Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | L1 | Accepted-AOC OK | |
| 2 | L2₹17.3 L+₹1.4 L (8.56%)Rejected-AOC | L2 | Rejected-AOC OK | |
| 3 | L3₹21.4 L+₹5.5 L (34.5%)Rejected-AOC | L3 | Rejected-AOC OK | |
| 4 | L4₹21.9 L+₹6.0 L (37.6%)Rejected-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L4 | Rejected-AOC OK |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
20 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF Bhisiana
HQ CWE AF BHISIANA
CWE(BHI)/BHI-23/2022-23
2022_MES_539746_1
CWE(BHI)/BHI-23/2022-23
Open Tender
Civil Works
Item Rate
270 days
AF Bhisiana
ALL AS PER COVER 1
6 documents required · 6 mandatory
₹500
Yes
GE AF Bhisiana
₹70,000
Yes
29 Sept 2022
21 Jul 2022
22 Aug 2022
21 Jul 2022
20 Aug 2022
6 Aug 2022
21 Jul 2022 - 28 Jul 2022
Amount
M & L for servicing, calibration and testing of 11KV HT relay provided with VCBs HT panel of any make and type such as instantaneous earth fault, auxiliary relay, earth fault, under voltage, over current relay and adjustment the time for proper tripping with respect of MES/State Electricity Board incoming tripping with the relay testing equipment by the authorized service engineer and shall submit necessary certificate for the same complete all as specified & directed.
M & L for servicing, of HT 11 KV 630 amps VCBs trolley complete taking out from HT panel, opening all covers and cleaning internally and externally all contacts, spring and motor charging mechanism, opening of tripping closing system including adjustment, tightening & setting of contact male and female & inserting it in its original position & VCB out put side connectivity busbars from CT to cable to be insulated by using HT heat shrinkable sleeve (11000 V grade ) and testing etc. complete including replacement of glass of inspection window complete all as specified & directed.
M & L for servicing, of SF-6 circuit breaker including cleaning all parts internally and externally checking of the proper tension of the springs mechanism, tightening of connection of moving/ fixed contract, floating contacts, charging system and checking of SF-6 gas for any leakage and re-fixing it on its original position and including testing by the authorized service engineer and shall submit necessary certificate for the same complete all as specified & directed. NOTE: The cost of minor part if any required to replace is included in quoted rate.
M&L for servicing and renewal/replacement of defective parts of oil type Transformer 750 KVA, 11/0.433 KV indoor type/out door type by disconnecting of HT/LT bus bar/Cable connections, opening of tap cover, cleaning , tightening nuts, bolts, bushings, replacing gaskets and other insulated surfaces be wiped clean with a dry cloth and all connections must be checked for tightness after cleaning up to the satisfaction of Engr-in-Charge complete all as specified and as directed.
All as per srl item No. 4 here-in-before but for transformer capacity 400 to 500 KVA.
All as per srl item No. 4 here-in-before but for transformer capacity 100 to 315 KVA. Note:- Ser item no. 4 to 6 includes the under mentioned scope of work:- (a) Transformer must be meggered (b) Cleaning of transformer from inside. (c) Testing the Transformer for IR Values (d) Checking/servicing/calibration of WTI for healthiness. (e) Disconnection of Transformer HV/LV terminations for testing work and re-connections after completion of repair work. (f) Commissioning and necessary testing of transformer after completion of work.
M & L for attending breakdown /inspection of HT 11KV VCB by authorised service engineer to check and replace any spare parts related breakdown complete all as specified and as directed. Note for Ser item No. 1 to 7:- (i) Maintenance/repair shall be carried out by authorised service engineer. (ii) All Measuring equipments and T&P required shall be arranged by the contractor. (iii) any other activity/ minor items not listed/covered here above and required during /completing the work for smooth functiong of system will have to be arranged by Contractor himself and for this purpose no extra cost will be paid. (iv) Major Spare parts shall be paid separately under relative item as supply only. However fixing charges shall deemed to be included in this item (v) A sum of Rs. 5000/- will be recovered from the contractor for non rectification of breakdown/fault or replacement of any unserviceable spares after 12 hours from lodging of complaint telephonically or verbaly. (vi) Thereafter Rs. 1000/- will be added every day till rectification of fault or replacement of unserviceable spares as directed by the Engr-in-Charge.
Supply only in replacement Isolate contact assembly suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified & directed.
Supply only in replacement Auxiliary switch suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified & directed.
Supply only in replacement Earth contact assembly suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified & directed.
Supply only in replacement limit switch assembly suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified & directed.
Supply only in replacement Closing coil assembly for 11 KV HT VCB 630 Amp as per existing make and model complete all as specified & directed.
Supply only in replacement tripping coil assembly for 11 KV HT VCB 630 Amp as per existing make and model complete all as specified & directed.
Supply only in replacement Tripping/ Closing push button suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified & directed.
Supply only in replacement spring charged indicator suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified & directed.
Supply only in replacement Main shaft inter lock assembly suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified & directed.
Supply only in replacement Big cam with main shaft suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified & directed.
Supply only in replacement Big gear assembly suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified & directed.
Supply only in replacement Small gear assembly suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified & directed.
Supply only in replacement motor & gear assembly fixing for charging system 220 volts AC/DC or as per new model including all necessary modification suitable for 630 Amps HT VCB as per existing make and model complete all as specified & directed.
Supply only in replacement copper fixed contact, 630 Amps, I-type suitable for 630 Amps HT VCB as per existing make and model complete all as specified & directed.
Supply only in replacement copper fixed contact, 630 Amps, T-type suitable for 630 Amps HT VCB as per existing make and model complete all as specified & directed.
Supply only in replacement TNC switch suitable for operation of VCB 630 Amp of Crompton Greaves make installed in HT panel 11 KV as per existing make and model complete all as specified & directed.
Supply only in replacement of old space heater, ISI marked suitable for 11KV HT panel, complete all as specified & directed.
Supply only in replacement of old thermostat suitable for 11 KV HT panel complete all as specified & directed.
Supply only in replacement of push button with NO/NC contact suitable for capacitor panel complete all as specified & directed.
Supply and fix HT/LT cable route indicator made out of round CI embossed plate 100 mm dia 6 mm thick duly riveted with angle of size 40 x 40 x 6 mm and 60 cm long incl PCC for embedding 1:4:8 type D2 of size 30cmx30cmx30cm complete all as specified & directed.
Supply only in replacement 11 KV resin cast epoxy type current transformers (CTs) of ratio 200/100-5-5 Amps and class accuracy 0.5/5P10 or as per existing capacity including testing complete all as specified & directed.
Supply only in replacement of earth fault relay for HT breaker operating voltage 220 V DC with adjustable settings including cutting drilling to fix relay in existing panel door as per site requirement complete all as specified & directed.
All as per ser item No 31 here in before but for HT VCB main incomer.
Supply and fixing in replacement of electric hooter with all accessories suitable for working on HT Panel including using 2.5 Sqmm, FRLS. Multistranded PVC insulated copper cable for connection, complete all as specified & directed.
Supply and fixing in replacement of 24V / 16 A battery charger with battery bank (2 x battery of cap 35 AH) for CTVS 11 KV HT panel as existing and site requirement complete all as specified & directed.
M&L for repairing and making serviceable 110V/ 100AH battery charger of make AMARA RAJA Johnson Controls installed in PS-II sub station complete all as specified & directed.
Supply only transformer oil, low viscosity insulating oil for top up transformer of as per IS-335, complete all as specified & directed. (Note - The oil shall be supplied in sealed barrel only.)
Material and labour for testing the dielectric strength of transformer oil of the transformers installed at various sub stn at/on floor/pole before dehydration and dehydrating and filtering the transformer oil with dehydration machine to achieve dielectric strength of the oil up to 50 KV at 2.5 mm gap as per IS standard, complete all as specified & directed. Note : The transformer dehydration machine and dielectric strength testing machine shall be arranged/brought by contractor at site and no extra cost shall be paid to the contractor in this effect.
Supply only in replacement HV bushing with rod incl all accessories suitable for transformer of capacity upto 750 KVA complete with suitable gasket, complete all as specified & directed.
Supply only in replacement LV bushing with rod incl all accessories, suitable for transformer of capacity upto 750 KVA with copper strip along with suitable gasket, complete all as specified & directed.
Supply only in replacement of temperature gauge 0 C to 125 C for transformer installed at site with all accessories, complete all as specified & directed.
Supply only in replacement of Air breather assembly complete with fresh blue colour silica gel suitable for indoor/outdoor type transformer of capacity 500 KVA to 750 KVA capacity, complete all as specified & directed.
All as per srl item No. 41 here-in-before but for transformer capacity 400 to 500 KVA.
All as per srl item No. 41 here-in-before but for transformer capacity 25 to 315 KVA.
M&L for preparing old painted steel or iron surfaces of HT/ SF6 Panel any type, description by cleaning dirt, oil, grease etc, removing the old paint, rust by scratching with wire brush/emery paper etc., and apply two coat of synthetic enamel spray paint over a coat of red oxide of existing colour on out side body of the HT/ SF6 Panel and writing of letter SM/MES No etc. of 10 cm height and making all HT/LT electric connections and testing the same complete all as directed.
M&L for preparing old painted surface of transformer of outdoor / indoor type of capacity 500 KVA to 750 KVA, any type, description by cleaning dirt, oil, grease etc., removing the old paint, rust by scratching with wire brush / emery paper etc, after disconnecting HT/LT electric connection from both primary and secondary side of transformer and apply two coat of synthetic enamel spray paint of existing colour on out side body of the transformer and writing of letter HT/LT and SM MES No etc. of 10 cm height and making all HT/LT electric connections and testing the same, complete all as directed.
All as per srl item No. 45 here-in-before but for transformer capacity 400 to 500 KVA.
All as per srl item No. 45 here-in-before but for transformer capacity 100 KVA to 315 KVA. Note for Ser item No. 45 to 48:- (a) The compressor and spray machine etc. shall be arranged/ brought by contractor at site and no extra cost shall be paid to the contractor for this effect. (b) Volt meter, Ammeter, relays etc. on panel / Transformer should be covered properly at the time of painting and after painting if any damage to the existing display or any item then the same will be replaced by contractor with out any extra cost.
M&L for cross arms, bracings, supports, clamps, angle iron, flats and back plates fabricated from MS structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending (cold or hot), drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer, complete all as specified & directed.
M & L in replacement for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground(earth) pit not less than 2.25 meter deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized iron or wire of size 32x6 mm earthing lead by means of bolts, nuts check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Pt-I connected earthing test point/panel complete including PCC earth chamber using PCC(1:3:6) Type C-2 using graded stone aggregate 50mm thick, cast iron frame with CI cover, Funnel with watering pipe, wire mesh, copper lugs, excavation and earth work etc. complete all as specified and directed. Note: i) Rate included for Adequate quantity of charcoal dust, common salt and Testing commissioning including checking of earth continuity and earth result complete all as specified and as directed. ii) Rates for Main earthing lead from earth electrode to test point upto 7.5 metre will deemed to be included in quoted rates. iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Supply, spread, rolled and consolidated to gradient and camber of gravels 50 mm thick, including clearance of existing surface along with making clearance of 2 mtr surface side by side of HT fencing before spreading of gravels complete all as specified & directed.
M&L for 1.2 m x 1.8 m flex board and drawing of substation schematic diagram using standard drafting tool AutoCAD. One set of drawing shall be submitted to the Deptt for scrutiny of drawing and final prints of drawing shall be submitted thereafter complete all as specified and directed. this item includes the under mentioned scope of work:- i. Preparation of drawing of Substation schematic diagram using standard drafting tools AutoCAD. ii. Duly printed Flex board with MS frame of size 1.2 m x 1.8 m and other fixing accessories. iii. Submission of soft copy. iv. Submission of three hard copies of drawing prepared on A3 size paper.
Taking shut down of HT electric supply, disconnecting all electric connection from the main HT Panel and taking out HT XLPE cable of existing size carefully without damaging it from ducts / trenches. Cleaning of ducts, shifting/ Relaying of serviceable HT cable of any size and making all electric connection in HT panel complete all as specified and directed.
M&L for rough excavation not exceeding 1.5 m deep and getting out soft/loose soil complete all as specified & directed.
M&L for Cement concrete in foundations, filling and mass concrete type D2, 1:4:8 (40 mm graded aggregate) complete all as specified & directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified & directed.
M&L for 25mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) complete all as specified & directed.
M&L for rendering screed bed or bedding layer of cement plaster 1:4 of mortar 15 mm thick for laying floor finishes complete all as specified & directed.
M&L for rendering 15mm thick cement plaster in 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed.
Taking shutdown, disconnecting all electrical and earthing connections and carefully lifting existing serviceable transformer of capacity 315 KVA, outdoor type from old/ damaged foundation and shifting & mounting of the same at new foundation whereas directed by Engr In Charge and making all necessary electrical HT/LT and earthing connections incl replacement of worn out nut & bolts as required and testing of transformer to the satisfication of engr-in-Charge complete all as specified and directed. Note:- 1. Quoted rate is deemed to include cost of T&P/crane/Hydra machine and necessary manpower to shift the transformer without damaging at a place whereas directed, if any damage to the transformer or its part then the same will be replaced by contractor with out any extra cost. 2. Necessary arrangement/ electrical items/equipments and electric connections on temporary basis will be made by the contractor to provide uniterrupted power supply to the hospital. No extra payment will be made against the same.
M&L for demolition of old brickwork of foundation built in cement mortar of transformer after shifting of transformer from foundation and removing all the debris, broken bricks etc obtained from demolished foundation to nearby area to a distance n exc 100 m where directed and making the soil surface flat and clean by using the loader complete all as directed. [Note :- All the T&P required for the above jobs shall be arranged by the contractor at site and cost of the same is deemed to be included in the quoted rate]
M &L for checking the defective voltage stabilizer upto 10KVA to 250 KVA capacity at domestic and tech area after disconnecting the connections for minor repairs i,e servicing of bushings, removing damaged/defective parts requiring replacement , making internal connections , replacement of new cork gasket, packing nuts, bolts, washers etc, raining of oil, washing and cleaning duct, dit and sludge deposit etc. (Spare parts will be measured separately)
Supply only serviceable servo motor of voltage stablizer of capacity 10 KVA upto 50 KVA
Supply only servo motor of voltage stablizer of capacity above 50 KVA to 150 KVA
Supply only serviceable servo motor of voltage stablizer of capacity above 150 KVA to 250 KVA
Supply only peripheral component board of voltage stablizer of capacity above 10 KVA to 50 KVA
Supply only peripheral component board of voltage stablizer of capacity above 50 KVA to 150 KVA
Supply only peripheral component board of voltage stablizer of capacity above 150 KVA to 250 KVA
Supply only dimmer state contact above 10 KVA to 50 KVA voltage stablizer.
Supply only dimmer state contact above 50 KVA to150 KVA voltage stablizer.
Supply only dimmer state contact above 150 KVA to 250 KVA voltage stablizer.
Supply only auto manual switch suitable for any capacity/existing make for voltage stabilizer all as directed
Supply only indication lamp assy suitable for any capacity/existing make for voltage stabilizer all as directed
Supply only carbon set suitable for any capacity/existing make for voltage stabilizer all as directed
Supply and fixing PVC HT insulation tape
Supply, install, commissioning and testing of outdoor HT feeder pillar box 3.15 mm thick CRCA sheet weather and vermin proof CPRI approved with copper busbar 800 amps suitable for HT cable 11 KV 3 core of size upto 185 sqmm including provision of cable entries with glands locking arrangements and angle iron frame and legs of 90 cm long using 60x60x6 mm size MS angle iron fixed in floor in PCC 1:4: 8 type D2 base of appropriate size including necessary excavation earth work complete all as specified and directed by Engineer-in-Charge.(Note : size as per one incoming and three outgoing)
M&L for perodical inspection of 66/11 KV sub station servicing and maintenance of switch gears and caliberation of relay by senior Executive Enginner protection division Bathinda of any type voltage current (e) earth fault/relay/over current relay of 66 KV HT panel.the fault level setting of the fuse relay shall be as per the PSPCL norms so that individual will arrest trip/ activate to arrest the fault not travell to the PSPCL yard,The caliberation of the relay shall be carried out in the presence of AGE E/M in service of 11 KV switch gear damaged bus bar insulater should be change. cleaning the bus bar with Iso propyle alcohol scratching the rusted protion of bus bar panel then applying two coat of red oxide primer then painting with paint gun,varnishing the HT bus bar. Note:- (a) IR value of HT bus bar wrt earth and each phase wrt each other should not be less then 1.8 G ohm to 2.0 G ohm.(b) The equipments shall be tested twice, Ist test will be carried within two months from the date of commencement of contract and IInd test after six months from the first test. payment shall be released on receipt of results from PSPCL.
M&L for opening Dismantling tarnsformer capacity upto 750 KVA lifting the top cover for taking out the HT/LT core and draining out the transformer oil in clean barrel including cleaning the transfoemer chamber body inside and outside with emery paper aftre that checked all the winding and other wornout parts scuh as HT/LT coils silicon stamping and other connected items like tape changer, breaker assy, explosion tube with difram, connector tank etc and complete and reassembling the transformer LT/HT connection after proper dehydration , reconditioning and testing of transformer after reassembling complete on no load at work shop and on load testing at site and all as specified and diirected.Note: (i) job includes cost of gasket set, LT/HT bushes, nuts and bolts, washers etc required for the complete the Job.(ii) After refixing of transformer, testing of transformer will be based on partial load and full load, incl entire painting of transformer with super enamelled paint, deemed in quoted rates by contractor(iii) Unsv transformer should be rewinding in workshop within a week time frame on reaching at the work shop, after failing a penalty will be imposed to contractor as per IAFW-2249 of contract agreements(iv) transportation of transformer upto workshop and back to site will be complete responsibility to the contractor, and no other charges will be paid to contractor for transportation (v) Dehydration and filteration of transformer deemed in quoted rates.
M & L for replacement of winding of transformer / voltage stabilizer with appropriate gauge super enamelled copper wire for transformer/voltage stabilizer 25 KVA 750 KVA, 11 kv 3 phase complete all as specified and as directed. Note: With guarantee of 1 year from repairing date.
Supply and filling silica gel for bllue colour transformer any make, type and capacity complete all as specified and directed.
Note for item No 1 to 67:- (i) It is not mandatory to hand over the work site/ bldg to the Cotractor in one stretch. (ii) It may be handed over in peace-meal as and when the site/ bldg are vacated by the user including Sunday/ Holiday/ Night Hrs. Contractor shall make/ changes the execution plan accordingly. Any claim what so ever on this account shall not be admissible. (iii) Rate quoted by the Contractor shall be deemed to include on this account.
M/s Vee Kay Associates
Aman Enterprises
NARINDER KUMAR SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .