Pressure switch Universal type (HPLP) complete all as specified and directed.
M & L for replacement of Addressable manual call point resettable type coplete all as specified and directed.
M&L for replacement of fire extinguisher Carbon Dioxide (CO2) type of capacity 4.5 Kgs incl fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn etc complete all as specified and directed.
M&L for replacement of fire extinguisher Dry Chemical Powder type of capacity 6 Kgs incl fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn etc complete all as specified and directed.
M&L for replacement of fire extinguisher Gas Cartridge type of capacity 9 Kgs incl fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn etc complete all as specified and directed.
NOTE : Sample approval to be obtained prior to supply & fixing at site
Net Contract Sum will be after deducting Sch of Credit of Rs 1,25,670.00
Goyal Enterprises
FIRE PROTECTION SYSTEM
J.P. Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .