Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹26.9 L+₹3.4 L (14.5%)Rejected-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASPURA CV RAMAN NAGAR BANGALORE 560093 | BENGALURU URBAN | KARNATAKA | 560093 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹28.4 L+₹4.9 L (20.9%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | L3 | Rejected-Finance Not L1 |
Tender Value
Refer Docs
EMD Value
₹58,000
Closing Date
27 Oct 2023, 6:00 pmClosed
GE(South) Bangalore
GE(South) Bangalore
ANNUAL REPAIR AND COMPREHENSIVE MAINT OF SWIMMING POOL AT RMS AND SUB AREA OFFRS MESS AND REPAIR / MAINTENANCE OF DG SETS, AMF PANELS AND CERTAIN MISC ITEMS UNDER GE(SOUTH) BANGALORE
2023_MES_620924_1
8733/E8
Open Tender
Civil Works
Item Rate
180 days
Bangalore
As per tender document
6 documents required · 6 mandatory
₹500
GE(South) Bangalore
₹58,000
Yes
16 Dec 2023
29 Sept 2023
30 Oct 2023
29 Sept 2023
27 Oct 2023
13 Oct 2023
Amount
Maintenance of swimming pool of capacity 4.5 lakhs gallons by maintainng water parameter as per Indian standard quality tolerance for water including folowing :- (a) Removing /Bailing out sedimentation from bottom of entire swiming pool using suction sweeper befrore opening swiming pool for users each day on day decided by Engr-in-Charge . (b) Removing all floating particles by using strainer before openig swiming pool for users weach day / on days as decided by user and time of cleaning as decided by Engr-in-Charge. ( c) Cleaning of cascade system & mixing of chemicals as reqd for swiming pool
All as per Item No -1 but swimming pool capacity 2.3 Lakh Gallons
Supply only foloowing items to be fixed under Sch Item No- 1 & 2
Supply only bleaching powder ISI marked superior quality all as specified.. Make-Kaveri/Grasim/Vikram
Supply only Copper Sulphate (ISI marked) all as specified. Make-VCI Ltd / Reliance Gijaarath / or equivalent.
Supply only Soda Ash (ISI marked) all as specified. Make-DCW Ltd / Tata / or equivalent.
Supply only Algae sider liquid all as specified. Make-Comercial / Equivalent.
Supply only Sodium Hypo Chloride (ISI marked) all as specified. Make-DCW Ltd /Tata or equivalent.(TCCA90)
Servicing pressure filter of capacity 25000 LPH by opening pressure filter and taking down filter media of different sizes approximately (10000 Kg)carefully, opening the strainer and reset the same after replacement of filter media cleaning filter nozzles with pressure water, refill the filter bed with fresh media and cleaning the pebbles /20mm / 10mm / 40 mm / 2mm topping up the short fall with new media, servicing the backwash system, replacing the un serviceable pressure gauge, testing and commissioning all as directed.
Servicing pressure filter of capacity 45000 LPH by opening pressure filter and taking down filter media of different sizes approximately (10000 Kg)carefully, opening the strainer and reset the same after replacement of filter media cleaning filter nozzles with pressure water, refill the filter bed with fresh media and cleaning the pebbles /20mm / 10mm / 40 mm / 2mm topping up the short fall with new media, including fabrication work inside pressure filter 150mm MS pipe and40mm GI pipe cutting , grinding , weldingand painting work after completion of work servicing the backwash system, replacing the un serviceable pressure gauge, testing and commissioning all as directed.
Cleaning of balancing tank of swimming pool of capacity up to 15000 ltrs by cleaning the balancing tank with high pressure water jet to remove all masses, algae and dirt, taking out dirt and sludge with sludge machine and disposing the same to a safe distance, scrubbing the internal walls and floor with industrial vacuum cleaner and finally applying anti bacterial sterilization to walls and floor of balancing tank complete all as specified and as directed.
Supply and fixing in repalcement of nylon rope of 20 mm dia complete all as specified and as directed.
Supply and fixing in replcement flexible hose pipe ribbed type high density 40 mm size all as specified. Make : Dinoflex, KR flex, Padma flex.
Supply and fixing in replcement flexible hose pipes ribbed type high density 50 mm size all as specified.Make : Dinoflex, KR flex, Padma flex.
Supply and fixing in replcement nylon rope 12 mm dia for the suction sweeper
Supply and fixing in replcement superior quality detachable type telescopic brush suitable for telescopic rod of 30mm dia ( bottom 28mm dia )Make:-Astral,Trios or Equivalent
M&L for backwashing of swimming pool water through pressure filter start the motor and complete, sludge , particles to backwash pipe line and duct every month once time complete all as specified and directed.
M&L preparation of surfaces of pressure filter for painting of 2 Nos MS Tank vertical type with one coat of redoxide primer after grey colour painting of complete pressure filter outer surface and blue colour painting of all external pipes up to size 150mm , aluminium paint for motors 5 Nos and red colour paints of all valva handles and motor back side fan cover after paintiing work write a SM No of pressure filters complete all as specified and directed by Engr in Charge .
M&L preparation of surfaces of pressure filter for painting of 1 Nos MS Tank vertical type with one coat of redoxide primer after grey colour painting of complete pressure filter outer surface and blue colour painting of all external pipes up to size 150mm , aluminium paint for motors 5 Nos and red colour paints of all valva handles and motor back side fan cover after paintiing work write a SM No of pressure filters complete all as specified and directed by Engr in Charge .
M&L for pressure jet machine cleaning of water cascade and deep side water inlt pipe and lengeth side holes cleaning through compressed pressure air to liase with BWSSB Jet machine and whenever reqd at site cleaning the blocked holes complete all as specified and directed by Engr in Charge .
Supply and fix sluice valves PN 1.6 of size 250mm, IS marked these valves are fixing sandwich type fitting requirement necessary MJ collar Flange joint may be arrange fxing of new valves all as specified and directed.
Supply and fix cast iron body foot valve 250mm bore spring type which ever be required for fixing including making good disturbed surface and taking out old cast iron foot valve from the suction side of the pump set from swiming pool sump etc. complete all as specified and direct at site.
Supply and fix sluice valves PN 1.6 of size 80mm, IS marked sandwich type fitting requirement necessary MJ collar Flange joint may be arrange fxing of new valves all as specified and directed.
Disconnecting the cenrifugal pump set of 10 HP capacity from motor by dis-engaging the coupling , taking out the pump from the foundation and transporting to the workshop, opening the pump, taking out the shaft along with impeller , removing the foreign materials from the inner casing , cleaning checking for wearing out of the impeller , bearing sleeves shaft etc. replaing the worn out parts , assembling the pump complete by replacing the gasket, nuts bolts washers , greasing , greasing of bearings all as required , transporting pump to the site mounting on base frame , checking for prpoer alignment of pump shaft with motor shaft , adding the the steel sheets as required , checking with dial gauge for correct alignment , connecting the shafts couping and test runing for smooth operation all specified and as directed. NOTES :- (i) Transportation and necessary T&P for shifting the motor to workshop & back is deemed to be included in the quoted rates. (ii) Major spares like impeller , sleeves etc will be measured and paid under relevent items of this schedule .
All as per Item No- 24 here in above but 3 HP.
Supply only the following items to be fixed under item No 24 & 25
(a) CI impeller complete with nut bolt an key matching with exiting pump at site
(b) Bearing set for front and rear matching with exiting make at site
(c) Terminal board matching with existing at site
(d) Shaft matching with exsiting
M&L for laying , connecting & testing single core copper conductor flexible PVC insulated heavy duty unsheathed cable 11000 volts grade10 Sqmm from satrter panel to motor connecting box cutting of existing PCC groove and isert the PVC Conduit pipe suitable size up to motors and connecting the cable all as specified and directed by Engr in Charge
M&L for laying , connecting & testing single core copper conductor flexible PVC insulated heavy duty unsheathed cable 11000 volts grade 06 Sqmm from satrter panel to motor connecting box cutting of existing PCC groove and isert the PVC Conduit pipe suitable size up to motors and connecting the cable all as specified and directed by Engr in Charge
Supply,installation,testing and commisioning factory made,CPRI Approved LT Panel board indoor type, of size not less than 900x900x600mm powder coated made of 3.0 mm thick CRCA Sheet,weather and vermin proof with double stud hinged door front with drop bolt,shutter type windows at both sides of top and bottom duly internally secured with wire mesh,GI earthing strip stud at both bottom side,removable gland plate with compartmentalised cubical with 1.6mm thick CRCA sheet front opened double stud hinged door, all switch gears and changeover switch suitable to accomadate wall mounting fixing arrangement comprising of the following :- (RMS Swiming Pool)
Incoming
(i) MCCB 100 amps,25kA, 415 Volt,50Hz, 4P With thermal based release-1No.
(iv) LED cluster indication lamp(R Y B) set of 3-1set
Busbar : - Copper busbar 3 phase 4 wire of 200 to 300 Amps supported with ebonite insulation at 20cm interval -1set
Outgoing
(i) MCB TPN 40 Amps 415 Volt,50Hz,- 03 Nos. for motor starter (Make- Indoasian/havells/Legrand )
(ii) MCB TPN 32 Amps 415 Volt,50Hz, - 02 Nos. For suction motor and priming motor starter -Make- Indoasian/havells/Legrand
(iii) MCB SPN 32 Amps 230 Volt,50Hz, - 01 Nos. For Bldg power supply (Make- Indoasian/havells/Legrand
(iv) Star delta starter 3 phase 415 volt 1.5MF inbuilt single phase preventor for 10 HP Motor Make- L&T - 03 Nos
(v) DOL Starter 3 phase 415 volt inbuilt single phase preventor or 03 HP Motor Make- L&T - 02 Nos
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal etc complete.
M/L for maintenance and servicing of DG SET complete including draining out of diesel from tank , cleaning the tank thoroughly and refilling the drained out diesel , drain out engine oil from the sump , flushing the sump thoroughly and replacing the fuel filter ements 2 nos ,super bypass filter element 1no, oil filter element 2 nos and filling the starting batteries elecrtrolite to be maintain the required specific gravity, applying the petroleum jelly in battery terminal poles and charging , replacing the diesel tank level tube, cleaning the entire DG set with accessories as prescribed by the manufacturer , checking of voltage ,frequency, amps , fuel, oil , water level and exhuast leakage etc. Tightening all the bolts & nuts to the required torque ..etc and testing as directed by Engineer In Charge and recording the test result complete for DG set of capacity 250 KVa to 380KVA.
Note:- Engine Coolant, filters and belts will be measure nd paid seperately . (b) Cost of all minor items ie gaskets grease liner etc deemed to be inlcuded in quoted rate.
All as per item No-31 but 100 KVA to 160 KVA
All as per item No-31 but 40KVA to 82.5 KVA
All as per item No-31 but up to 35 KVA
Supply only following items to be fixed under mentioned of above DG sets.
(a) Air filters element for DG set of capacity 250KVA to 380 KVA .
(b) Air filters element for DG set of capacity 40KVA to 82.5 KVA .
(c) Air filters element for DG set of capacity up to 35 KVA
(d) Fuel filters element for DG set of capacity 250KVA to 380 KVA .
(e) Fuel Filters element for DG set of capacity 40KVA to 82.5 KVA .
(f) Fuel filters element for DG set of capacity up to 35 KVA
(g) Lube Oil filters element for DG set of capacity 250KVA to 380 KVA .
(h) Lube Oil Filters element for DG set of capacity 40KVA to 82.5 KVA .
(j) Lube Oil filters element for DG set of capacity up to 35 KVA
(k) Fan belts matching with existing for DG sets capacity 250 KVA to 380KVA
(l) Fan belts matching with existing for DG sets capacity 40 KVA to 82.KVA
(m) Fan belts matching with existing for DG sets capacity up to 35 KVA
(n) Engine Oil specificaton as per manufacturer recommendadtion
(o) Coolant of specificaton as per manufacturer recommendation
M&L for dismantling self starter from DG sets capacity up to 380 Kva and reassembling after replacement of unserviceable items including fixing and testing complete all as specified and directed . Note :- Unserviceable items will be measured and paid seperately .
(a) Rewinding of stator coils 250KVA to 380 KVA
(b) Rewinding of stator coils up to 160 KVA
(c) Replacement of bearing sets suitable size of capacity 250KVA to 380 KVA
(d) Replacement of bearing sets suitable size of capacity up to 160 KVA
(e) Replacmnet of Gear wheel set complete set
M&L for dismantling charging alternator for DG set of any capacity up to 380 KVA and re asssembling after replacement of unserviceable items including testing complete all as specified and directed . Note :- U/S item supply only following items to be fixed under items above .
(a) Rewinding of starter /rotor coils
(b) AC to DC Converter set
Supply and fixing in replacement AVR unit for alternator of any capacity matching with existing sample complete all as specifeid and directed
M&L for dismantling of FIP and calibration servicing at admissible pressure for DG set of any capacity and make including minor spare parts if required complete all as specified and directed
Dismantling of exitor unit unit assmbly and rewinding of starter /rotor coils including replacement AC/DC connector complete including testing complete all as specified and directed
S&F in replacement control contactors /relay matching with exiting for AMF Panel complete all as specified and directed.
M&L for replacement of control wiring of AMF with 1.0Sqmm flexible copper conductor single core or as per existing including testing complete all as specified and directed by ngr in Charge.
Repair/maint of Automatic change over switch of AMF panel by checking logic circuit , rplacement of coils or any item reqd for making ACs functional complete all as specified and directed by Engr in Charge.
M/L moulded PVC body low maintenance Lead acid battery 12 volt 180 AH Make :- Exide
M/L moulded PVC body low maintenance Lead acid battery 12 volt 130 AH Make :- Exide
M&L servicing of External Battery Charger 12 volt assy [Make - Naren] by disconnecting the AC supply and taken to service centre after dismantling the same cleaning all accessories, replace the burnt parts like :- diodes , recifiers and DC & AC fuse units and reassambling the same , refitting the engine and testing all as directed .
M/L for fixing the battery charger 24 volt DC in existing control panel including necessary connections , cutting for fixing the volt meter , ammeter and connecting the battery all as directed.
Repair/Maint of following mentioned radiator assy of DG set by disconnecting and removing from eingine , dismantling the top & bottom chambers , descalling the sediments and scales , corrosion ..etc by means of suitable chemicals and high pressure water washing , air cleaning , re assembling the same with new gaskets, including arresting leakage , if any and fixing to the engine with new hoses clips etc including cleaning the slots as required chemicals and other T&P reqd for job Note : - Cost of transportation if any, chemicals and other T&P reqd to complete job is deemed to be inclue in quoted rate The rate qouted rates.
250KVA to 380 KVA
100 KVA to 160 KVA
40 KVA to 82.5 KVA
up to 35 KVA
S&F in replacement of injector HP pipe from FIP to injector for DG set up to 250 KVA matching with existing sample complete all as specified and directed by Engrin Charge.
S&F in replacement Hose pipe for radiator assembly complete all as specified and directed
S&F in replacement Flexible pipe for DG set complete all as specified and directed by Engr in Charge .
S&F injector asembly for DG set up to 250 KVA complete all as specified and directed by Engr in Charge .
M&L for dimantling of defective water pump assembly by disconnecting hoe pipe connections , fanbelt, radiator connection and reapairing with seal etc to make leak proof suitable for up to 380 Kva DG set all as specified and directed by Engr in Charge .
S&F In replacement of fly wheel ring of up to 250 KVA generator by dismantling alternator from engine removal of unserviceable ring, insertion of new ring on shaft and refixing alternator to Engine duly aligned in position complete all as specified and directed .
M&L for dismantling of Turbo charger assembly by disconnecting xhaust and Air pipe clening of fan blades , replacement to spacer kit and other minor items complete including refixing in position complete all as specified and directed .
S&F in replacement of Expansion bellow suitable for DG set up to 250 KVA complete all as specified adnd directed .
S&F stop solenoid switch complete including plunger and mounting arrangements for up to 250 KVA DG set matching with exiting sample complete all as specified and directed .
Servicing of 100 ltr capacity solar water heater with elctric back up system after disconnecting the existing water supply/electrical connections from any height of the building , including stripping out the hot water vessel by taking out the outer cover insulating materials heating eleement cleaning the same materials with anti bacterical descalling and anticorrision spray painting where ever necessary and continous brazing of the inner conytainer for arresting leakages including repalcement of defective / worn out spare parts and re assembling the system and re - installed at the same ;laoction connecting up water/ electrical connections and testing for satisfactory performance complete all as specfied and as directed.
All as per item No 58 herein before 200 Ltrs capacity sloar water with electric back up system
All as per item No 58 herein before 500 Ltrs capacity sloar water with electric back up system Note:- Serving of flat plate collector shall be measured and paid seperately under respective items of this shedule.
Servicing/cleaning of 100 ltrs capacity Solar flat plate collector box after disconnecting th existing water supply from any height of thr buliding dismanting the box cleaning and serving the aluminium channels /sheets /angels and solar glass panel including repalcement of defective/worn out components and re assembling the box connecting up water connections copper header/riser pipes nozeels etc cleaning the same materials with anti bacterical descaling and anti corrrision spray painting where ever necessary and testing for satisfactory performance complet all as specfied and as directed.
Notes : (i) Replacement of solar glass panel if required shall be measured and paid separately under respective items of this schedule.
All as per item number 61 above but 200 ltrs capacity solar flat plate collector box
All as per item number 61 above but 500 ltrs capacity solar flat plate collector box
S & F heating element for solar water heater up to 500 litres with rubber gasket threaded push type 230 V , 3KW fixied in repairs all as specified and as directed
S & F thermostat suitable of solar water heater up to 500 litres capacity and the range 0 to 80 degree centigrade fixed in repair all as specified and as a directed make Theeta/Racold/Philips ISI market
S&F 5mm thick toughned plain glass panels suitable for solar water heater plate colltor box , fixed in repairs suitable for existing make all as specified and as directed .
Supply & replacement of back up kit of solar water heater 3 KW including temprature gauge complete all as specified and as directed.
Supply and replacement of solar collector panel of 100ltr capacity for solar water heater complete all as specified and directed.
Aavani BUILDERS AND CONTRACTORS
SREE CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .