| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹30.5 L+₹46,757.59 (1.56%)Rejected-Finance VILL POST MANJHULI PS BAKHITIYARPUR KHUSRUPUR DIST PATNA BIHAR 803202 | NALANDA | BIHAR | 803202 | L2 | Rejected-Finance Quoted amount is more than L1 | |
| 3 | L3₹32.2 L+₹2.2 L (7.16%)Rejected-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L3 | Rejected-Finance Quoted amount is more than L1 | |
| 4 | L4₹33.8 L+₹3.7 L (12.4%)Rejected-Finance | L4 | Rejected-Finance Quoted amount is more than L1 | |
| 5 | L5₹35.2 L+₹5.2 L (17.2%)Rejected-Finance | L5 | Rejected-Finance Quoted amount is more than L1 |
Tender Value
₹28.5 L
EMD Value
₹57,000
Closing Date
27 Oct 2022, 6:00 pmClosed
Major S Rakesh
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
SPL REP TO BLDG NOS T13 T15 T17 AND T18 (OTM ACCN) PROVN OF HARD STANDING (50 X 10 MTR) FOR MT VEHICLES AND PROVN OF PCC DRAIN 100 MTR LONG FOR BLDG NO T302 OF 23 JAK RIF AT RANCHI MIL STN
2022_MES_556635_1
8200/1430/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class D Cat a (i)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹57,000
Yes
24 Dec 2022
8 Oct 2022
29 Oct 2022
9 Oct 2022
27 Oct 2022
22 Oct 2022
Amount
Dismantling of AC sheet (corrugated or semi corrugated etc) including AC ridges as in roof covering complete all as specified and directed.
Dismantling timber scantling 40 sqcm and over in section in any position in framed work complete all as specified and directed.
Dismantling of wall and ceiling board any thickness/description including cover fillet complete all as specified and directed.
M&L for roughening surface of old concrete floor by picking, sweeping cleaning and washing down with to remove dust complete all as specified and directed.
M&L for brushing neat cement slurry with 3.0 kg of cement per Sq Mtr.
Demolition of cement concrete (reinforced) any description and in any position.
Demolition of brick wk masonry built in cement mortar including all quoins arches pillars etc
Dimantling Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls/concrete surface etc. including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area n’exc1.5 Sqm and removing from site complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exc1.5 Sqm but n.exc 4.00 Sqm each and removing from site complete all as specified and directed.
S&F Plain, galvanised, mild steel sheeting 0.63 mm thick, in ridges,hips, valley gutters,chajjas, drip and straight flashings with grade of zink coating 275complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated/ semi - corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering fixed with coach screw as per manufacturers instrution complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering as ridge/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre incl 2mm dia G.I. ( upto 1200 mm length ) adjusting level to Purlins/ Rafter complete all as specified and directed.
S&F for hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out GI flat 40X3mm size 60mm long and expension hold fastners 12.5mm dia 40mm long complete all as specified and directed.
M&L 4mm thick non asbestos fibre cement designer building board of size 600X600 fixed or laid/inserted to timber/GI/Aluminium framework fixed in ceiling flat or sloping complete all as specified and directed.
M&L 75mm thick PCC type C2 1:3:6 (using 40mm graded stone agg) as in plinth protection/Path/floor finishing surface of concrete topping even and fair without using extra cement complete all as specified and directed.
M&L, 15mm thick screed bed or bedding layer of mortar in CM (1:6) for lying floor finishes and surface fair and even complete all as specified and directed.
M&L, 10mm thick rendering as screed bed or bedding layer of mortar in CM (1:4) for lying for vertical surface fair and even complete all as specified and directed.
M&L Non - skid Ceramic tiles of any colour/shade 7 to 8 mm thick area of each tile exceeding 0.18sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles complete all as specified and directed.
All as per above item no 21 as in vertical surface.
Cutting holes in brickwalls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required not exc. half brick complete all as specified and directed.
M & L Brick wk with sub class ‘B’ bricks straight or curved on plan exc. 6m means radius in CM 1:6, complete all as specified and directed.
M&L Brick work with sub class 'B' Brick straight or curved on plain to any radius in half brick thick wall built in cm 1:4, complete all as specified and directed.
M & L, 10mm thick rendering on fair faces of brick work/concrete surface in CM (1:6) surface finished fair & even complete all as specified and directed.
M & L, 15mm thick rendering on fair faces of brick work/concrete surface in CM (1:4) with applying water proofing compound (As per manufrature instruction) surface finished fair & even complete all as specified and directed..(WPC will be paid saperatelly)
Supply only liquid water proofing compound.
M & L RCC (1:2:4) type B-1using 20 mm graded stone aggregate as in slab supported on wall ,Chajjas,deck slab Shelves/tank staging etc.
Use & waste frame work to soffits of suspended slab such as floor or roof slab, chajjas and similar work not exc 200 mm thick (Horizontal or slopeing) rough finished complete all as specified and directed.
M & L Mild steel bars 10mm dia TMT Bars and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming and complete all as specified and directed.
All as item No 31 as above but, 6mm to 8mm dia.
M&L Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to fe.290.Gde-E-165 complete all as specified and directed.
S&F Roof trusses (framed), purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) incl distance pieces, cleats etc complete Fe 410-W(Gde E-250) quality-A complete all as specified and directed.
S & F 2nd class hard wood plain solid, straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints supplied and fitted to chowkats complete all as specified and directed.
M&L Providing, cement concrete type B0 1:2:4 (12.5 mm graded aggreate) in filling of pressed steel frame , coping, fixing of hold fast etc similar work complete all as specified and directed.
S&F 35mm thick 2nd class hard wood, Plain framed, panelled shutter (three panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 2nd class hard wood 35 mm thick glazed & skelton shutter (any no of pannel) open rebated and prepared to receive glass gauge etc with sush bar edges to framing plain chamfered or receive glass gauge etc with sash bar edge of framing plain chamfered or rounded fitted with cut and mitered beads for securing glass etc size of member of shutter as specified in SSR Part-I section 8 clause 8.24 (a). complete all as specified and directed.
S & F 100 mm Butt hinges medium weight medium cold rolled mild steel. complete all as specified and directed.
S&F 150 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S&F of 150 mm size extructed brass handles, fabricated type polished and complete all as specified and directed.
S&F 250mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
S & F 3mm thick plain sheet glass ordinary quality & glazing with oil putty n.exc 0.50 Sqm in each pane complete all as specified and directed.
S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanized wire staples over steel windows and gauzed door complete all as specified and directed.
M & L Steel window with side hung shutter including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dove tailed or welded (including two nos tower bolts 125mm in each leaf and one nos MS flate iron 25x 3mm handle in each leaf complete all as specified and directed.
M & L Steel window with side hung shutter including projecting type hinges with steel handle and steel peg stay, complete without glazing bars, dove tailed or welded (including two nos tower bolts 125mm in each leaf and one nos MS flat iron 25x 3mm handle in each leaf complete all as specified and directed.
S&F Flat iron / angle iron for wind tie, hold fast to fixed door/window complete all as specified and directed.
M & L preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty complete all as specified and directed.
M & L preparation of complete removal of existing treatement from old plastered surface of wall and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty complete all as specified and directed.
M & L preparation of new surface of wall and applying two coat of cement base paint, in any colour complete all as specified and directed.
Complete removal of existing treatment of walls by washing rubbing down & stopping of painted surfaces and applying two coat of cement base paint, in any colour complete all as specified and directed..
M&L, applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of newly steel surfaces of any description over 10cm width or girth not otherwise described complete all as specified and directed.
M&L, applying two coats of synthetic enamel paint over a coat of pink primer including preparation of newly wooden surfaces of any description exc10cm width or girth not otherwise described complete all as specified and directed.
Surface excavation n.exc 30cm deep and average 15cm deep and getting out in soft/loose soil.
Rolling and consolidating formation surface in cutting with power roller exc 8 tonne and n exc 12 tonne.
Removing excavated materials not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soil.
M&L 150mm thick hardcore using broken stone aggregate of gauge n exc. 63mm, deposited, spread and levelled in layer n exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L 150mm thick PCC type E-2, 1:5:10 (using 40mm graded stone agg) as in sub base floor surface complete all as specified and directed.
M&L 100mm thick PCC type B-2, 1:2:4 (using 40mm graded stone agg) as in floor making finished fair and even without using extra cement surface complete all as specified and directed.
M&L forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound Grade 'A' for 100mm thick concrete slab complete all as specified and directed.
M&L forming contraction (Dummy) joints 100mm deep x 10mm wide filled with sealing compound Grade 'A', complete all as specified and directed.
M&L PCC type D2 1:4:8 (using 40mm graded stone agg) as in foundation, filling and mass concrete, complete all as specified and directed.
M & L Brick wk with sub class ‘B’ bricks straight or curved on plan exc. 6m means radius in CM 1:6, complete all as specified and directed.
M & L, 15mm thick rendering on fair faces of brick work/concrete surface in CM (1:6) surface is to be finished even and smooth, complete all as specified and directed.
M & L preparation of new surface of wall and applying three coat of white wash complete all as specified and directed.
Exavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 Mtr in depth for foundation, etc n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose of soil.
M&L for Plain cement Concrete C2,1:3:6 (40mm graded aggregate) as in surface channels and drains. Complete all as specified and directed.
M & L PCC 1:2:4 type B-1 using 20 mm graded store aggregate as in coping and channel including use and waste of form work where necessary complete all as specified and directed.
M & L 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces, surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for extra forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra, including forms, moulds, mitred/ stopped end etc complete all as specified and directed.
Returning filling in soft/loose soil in trenches after laying pipes construction of manhole etc including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick layer complete all as specified and directed.
Removing surplus soil to a distance n exc 50M and depositing where directed at a level not exc 1.5M above the starting point complete all as specified and directed.
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades complete all as specified and as directed.
M&L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLSH multi stranded conductor cable in and including Concealed PVC conduit of size 20/25mm ISI marked inclusive of tees ,bend ,elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3 mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :-
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
S & F for Switch Piano type single pole 5 amp, 230 Volts complete all as specified and directed at site.
S & F for socket outlet 2 in 1 , 5 pin, 5 amp, 230 Volts complete all as specified and directed at site.
S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and directed
S & F for stepped type electronic fan regulator flush type complete all as specified and directed at site.
M & L Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Labour only for refixing the ceiling fan/ Exhaust fan obtained from item No 75 above with replacement of unsv 3 core PVC insulated PVC sheated 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal including over hauling the fan, painting of ceiling fans complete with two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc. complete all as specified and as directed
S & F wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make :- Make Crompton, Philips, Havells.
S & F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed. Make :- Crompton , Philips, Havells.
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 building security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 40 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade required dia 1.5 mtr long bend to required shape complete all as specified and directed . Make- Cromoton, Havells, Philips
S & F for Lamp holder, PVC body suitable for batten fitting complete all as specified and as directed.
M& L earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised earth wire 4mm dia by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No 3 of MES Schdule Part-I connected to earthing point and testing on completion with and including 15mm bore light grade GI protection pipe (upto 7.5 meter beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C-1 with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore medium grade GI watering pipe common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed at site.
M/S JAI MATA DEE CONTRUCTION CO.
Raj Construction
M/S ABDHESH CONSTRUCTION
jai maavindwashni sales & supply
Rajeev Ranjan
M/S DILIP KUMAR
india trading company
Bihar traders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .