| 3 | L3₹6.1 L+₹55,656 (10.0%)Accepted-Finance 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L3 | Accepted-Finance Accepted financial bid | |
| 4 | L4₹6.3 L+₹74,067 (13.4%)Accepted-Finance 5 DARSHANI GATE DEHRADUN PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Accepted-Finance Accepted financial bid | |
| 5 | L5₹6.7 L+₹1.2 L (21.1%)Accepted-Finance | L5 | Accepted-Finance Accepted financial bid |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
29 Mar 2022, 6:00 pmClosed
GE (MES) ROORKEE
Garrison Engineer Military Engineer Services Roorkee
REPAIR MAINT OF STORAGE WATER HEATER SOLAR WATER HEATER SUMMER AND COOLING APPLIANCES AT RTS AND DEPOT SAHARANPUR UNDER GE ROORKEE
2022_MES_511424_1
8392/061/E8
Open Tender
Civil Works
Item Rate
180 days
Roorkee
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (MES) Roorkee
₹14,000
Yes
31 Mar 2022
2 Mar 2022
31 Mar 2022
2 Mar 2022
29 Mar 2022
16 Mar 2022
Amount
Taking down existing unserviceable geysers of any make and capacity carefully and transporting to MES E/M yard RTS & Depot Saharanpur, dismantling the same for inspection, taking out all unserviceable and burnt spare parts, de-scaling and cleaning of tank thoroughly with washing compound or liquid solution, preparing surfaces for painting and applying one coat of milky white synthetic enamel paint with spray machine, writing MES No. etc as per existing pattern with black synthetic enamel paint, transporting back and re-fixed in the original position complete all as specified and directed by Engineer-in-Charge. Note:- (i) Spare parts shall be measured and paid for separately at S&F rates under respective item of Schedule 'A', however minor items which are not catered in this schedule, the cost of the same shall be deemed to be included in the unit rate of this item. (ii) The contractor or his authorised representative shall report to E/M complaint cell at 8.30 Hrs on all working days to collect the complaint/Job slips and shall deposit the same after completion of the job duly signed by the users. (iii) Repair works to geysers shall be carried out at workshop in E/M yard. (iv) Repair works of geyser shall be completed and re-fixed within 24 Hrs after receipt of complaint slip. If the contactor fails to complete the job within stipulated time, a penalty of Rs 500/- shall be imposed per day for each complaint and the same shall be recovered from the contractor's dues.
Supply only geyser Vertical type of capacity 25 ltrs, Single phase, 240 Volts, of approved colour with auto cut-off and ajustable temparture complete all as specified and directed. Notes:- (i) The cost of taking down old unserviceable geysers and fixing of new geysers supplied is included in Srl item No. 1.00 above. (ii) Old unserviceable geysers retrieved in replacement shall be deposited to E/M store yard RTS & Depot Saharanpur.
S&F heating element 2.0 KW, 220 / 230 Volts any type / shape (Cup type round) (ISI marked) complete all as specified and directed.
S&F heating element 2.0 KW, 220 / 230 Volts any type / shape (Cup type triangular) (ISI marked) complete all as specified and directed.
S&F element holding clamp suitable for 25 / 35 / 50 liters capacity geysers complete all as specified and directed.
S&F thermostat cone type (ISI marked) complete all as specified and directed.
S&F thermostat switch coil type (ISI marked) complete all as specified and directed.
S&F brass head assembly having 8 to 9 holes suitable for 25 liters capacity geyser of any make complete all as specified and directed.
S&F head assembly along with integrated heating element and thermostate (ISI marked) complete all as specified and directed.
S&F brass safety plug (ISI marked) suitable for 25 / 35 / 50 liters capacity geysers complete all as specified and directed.
S&F mild steel spacer ring suitable for 25 / 35 / 50 liters capacity geyser complete all as specified and directed.
S&F round shaped rubber gasket having 8 to 9 holes, suitable for 25 / 35 / 50 liters capacity geyser complete all as specified and directed.
S&F neon lamp (Red & Green) round / square in shape suitable for 25 / 35 / 50 liters capacity geysers complete all as specified and directed.
S&F 15mm dia bore brass body pressure release valve (ISI marked) suitable for 15 mm bore pipe line for cold water connection in storage geyser complete all as specified and directed. Notes applicable to Srl item Nos 3.00 to 14.00:- (i) The cost of taking down old unserviceable spare parts is included in serial item No. 1.00 above and credit for the same shall be recovered as per Schedule of Credit.
S&F in repairs, 15mm dia bore brass chromium plated connection 450mm long with chromium plated adopters and washers at both ends complete all as specified and directed.
S&F in repairs, 15mm dia bore brass chromium plated connection 600mm long with chromium plated adopters and washers at both ends complete all as specified and directed.
S&F in repairs, 15mm dia 450 mm long heavy duty PVC connection suitable for cold water with PTMT nuts & washers at both ends complete all as specified and directed.
S&F in repairs 600 mm long heavy duty PVC connection suitable for cold water supply with two Nos. PTMT nuts alongwith PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
M&L for repairing of inner copper tank / container of geyser by brazing not exceeding 4 cm in length complete all as specified and directed.
S&F in replacement, stainless steel inner shell (ISI Marked) suitable for 25 liters capacity geyser complete all as specified and directed.
M&L for submain wiring, concealed with two runs of single core FRLS PVC insulated and unsheathed multi-stranded, copper conductor cable of size 4.0 sqmm LT, 1100V grade, drawn through and including PVC non metallic conduit of 20 mm / suitable dia with all accessories and fittings and one run of 4.0 Sqmm single core FRLS multi stranded copper conductor cable as earth continuity conductor including cutting chases and making good in cement mortar (1:3) to match the existing surfaces including necessary surface finishes with two coats of white wash or distempering of any type over a coat of primer to match the existing finishes complete all as specified and directed. Note:- (i) Two runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. (ii) Cable required for connection to DBs shall be deemed to be included and shall not be measured separately.
S&F in repairs, PVC insulated round copper wire 3 core 2.5 Sqmm for making connection from storage geyser to industrial / power socket all as specified and directed.
S&F in repairs, plug top 3 pin 15 Amps for storage geyser complete all as specified and directed
S&F in repairs, single pole and neutral sheet metal enclosure with two pin and earth plug and socket including MCB Single Pole 20 Amps, 240 Volt and fixed flush in wall suitable for geyser complete all as specified and directed.
Taking down carefully solar water heating system of capacity 200 to 600 liters per day of any make, dismantling the same for inspection, taking out all unserviceable and burnt spare parts, de-scaling and cleaning of stainless steel tank thoroughly with washing compound or liquid solution, applying one coat of synthetic enamel paint with sprayer after preparation of surface, writing work as per existing pattern with black synthetic enamel paint, including replacement of unservicable element, tore glass tube and heat resistant insulating material as per existing sizes, type and watt and re-fixing of solar water heating system at its original position complete all as specified and directed.
Taking up or down (from wall / trenches / floor) existing 15mm dia GI tubing and connections and removing from site after recovery of credit and S&F new 15mm dia bore GI tubing medium grade for making connection from storage geyser to bib tap etc including shaddles and screws complete all as specified and directed.
S&F in repairs, 15mm dia bore cast iron bib tap with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule for hot water supply point complete all as specified and directed.
SF in repairs, 15mm dia bore angle valve cromium plated, screwed down high pressure with or without lettered Hot and Cold with long screwed shanks and fly-nut, screwed for iron pipe complete all as specified and directed.
S&F in repairs, 25mm dia bore gun metal pressure release valve suitable for 25 mm dia bore pipe for solar hot water supply complete all as specified and directed.
S&F in repalcement, Solar Water heating element 3 KW suitable for hot water storage tank and making electric connection complete all as specified and directed.
S&F in replacement, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, 2 core 16 Sqmm cross sectional area including fixing in any position with & including GI shaddels and screws complete all as specified and directed.
Dismantling old water tank of 500 ltrs capacity of any description and removing from site after recovery of credit and S&F new 500 ltrs capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) including 20mm dia bore PTMT ball valve, hoisted and fixed in position as specified in SSR Part I complete all as specified and directed.
S&F in replacement, mild steel plain black sheet 1.6 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams including bending or turning up, mitred angles, etc all as specified and directed by Engineer-in-Charge at site
Taking out existing Refrigerator of any capacity and carryingout maintenance, servicing and overhauling of any nature including cleaning of air filters, checking of wiring, rectification of defects, replacement of defective parts and re-fixing in the same position complete all as specified and directed. Note:- (i) Spare parts shall be measured and paid for separately under relevant items of schedule 'A'. (b) Cost of small pieces of wire terminals, soldering / clippings required at site for proper functioning of the equipment shall be deemed to be included quoted rates under this items.
All as per Srl item No. 34.00 above but for Water Cooler of any capacity.
All as per Srl item No. 34.00 but for Desert Cooler of any capacity.
Dismantling of existing blower fan motor of Window / Split type AC 1.5/2.0 TR, cutting burnt coils and taking out from the stator, cleaning the slots using primer, rewinding using supper enamelled copper wire of existing size and gauge including insulation materials, replacing gun metal bush (front and rear) and re-assembling all accessories and testing complete all as directed by Engineer-in-Charge.
M&L for repairs to body and base of water cooler including providing plain MS sheet not less than 22 gauge and angle iron 20x20 mm of existing thickness and size including necessary welding, brazing and replacement of glass wool complete all as specified and directed by Engineer-in-Charge.
M&L for preparing old painted surfaces of water cooler of any capcity by scrapping old bubbled/peeled off paint, cleaning the surface, levelling and applying one coat of synthetic enamel paint over one coat of primer with the help of compressure spray machine as per existing colour at site including writing MES/SM/SL No. with black synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 39.00 above but Desert Coolers of any capacity.
Taking out old unserviceable compressure from Refrigerator of capacity upto 310 liters and S&F new sealed compressor of existing make suitable for working on SP, 50 Hz, AC supply including making necessary connection of refrigerant pipe, electric connection and testing for leakage etc complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 41.00 above but for Water cooler of capacity 40/80 Ltrs
All as per Srl item No. 41.00 above but for Window /Split type AC of Capacity 1.5 Ton
All as per Srl item No. 41.00 above but for Window /Split type AC of Capacity 2.0 Ton
M&L for jointing capillary tubes, filter strainer by brazing, cleaning / flushing whole system, checking any leakage and make good including testing 350 PSI for Window / Split type AC up to 2.0 TR capacity complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 45.00 above but for Water Cooler up to 40/80 Ltrs
All as per Srl item No. 45.00 above but for Refrigerator of capacity up to 310 Ltrs
S&F following materials/accessories in replacement suitable for 1.5/2.0 TR capacity window type / split type AC complete all as specified and directed by Engineer-in-Charge:-
Running capacitor 36 mfd
Running capacitor 45 mfd + 06 mfd
Filter strainer (copper)
Starting relay
Air filter made of plastic frame and nylon net
Condenser fan & blower fan for split type AC up to 2 Ton Capacity (as per existing make)
Blower fan (as per existing make)
Blower motor
PCB Board with display for split type AC (as per existing make)
Front grill
Swing motor
Starting capacitor 80/100 Mfd 240 Volt
Labour only for repairing and attending the complaint of Split type AC / Window type AC / Water Cooler / Refrigerator by highly skilled tradesmen and carry out minor repair and making functional complete all as specified and directed by Engineer-in-Charge at site. Note- Replacement of spare parts shall be measured and paid for separately under respective item of Schedule 'A'.
S&F following materials/accessories in replacement, suitable for various capacity refrigerator complete all as specified and directed by Engineer-in-Charge:-
Pin/screw type lamp holder.
Bulb 15 watt (Pin/Thread type)
Ice tray with separator (set of two)
Open type relay with overload protector
Thermostat auto defrost
Capillary tube (copper) 2.5 mtr 0.31 mm bore
Filter strainer (copper)
Ice Chamber (Cooling coil) capacity up to 310 Ltr.
Condenser coil
S&F in replacement the following materials/accessories suitable for various capacity water cooler complete all as specified and directed by Engineer-in-Charge:-
Push tap any colour high pressure of PTMT screwed for iron pipe and fixed, (Minimum weight 15mm-47gms/ 20mm- 75gms) 15 mm size.
Top cover gasket (3 meter each cooler)
Condenser Fan made of aluminium blade
Thermostat
PVC Float valve Brass 15 mm size
Over load protector (Part No 1022)
Blower motor
S&F in replacement the following materials/accessories suitable for various capacity desert cooler complete all as specified and directed by Engineer-in-Charge:-
Water lifting pump, plastic body, 240 Volt, Single phase submersible type suitable for Desert coolers 20"/16". Make : Khaitan or equivalent
Cooler fan kit motor duly copper wounded (suitable for three fan blades) 240 volt 1/8 HP. 950 RPM, double ball bearing type.
Fan blade of GI sheet heavy duty suitable for desert cooler 20" / 16" size.
PVC transparent pipe set complete for distribution of water of desert cooler (having drooping elbow -3 Nos, distribution 3 way) as per existing size, including clamping by screw/strip all as specified and directed.
Speed regualtor knob 3 way suitable for desert cooler/window AC of existing make.
Switch Piano, flush type singhle pole, one way 5 Amps on desert coolers all as specified and directed.
Front grill made of 23 SWG GI sheet with and including air direction control system with knob, piano type switch, indicator lamp, complete suitable for 20"/16"/24" desert cooler.
Side grill made of 23 SWG GI sheet as per existing type and size suitable for 16"/20"/24 " desert coolers complete all as specified and directed.
Water storage tank made of 23 SWG GI sheet suitable for 16"/20'/24" desert cooler complete all as specified and directed.
Wood wool pad (set of three) suitable for desert cooler 24" / 20" / 16" including binding properly with GI Chicken wire mesh .
Honey comb pad (set of three) suitable for desert cooler 24" / 20" / 16" including binding properly with GI Chicken wire mesh.
S&F in replacement, PVC insulated multistranded Copper Cable 3 core 4.00 Sqmm size for AC / Water cooler complete all as specified and directed by Engineer-in-Charge:-
S&F in replacement, PVC insulated multistranded Copper Cable 3 core 2.5 Sqmm size for refrigerator, desert cooler and voltage stabilizer complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking out voltage stabilizer transformer unit, electric circuit board, all cable connections, complete overhauling of the system of 4 KVA capacity stabilizer including repairing/replacement of push on switch, transistor, capacitor, relay transistor, diode, condenser, voltmeter/Ammeter, PVC connector, indicator lamp, cut-out, MCB, complete parts including testing & commissioning and transportation charges from site to workshop and back complete all as directed by engineer-in-Charge.
M&L for rewinding of transformer of capacity 4 KVA complete all as directed by engineer-in-Charge.
M&L for charging of refrigerant in Window / Split type A/Cs up to 2 TR / Water cooler / Refrigerator of any make carefully duly taking necessary precautions, making necessary copper tubing connections for refrigerant lines and making leak proof including testing for leakage and optimum grill temperature complete all as specified by the manufacturer and directed by Engineer-in-Charge. Note:- During the currency of the contract, if the gas leakedout, the same shall be recharged by the contractor without any extra cost and the cost of the same shall be deemed to be included in quoted rates.
Window / Split type AC up to 1.5 TR capacity
Window / Split type AC up to 2.0 TR capacity
Water cooler 40/80 ltrs capacity
Refrigerator 300/310 ltrs capacity
S&F in replacement, Voltage stabilizer of 4 KVA capacity, Single phase, 240 Volts, of approved colour with auto cut-off complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking out exiting defective copper tubing off size of any description and fixed in any position and S&F new copper tubing special annealed pressure copper purity min 99.9% and making flairing at both ends for connections including brass nut of any size as required and insulating material etc and testing complete all as Specified and directed.
Repair/Replacement of defective electronic components in PCB circuit plate of 1.5 2.0 Ton Split type AC of existing model of any make complete all as directed.
SHRI RAM ENTERPRISES
VIJAY ENTERPRISES
Tarachand gurudutt
PANWAR CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .