Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹54.5 L+₹4.7 L (9.48%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹54.7 L+₹4.9 L (9.91%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹54.8 L+₹5.1 L (10.2%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹55.2 L+₹5.4 L (10.8%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹91,705
Closing Date
4 Nov 2023, 6:00 pmClosed
GE (AF) JORHAT
JORHAT
PROVISION OF VOLTAGE STABILIZER, REGULATOR AND TRANSFORMER ALONGWITH ASSOCIATED WORK SERVICES AT CERTAIN TECHNICAL LOCATIONS AND REPLACEMENT OF GEYSER AGAINST BER AT AFS UNDER GE (AF) JORHAT
2023_MES_623199_1
8582/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
GE (AF) JORHAT
Please Refer Tender Document
9 documents required · 9 mandatory
₹500
Yes
GE (AF) JORHAT
₹91,705
Yes
21 Dec 2023
14 Oct 2023
6 Nov 2023
14 Oct 2023
4 Nov 2023
28 Oct 2023
Amount
Supply, fixing, commissioning and testing automatic voltage stablilizer, out door type AC 100 KVA servo controlled oil cooled, 3 phase, 50 Hz. in oil cooled construction with first filling of oil, suitable for unbalanced input and unbalanced load, for outdoor use in maximum ambient temperature of 45°C with bypass arrangement PCC for foundation as per OEM recommendation complete all as specified and as directed. NOTE : (a) Input : 300-480V, 3phase, 4 wire, 50Hz, AC Output : Voltage stabilized at 380 volt, ±2.5% 3 phase, 50Hz, AC Speed of correction : 8volt/sec Protection : U/V, O/V, O/L protection O/P MCCB. (b) Necessary PCC foundation shall be measured and paid separately.
Supply and fixing 100 KVA Isolation transformer, outdoor type, three phase, 50 Hz, AC Air cooled, Double Wound, Dry Type Varnish impregnated Isolation Transformer with enclosure and first full filing of oil suitable for outdoor use in maximum ambient temperature of 45°C confirming to IS : 2026 and IS : 111271, PCC for foundation as per OEM recommendation complete all as specified and as directed. Primary : 415 V, 3 Phase, 50 Hz AZ Secondary : 415 Volt AC 3 Phase, 50 Hz Connection : Delta- Star. Vector Group : Dyn 11 Insulation : Class ‘B’ NOTE : Necessary PCC foundation shall be measured and paid separately.
Supply, fixing, commissioning and testing automatic voltage stabilizer, out door type, AC 200 KVA servo controlled oil cooled for, 3 phase, 50 Hz. In oil cooled construction with first filling of oil, suitable for unbalanced input and unbalanced load, for outdoor use in maximum ambient temperature of 45°C with bypass arrangement complete all as specified and as directed. NOTE : Input : 300-480V, 3phase, 4 wire, 50Hz, AC Output : Voltage stabilized at 380 volt, ±2.5% 3 phase, 50Hz, AC Speed of correction : 8 volt/sec Protection : U/V, O/V, O/L protection O/P MCCB.
Supply and fixing 20 KVA Isolation transformer, outdoor type, three phase, 50Hz, AC Air cooled, Double Wound, Dry Type Varnish impregnated Isolation Transformer with enclosure and first full filing of oil suitable for outdoor use in maximum ambient temperature of 45°C confirming to IS 2026 and IS 11171, PCC foundation as per OEM recommendation complete all as specified and as directed. Primary : 415 V, 3 Phase, 50 Hz AZ Secondary : 415 Volt AC 3 Phase, 50 Hz Connection : Delta- Star. Vector Group : Dyn 11 Insulation : Class ‘B’ NOTE : Necessary PCC foundation shall be measured and paid separately.
Supply, fixing, commissioning and testing automatic voltage stabilizer out door type AC 20 KVA servocontrolled oil cooled for, 3 phase, 50Hz. In oil cooled construction with first filling of oil, suitable for unbalanced input and unbalanced load, for outdoor use in maximum ambient temperature of 45°C with bypass arrangement complete all as specified and as directed. NOTE : Input : 300-480V, 3phase, 4 wire, 50Hz, AC Output : Voltage stabilized at 380 volt, ±2.5% 3 phase, 50Hz, AC Speed of correction : 8volt/sec Protection : U/V, O/V, O/L protection O/P MCCB.
Supply, fix, commissioning and testing out door type AC 40 KVA servo controlled oil cooled for automatic voltage stabilizer, 3 phase, 50Hz. In oil cooled construction with first filling of oil, suitable for unbalanced input and unbalanced load, for outdoor use in maximum ambient temperature of 45°C with bypass arrangement complete all as specified and as directed. NOTE : Input : 300-480V, 3phase, 4 wire, 50Hz, AC Output : Voltage stabilized at 380 volt, ±2.5% 3 phase, 50Hz, AC Speed of correction : 8volt/sec Protection : U/V, O/V, O/L protection O/P MCCB.
M&L for earthing with copper plate electrode of size 600mm x 600mm x 3mm thick burried directly in ground vertically to a depth of not less than 2.25m below ground level connected to copper strip 20 x 3mm as earthing lead means of nuts, bolts and washers made out of galvanised iron mild steel and 32mm dia GI pipe "medium grade" for protection of earth lead and connected to test point or as directed including Pit in plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) and RCC Cover of size 450x450x50mm in RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with and including 8.0mm dia TMT bars @ 100mm centre to centre both ways, galvanised Iron wire mesh, funnel, galvanised iron watering pipe 20mm bore, medium grade, including necessary excavation and earth work in soft/ loose soil, returning, filling in and removal of surplus soil upto a distance of 50m and all as shown in Electrical Plate No. 5 of MES Schedule Part-I and testing on completion complete all as specified and as directed.
M&L for earthing with galvanised mild steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically to a depth of not less than 2.25m below ground level connected to galvanise iron strip 32 x 6mm as earthing lead means of nuts, bolts and washers made out of galvanised iron mild steel and 40mm dia GI pipe "light grade" for protection of earth lead and connected to test point or as directed including pit in plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) and RCC Cover of size 450x450x50mm in RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with and including 8.0mm dia TMT bars @ 100mm centre to centre both ways, galvanised iron wire mesh, funnel, galvanised Iron watering pipe 20mm bore medium grade, including necessary excavation and earth work in soft/loose soil, returning, filling in and removal of surplus soil upto a distance of 50m and all as shown in Electrical Plate No. 5 of MES Schedule Part-I and testing on completion complete all as specified and as directed.
S&F of cubical housing LT panel outdoor type, of adequate size, platform mounted factory made, totally enclosed dust and vermin proof openable form both front and rear side made out of 14 SWG (3.15mm) thick CRCA MS sheet and built up suitable size angle iron frame work having front and rear hinged doors, GI earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply powder coated paint (RAL-7032). The panel should be suitable for 415 volts, 50 Hz, 3 Phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work in plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) and comprising following :-
BUS BAR CHAMBER : Copper bus bar 200 Amps - 04 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (Red, Yellow, Blue) for three phases and black for neutral. INCOMMER : MCCB 160 Amp, 415 volt, Thermal Magnetic, 35 KA breaking capacity duly connected to bus bar as incoming – 01 No. OUT GOING FEEDERS :- (a) MCCB 160 Amps, 415 volt, thermal magnetic, 35 KA breaking capacity duly connected to bus as incoming – 01 No. (b) MCCB 40 Amps, 415 Volt, 16 KA breaking capacity 4 pole duly connected to bus bar as outgoing – 02 Nos. INDICATING DEVICES (a) Digital multifunction meter, model C, Class 1 with relay – 01 No. Make : L&T/ABB/HPL with suitable CT and wiring. (b) Three indication lamp neon type for three phase.
S&F of cubical housing LT panel outdoor type, of adequate size, platform mounted factory made, totally enclosed dust and vermin proof openable form both front and rear side made out of 14 SWG (3.15mm) thick CRCA MS sheet and built up suitable size angle iron frame work having front and rear hinged doors, GI earting strips at rear side, bottom detachable gland plate complete with suitable size zine plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply powder coated paint (RAL-7032). The panel should be suitable for 415 volts, 50 Hz, 3 Phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising with the followings :-
BUS BAR CHAMBER : Copper bus bar 400 Amps - 04 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (Red, Yellow, Blue) for three phases and black for neutral. INCOMMER : MCCB 200 Amp, 415 volt, Thermal Magnetic, 35 KA breaking capacity duly connected to bus bar as incoming - 01 No. OUT GOING FEEDERS : (a) MCCB 160 Amps, 415 volt, thermal magnetic, 35 KA breaking capacity duly connected to bus as incoming – 01 No. (b) MCCB 40 Amps, 415 Volt, 16 KA breaking capacity 4 pole duly connected to bus bar as outgoing – 02 Nos. INDICATING DEVICES. (a) Digital multifunction meter, model 'C', Class 1 with relay-01 No. Make : L&T/ABB/HPL with suitable CT and wiring. (b) Three indication lamp neon type for three phase.
M&L for PCC (1:2:4) type B-2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete for servo voltage stabilizer and isolation transformer plinth complete all as specified and as directed.
S&F GI pipe 80mm bore (dia) ‘Light grade’ for protection of UG cable, laid in floors/road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc. complete all as specified and as directed.
Excavation in trenches not exc. 1.5m wide and 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 250mm in soft/loose soil complete all as specified and as directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed.
M&L for XLPE insulated cable, heavy duty in trenches/passing through pipe/on wall, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor 1100 volts grade, cross sectional area 95 sq.mm of 3.5 core complete all as specified and as directed. NOTE : Rate of the saddle and clamps for fixing of cable on walls are inclusive with the quoted rate.
All as per Serial item No. 16 here-in-before but of size 120 sq.mm 3.5 core.
All as per Serial item No. 16 here-in-before but of size 50 sq.mm 3.5 core.
All as per Serial item No. 16 here-in-before but of size 35 sq.mm 3.5 core.
M&L for sand cushioning (dry sand) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness complete all as specified and as directed. NOTE: For the purpose of payment, punned thickness of sand cushioning only shall be measured and paid for.
S&F sub-class 'B' bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection complete all as specified and as directed.
M&L for submain wiring comprising 4 runs of single core 6 sq.mm FRLS PVC insulated copper cable 1100 volts grade multistrand, unsheathed conductor drawn into PVC casing and capping and all necessary fittings including 2x6 sq.mm multi strand FRLS PVC insulated copper wire for earth continuity conductor connected to common earth wire complete all as specified and as directed. NOTE:- Extra length of cables/wire required for connection to MCBs/DBs shall not be measured and the rate quoted by the contractor for per unit shall be deemed to be inclusive accordingly.
M&L for submain wiring comprising 2 runs of single core 6 sqmm FRLS PVC insulated copper cable 1100 volts grade multistrand, unsheathed conductor drawn into PVC casing and capping and all necessary fittings including 1x4 sqmm multi strand FRLS PVC insulated copper wire for earth continuity conductor connected to common earth wire complete all as specified and as directed. NOTE:- Extra length of cables/wire required for connection to MCBs/DBs shall not be measured and the rate quoted by the contractor for per unit shall be deemed to be inclusive accordingly.
S&F as in repairs sheet metal enclosure TP&N DBs, double door, 240 volts, 4 way complete all as specified and as directed.
S&F as in repairs 415 volt, 10KA ‘C’ curve miniature circuit breaker (MCB) of TPN 40 to 100 Amp and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
S&F as in repairs for MCB single pole & neutral, 240 volts 32 Amps ‘C’ curve complete all as specified and as directed.
S&F as in repairs VTPN DB, 415 volt, 4 way, 100 Amp Bus Bar with metal door having facility for MCCB incoming up to 250A and MCB outgoing complete all as specified and directed. Make: L&T, Cat No. DBVTH004DD or equivalent model from make as specified in Particular Specifications.
S&F as in repairs MCCBs 160 Amps current capacity, 415V,36 KA, 4 Pole, thermal magnetic type, along with spreader terminals complete all as specified and as directed.
S&F and testing XLPE insulated cable, screened PVC bedded, galvanised steel strip or wire un armoured electric power cables 1100 volts grade with stranded copper conductor of size 35 Sq.mm single core complete all as specified and as directed
Supply and installing Geyser 25 litrers capacity suitable to operate in single phase AC supply 230 volts, 50 Hz, EER 5 star rating, and heating element upto 2 KW including provision of grouting of suitable size nut bolts with supports of MS/wooden frame to support Geyser including PVC pipe hot and cold complete all as specified and as directed.
S&F 15mm bore Gl pipe, medium grade, laid in walls and ceilings or laid in floor including necessary fittings/fixture like tee, bend. socket, union, nipple, etc. and necessary connections complete all as specified and as directed.
Supply and draw submain wiring with two runs of single core 4 sq.mm FR PVC insulated copper cable 1100 volts grade multistrand, unsheathed conductor drawn into PVC casing and caping and all necessary fittings including 4 sq.mm multi strand FR PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete all as specified and as directed.
M&L for sheet metal enclosures with plug top and MCBS single pole and natural enclosures with two pin and earth plug and socket complete with one single pole MCB 32 Amps capacity complete all as specified and as directed.
S&F 15mm angular stop cock with cast flange chromium plated complete all as specified and as directed.
S&F 15mm bore long body bib cock with cast flange chromium plated all complete as directed.
M/S BARUAH ELECTRICALS
NIHAR ENTERPRISE
M/S BARUA REFRIGERATION WORKS
M/S SANTOSHI TRADERS
M/S PAUL CONSTRUCTION
SHRI RAJEN PASWAN
M/S DILIP GOSWAMI
Bidder Name
NIHAR ENTERPRISE
M/S BARUA REFRIGERATION WORKS
THE SUPPLY AGENCY
SHRI RAJEN PASWAN
M/S PAUL CONSTRUCTION
M/S SANTOSHI TRADERS
M/S DILIP GOSWAMI
M/S BARUAH ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .