Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC | ₹1.7 Cr | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹1.8 Cr+₹7.4 L (4.35%)Rejected-Finance | ₹1.8 Cr+₹7.4 L (4.35%) | L2 | Rejected-Finance L2 Bid |
| 3 | L3₹2.0 Cr+₹27.1 L (16.0%)Rejected-Finance | ₹2.0 Cr+₹27.1 L (16.0%) | L3 | Rejected-Finance L3 Bid |
| 4 | Rejected-Technical | - | - | Rejected-Technical Does not meet PQ criteria. |
| 5 | Rejected-Technical | - | - | Rejected-Technical Does not meet PQ criteria. |
Tender Value
₹2.0 Cr
EMD Value
₹3.9 L
Closing Date
16 Nov 2022, 6:00 pmClosed
AGM (E-E)
Airports Authority of India, Lilabari Airport, North Lakhimpur, Assam
Provision of Solar Power Plant at Lilabari Airport
2022_AAI_131515_1
AAI/LBR/AGM(EE)/Solar/CW-03
Open Tender
Electrical Works
Item Rate
180 days
AAI, Lilabari Airport
Please refer Tender documents.
24 documents required · 24 mandatory
₹1,180
₹3.9 L
27 May 2024
14 Oct 2022
18 Nov 2022
15 Oct 2022
16 Nov 2022
15 Oct 2022
15 Oct 2022 - 30 Oct 2022
Amount
Design, Detailed Engineering, Supply, Installation, Testing and Commissioning of Grid Connected Carport type Solar PV Power Generation Plant of 170 KWp capacity with structure made up of aesthetically appealing hot dip GaIvanised GI steel structure of min. 85 micron with PV modules of minimum 540Wp, Mono PERC half cut, Minimum Efficiency: 20.90%, suitable for 1500 VDC, fixed in anodized aluminium frame complete as required including elevated structural support systems, foundation for all components after proper soil investigation/treatment as per site conditions, proper Communication, Data, Control, Power Cables & Safety System for reverse power protection, min. IP65 rated DC DB/JB for connection of modules to inverters through DC copper cables of suitable capacity laid in heavy duty CPVC/UPVC /HDPE pipes, Power Conditioning Units, String Monitoring Units, Meters, Surge & Lightning Protection System (as per NBC 2016), Earthing of modules & structures, Water cleaning system with proper drainage, LT/HT evacuation & injection at suitable injection point as per site conditions through cables, switchgears of suitable capacity for minimal voltage drop/losses, End terminations including modification of existing LT Panel (if required) (cable laying should be in HDPE pipes of suitable size as per site conditions, MNRE guidlines & revelent IEC 62548 & IEC 61215 ,62804), Auxiliary & Control Supply System, Data Acquisition system (complete with Hardware, Software, Switchgear, Cabling, Air Conditioning of room etc.) for local & remote monitoring, communication & control cabling alongwith providing Fire Extinguishers of required numbers & capacity, LED type Lighting for general illumination in the car shed i/c wiring / cabling, MCBs, DBs, Switchs etc, Plant Solar Radiation & Environment Monitoring System, Shadow Analysis, Glare Analysis for safe flight operations, Clearance from DISCOM and approvals from other Statuatory Agencies, Transportation & Insurance of material etc. and any other items/accessories/clearances/services required for successful commissioning of power plant on "Turnkey basis" complete in all respects as per the technical specifications, terms & conditions specified in the tender document and handing over the Solar PV Power Generation System to AAI. The complete system shall be under Defect Liability Period (DLP) of 02 years. Location: Lilabari Airport, North Lakhimpur, Assam Distance between LT Evacuation point and nearest point of solar power plant installation : 75 mtrs. approx. (45 mtrs approx. in ground in DWC HDPE pipe and 30 mtrs approx. in hard surface in HDPE/GI pipe to be laid by suitable means as per site conditions).
All inclusive Comprehensive Maintenance for 08 years (after completion of DLP of 02 years) and Operation for 10 years (from date of commissioning & Handing over) of the above installed complete Solar PV Power Plant with all installations/accessories as mentioned in Item No-1 including providing of required manpower for Operation & Routine maintenance (min. 01 no. skilled Technician) including cleaning of modules, monitoring / recording the solar energy generation data and maintenance of proper records etc. as required as per the directions of EIC.
1st Year (1st year during DLP )
2nd Year (2nd year during DLP )
3rd Year (1st year after DLP )
4th Year (2nd year after DLP )
5th Year (3rd year after DLP )
6th Year (4th year after DLP )
7th Year (5th year after DLP )
8th Year (6th year after DLP )
9th Year (7th year after DLP )
10th Year (8th year after DLP )
Samved Energy Systems Private Limited
Current Infraprojects Private Limited
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .