| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹1.5 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.6 Cr+₹8.0 L (5.41%)Rejected-Finance FLAT NO 1 PLOT NO 54 GRD FLOOR TULSI ASTHA NEAR SHRI ANAND RUSHIUDYAN SECTOR 12 VASHI NAVI MUMBAI 400 703 | THANE | MAHARASHTRA | 400703 | ₹1.6 Cr+₹8.0 L (5.41%) | L2 | Rejected-Finance Not L1 |
| 3 | L3₹1.8 Cr+₹33.4 L (22.5%)Rejected-Finance ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | ₹1.8 Cr+₹33.4 L (22.5%) | L3 | Rejected-Finance Not L1 |
| Sl No | Description | Qty | Unit | M/s Shreeji Construction Co L2 | M/s Shree Construction Co L1 | mp construction co L3 |
|---|---|---|---|---|---|---|
| 1.00 | SCHEDULE A PART-I : BLDG WORK
Surface Excavation not exceeding 30 cm deep and average n.exc 15cm depth in any type of soil to get the formation uniform level including dressing, watering and well ramming / rolling in requisite size and shape.
Note : Before commencement of the work, the initial level with total station shall be carried out by the contractor with consultation with the Engr-in-Charge/JE wrt decided bench mark and After completing the earthwork, the final level shall be submitted alongwith calculation details in Simson’s rule by the contractor which shall be checked by EIC/JE before carrying out the payment. The rate quoted deemed to be included. No extra payment shall be made separately on this account. All work shall be executed based on Arch & Str drg which are enclosed with tender documents. | 575 | Sqm | 90 ₹51,750 | 90 ₹51,750 | 50 ₹28,750 Lowest |
| 2.00 | Excavation over areas, n exc 1.5m deep and getting out in any type of soil to get the formation uniform level including dressing, watering and well ramming / rolling in requisite size and shape.
Note : Before commencement of the work, the initial level with total station shall be carried out by the contractor with consultation with the Engr-in-Charge/JE wrt decided bench mark and After completing the earthwork, the final level shall be submitted alongwith calculation details in Simson’s rule by the contractor which shall be checked by EIC/JE before carrying out the payment. The rate quoted deemed to be included. No extra payment shall be made separately on this account.All work shall be executed based on Arch & Str drg which are enclosed with tender documents. | 170 | Cum | 120 ₹20,400 | 120 ₹20,400 | 40 ₹6,800 Lowest |
| 3.00 | Excaution in trenches by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. on plan and n ecx 1.5 m in depth and getting out hard/dense soil. | 180 | Cum | 125 ₹22,500 Lowest | 125 ₹22,500 Lowest | 300 ₹54,000 |
| 4.00 | M&L for PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in foundation, filling and mass concrete. | 10.25 | Cum | 4,000 ₹41,000 | 4,000 ₹41,000 | 3,000 ₹30,750 Lowest |
| 5.00 | M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and matt beams sides and soffits (if any) of foundation and plinth beams; and similar work ; vertical or to batter ,flat | 135 | Sqm | 290 ₹39,150 Lowest | 290 ₹39,150 Lowest | 300 ₹40,500 |
| 6.00 | M&L Forrnwork to sides of pillars. posts. struts. piers. columns and stan- rchions for fair finished surfaces of concrete,square, | 335 | Sqm | 310 ₹1,03,850 | 310 ₹1,03,850 | 300 ₹1,00,500 Lowest |
| 7.00 | Use and waste formwork to sides and soffits of floor or roof beam. beam hauchings. girders. bressum-mers.· lintels. cantilevers. shelves including supports. overhangs. etc. also splays between floors and beams. etc.. for flat | 665 | Sqm | 300 ₹1,99,500 | 250 ₹1,66,250 Lowest | 300 ₹1,99,500 |
| 8.00 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) | 330 | Sqm | 350 ₹1,15,500 | 280 ₹92,400 Lowest | 500 ₹1,65,000 |
| 9.00 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm with rough finished surface | 95 | RM | 100 ₹9,500 | 80 ₹7,600 Lowest | 200 ₹19,000 |
| 10.00 | M/L for RCC M30 (Design mix) in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns,etc.; basement slabs,under-reamed piles and mass concrete. Note : All the work shall be executed based on Arch and Str drg which are enclosed with tender documents. | 52 | Cum | 9,500 ₹4,94,000 | 9,000 ₹4,68,000 Lowest | 11,000 ₹5,72,000 |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
30 Jul 2025, 6:00 pmClosed
GE NW Mankhurd
GE NW Mankhurd MUMBAI-88
PROVISION OF COMMUNICATION EQUIPMENT STORE AT TS MAHUL UNDER GE (NW) MANKHURD
2025_MES_718849_1
8417/E8
Open Tender
Civil Works
Item Rate
300 days
GE NW Mankhurd
As per Tender Documents
8 documents required · 8 mandatory
₹1,000
GE NW Mankhurd
₹2.1 L
19 Sept 2025
7 Jul 2025
1 Aug 2025
7 Jul 2025
30 Jul 2025
16 Jul 2025
Amount
SCHEDULE A PART-I : BLDG WORK Surface Excavation not exceeding 30 cm deep and average n.exc 15cm depth in any type of soil to get the formation uniform level including dressing, watering and well ramming / rolling in requisite size and shape. Note : Before commencement of the work, the initial level with total station shall be carried out by the contractor with consultation with the Engr-in-Charge/JE wrt decided bench mark and After completing the earthwork, the final level shall be submitted alongwith calculation details in Simson’s rule by the contractor which shall be checked by EIC/JE before carrying out the payment. The rate quoted deemed to be included. No extra payment shall be made separately on this account. All work shall be executed based on Arch & Str drg which are enclosed with tender documents.
Excavation over areas, n exc 1.5m deep and getting out in any type of soil to get the formation uniform level including dressing, watering and well ramming / rolling in requisite size and shape. Note : Before commencement of the work, the initial level with total station shall be carried out by the contractor with consultation with the Engr-in-Charge/JE wrt decided bench mark and After completing the earthwork, the final level shall be submitted alongwith calculation details in Simson’s rule by the contractor which shall be checked by EIC/JE before carrying out the payment. The rate quoted deemed to be included. No extra payment shall be made separately on this account.All work shall be executed based on Arch & Str drg which are enclosed with tender documents.
Excaution in trenches by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. on plan and n ecx 1.5 m in depth and getting out hard/dense soil.
M&L for PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in foundation, filling and mass concrete.
M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and matt beams sides and soffits (if any) of foundation and plinth beams; and similar work ; vertical or to batter ,flat
M&L Forrnwork to sides of pillars. posts. struts. piers. columns and stan- rchions for fair finished surfaces of concrete,square,
Use and waste formwork to sides and soffits of floor or roof beam. beam hauchings. girders. bressum-mers.· lintels. cantilevers. shelves including supports. overhangs. etc. also splays between floors and beams. etc.. for flat
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm with rough finished surface
M/L for RCC M30 (Design mix) in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns,etc.; basement slabs,under-reamed piles and mass concrete. Note : All the work shall be executed based on Arch and Str drg which are enclosed with tender documents.
M/L for RCC M30 (Design mix) in columns, pillars, plers.posts and struts. Note : All the work shall be executed based on Arch and Str drg which are enclosed with tender documents.
M/L for RCC M30 (Design mix) in beams, cantilevers, bressurnmers lintels over 1.5m span. Note : All the work shall be executed based on Arch and Str drg which are enclosed with tender documents.
M/L for RCC M30 (Design mix) in Chajjas, complete all as specified. Note : All the work shall be executed based on Arch and Str drg which are enclosed with tender documents.
M/L for RCC M30 (Design mix) Slabs supported on walls, beams and columns in floors, roofs,landings, balconies, canopies, deck slabs and in shelves and the like. Note : All the work shall be executed based on Arch and Str drg which are enclosed with tender documents.
M&L Pre-cast cement concrete block masonry Type B1 1:2:4 (20 mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in mortar, complete set in CM 1:6
M&L CRS TMT FE 500D bars 10 mm and over cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality confirming to all as specified. Note : All the work shall be executed based on Arch and Str drg which are enclosed with tender documents.
Description same as per item above but, 5 mm dia and over and incl 10mm dia in stirrups, spacers and binders. Note : All the work shall be executed based on Arch and Str drg which are enclosed with tender documents.
M&L hard core of gauge exc 63mm but not exc 100 mm depoted ,spread and levelled in layers not exc 15 cm thick watered and rammed to a true surface broken stone or boulders
M&L for 100mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in sub base
M&L 40mm thick PCC 1:2:4 type B1 using 20mm graded stone agg laid in panel finished even & smooth with using extra cement as in flooring complete all as specified and as directed.
M&L 75 mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate laid in panels surface finish even and smooth without using extra cement as in plinth protection including cutting of requisite construction/dummy joint with filling materials of bitumen grade A.
M&L for ATT for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area
M&L for ATT for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured)
M&L for ATT for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface
M&L for ATT for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
M&L for ATT for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall
M&L for rendering 10mm thick on fair faces of brick work or concrete surface in CM 1:6 and rendering is to be finish even and smooth with out using extra cement.
M&L for randering 15 mm thick on other than fair faces of brick work or concrete surface in CM 1:4 and rendering is to be finish.
M&L for 5mm thick rendering on concrete surface of ceiling in CM 1:3and rendering is to be finished even and smooth with out using extra cement
M & L three coats of white wash on newly plastered ceiling surfaces including preparation of surfaces.
M & L for preparation of newly plastered surface and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M&L two coat of oil bound distemper over a coat of primer & 3mm thick in two layer wall putty on newly plastered wall surfaces including preparation of surfaces
M & L for colored vitrified double charged (600x600)x 9 - 10 mm th. in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM 1:6
M&L for glazed ceramic colored tiles in vertical surfaces of size 600x300x 6 to 7mm thick set and jointed in neat cement slurry and pointed in coloured cement as in vertical surfaces such as dado/skirting and facea of side bldg over & including 10mm thick rendering in CM(1:4) complete all as specified and as directed.
Non-skid Coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer 15mm thick for laying floor finishes in cement mortar 1:6 to receive tiles/stone slabs complete all as specified and directed by EIC.
Non-skid Coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer 10mm thick for laying floor finishes in cement mortar 1:6 to recive tiles/stone slabs including skirting with backing coat complete all as specified and directed by EIC.
Supply and fixing of aluminum anodised powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified, including powder coating of minimum 50 micron thickness
Supply and fixing of aluminum anodised powder coated window and ventiltor shutters, fixed/sliding type without sash bar, aluminium section weighin0.55 kg/m including necessary joining cleat glazing clips, rubber packing, anodised aluminium snap beading screw etc. complete all as specified including powder coating of minimum 50 micron thickness
S & F 4.8mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.50 Sqm in each panes.
S & F 12mm pre-laminated particle board interior grade prelaminated both side with decorative choice lamination fixed with screws to timber frame work as in shutter of cup board and other similar work
S&F 18mm thick celuka PVC sheet minimum 600 kh/cum density grade 1 quality of both side plain white colour regidlam glossy finish fixed with screws, solvent cement/adhesive as per manufacturer instructions to make kitchen cabinet side top and bottom and shelves inside the cabinet complete as per specifications and as directed by Engineer-in-Charge. Note :- (i) Cub board accessories ie fiffints, handles, hinges will be measured and paid under this schedule. (ii) Quoted rates deem to be include fixing of cabinet on wall with appropriate rawl plug/dash through fastener (hammer type). (iii) Fabrication and installation of cabinet to be carried out by authorised vendor of manufacture only
M & L second class hardwood plain, soild, straight, chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints all as specified and as directed.
S & F flush door shutter of thickness 35mm with particle board core covered with decorative in both faces with veener with lipping all s per direction of Engr in Charge.
S & F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, suppling & fixing in opening as per specification & drawing
S & F for factory made solid PVC panel type PVC door shutter 30mm thick consisting of frame madeout of MS tubes for top and bottom rails MS frame shall be covered with moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet fot top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and as directed.
S & F 5mm PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing.
S&F Solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing.
S&F for 100mm dia grating doom with waste hole of PTMT (Minimum weight 25 gms)
S&F aluminium extruded Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete
S&F vitreous China wash basin white, flat back size 550 x 400mm including 15mm dia fancy type pillar tap of Make ESSCO Model no DLX-507KN or equivalent of make Parko as approved by the GE, , chromium plated CP waste coupling, chain and plug, waste fitting, union and waste pipe 32mm dia of required length and all necessary 450mm long outlet and inlet PVC connections pipes with PTMT check nuts complete. Make-(Jaquar, Cera, Hindware)
S&F vitreous coloured China Europeon water closet (Pedestal Pattern) including 10 ltr capacity low level flushing cistern with necessary PVC connections 15mm size with PTMT nuts of length 450mm long etc complete. Make-(Jaquar, Cera, Hindware)
Supply only 32mm dia waste coupling of PTMT (half or full thread) min wt 40gms
S & F pillar taps cast alloy with capasten head screwed down high pressure with without lettered 'Hot' or Cold with long screwed shanks and fly-nuts screwed for iron pipe and fixed Make-(Jaquar, Cera, Hindware)
S&F 600mmx450mm bevelled edges mirror consisting of 5.5mm thick commercial plywood and fixed to plug with chromium plated brass screwed and cup washer
S & F bib taps 15mm bore cast copper alloy with crutch or butterfly, handle, screwed down, screwed for iron pipe. Make-(Jaquar, Cera, Hindware)
S & F stop valve15mm bore cast copper alloy with screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions complete. Make-(Jaquar, Cera, Hindware)
S & F stop valve15mm bore cast copper alloy fancy type chromonium plated with long shank and cup(concealed type) screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions. Make-(Jaquar, Cera, Hindware)
S & F Brass CP mixer 20mm for mixing hot & cold water screwed down for iron pipe and fixed. Make-(Jaquar, Cera, Hindware)
S&F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm
S&F PVC connection 15mm bore length not less than 450 mm long with both ends PTMT nuts complete all as specified.
S&F tubular towel rail brass chromium plated, 20mm dia, D type 60 cm long between flanges.
S&F 75 mm dia PVC (SWR) floor trap plain with greting incl jointing with solvent cement
S&F 75 mm bore PVC (SWR) pipes of single socketed in any length with rubber ring joints laid in trenches or in floors all as specified
S&F 75 mm bore PVC (SWR) pipes of single socketed in any length with rubber ring joints fixed to wall all as specified
S&F 75 mm bore. PVC (SWR) bends
S&F uPVC vent cowl 110mm bore with and including rubber ring joints, complete all as specified and directed.
S&F uPVC vent cowl 75 mm bore with and including rubber ring joints, complete all as specified and directed.
M&L for PVC (SWR) pipes fixed in single socketed in any length with rubber ring joints fixed to walls and laid in trenches or floors 110 dia.
M&L for PVC (SWR) bends fixed in any radius of 110mm dia
M&L Granite (of galexy pattern) Tiles 18-20mm thick in floor machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 20mm thick CM 1:6 screed bed for laying floor finishes and cutting and polishing complete all as specified and as directed
S&F Anodised aluminium snap grid frame work for false ceiling all as specified fixed using Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
Providing and fixing modular/decorative type Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions
S&F for Aluminium wall cladding of size 6mm thick, Aluminium size (1250mm x 2440mm x 4mm th) of mirror finish, one or both side unbroken polyethylene, anodised coating etc. all as specified and as directed by Engr-in-Charge.
Supply only integral water proofing compound
M&L Water proofing treatment on RCC roof etc. comprising with the following operation & as specified herein below:- (a) M & L screed bed and bedding layer of Mortar 20mm thick in CM 1: 4 for roof slab mixed with water proofing compound (to be measured and paid separately) as per manufactures instruction finished even and plain complete (b) Preparing & cleaning of fully dried cement concrete surface. (c) Applying one coat of hot bituminous primer to the plastered surface @ 0.25 litres per sqm conforming IS-3384. (d) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction.
S&F rotational moulded polyethylene water storage tank consisting of three laver cylindrical vertical with top closed hoisted and fixed in position all as specified and directed capacity 1000 ltrs.
Supplying and laying 16mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/walls/ floor complete all as specified
Supplying and laying 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/walls/floors complete all as specified
S&F 25 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe
S&F 25 mm dia Ball valves ,high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule
Cutting chase, pinning in making good to faceing where required and pointing in cement mortar 1:3 to ends or edges of landing, and cutting chase for concealed water tubing or concealed conduit wiring etc and making good cutting exc 10cm but n exc 20cm.
S & F galvanised SS wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete.
S & F 150 mm size Aluminium handles, cast type, anodised.
S&F, 200 mm long aluminium anodised barrel barrel tower bolts of extruded section and fixed as specified and as directed.
Removing excavated material n exc 50m and depoting where directed at a level n exc 1.5m above the starting point.
Returning filling including spreading, levelling, watering and well ramming under floor in layers n exc. 25cm
Forming embankments including raising (or lowering) earth, spreading in layers not exceeding 30 cm thick watering, ramming /rolling and finishing to required size, shape, etc, n exc 1.5m high from base where compaction of earth filling is ordered to be carried out under optimum moisture conditions. Note: Excavated soil is used for filling
Bringing out of approved earth incl rough excavation upto requisite depth and returning filling under the floor (as approved by Garrison Engineer) from sources outside defence land including all costs such as royalty if any transportation taxes etc. for area filling / forming including raising earth spreading in layers not exc 30 cm thick each layer, watering, compaction with 8 tonne to 12 tonne with power roller & well ramming under the floor and finished to required size and shape etc, any high / depth from requisite level. Notes:- (i) Earth required for the item shall be supplied by contractor out side MOD land of any lead at his own arrangement. (ii) Allcost of procurement of earth including cost of transportation, compaction, royalties, tax etc. shall be deemed to be included in the unit rate quoted by the contractor. (iii) with reference to clause 3.6of MES schedule Part-II on serial page No- 21 it is clarified that measurement of the above item shall be finished after calculated and 10% deduction shall be made from measured and calculated volume to allow for increase in bulk. Therefore, it is advised to quoted the rate considering availability of soil and its lead involved.
Excavation over areas by mechanical means (Hydraulic excavator) / in foundation and area development exc 1.5m but n exc 3.00 and getting out hard and dense soil to get the formation uniform level including dressing, watering and well ramming / rolling in requisite size and shape. Note : Before commencement of the work, the initial level with total station shall be carried out by the contractor with consultation with the Engr-in-Charge/JE wrt decided bench mark and After completing the earthwork, the final level shall be submitted alongwith calculation details in Simson’s rule by the contractor which shall be checked by EIC/JE before carrying out the payment. The rate quoted deemed to be included. No extra payment shall be made separately on this account. All work shall be executed based on Arch & Str drg which are enclosed with tender documents.
M&L for surface dressing n. exc.15 cm deep in soft/loose soil, and removing out of MoD upto requisite distance complete all as specified and directed
M & L for 15 to 20mm machine cut, udaypur green marble, in window cill, kitchen platform and similar work, laid over and including backing coat, in CM 1:4, 15 mm thick, jointed with grey cement slurry mixed with pigment to match the shade of the slab including taking down/dismantling old one complete all as specified and as directed
M&L mild steel bars TMT 6 to 8 mm dia, cut to length,bent to shape required, including cranking, bending spirally for hooping for coh, .nns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality confirming to all as specified and directed.
SCHEDULE A PART-II : COMPOUND WALL Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft loose soil complete all as specifed and directed.
M/L Cement concrete in foundations filling and mass concrete type D-2 1:4:8 ( 40 mm graded aggregates )
M/L for RCC M30 (Design mix) in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns,etc.; basement slabs,under-reamed piles and mass concrete
M/L for RCC M30 (Design mix) in columns, pillars, plers.posts and struts
M/L for RCC M30 (Design mix) in beams, cantilevers, bressurnmers lintels over 1.5m span
M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and matt beams sides and soffits (if any) of foundation and plinth beams; and similar work ; vertical or to batter ,flat
M&L Forrnwork to sides of pillars. posts. struts. piers. columns and stan- rchions for fair finished surfaces of concrete,square,
Use and waste formwork to sides and soffits of floor or roof beam. beam hauchings. girders. bressum-mers.· lintels. cantilevers. shelves including supports. overhangs. etc. also splays between floors and beams. etc.. for flat
S/F framed work such as grills, gratings, etc. with ends of bars shouldered and / or riveted or forged into spikes: framed guard bars : barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290-0 Gde E -165
M&L for providing cement concrete 1:2:4 type B1 (20mm graded aggregate) as in coping, etc including weathering, slightly rounded or chamfered angles and throating, as directed including necessary formwork with glass complete all as specified and directed.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., n exc 10 kg each brackets, conforming to Fe 410-0 or Fe 310-0 (Brackets over 10kg each to be measured under `Structural Steel')
S/F mild steel bars TMT 10 mm dia and over, cut to length,bent to shape required, including cranking, bending spirally for hooping for coh, .nns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conferming to all as specified and directed.
Ditto but 5 mm over upto and including 10 mm dia in stirrups, spacers and binders.to 8 mm dia , qualtiy conforming to all as specified and directed.
M&L Pre-cast cement concrete block masonry Type B1 1:2:4 (20 mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in mortar, complete set in CM 1:6
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including Extra for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc.
M/L rendering 15 mm thick on fair faces of brick work or concrete surfaces other than fair faces of brick surfaces in CM(1:4) finished even and smooth with out using extra cement
M/L preparing new steel surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zink chrome
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M&L in repairs precast cement comcrete louvres and jallies 25mm thick (measured solid) including all mouldings but excluding frame set in cement mortar 1:4
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm hard/dense soil.
Removing excavated material exc. 1.50 km but n exc.5 km and depositing where directed
SCHEDULE A PART-III : SEWAGE DISPOSAL Earth work in excavation by mechanical means (Hydraulically excavator)/ in foundation trenches or drains (not exceeding 1.5m in width or 10Sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m
Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25cm
Removing Excavated soils not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point
Cement concrete bed to 150mm bore cast iron drain pipes in cement concrete (1:3:6) type C-2 using 40mm graded aggregate laid to tails, including packing under and haunching against the sides of pipes with concrete after they are laid and tested complete all as specified and directed.
M&L reinforced concrete pipes, 150mm bore, class NP2 laid and jointed with collars
M&L PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation complete all as specified
M&L Pre-cast cement concrete block masonry with solid blocks exc 10 cm in width and setting CM 1:6 in mortar, Type C-1, 1:3:6 (20mm graded aggregate) complete all as specified and directed.
Plain Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in benching/coping of manhole including necessary formwork all as specified.
M&L rendering 15mm thick in CM 1:4 mixed with water proofing compound on fair faces of solid block masonry or concrete surfaces and finishing even and fair complete all as specified.
Supply only integral water proofing compound
M&L CRS TMT Fe 500D steel bars 6 to 8mm dia as in reinforcement cut to length, bent to shape required including cranking hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing clips etc.
Mild steel work such as rungs, handles
Precast RCC (1:2:4) type B-1 using 20mm graded stone aggregate as in cover slab for manholes etc set in cement mortar (1:4) including use and waste of form work (reinforcement shall be measured and paid for relevant item) all as specified
Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement incl forms,moulds,mitred/stopped ends.
SCHEDULE A PART-IV : HARDSTANDING Surface dressing not exc. 15cm deep in soft / loose soil
Removing excavated materialexc. 1.50 km but n exc. 5 km and depositing where directed
M&L Hardcore of gauge not exc. 63mm, deposited, spread and levelling in layers not exc. 15 cm thick, watered and rammed to true surface with broken stone or boulder:
Cement concrete type C-2, 1:3:6 100mm thick
Sand filling/ coushining under floors or infoundations including watering and consolidation
Machine pressed precastconcrete interlocking paver block any shape and sizeconfirming to IS 15658-2006of 80 mm thickness M-40 Grade with grey cement and pigment
SCHEDULE A PART-V : AREA DRAINAGE Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting ou in soft/loose soil
M&L for PCC 1:2:4 type B-1 (20mm graded stone aggregate) as in surface channels and drains all as specified
Pre-cast cement concrete blockmasonry with solid blocks, exc. 10 cm in width andsetting in mortar type B1 1:3:6, complete all specified and directed
M&L for providing cement concrete 1:2:4 type B1 (20mm graded aggregate) as in coping, etc including weathering, slightly rounded or chamfered angles and throating, as directed including necessary formwork with glass complete all as specified and directed.
M&L rendering 20mm thick on stone fair faces of bricksurfaces in CM 1:4 surface finished even and smooth w/o extra cement
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm hard/dense soil.
Removing of excavated material exc.5Km but n exc 15Km and depositing outside MD Land as per local municipal authority directions
Extra for forming fair finished drain or channel 450 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped end etc.
SCHEDULE A PART-VI : INTERNAL ELECTRIC SUPPLY M&L for point wiring for modular type fittings complete using proper colour coding, 1100 Volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed multi stranded copper conductor cable confirming to IS-694, Part II, ISI marked in and including PVC conduit medium grade not less then 25 mm dia, ISI marked with all accessories concealed in wall/ceiling etc, sunk pressed steel not less than 1.6 mm thick of suitable module, 50 mm deep terminal boxes with 3 mm thick ISI marked plastic laminated sheet top cover fixed with chromium plated brass screws including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi stranded copper conductor cable green colour as continuous earth wire connected to common earth dolly all as specified and directed for the following:-Make of wire: KEI/ Polycab/ BENLO/ Anchor(Panasonic) Make of PVC Conduit pipe : Sudhir / Pressfit / Precision / Sudhakar / Kalinga / Plaza (a) One light point controlled by one switch
(b) One ceiling fan / exhaust fan point controlled by one switch
(c) One three pin switch socket 6 Amps out let on independent board
All as per item No. 142.00 here in before but with 2.5 Sqmm copper conductor with 2.5 Sqmm cable for earth conductor for one 3 pin 16 Amps socket outlet controlled by one switch.
S&F modular type 6A one way SP switch 1 module confirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed. Make: Legrand/ Havell's (Crabtree)/ Schneider/ Anchor (Roma)
S&F modular type 16 A one way SP switch 1 module confirming to IS: 3854-1997 with finguer proof terminal complete all as specified and directed. Make: Legrand/ Havell's (Crabtree)/ Schneider/ Anchor (Roma)
S&F modular type 2/3 pin combined shuttered type 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. Make: Legrand/ Havell's (Crabtree)/ Schneider/ Anchor (Roma)
S&F modular type 2/3 pin combined shuttered typr 16 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. Make: Legrand/ Havell's (Crabtree)/ Schneider/ Anchor (Roma)
S & F modular type 120W step fan regulator, 2 module, single pole one way. 230 volts ISI marked and connecting up complete. Make: Legrand/ Havell's (Crabtree)/ Schneider/ Anchor (Roma)
S & F ceiling rose surface bakelite 65x50 mm with 3 terminals complete all as specified and directed. Make : Anchor / Vinay / Legrand / Maru
S & F Modular cover plate 12 modules confirming to IS : 14772: 2000 all as specified and as directed. Make: Legrand/ Havell's (Crabtree)/ Schneider/ Anchor (Roma)
S & F Modular cover plate 6 modules confirming to IS : 14772: 2000 all as specified and as directed. Make: Legrand/ Havell's (Crabtree)/ Schneider/ Anchor (Roma)
S & F Modular cover plate 3 modules confirming to IS : 14772: 2000 all as specified and as directed. Make: Legrand/ Havell's (Crabtree)/ Schneider/ Anchor (Roma)
S & F 36 W ceiling recessed light of size (2x2ft) having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, Including electrical connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.cat / model No. PCGLLL 36 57 of Polycab or equivalent in wipro / Jaquar/ Bajaj
S & F 20 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, Including electrical connection with 3 core flexible Copper conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make : Bajaj / Wipro / Jaquar
Supply and fixing of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including provision with three core flexible copper conductor cable of suitable size and PVC square blocks complete all as specified and directed Make : Bajaj / Wipro / Jaquar
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM, High Speed with service value 6.00 minimum BEE 5 star rated with brushless direct current motor (BLDC) without remote complete including taking down old unserviceable fan to MES store all as directed by Engr-in-Charge. Make : Bajaj (Energos 28) / Orient (Falcon 400) / Havell’s (Efficiencia Neo BLDC 26W)
Supply & fix Heavy Duty metallic Exhaust fan of sweep 380 mm sweep with frames, blades, mounting anchor fasteners, aluminium louvers made of aluminium sheet of 0.5 mm thickness, rovision of three core 1.5 Sqmm copper cable from celling rose to fan, making opening of required in cement mortar brick wall/RCC for fixing of exhaust fan, making good the distrubed surfaces in CM 1:4, Including scafolding if any required to cary out the work in building of height up to 20 Meters complete in all respects the Exhaust Fan Shall Conform to Cat no EXHD380-4-1 of Crompton or Equivalent from Bajaj/GE. Make :- ALMONARD / ORIENT / USHA / BAJAJ / CROMPTON / HAVELLS
Supply & fix Heavy Duty metallic Exhaust fan of sweep 300 mm sweep with frames, blades, mounting anchor fasteners, aluminium louvers made of aluminium sheet of 0.5 mm thickness, rovision of three core 1.5 Sqmm copper cable from celling rose to fan, making opening of required in cement mortar brick wall/RCC for fixing of exhaust fan, making good the distrubed surfaces in CM 1:4, Including scafolding if any required to cary out the work in building of height up to 20 Meters complete in all respects the Exhaust Fan Shall Conform to Cat no EXHD380-4-1 of Crompton or Equivalent from Bajaj/GE. Make :- ALMONARD / ORIENT / USHA / BAJAJ / CROMPTON / HAVELLS
S & F VTPN DB, 4 way, Outgoing: miniature circuit breaker MCB SP 5-40A (04 No's) Main incoming: molded case circuit breaker (MCCB) -4P - 63 A, 10KA (01 No's) double door, 240 Volts , with Removable gland plates, Removable centre plates, Removable frame, Grounding bar, Neutral bar, Fishbone busbar and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete all as specified and directed. Note: Quoted rate shall be deemed to include for all civil works and provision of copper bus bar of 200 Amps rating. Make :-LEGRAND / SCHEINDER / L & T.
S & F MCB DB, 8 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall,making good the disturbad surfaces and making all connections,complete all as specified and directed. Note: Quoted rate shall also be deemed to include for provision of copper bus bar of 200 Amps rating.Make :- LEGRAND/ SCHEINDER/ L&T/ ANCHOR (PANASONIC)/ SCHNEIDER/ INDO ASIAN
S & F MCB SPN 40 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity 'C' series complete. Make :- LEGRAND/ SCHEINDER/ L&T
S & F MCB SP 5 to 32 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity 'C' series complete. Make :- LEGRAND/ SCHEINDER/ L&T
S&F single pole and neutral enclosure with a two pin and earth and metal clad plug socket complete with one single pole MCB 20 Amp 240 Volts complete all as specified including concealing in wall and directed. Make :- LEGRAND/ SCHEINDER/ L&T
M & L for submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85* C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm NB UPVC medium grade surface/recessed conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS:732- 1989, including making good of disturbed surfaces of wall/celling/floor, all complete as specified and directed. Make of Wire : Polycab/ Finolex ?KEI /RR Kable/ Anchor (Panasonic) Make of Conduit : Sudhakar / Precision / Pressfit NOTE: One run of phase conductor, One run of neutral conductor, One run of earth continuity conductor and 01 run of concealed conduit shall be measured as one length (a) 2 X 1.5 mm2 + 1 X 1.5 mm2 earth wire
(b) 2 X 2.5 mm2 + 1 X 2.5 mm2 earth wire
(c) 2 X 4.0 mm2 + 1 X 4.0 mm2 earth wire
M & L for Earthing complete with GI earth plate electrode of 600mm x 600mm x 6mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire of size 4 mm diameter as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 40 mm diameter, connected to earthing test point, all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. complete as specified and directed by the engineer-in-charge.
Notes: (i) The cost of GI earth continuity conductor with GI pipe 40mm medium grade upto 7.5m is deemed to be included in r/o above item (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item Note: (1) 7.5 RM GI wire in deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately (2) Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (3) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of Copper plate. (4) The Execavation shall be done manually by man power, the quoted rate is inclusive of digging out roots. (5) The quoted rate is deemed to be inclusive of removal of the excess material from the work site.
SCHEDULE A PART-VII : EXTERNAL ELECTRIC SUPPLY Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches all as specified. Make :- M/s Mehtab tiles
M&L for reinforced cement concrete nominal mix M-20 (using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, complete all as specified and directed. (Note - Reinforcement and form work will be measured and paid separately).
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 150 Sqmm 3.5 core including necessary connection and providing cable lugs as required all as specified. Make: Polycab / KEI / Anchor (Panasonic) / Gloster / Finolex / HPL / Havells
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 35 Sqmm 3.5 core including necessary connection and providing cable lugs as required all as specified. Make: Polycab / KEI / Anchor (Panasonic) / Gloster / Finolex / HPL / Havells
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 3.5 core including necessary connection and providing cable lugs as required all as specified. Make: Polycab / KEI / Anchor (Panasonic) / Gloster / Finolex / HPL / Havells
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core including necessary connection and providing cable lugs as required all as specified. Make: Polycab / KEI / Anchor (Panasonic) / Gloster / Finolex / HPL / Havells
Supply and fixing in replacement of LED security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection 4 kv surge in built protection complete all as per directed by Engr- in – charge. NOTE-: The Contractor shall furnished 3 year minimum written warranty Clause on LED luminaries from OEM. Make : Bajaj/Crompton/wipro/Jaquar
S& F in replacement of GI steel tubing medium grade 40 mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge
Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 130 x 180 x 77 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channel including providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - Hensel cat part No KF1010B /National/Sintax
M&L for cutting existing road/hard and dence soil not exc 45 x 60 cm in wide & depth getting out excaveted materials for laying GI tube; returning filling & well rammin watering finish surface 10 cm from top using PCC 1:3:6 not less than 4 inch thick; including removal of surplas soil all as per directed.
S&F of HDPE pipe 50 mm dia, PN-10 for laying in ground, raod crossing etc for cable protection including necessary fittings, clamps for supports, etc complete all as specified and directed. Make:- Finolex / Supreme / Prince / Jain irrigation sytem
Supply, Fixing and connection in repairs of hot dip galvanised octagonal poles of height 6 mtr with 130 mm bottom A/F & 70mm top A/F made up of 3mm thick HT sheet along with base plate of size 200 x 200 x 12mm thick including 4 nos of M20 x 600 long J type foundation bolts and 1 mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point including taking out old u/s poles complete all as specified and directed. Make :- Bajaj
S & F in replacement of security light fitting/Building security light LED type 60 watts, THD<10%, Efficacy 110 Lm/w with Pressure die cast aluminium housing with hight power LED as lighting source and lens embedded PC cover having TOP OPENING seerated driver compartment with IP 66 protection and impact resistance of IK07 with 10KV built-in surge protection device etc including taking out old u/s security lights all as directed by Engineer in charge. Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS.
Supply, install, testing and commissioning Powder coated LT kiosk cubical outdoor type (double door openable) Channel mounted compartmentalized in construction all Confirming to IS 8623 Part 1 1993 CPRI approved factory as per CA fabricated made out of 3.15 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB and TPN Copper bus bars, incomer MCCB and outgoing MCCB, MCB, Contactors The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB. The cubicle shall have a bottom channel & free standing frame made of angle iron of size not less than 50mm X 50mm X 6mm of A detachable predrilled gland plate of thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side.The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5 Sqmm Wire and consisting the following.
M & L for earthing chemical with copper plated 50 mm dia pipe 3 mtr long (100 microns) including Electrodite 50 Kg buried directly in ground including earth bore hole work (earth bore not less than 3 Mtr deep below normal ground level and connected to copper earth strip of size 20×3 mm by means of copper nuts bolts with washers and connected as per following specifications complete all as directed by Engineer-in-Charge. (a) Product Model: ASEEL 19 CP, 3 meter long (Copper Plated) – 100 microns . Fast Electrode, Model FE 80 mm 3 mtr (Pure Copper Single Pipe), Outer Dia is 80 mm with a wall thickness of 2 mm, Inner Dia is 26 mm with a wall thickness of 2.6 mm, Overall Length is 3000 mm, External Corrosion Protection: Copper Plated (100+ microns), Internal Corrosion Protection: In addition to Copper Plated (100+ microns), a ground breaking corrosion resistant Crystalline Conductive Compound is filled and compacted in the cavity within the pipes to enhance the electrodes performance. Conforms to IS: 3043 - 1987 i.e., Code Of Practice For Earthing (+ 10%) variations in dimensions applicable.
(b) Electrodite backfill: Fast Electrode Earth Enhancement Compound, Manufactured using Eco - Friendly minerals, Blended homogeneously with conductive carbon(s), Resistivity: < 5 ohm-metre (In ideal moist conditions); > 5 ohm-metre (Dry Conditions), Ph Value: 7.0 - 8.5, High water retention capacity, Hygroscopic, Ionic & Electronic conduction, Swells when it comes in contact with water thereby engaging constant contact between the electrode surface & soil which is a crucial aspect in the performance of an earthing system. Packing Size : 2 Bags of 25 kilograms, Recommended for normal soil conditions. Conforms to IS : 3043 – 1987 Note : Chemical Earthing for Equipment installed in Workshop.
Supply & Fix copper strip of size 20 X 3 mm duly covered, fixed on porcelain insulators along the wall / roof / ceiling etc complete all as directed. Note : (i) Cost of Porcelain insulators and screw shall be of non-corrosive type and cost is deemed to be included in the quoted rate of the job. (ii) Gap for fixing of support insulator shall not be more than 35cm from one onother.
SCHEDULE A PART-VIII : LIGHTING PROTECTION Supply & Fixing air termination Copper rod 12 mm dia, 300 mm long for lightening conductor including base plate with all necessary nut bolts and drilling job etc.
Supply & fixing for Aluminium strip 25 x 3.15mm on wall/ roof/ batten or recessed or buried in ground including all insulators, screw, nut bolts with saddles and fixing for roof conductor and down conductor complete all as directed by Engineer-in-Charge.
Supply & fixing for Galvanised iron strip 32 x 6mm on wall/ roof/ batten or recessed or buried in ground including all insulators, screw, nut bolts with saddles and fixing for roof conductor and down conductor complete all as directed by Engineer-in-Charge.
M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 nos. 8 mm dia, 25mm long hex. head screw.
Supply and fixing of GI pipe light grade of size 40 mm bore for laying in trenches/floors or walls including all fittings for fixing complete as required and directed by Engineer-in-Charge.
M & L for earthing chemical with copper plated 50 mm dia pipe 3 mtr long (100 microns) including Electrodite 50 Kg buried directly in ground including earth bore hole work (earth bore not less than 3 Mtr deep below normal ground level and connected to copper earth strip of size 20×3 mm by means of copper nuts bolts with washers and connected as per following specifications complete all as directed by Engineer-in-Charge. (a) Product Model: ASEEL 19 CP, 3 meter long (Copper Plated) – 100 microns . Fast Electrode, Model FE 80 mm 3 mtr (Pure Copper Single Pipe), Outer Dia is 80 mm with a wall thickness of 2 mm, Inner Dia is 26 mm with a wall thickness of 2.6 mm, Overall Length is 3000 mm, External Corrosion Protection: Copper Plated (100+ microns), Internal Corrosion Protection: In addition to Copper Plated (100+ microns), a ground breaking corrosion resistant Crystalline Conductive Compound is filled and compacted in the cavity within the pipes to enhance the electrodes performance. Conforms to IS: 3043 - 1987 i.e., Code Of Practice For Earthing (+ 10%) variations in dimensions applicable.
(b) Electrodite backfill: Fast Electrode Earth Enhancement Compound, Manufactured using Eco - Friendly minerals, Blended homogeneously with conductive carbon(s), Resistivity: < 5 ohm-metre (In ideal moist conditions); > 5 ohm-metre (Dry Conditions), Ph Value: 7.0 - 8.5, High water retention capacity, Hygroscopic, Ionic & Electronic conduction, Swells when it comes in contact with water thereby engaging constant contact between the electrode surface & soil which is a crucial aspect in the performance of an earthing system. Packing Size : 2 Bags of 25 kilograms, Recommended for normal soil conditions. Conforms to IS : 3043 – 1987 Note : Chemical Earthing for Equipment installed in Workshop.
M&L for cutting/boring of PCC / WBM / hard standing at a depth not more than 30 cm deep & 20 cm in breath and making good disturbed surfaces as it was existing by using the same new materials on cutting areas/ disturbed surfaces complete.
SCHEDULE A PART-IX : EXTERNAL WATER SUPPLY Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and not exceeding 10 sqm on plan and getting out in hard/dense soil for laying of cables, etc. complete all as specified and as directed.
-ditto- all as per item no 197.00 above but soft/loose soil.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm deep as in hard/soft soil complete all as specified and as directed.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point in soil including spreading in low lying area and leveling complete all as specified and as directed.
M&L for cutting existing road/hard standing not exceeding 45x50 cm in wide & depth getting out excavated material for laying GI tube, returning filling & well rammaing watering finish suraface 10 cm from top including provision of PCC 1:3:6 for repairing, including removal of surplus soil all as directed.
Supply & Laying fixing, connecting and testing steel water tubing, medium grade, galvanised, with screwed and socketed joints, in any length, including supply and fixing all fittings, fixed to walls or laid in trenches / floors etc complete all as specified and as directed for the 50 mm bore, ISI marked. Make-: Tata / Jindal / BST/ Oswal / Surya
Supply & Laying fixing, connecting and testing steel water tubing, medium grade, galvanised, with screwed and socketed joints, in any length, including supply and fixing all fittings, fixed to walls or laid in trenches / floors etc complete all as specified and as directed for the 40 mm bore, ISI marked. Make-: Tata / Jindal / BST/ Oswal / Surya
Supply & Laying fixing, connecting and testing steel water tubing, medium grade, galvanised, with screwed and socketed joints, in any length, including supply and fixing all fittings, fixed to walls or laid in trenches / floors etc complete all as specified and as directed for the 25 mm bore, ISI marked. Make-: Tata / Jindal / BST/ Oswal / Surya
S&F in repairs gunmetal gate or globe valve for 50 mm diameter, conforming to IS-778, Class 2, ISI marked, Copper alloy body, Test pressure (Hydrostatic) for shell 2.4 Mpa and Seat & back seat pressure of about 1.6 Mpa with maximum working temperature of about 45 °C with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, complete all as specified and as directed. Make :- Leader / Zoloto / Shakti
S&F in repairs gunmetal gate or globe valve for 40 mm diameter, conforming to IS-778, Class 2, ISI marked, Copper alloy body, Test pressure (Hydrostatic) for shell 2.4 Mpa and Seat & back seat pressure of about 1.6 Mpa with maximum working temperature of about 45 °C with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, complete all as specified and as directed. Make :- Leader / Zoloto / Shakti
S&F in repairs gunmetal gate or globe valve for 25 mm diameter, conforming to IS-778, Class 2, ISI marked, Copper alloy body, Test pressure (Hydrostatic) for shell 2.4 Mpa and Seat & back seat pressure of about 1.6 Mpa with maximum working temperature of about 45 °C with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, complete all as specified and as directed. Make :- Leader / Zoloto / Shakti
Cutting in position existing cast iron main pipe line for connection of GI pipe of size 50 mm dia including insertion of tee bore for tapping out for filling tank with connected fittings i.e. Tee, collar, tail piece, run lead joints and necessary excavation, refilling and disposal of surplus material complete as directed.
M& L for supplying, hoisting and fixing rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) as per IS 12701-1996 (Reaffirmed 2006) of 1000 Litres capacity with virgin food grade plastic, UV stabilized tank and lid, two layers protection with black outer layer for superior UV protection and white inner layer to see water leval and tank condition including covers, hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes etc complete all as specified and as directed. Make-: Sintex/ Reno/ Plasto / Supreme
Supply and fix in repair 40 mm bore PVC Ball valve ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron rod and fixed complete all as specified and directed. Make -: Prayag / Shakti / Airaeuro / Agrotech / Teleflo / Techno International
M&L for renewal of valve pit of size up to 80 cm x 80 cm x 80 cm (internal diamension), stone / brick construction including all necessary excavation and earth work in any type of soil, returning, filling in disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, PCC in foundation for mix (1:2:4) type D2 brick mansonary in cement mortar (1:4) rendering 12 mm duck in cement mortar (1:4) internally ,finished even and fair and polishing flush externally as the work proceeds in the same mortor. Mild steel angle iron 40 x 40 x 6 mm frame MS sheet cover 3.15 mm thick with handle and locking arrangement, painting all exposed MS work with two coats of synthetic enamel paint of the that as approved by the Engineer - in - charge over a coat of red oxide primer and painting all the MS embeded in PCC with two coats of black bitumenous paint complete all as specified.
SCHEDULE A PART-X : AIR CONDITIONING Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.20 of capacity 3 Ton electric driven single phase 230 Volt, Copper energy efficient complete all as specified and directed. Make :- Voltas/ Blue Star/ Carrier/ Mithsubishi/ Daikin
S&F single pole and neutral enclosure with a two pin and earth and metal clad plug socket complete with one single pole MCB 20 Amp 240 Volts complete all as specified including concealing in wall and directed complete all as specified and directed. Make - IndoAsian/ Legrand/ Anchor (Panasonic)/ L&T
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 4 Sqmm 2 core including necessary connection and providing cable lugs as required all as specified. Make: Polycab / KEI / Anchor (Panasonic) / Gloster / Finolex / HPL / Havells
Supply and fix copper tube of size 1/4" bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air conditioners complete all as specified and directed. Make - Best available in market
Supply and fix copper tube of size 5/8" bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air conditioners complete all as specified and directed. Make - Best available in market
Supply and fix PVC drain pipe of size 5/8" bore for supply pipes for air conditioners complete all as specified and directed. Make - Best available in market
Supply and fix 4 core 2.5 sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade ISI marked complete all as specified and directed. Make - Finolex/ KEI/ Polycab/ Benlo
Supply and fix Heavy duty Water Proof Powder coated mounting bracket for installation of outdoor unit of air condiioner made out of 2 mm thick high grade steel with suitable fastener, MS nuts, bolts M8 x 45mm, washer, bolt M8 x 30mm nut, bolts & washers etc. duly painted complete set all as specified and directed. Make :- Companion Sleek, Aircool Sales Corporation or equillant make.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm×6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
M/s Shreeji Construction Co (BID ID -3368619)
mp construction co (BID ID -3377232)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .