Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC A 2 206 SAI DWARKAMAI NIBM ROAD KONDHWA PUNE 411 048 | PUNE | MAHARASHTRA | 411048 | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹40.0 L+₹59,864.70 (1.52%)Rejected-AOC 54 10 SHANTI NAGAR NEAR SHINDE CHATRI WANAVADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L2 | Rejected-AOC Bidder not quoted L1 rates |
Tender Value
Refer Docs
EMD Value
₹86,100
Closing Date
4 Aug 2022, 6:00 pmClosed
GE SOUTH PUNE
NO 1 GENERAL BHAGAT MARG PUNE 411040
8353 SPECIAL REPAIRS TO ROOF AND TOILETS OF BLDG No. P-105 AND ADDN / ALTN / IMPROVEMENT TO EXISTING OTM COOK HOUSE (P-60) AT MINTSD AND PROVN OF SECURITY FENCING AROUND SURVEY No. 560 PARVATI VILLA UNDER GE SOUTH PUNE
2022_MES_536924_1
8353 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
183 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹86,100
17 Sept 2022
9 Jul 2022
6 Aug 2022
9 Jul 2022
4 Aug 2022
23 Jul 2022
Amount
M&L water proofing treatment to RCC roof slabs, walls, chajjas etc shall be carried out as specified below and as directed by Engineer-in-Charge. (a) Removing of old water proofing treatment including screed bed and cleaning the surface of slab with wire brushes removing dust, foreign materials including flushing at junction of wall and removing the rubbish off the premises to a distance exc 500m all as directed by Engr-in-Charge (b) M&L for 10mm thick plaster screed bed layer in CM 1:3 on concrete surfaces. (c) Preparing plastered surfaces of roof slab, walls, chajjas etc by brooming with broom sweeping free from dust etc and evenly applying a coat of approved bituminous primer @ 0.20 Kg/Sqm of area complete all as specified.
ITEM No. 1.00 Contd.... (d) Laying APP polymer modified approved membrane non woven, polyster weighing not less than 3.5 Kg/Sqm with laps and overlaps as specified and joints sealed and applied complete by torch application method all as specified and directed by Engineer-in-Charge. Carrying out test by flooding water for 24 hrs for leakage and seepage and rectifying the same to the entire satisfaction of GE. (e) Finally applying a coat of solar reflective bituminous aluminium @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkat with shutter without taking out shutter from the frame n.exc 1.5 Sqm complete all as specified and as directed.
Taking down chowkat with shutter without taking out shutter from the frame exc 1.5 and n.exc 4 Sqm each complete all as specified and as directed.
M&L for aluminium powder coated louvered ventilator with provision of exhaust fan using ‘Jindal” aluminium section including glass and stainless steel wire mesh etc complete all as specified and directed by Engineer-in-Charge. (a) SP 20048 (b) Glazing clips 19352
M & L for Double action Floor Spring Hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing poivet made of brass, other parts made of brass, other part made of mild steel heavy duty and fixed complete all as specified and as directed
S & F Solid PVC door frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with MS tube, supplying and fixing in opening complete all as per specification and as directed.
Supply and fix factory made solid Panel PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded Prelaminated PVC sheet on the front face and 2mm prelaminated colour PVC sheet on back face, fixed in frame at site as per specification and drawing including fittings complete all as specified and as directed.
S & F 100 mm butt hinges, excruded aluminium alloy type B-21 with galvanised mild steel ISI markedhinge pin, anodised and fixed with wooden screws complete as specified and directed.
S&F Aluminium anodised 150mm handle cast type, complete as specified and directed.
S&F aluminium anodised barrel tower bolt 200mm legth of excluded section and fixed complete all as specified and as directed.
S&F aluminium alloy sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section etc length of bolt 300 mm of ISI mark complete all as specified and directed
M&L for granite 18mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like in CM (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade incl taking down old stone slab of any description complete all as specified and as directed.
Rounding to edges of stone slab one edge, such as in steps, cooking platform and other similar situations complete all as specified and as directed.
M&L for 25 mm thk concrete type B0 1:2:4 using 12.50 mm graded agg as in floor leveling course etc. Incl demolition of old pcc of any description complete all as specified and directed.
M & L for coloured non skid ceramic tiles 300 x 300 mm 7 to 8mm thick in floor etc set & jointed in neat cement slurry and pointed in white or coloured cement to match fixed over and including screed bed or bedding layer 15mm thick in CM 1:6, incl taking down old tiles complete all as specified and directed .
Material and labour for coloured glazed ceramic tiles of size 300mm x 600mm x 7 to 8mm thick of colour and pattern as approved by EIC, as in vertical surface, set and jointed in neat cement slurry over and including 10mm thick backcoat in CM 1:4 using grey cement and pointed in coloured cement to match the colour of tiles over back coat incl taking down old tiles complete all as specified and as directed.
Disconnecting existing tanks of Cap exc 1000 ltr but n. exc 2000 ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in same/ other position complete all as specified and directed by Engr-in-Charge.
S&F rotational moulded polyethylene water storage tank of 2000 ltr capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I with 25 mm ball valve high pressure PTMT with rod & high density plastic ball incl dismantling of old water tank complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with Fly ash brick, straight or curved on plan exc 6M Mean radius built in type CM 1:6 incl demolition of old brickwork complete all as specified and directed by Engr-in-Charge.
Taking down cement or cement lime plaster on brick or stone wall etc. incl raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 10mm thick in cement mortar (1:6) on fair faces of brick/concrete surfaces with sagol finish complete all as specified and as directed
Rendering 10mm thick in CM 1:6, on brick/ PCC block walling, finished even & smooth without using extra cement complete all as specified and as directed.
Material and labour for 15 mm rendering in cement mortar (1:4) using water proofing compound @ 2 % by weight of cement in finish coat on other than fair faces of brick wall surfaces, sponge finish complete all as specified and as directed
M & L for 2mm thick wall care putty on wall complete all as specified and directed by Engr-in-Charge.
M & L for 2mm thick wall care putty on ceiling complete all as specified and directed by Engr-in-Charge.
M&L for Preparation of new plastered surfaces of wall and applying two coats of Exterior emulsion paint over a coat of primer all as specified and directed
M&L for Preparation of old painted surfaces of wall and applying two coats of Oil bound distemper complete all as specified and directed
M&L for Preparation of new plastered/putty surfaces of wall and applying two coats of Oil bound distemper over a coat of primer all as specified and directed
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal 15mm bore complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to edges or edges of landings, steps, cills etc and cutting chase for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10 cm girth in Brick walls complete all as specified and as directed
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal 20mm bore complete all as specified and as directed.
M&L for GI tubing 15mm dia medium grade with all fittings & fixed complete to walls & ceiling or laid in floors in repairs complete all as specified and as directed.
M & L for GI tubing 20 mm dia medium grade with all fitting & fixed complete to wall & Ceiling or laid in floor in repairs complete all as specified and as directed.
S&F in repairs vitreous china wash down water closet pan, 'Pedestal' coloured, including fixing bolts etc including PVC seat cover white with flat bottom including MS, CP or aluminium anodised hinges devices including PVC low level flushing cistern 10 Ltr capacity with all internal fitting, inlet, outlet pipe connections etc. complete all as specified and directed.
Supply and fix in repair 20mm bore Gun metal gate valve with iron wheel head, screwed both ends for iron pipes, complete all as specified and directed.
S&F high density 40mm bore polythylene pipes (HDPE) of pressure rating 6 kg/cm2 fixed complete to wall or in floors with necessary socket, elbow & bend etc complete all as complete and directed. (Note : pipe will be laid under floor)
S&F CP Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed.
Demolition and breaking up existing sewage/drain pipes ( Salt glazed ware ,AC or reinforced concrete ) set in cement mortar pipes and the like not exe 150 mm bore set in cement mortar and removing demolished material to a distance exc 50 m and n exc 100 m complete all as specified and as directed.
Supply and fixing PVC (SWR) pipe single socketed in any length with rubber ring joints laid in floor for 110mm bore of 6kgf/cm2 capacity complete all as specified and as directed.
All as per Ser. item No. 39.00 above but 75mm bore of 6kgf/cm2 capacity complete all as specified and as directed.
Supply and fixing PVC (SWR) pipe single socketed in any length with rubber ring jounts fixed to walls for 110mm bore of 6kgf/cm2 capacity complete all as specified and as directed.
All as per Ser. item No. 41.00 above but 75mm bore of 6kgf/cm2 capacity complete all as specified and as directed.
Supply and fixing PVC (SWR) junction single (singleT) equal or unequal nominal bore in mm joints fixed to walls for 110mm bore complete all as specified and as directed.
Supply and fixing PVC Bends any radius 110mm bore complete all as specified and as directed.
All as per Ser. item No. 44.00 above but 75mm bore complete all as specified and as directed.
Supply and fixing PVC vent cowl 110mm bore complete all as specified and as directed.
S&F 0.9mm thick Decorative laminate type 1, of surface finish, colour and pattern as approved, fixed with approved adhesive as per maker’s instructions complete all as specified and as directed
S&F 18mm thick Plywood, grade BWR, type BB, fixed with screws to timber framework complete all as specified and as directed.
S&F 2nd class hardwood Plain fillets,size exc 6 and nexc 13 sqcm in square, rectangular or triangular in section, clean sawn, secured with nails or brads complete all as specified and as directed
M & L for Water proofing treatment to sunken slab, walls, etc, shall be carried out as specified below and as directed by Engineer-in-Charge. (a) Clean the sunken portion of toilet/ Baths/ WCs/ Kitchen throughly remove laitance, dirt, dust etc. (b) Form angle fillet of size 40 mm x 40 mm along the junction of wall and floor using polymer modified mortar (“ Dr fixit” Pidicrete URP” or eqvt). (c) Sanitary pipes entering through walls and floor shall be sealed with “Dr Fixit Bathseal Tape” and the gaps to be grouted with non-shrink cementitous grout “Dr Fixit Bathseal Grout” or eqvt. Nahani traps etc to be fitted securely and the gaps around it to be grounted in the same manner. (d) Apply one coat of a Bitumen-modified polymer coating “Dr Fixit Bathseal Plus” or eqvt on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely.
ITEM NO. 50.00 Contd.... (e) In the remaining area, in dry substrate condition brush apply first coat of the same coating and further apply second coat when first is dry. Extend the coating upto 150mm above the FFI. Above FFI, another cementitious waterproofing waterproof coating “Dr Fixit Pidifin 2 K” or eqvt can be further applied right upto 2.1 m to waterproof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and pply second coat after 6-8 hoours and allow to dry completely. (f) After 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed 1:3:6 type B0 mixed with integral WPC (Liquid) laid to slope 1:60 towards outer face of wall. Provide 40 mm OD UPVC pipe at the lowest point with 300 mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2. (g) After completing plumbing work in the toilet/WC/Bath/Kitchen floor, tiling work (floor and dado) can be carried out using suitable Tile Adhesives and ready to make tile grouts of appd makes such as Dr Fixit, FOSROC SIKA, MC BUCHEMIE, ROFF, etc.
M & L for PCC 1:5:10 type E-2 (using 40mm graded brick aggregate) lean concrete for filling sunken floor complete all as specified and as directed.
Dismantling boarding/ceiling of any description, fixed in any position like partition etc with nails including frame work of timber complete all as specified and as directed.
S&F PVC false ceiling consisting of 595 X 595 mm , 5mm thick plain exposed PVC sheet of 600 kg/cbm density manufactured by an ISO certified company, used as panel inserted in a frame work made from anodised aluminium T-section of sizes 25X25mm 19 gauge or 1mm thick in square pattern of grid 600X600mm. The minimum frame work supported from the ceiling with 'J' hooks and GI wire/6mm MS rod of required size to maintain proper level etc. The aluminium frame work is supported on side wall with the use of alum 'L' section of 25X25mm angles etc complete all as specified and as directed (Make :M/s Rajshree/Armstrong/Syntex as approved by GE)
M&L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. (Note-1 : Design and pattern of ceiling shall be as approved by Engineer-in-Charge/ GE.)
S&F 8 mm thick seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous & calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling & tapping screws having Phillips head with under head cutter at 200 mm C/C including finishing the joint of face board with specially formulated jointing compound & 48 mm wide fibre tape to provide seam less finish ( Frame work for ceiling shall be measured & paid separately) complete all as specified and directed. (Note : Cost of making framework for light fittings/ grills/ diffusers and cutting to shape in ceiling etc shall be deemed to be included in the quoted rate of item.)
M&L for rendering 10 mm thick in cm 1:3 on fair faces of brick work or concrete surface in ceiling of roof, chajja and facia etc complete all as specified and as directed.
S & F Aluminium anodised Powder coating of ivory/ brown colour frame / shutters for windows/ doors/ Ventilator with one or more rebates including joining cleat, glazing clips,anodised aluminium snap beading for fixing, screws, anodised aluminium fittings such as peg stays, handle etc complete all as specified and directed.
Supply and fix 12mm thick Hinged Plain/ figured/ printed Toughened glass Door with all fittings such as CP Handle 900mm, Pivots etc complete all as specified and as directed. (Note : Design of glass/print as Approved by Engr-in-Charge)
S&F Stainless Steel Nahani trap Squarewith trap 6'' x 6'' with grating of diameter of outlet 75mm. Ruhe 304 Grade Stainless Steel Product Code : 16-0306-14 complete all as specified and as directed.
S&F Tall Pillar tap in polished chrome complete all as specified and directed. (Make : Kohler Product code K-23483IN-4-CP or equivalent model in Jaquar as approved by EIC)
S&F CP Pillar tap complete all as specified and directed. (Make : CERA Product code F1014101 or equivalent model in Hindware/Parryware as approved by EIC)
S&F Single piece-WC with PP Seat cover, hinges, Fixing Accessories, Accessories set and cistern fittings complete all as specified and as directed. (Make : Jaquar of cat no SLS-WHT-6851S110PP or equivalent model in Kohler as approved by GE. )
S&F in repairs Hand Shower( Health faucet) with 8mm dia, 1.2mtr flexible tube and wall hook with N.R.V. (back flow prevented) complete all as specified & directed. (Make : Jaquar Product code ALD-CHR-577or equivalent model in Kohler as approved by EIC).
S&F in repairs CP toilet paper holder confirming to CAT No ACN-WHM-1153S of "Jaquar" or Equivalent make here in after complete all as specified and as directed.
S & F in repairs double action floor spring hydraulically regulated made of minimum 1.25mm thick alloy sheet foundation box, with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty of approved make as per sample approved and directed by Engr-in-Charge.
S&F Soap dish holder confirming to CAT No 107120 of Kohler or Equivalent make in Jaquar complete all as specified and as directed.
S&F complementary square towel ring confirming to CAT No 25067IN-CP of Kohler or equivalent make in Jaquar complete all as specified and as directed.
S&F in repairs 2-Way Bib cock with Wall Flange complete all as specified & directed. Make : Jaquar Product code FLR-CHR-5041N or equivalent model in Kohler as approved by EIC
S&F in repairs Counter top basin of Size 575x410x171mm complete all as specified & directed. (Make : Kohler Product code K-5373IN-0 or equivalent model in Jaquar as approved by EIC)
S&F Bottle trap (with internal Partition) 32mm size with 250mm & 190mm Long wall connection pipes and wall flange complete all as specified & directed. (Make : Jaquar Product code ALM-WHM-769L250x190 or equivalent model in Kohler as approved by EIC)
M&L for Vitreous China urinals URS-WHT-132530 of Jaquar with fixing accessories complete including providing and fixing plus, bedding urinal against wall in cement mortar 1:2 securing urinal to plus with and including 60mm long brass screws, pointing around urinal back in cement; fixing auto closing concealed urinal flush valve PRS-CHR-073 of Jaquar, flush pipe, grating and Union for discharge pipe complete all as specified and as directed.
S&F in repairs, white, vitreous china urinal half stall type of first quality of approved make fixed in position including PVC waste pipe and coupling etc complete all as specified and directed.
S&F Urinal partition with frosted glass 8mm thick chrome finish of size 900 x 450mm of Jaquar Cat No JSE-CHR-110UC450X complete all as specified and as directed.
M&L for Preparation of new plastered/putty surfaces of ceiling and applying two coats of OBD over a coat of primer on ceiling all as specified and directed
M&L for Preparation of old painted surfaces of ceiling and applying two coats of OBD on ceiling all as specified and directed
Excavation in trenches n. exc. 1.50 mtr wide & n. ex. 1.50 mtr in depth for foundation not exc. 10 Sqm on plan and not exc. 1.50 mtr in depth and getting out in hard/dense soil complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (Using 40 mm graded stone aggrgate) as in mass concrete etc complete all as specified & directed.
M & L for brickwork with fly ash modular bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified & directed.
Returning, filling in hard/dense soil, including spreding, leveling, watering and well ramming in layers not exc 25 cm etc complete all as specified & directed.
Removing excavated material n. exc. 50 m and depositing where directed 50 m and upto a total distance of 250 m etc complete all as specified & directed.
M&L for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290. Gde-E-165 complete all as specified and directed
Taking down shutter from the frame exc 1 Sqm and n. exc 2 Sqm each complete all as specified and as directed.
S&F three track sliding window with two or more shutter with 4mm thick tinted glass one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing with good quality bearing handle, lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engr-in-Charge.(Make : Hindalco/Indal/Ajit India pvt ltd) (a) Bottom frame 20620 (b) Top frame & vertical 20621 (c) Handle (side) 20606 (d) Shutter inter lock 20724 (e) Shutter top & bottom 20844
S&F two track sliding window with two or more shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing with good quality bearing, handle, lock etc using following aluminum powder coated sections as given in 'JINDAL' Catalogue. (a) Bottom frame rail - 20619 (b) Top frame & Vertical - 20681 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844.
S & F pressed steel frames for doors with one or more rebates incl necessary hold fasts, hinges, lock strike plate etc complete as specified size of frame 105 x 60mm filled with PCC 1:3:6 type C-0 all as specified.
S & F 35 mm thick factory made second class hard wood, kiln seasoned and chemically pressure treated plain framed, panelled shutter (Two panels) with lock rail and panel of 9 mm BWP Commercial ply or 12 mm veneered particle board with commercial face veneers on both faces, complete as specified and directed.
S & F 35mm thick glazed and skeleton shutter open rebated and prepared to receive glass, gauge, etc. edges of framing plain,chamfered or rounded fitted with cut and mitred beads for securing glass, etc; The size of the rail and stile as per IS 1003 (Part-I), Kiln seasoned and chemically pressure treated with heritage elevation as specified and directed.
S&F Mild Steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
Supply and fixing 100 mm butt hinges medium weight cold rolled mild steel ISI marked fixed by welding to the pressed steel door frame as in repairs, complete as specified and directed.
Supply and fixing 150 mm aluminium anodised barrel tower bolts of extruded section, ISI marked and fixed with steel screws, complete as specified and directed.
S&F Aluminium powder coated single leaf door on pivots alongwith hydraulic door closer door lock , handle,5mm thick plane glass fixed with rubber beading in top panel and glazing clips MS clamps and 12mm th laminated particle board as bottom pannel both side laminated) using following sections as given in 'JINDAL' catlogue complete all as specified and as directed. (a) Rectangular tube - 14005 (b) Vertical rail - 19501 (c) Top rail -19503 (d) Middle rail -20060 (e) Bottom rail- 19511
Dismantling of stone slabs and tiles of any description or thickness in floor apron etc laid bedded and pointed in cement mortar complete all as specified.
Demolation of cement concrete (unreinforced) of any decreiption and in any position not otherwise specifically provided for
M&L for 25 mm thick plain cement concrete type B-1(1:2:4) ( 20 mm graded stone aggregate ) as in floors complete all as specified and directed.
S&F floor door stopper, aluminium alloy body and tongue anodised with hard drawn steel spring of 140mm size overall of ISI mark.complete all as specified and as directed.
M & L for hand cut kota stone slab flooring 18-20 mm thick, over 20 mm thick cement screed base in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shed of slab including rubbing and polishing complete including dismantling of old stone slabs and tiles of any description or thickness in floors, aprons laid, bedded and pointed in any mortar.
S & F Machine cut cuddappa stone 25 to 30 mm thick both side polished bedded & jointed in CM (1:3) complete all as specified and as directed.
M & L for coloured non skid ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but n.exc 0.38Sqm in floor etc set & jointed in neat cement slurry and poited in white or coloured cement to match fixed over and including screed bed or bedding layer 15mm thick in CM 1:6 all as specified and directed .
Demolition of stone / block masonry /brick masonsy built in CM complete all as specified and as directed.
Dismantling of Asbestos cement/galvalume (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed.
S&F roof sheeting prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Fixing only roof sheeting prepainted galvalume aluminium zinc coating GI based corrugated/plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified.
S&F roof sheeting prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified.
Dismantling of structural steel work including doors,gates but excluding framed Truss etc complete all as specified
M&L for MS structural steel work, framed as in trusses, purlins, rafter, post etc. conforming to grade E-250 (Fe-410W, quality A) including shaped washers including necessary cutting required length, notching drilling, riveting and or welding or connecting with nut bolts with angle cleats, fish plat, gusset plate and also erecting in true position complete as directed.
M & L for preparing new steel Surfaces of any description, over 10cm in width or girth, not otherwise described and applyig two coats of synthetic enamel paint over one coat of red oxide zink chrome primer complete all as specified.
M & L for preparation of new plastered surfaces of walls & applying two coats of weather shield acrylic latex paint which gives 5 year of performance warranty complete all as specified & directed. (Make : Burger/Nerolac/Asian paint)
M&L for Complete removal of existing treatment on walls/Stone masonary wall by scrapping washing rubbing down etc and applying two coats of Exterior emulsion paint over a coat of primer on stone masonry surface all as specified and directed
M&L for two coats synthetic enamelled painting over one coat of pink primer on new or previously untreated wooden surfaces of any descriptiion, not otherwise described over 10cm width or girth complete all as specified and as directed.
M&L for preparation of old wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed
Dismanting water tank of capacity n exc 1000 ltr and reomoving to store complete all as specified and as directed.
S&F rotational moulded polyethylene water storage tank 500 Litres capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I with 25 mm ball valve high pressure PTMT with rod & high density plastic ball complete all as specified and directed.
S&F rotational moulded polyethylene water storage tank of 1000 ltr capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I with 25 mm ball valve high pressure PTMT with rod & high density plastic ball complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base / flooring complete all as specified and as directed.
M&L for coloured precast cement concrete interlocking paver block of glossy finish any shape and size confirming to IS-15658-2006, 60mm thick, M-35 grade with grey cement and no pigment laid over & including 30mm thick stone dust/grit complete all as specified and as directed.
M&L for cement concrete type B1-1:2:4 (20 mm graded aggregate) in coping,coving,edging etc including necessary form work complete all as specified and directed.
Dismantling fencing wire mesh, any type complete all as specified and directed by EIC.
M&L for Cement concrete in foundations, filling and mass concrete.Type B2 1:2:4 using 40mm graded aggregate complete all as specified and directed by EIC.
M&L for reinforced cement concrete (nominal mix) Type B-1, 1:2:4 (20mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete. complete all as specified and directed by EIC.
M&L for reinforced cement concrete (nominal mix) Type B-1 1:2:4 (20mm graded aggregate) in Columns, pillars, piers, posts and struts complete all as specified and directed by EIC.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter. complete all as specified and directed by EIC.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. complete all as specified and directed by EIC.
All as per item No 124.00 above but MS round Bar complete all as specified and directed by EIC.
All as per Item No 124.00 above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by EIC.
M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way MS Gate, straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165
M&L for hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by EIC.
Supply only galvanised chain link fencing as specified and directed by engineer in charge.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed by EIC.
M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed by EIC.
Preparation of new plastered surfaces and applying two coats of cement base paint complete all as specified and as directed.
Taking down carefully exising unserviceable copper / aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed.
M & L for point wiring complete with and including single core PVC FRLS insulated unsheathed flexible bright annealed multi stranded copper conductor cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through and including heavy grade PVC rigid conduits 20 mm or higher dia as reqd at site, totally concealed in walls/floors/ceiling including all conduit accessories/fittings/junction boxes/ inspection covers etc; of heavy grade, ISI marked and sunken terminal boxes of factory made 16 SWG pressed steel housing, totally concealed in walls with 3 mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk/cupwashers, for mounting of switches, sockets fan regulatos etc; including 1.5 Sqmm (22/0.30 mm)1100 V grade FRLS,PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified, directed and shown for one light or fan point controlled by one 5A switch
All as per Ser. item No. 134.00 above but for One 5A 3 pin switch socket outlet on same board complete all as specified and as directed.
All as per Ser. Item No. 134.00 above but for One 5A 3 pin switch socket outlet mutipurpose on independent board.
All as per Ser. Item No. 134.00 above but wiring complete with 4.0 Sqmm for 3 pin 15 A socket multipurpose on independent board.
Supply anf fix switch piano flush button type 5 amps SP one way complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 Pin 5 Amp flush type 240 volts complete all as specified and as directed.
Supply anf fix switch socket combination 3 pin ,15/16 A flush type complete all as specified and as directed.
Supply anf fix switch socket combination 2 in 1,5 A flush type complete all as specified and as directed.
Supply and fix lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Material and labour for ceiling rose polycarbonate isolated body 3 ways terminals complete all as specified and as directed.
Supply and fix LED box type fitting pre-wired including LED tube 1x18/20W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable complete all as specified and as directed. (Make:- Havells or equivalent model of make Philips /GE/Crompton)
S&F in repairs recessed mounted LED luminaire 10Watt, 6000K with IP 65 Protection Model LHEOAOP7UZ6WO10 Make Havells or of equivalent make specified here-in-after complete all as specified and as directed.
Supply fix MCB DB of sheet metal enclosure double door SPN 8 way with 200 Amps rated bus bar 230 volt and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed.
S & F MCB SP 6- 32Amps, 240 V,50 HZ,C series breaking capacity 10KA all as specified and directed. (Make-Havells,Cat part No.-DHMGBSPF006-032 or of equivalent make specified here-in-after)
Supply and fix MCBs, SPN 40 to 63 Amps, 10 KA , IS/IEC 60898-12002 marked fixing in DBs (DBs catered separately in this Schedule) (Make:- Legrand/Havells/ Schnider)
S&F ventilating Exhaust fan 300mm sweep,230 volts PVC with blades and louvres fixing on wall complete with nut bolts incl duct for exhaust all as directed by engineer in charge.
S&F ventilating Exhaust fan 380mm sweep,230 volts metal frame with blades and louvres fixing on wall complete with nut bolts incl duct for exhaust all as directed by engineer in charge.
M&L for Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including galvanised earth lead wire 4 mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009
M & L for submain wiring complete with 2x4.0 Sqmm, 1100 volts grade, PVC insulated, unsheathed multi stranded copper conductor FRLS cable, 1100 volts, FR grade in PVC conduit of suitable size, including continuous PVC insulated copper earth wire 1x 4 Sqmm complete all as specified and as directed. [Note :- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 4 sqmm cable and 1 run of PVC casing caping shall be measured as one length.)
M & L for submain wiring complete with 2x6.0 Sqmm, 1100 volts grade, PVC insulated, unsheathed multi stranded copper conductor FRLS cable, 1100 volts, FR grade in PVC conduit of suitable size, including continuous PVC insulated copper earth wire 1x 6 Sqmm complete all as directed. [Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims.) (ii) 3 runs of 6 sqmm cable and 1 run of PVC conduit shall be measured as one length.]
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in soft/loose soil complete all as specified and as directed.
Removing excavated material to distance not exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and as directed.
Supply, laying, testing and commissioning of UG LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, cable lugs in LT panel/MCCB in bldg etc to suit the cable laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete of 16sqmm 4core
Supply and laying unreinforced precast concrete cover class LV type I, flat size 250mmx150mmx 40mm complete all as specified and as directed.
Supply and spreading fine crushed stone sand for cushioning to LT / HT UG cable including spreading, levelling and hand punning etc. complete all as specified and directed. (Note : The punned thickness shall only be measured for payment.)
Supply and lay pipe galvanised light grade incl fittings 40mm in trenches,wall and pole all as specified and directed
S&F vertical 4 way TPN double door, recess mounted / wall mounted, MCCBs as incomer is 3 pole V-Tec of 100A rating & 16KA breaking capacity,MCCB is pre-fitted at factory & including price of MCCB,all as directed and specified
M & L for submain wiring complete with 4x6.0 Sqmm, 1100 volts grade, PVC insulated, unsheathed multi stranded copper conductor FRLS cable, 1100 volts, FR grade in PVC conduit of suitable size, including continuous PVC insulated copper earth wire 2x 6.0 Sqmm complete all as specified and as directed. [Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 6 runs of 6 sqmm cable and 1 run of PVC conduit shall be measured as one length.]
Supply, fixing and testing LED IP 66 roadway luminarie with suitable size bracket high power LED as light source and electronic driver for 35 Watt LED efficacy 100 lumens/watt CCT 5700K,CRI>70 PF 0.95,IP66,IK 07 SP5KV interval , complete all as specified and directed.
M/s.BAJRANG CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .