GE 874 EWS
GE 874 EWS C/O 56 APO
REPAIR/ MAINT OF OVERHEAD LINE TO UNDERGROUND CABLE AT ZANGLI AND PROVN OF STABLIZER AT DRUGMULA UNDER GE 874 EWS
2024_MES_653162_1
GE 874/EWS-32/2024-25
Open Tender
Civil Works
Works
120 days
Kupwara
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 874 EWS
₹90,940
26 Oct 2024
10 May 2024
17 Jun 2024
10 May 2024
13 Jun 2024
27 May 2024
Amount
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.
Supply, Laying , jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete of size 70 sqmm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of poles, stay assembly and laying LT/HT Cable as in any type of soil and getting out complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified and directed. Note: Punned thickness 18 cm shall be measured and paid.
M&L for Brick for burnt sub class 'B' bricks laid dry, flat, width wise along the length of cable in trenches after sand cushioning for protection of underground cable complete all as specified and directed.
Supply, Installation, testing & commissioning of totally enclosed feeder pillar outdoor type (IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type(independent cabin including locking arrangement for each MCCBs , bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt 50 Hz AC, supply internally wired with copper conductor , TPN bus bar of copper strip (4 Nos) insulated by heat shrinkable sleeves & clips on shrouds for joints bus bar shall be designed to withstand a fault level at 415 Volts having legs 105cms made out of 65x65x6 mm angle iron grouted on PCC 1:3:6 upto 45 cms panel should be 60 cms above the Ground Level. Comprising the following : (i) The panel shall be front operated with independent side cable cabin for entry and out going from the bottom with cable glands. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 60cms
Note:- Cost of grounding of panel with PCC 1:3:6 (40 mm thick stone aggregate ) 90 cm above ground level, deemed to be included in the item rate . No extra payment will be made.
(Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 50 KA .Earth bus shall be part of the main feeder pillar.)
(a) Bus bar chamber made out of CRCA sheet open able from front side having copper bus bar of 3 phase and neutral of size not less than 1.5 times the rates capacity of Incomer ACB/MCCBs made out of electrolyte copper strip shall be insulated with colour coded heat shrinkable sleeve
(b) MCCB 350 Amps breaking capacity 25 KA (Incoming) 4 pole,415 Volts, 3 Phase, 50 HZ- 01 Nos
(c) MCCB 125 Amps breaking capacity 16 KA (out going)4 pole,415 Volts, 3 Phase, 50 HZ - 04 Nos
(d) MCCB 100 Amps breaking capacity 16 KA (out going)4 pole,415 Volts, 3 Phase, 50 HZ - 02Nos
(f) Phase indicating lamp (Set of three)- 03 Nos (RYB)
Note:1.The MCCB should have Ics=100% Icu for short circuit breaking capacity of minimum 16 kA/36 KA as indicated rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as standard feature of manufacturer,
M & L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.5 mtr below normal ground level , filled around with 15cm thick alternate layers of charcoal dust and common salt and connected with and including up to 7.5 RM to
Galvanized Iron Strip 32x6mm by means of bolts and nuts check nuts and washers of galvanized iron or steel and thimble ends of the earth strip to connected to main panel and protected by Galvanized iron pipe length Grade 40mm before and watering pipe 20mm dia light grade with funnel and wire mesh, PCC 1:3:6 type C-1 in chambers RCC 1:2:4 type B-1 in pit cover reinforced with 8mm dia deformed bars @15 cm centre to centre both ways including necessary excavation and earth work as directed complete all as shown in electric plate No-3 of MES Sch Part-1 of 2009. PCC Chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering complete all as per specified and directed. Note: Upto 7.5 Mtr length of pipe of 40 mm dia and GI strip shall be deemed to be included in unit rate quoted by tenderer GI pipe and GI strip beyond 7.5 mtr or test point will be measured separately under respective item.
M & L for smc enclosure of 155x155x100(Outdoor pole mounted boxes IP56 with metric knocks out for cable entry) for single row 2 way MCB Mountable outdoor pole mounting type including one single pole MCB 240 Volt 'C' Curve type 6 Amps with rapturing capacity 10KA having entry from lower side with cable gland for cable of size10/16 sqmm 2 core including locking arrangement complete and enclosure to be fitted on pole with clamps nuts, bolts and washers complete all as per specified and directed.
S & F of two runs of single core of size 2.5 sqmm phase and neutral and one run of 1.5 sqmm for earth continuously drawn through steel tubular pole and connecting with proper copper terminals , including PVC Conduit for giving connection between looping box and light fitting complete all as per specified and directed.
S & F for Rigid non-metallic PVC conduit 20mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. heavy duty wall thickness 2.00mm for street light fittings complete all as per specified and directed.
M & L for GI Tubing light grade 80mm bore for cable protection laid in trenches in road crossing or fixed to wall/Pole complete all as per specified and directed.
M & L for GI Tubing light grade 100mm bore for cable protection laid in trenches in road crossing or fixed to wall/Pole complete all as per specified and directed.
M & L for bracket in replacement for fixing of street light fittings bend to shape , made out of 32/40mm dia GI pipe medium grade up to 1.5 mtr long fixed with and including two sets of MS clamp made out of flat iron of size 50x6mm fabricated to shape and fixed with nuts , bolts & two coats of aluminium paint over a coat of red oxide primer complete all as per specified and directed.
Supply, Installation and fix Voltage stabilizer for automatic operation, three phase, naturally, oil cooled, indoor type & designed for input variation between 300 to 480V with output voltage stabilized at 415 with minimum accuracy of + 2.5% and speed of correction of 8 volts per second and capacity of 100 KVA with full tank filled with Transformer oil of minimum BDV value of 50kV, including all accessories included. The Stabiliser shall be provided with Over Load protection, Digital Three phase Voltmeter and Ammeter (the voltmeter and ammeter shall display all three phase values simultaneously), bypass system (to bypass Stabiliser and provide direct supply to output). The Stabiliser shall be provided with a PCC Foundation (of 15cm height). The stabiliser shall be provided with digital three phase voltmeter, digital three phase ammeter, bypass changeover/ knob to bypass the stabiliser. The stabiliser Shall operate in each phase, independent of the other phases. The stabiliser shall have knob for conversion of stabilisation from Automatic to Manual complete all as specified and as directed.
GH MOHD SHAH AND CO
M/S ASHRAF CONSTRUCTIONS
m/s mohd saleem and co
Bidder Name
M/S ASHRAF CONSTRUCTIONS
GH MOHD SHAH AND CO
Kesar Impex
m/s mohd saleem and co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .