| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Qualified in F-bid. | |
| 2 | L2₹11.7 L+₹2.2 L (23.0%)Rejected-Finance | L2 | Rejected-Finance Rejected not being Lowest. | |
| 3 | L3₹13.2 L+₹3.7 L (39.0%)Rejected-Finance 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L3 | Rejected-Finance Rejected not being Lowest. | |
| 4 | L4₹13.3 L+₹3.8 L (39.5%)Rejected-Finance | L4 | Rejected-Finance Rejected not being Lowest. |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
31 Dec 2021, 5:00 pmClosed
CWE No 2 Meerut
Headquarters Commander Works Engineer No 2 Military Engineer Services Boundary Road, Near Supply Depot Meerut Cantt-250001
REPAIR/ MAINT TO STREET LIGHT, SECURITY LIGHT, HIGH MAST LIGHT, TIMERS, UG CABLES AND ASSOCIATED EQUIPMENTS AT RTS AND DEPOT SAHARANPUR UNDER GE ROORKEE
2021_MES_492347_1
95151/RKE/E8
Open Tender
Civil Works
Item Rate
120 days
Roorkee
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Roorkee
₹30,000
5 Feb 2022
3 Dec 2021
3 Jan 2022
3 Dec 2021
31 Dec 2021
17 Dec 2021
Amount
S&F bulk head fittings IP-65, surface mounted comprising LED luminaire 10W of high brightness Make : Havells : Cat part No. RUGBYNEONFT10WLED 860SSYMTOPC or equivalent Phillips Cat part WT202W LED6S NW PSU S2PC or equivalent in CG
M&L for MCB single pole,6 to 40 Amp 240 volt B curve 10 KA, IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed MAKE-LEGRAND / SCHNEIDER /C&S
Taking down defective 25/36/40/45/60/250 Watt LED light fitting/SV/MH fittings, street light fitting mounted on pole/bldg on bracket disconnecting, testing all components, dismantling of defective components such as choke, igniters, holders, capacitors, and providing PVC cable for wiring lamps, including cleaning of cover, connection with supply and testing the street light fitting after fixing new components and including trimming of branch if obstacle for lights to illuminate the area and then mounting to its original position and making the fitting functional all as specified and directed by Engineer in Charge.
Taking down defective 90 Watt led fitting mounted on 11 mtr long Semi high mast consisting of LED flood light fittings (Approx 4 to 6 Nos), street light fitting, mounted on 11/13mtr long high mast pole on bracket/ round ring, disconnecting, testing all components, dismantling of defective components such as driver of LEDs and cleaning of cover, connection with supply and testing the street light fitting after fixing new components and then mounting to its original position and making the fitting functional all as specified and directed by Engineer in Charge at site.
Taking down defective 250/400 Watt SV/MH lamp type light fittings, High mast light fitting through motorised /manual system, mounted on 21 mtr long high mast pole on bracket/ round ring, disconnecting, testing all components, dismantling of defective components such as choke, igniters, holders, capacitors, and providing new PVC cable for wiring lamps, including cleaning of cover, connection with supply and testing the street light fitting after fixing new components and then mounting to its original position and making the fitting functional all as specified and directed by Engineer in Charge at site. Note for item No3 to 5: (i) No T&P will be issued by the Department. (ii) Rates quoted by contractor will include cost of the starter, bipin holder, pvc wire, capacitors, required for maintenance of Street Lights for TL fitting/HPSV fitting. (iii) Rates also include repairing of defective street light timers, fault in street light feeders etc (iv) During whole period of currency of contract any fitting will not be considered for more than once for the payment purposes.(v) Spares such as choke, igniters, driver of LEDs, lamps, holders (supplied by contractor) shall be paid and measured separately under appropriate items.
Supply and fixing in replacment of LED flood light 120 Watt 230 Volt AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. Make : Havells, Cat Part No. JETAIRISFLS120wLED757SYMLTG or equivalent in CG, Phillips
Supply and fixing in repair cable PVC insulated and PVC sheathed size 4 Sqmm twin core stranded aluminium conductor complete all as specified and directed .
M&L for bracket made of GI light grade pipe 1.2 Mtr long of size 40 mm bore bend to shape as per site requirement fixed to pole with 40 x 5 MM -02Nos, size clamps bolts, Nuts, washers including painting two coats of aluminium paint over a coat of primer all as specified and directed by E-I-C
Supply and fixing LED flood light luminaries of 250W, with pressure die cast aluminium housing with sealed toughened glass cover in frame ,IP 65 protection and with all fixing arrangement , nuts, bolts and washer connecting to electric system with 2.5 Sqmm PVC Aluminium stranded conductor 2 core up to require length and to be fixed on 11 Mtr long pole including taking down old unserviceable fitting any type and description complete all as specified and directed. Make- C&S cat part No LTEF250WHPLED, or equivalent in Havells, Crompton and phillips
Taking down unserviceable flood light fittings and supply and fixing new generation energy saving & environment friendly, powder coated pressure die-cast aluminium IP65 roadway luminaries with LEDs with lens as light source & exclusively designed along with electronic driver type street light fitting suitable for 100/90 watt capacity LED lamp with and including all accessories duly pre-wired, fixing on existing bracket and taking down the unserviceable light to store at site for street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make-C&S Orion 3.0 Series, Cat part No:LTEF90WHPLED, or equivalent in Havells, CG, Phillips
Taking down unserviceable security light fittingsSupply and fixing new generation energy saving & environment friendly, powder coated pressure die-cast aluminium IP65 roadway luminaries with LEDs with lens as light source & exclusively designed along with electronic driver type street light fitting suitable for 60 watt capacity LED lamp with and including all accessories duly pre-wired, fixing on existing bracket and taking down the unserviceable light to store at site for street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make- C&S cat part No LTESS60WLED/LS, Havells, CG, Phillips
Taking down unserviceable security light fittingsSupply and fixing new generation energy saving & environment friendly, powder coated pressure die-cast aluminium IP65 roadway luminaries with LEDs with lens as light source & exclusively designed along with electronic driver type street light fitting suitable for 45 watt capacity LED lamp with and including all accessories duly pre-wired, fixing on existing bracket and taking down the unserviceable light to store at site for street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make- C&S cat part No LTESS45WLED/LS, Havells, CG, Phillips.
Taking down unserviceable security light fittingsSupply and fixing new generation energy saving & environment friendly, powder coated pressure die-cast aluminium IP65 roadway luminaries with LEDs with lens as light source & exclusively designed along with electronic driver type street light fitting suitable for 25 watt capacity LED lamp with and including all accessories duly pre-wired, fixing on existing bracket and taking down the unserviceable light to store at site for street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make- Havells Model NO Endura Pearl 25W MP Cat Part No ENDURAPEARLSL25WLED757SASYTOPCMP or equivalent in CG, Phillips.
S&F in repair Astronomical+Digital Time switch model Havells :HSN code :9107, Cat Part No.DHTQB01016 or equivalent in Phillips/CG/L&T
S&F in repair nature time switch single phase model swadeep -02 sensor only along with switching timer complete all as specified and directed by Engineer-in-Charge.
S&F in repair contactor 65 Amp 3 Phase , 415 V , as per IS 13947-4-1 ,suitable for nature time switch model swadeep -02 complete all as specified and directed by Engineer-in-Charge. Make :- Havells, Type: CN565T11*, Cat No. IHPAA065511* or equivalent BCH, L&T, CG , Siemens.
S&F in repair contactor 95 Amp single Phase , 240 V , as per IS 13947-4-1 ,suitable for nature time switch model swadeep -02 complete all as specified and directed by Engineer-in-Charge. Make :- BCH or equivalent in L&T, CG , Siemens.
S&F in repair contactor 32 Amp 3 phase, 415 volts as per IS 13947-4-1 ,suitable for nature time switch model swadeep -02 complete all as specified and directed by Engineer-in-Charge. Make :- BCH or equivalent in L&T, CG , Siemens.
S&F in repair Street light timer panel, single phase with maximum load of 12 Kw with inbuilt astronomical time switch, 65 Amp contactor, 63 Amp SPN confirming to IS/IEC/604947-4-1, FRLS internal wiring, with IP 54 protection and inbuilt short circuit protection. All as specified and directed at site. Make : Havells, HSN Code 8537, Cat Part No IHXSS0312A or equivalent in CG, C&S, Phillips
M & L in replacement DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 Sqmm 2/4 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut ,bolts and including provn for fixing 01 no of single pole MCBs 6-32 amps,10KA and MCB TPN 6-32 amps, 10 KA, ‘B’ series = 01 No inside the box complete all as specified and directed. Make :- Sintex/Hensel/standard or equivalent.
S&F in repair LED driver 75 watt, single Phase , 240 V , make : Crompton cat part No, X075C070V107FNY1BO or equivalent in C&S, Havells, Phillips for LED street light fitting complete all as specified and directed by Engineer-in-Charge.
S&F in repair LED driver 45 watt, Phase , 240 V , make : Crompton Cat part No. S0DQL-65-700-45W or equivalent in C&S, Havells, Phillips for street light fitting complete all as specified and directed by Engineer-in-Charge.
S&F in repair LED driver 25 watt, single Phase , 240 V , make : Crompton Cat part No. S0DVES-36-600-25W or equivalent in C&S, Havells, Phillipsfor LED street light fitting complete all as specified and directed by Engineer-in-Charge.
S&F in repair surge protection device compatible with outdoor LED fixture, make : Crompton, Cat part No.SRPS-HP-5K-440 or equivalent in C&S, Havells, Phillipsfor LED light fitting with rated power up to 75W complete all as specified
Supply and fixing 1100 volt grade heavy duty cable PVC insulated solid aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed on Highmast pole connectiuons, for external connections, PVC conduit of 15mm to be used, duly binded to the pole twin core cable flat or circular of size 6 Sqmm all as specified. Make:- Plaza /Havells/Grandlay
Supply only PVC insulated multistrand Copper Cable 3 core size 1 sq mm for bldg/security light fittings connections.
Supply and fixing MCCB 250 Amp 4 pole 25 KA with thermal magnetic release setting with 100% Icu complete all as specified and directed. Make;- Legrand catpart No 4202 19/ Siemens/ Schneider or equivalent
S&F in repair electronic ballast for 36 W/40W fluroscent tube light street light fittings. Make: Havells Cat Part No. LHBF28904025, C&S, Crompton, Phillips or equivalent.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface, complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming excavated hard/soft soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested, complete all as specified and directed.
Removing excavated surplus materials obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
Material and labour for clean dry sand in trenches/ducts for cushioning to cable, complete all as specified and directed. (Note. Punned depth of sand shall be measured for payment purpose.)
Supply and laying burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable, complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundation of stay assembly etc including necessary form work, complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles, including necessary form work finishing even and smooth without using extra cement, complete all as specified and directed. Note:- Dismantling of broken coping on existing pole shall be done by contractor and quoted rate shall be deemed to be included.
Supply only Insulation electric tape roll 20 mm 25 mtr long complete.
Taking out and Supplying, Laying and Jointing testing and commissioning cable PVC insulated and PVC sheathed armored XLPE cable LT 1100 grade heavy duty with 10 Sqmm 2 core, Stranded aluminum conductor through pipes in ducts. Poles/ trenches incl fixing of aluminium lugs, making good to disturbed surface etc for the following cross sectional area complete and specified as directed by EIC :-
Taking out and Supplying, Laying and Jointing testing and commissioning cable PVC insulated and PVC sheathed armored XLPE cable LT 1100 grade heavy duty with 16 Sqmm 2 core, Stranded aluminum conductor through pipes in ducts. Poles/ trenches incl fixing of aluminium lugs, making good to disturbed surface etc for the following cross sectional area complete and specified as directed by EIC :-
M&L for Painting of single LT steel tubular, structure including. cleaning and scrapping the old surface and then applying two coat of aluminium synthetic enamel paint over a coat of red oxide primer on all steel structure mounted on pole viz. Cross Arms , Clamps, bolts, nuts, brackets etc. and including painting of pole/ structure ith two coat of synthetic black & yellow enamel paint strip 300 mm wide alternative from bottom to upward of LT pole up to height of 1.5 mtr above the embedded portion of GL and writing pole number balance portion of pole shall be painted with two coats of Aluminium enamel paint over a coat of red oxide primer, complete the following as specified and directed :- Notes: - (i) Pole will be cleaned with steel brush to remove old unserviceable paint or scrapped complete surface. (ii) All poles will be numbered all as directed at site. (iii) If painting of poles not properly and not satisfied by JE/Engr-in-charge shall not be paid to contractor or otherwise repaint without extra cost.
M & L for prunning of tree branches of any sizes and dia, not less than 2 Mtr around the LT /HT OH line which obstructing the power supply/ maintenance of electric supply as well as illumination in area including repair of damage broken ACSR conductor, GI wire and jumpers and disposed exc 50 mtr away clearing area and testing of line, complete all as specified and directed. Note : (i) Span length is aproximate 40 to 50m. (ii) Rate quoted are inclusive of repair to damage work in item.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interior dimensions in PCC 1:2:4 type B1 RCC cover with GI frame, charcoal dust and common salt 15cm in layers all round the earth plate, 20mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified as per electric plate No 3of SSR 2009 including testing after completion.
S&F in replacement of solar LED light 20 W, 2 days back up, all in one stand alone light without mounting pole all as specified and directed
SHRI RAM ENTERPRISES
M/S VIJAY SINGH
CHAUHAN ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .