Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAdmitted-Finance GRAM AEMANPUR DISTRICT BULANDSHAHR UTTAR PRADESH | BULANDSHAHR | BULANDSHAHR | UTTAR PRADESH | ₹9.8 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical 133 131 | GORAKHPUR | UTTAR PRADESH | 273001 | - | - | Rejected-Technical All Pre Qualifying Condition Not Fulfilled |
| Sl No | Description | Qty | Unit | SINGH ENTERPRISES L1 | SINGH ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site within municipal area. | |||||
| 1.01 | 33 KV VCB 800 Amp. 750 MVA | 1 | No. | 5,000 ₹5,000 | 3,000 ₹3,000 |
| 1.02 | 33 KV Control Pannel single circuit Transformer | 1 | No. | 2,000 ₹2,000 | 3,000 ₹3,000 |
| 1.03 | 33KV Current Transformer 200/100/1 | 3 | No. | 1,000 ₹3,000 | 3,000 ₹9,000 |
| 1.04 | 11 KV Incoming VCB 600/300/5A, 350 MVA | 1 | No. | 2,500 ₹2,500 | 3,000 ₹3,000 |
| 1.05 | 11 KV Out going VCB 200/100/5A, 350 MVA | 2 | No. | 500 ₹1,000 | 3,000 ₹6,000 |
| 1.06 | 11 KV VCB Bus coupler, 350 MVA | 1 | No. | 500 ₹500 | 3,000 ₹3,000 |
| 1.07 | 11 KV 3x300mm2 XLPE Cable | 160 | Mtr. | 50 ₹8,000 | 11 ₹1,760 |
| 1.08 | 11 KV 3x300mm2 Outdoor Termination Kit | 2 | No. | 500 ₹1,000 | 180 ₹360 |
| 1.09 | 11 KV 3x300mm2 Indoor Termination Kit | 2 | No. | 500 ₹1,000 | 140 ₹280 |
Tender Value
₹11.4 L
EMD Value
₹11,430
Closing Date
20 Sept 2025, 1:00 pmClosed
S.E, EUCC-V, LESA, Amausi Zone,Lucknow
Room No.61, LESA Bhawan Near Residency park, lucknow
12/EUCC-V/LESA/2025-26
2025_MVVNL_1070692_1
12/EUCC-V/LESA/2025-26
Open Tender
Electrical Works
45 days
33/11 kv s/s Rajnikhand
As per tender Specification
2 documents required · 2 mandatory
₹3,540
A/c. No. 10101985364, IFSC CODE No.SBIN0003347,SBI
₹11,430
24 Sept 2025
2 Sept 2025
20 Sept 2025
2 Sept 2025
20 Sept 2025
2 Sept 2025
Amount
Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site within municipal area.
33 KV VCB 800 Amp. 750 MVA
33 KV Control Pannel single circuit Transformer
33KV Current Transformer 200/100/1
11 KV Incoming VCB 600/300/5A, 350 MVA
11 KV Out going VCB 200/100/5A, 350 MVA
11 KV VCB Bus coupler, 350 MVA
11 KV 3x300mm2 XLPE Cable
11 KV 3x300mm2 Outdoor Termination Kit
11 KV 3x300mm2 Indoor Termination Kit
11 KV 3x185mm2 XLPE Cable
11 KV 3x185mm2 Outdoor Termination Kit
11 KV 3x185mm2 Indoor Termination Kit
33 KV 3x300sqmm XLPE cable
33 KV Jointing Kit Outdoor 3X300sqmm XLPE Cable.
33 KV Lightening Arrester
33 KV Bus Isolator
Battery charger 24 Volt
Battery set 12 Nos. x2 Volts ,200Ah
ACSR Panther Conductor for Bus Bar
ST pole 11 mtr long
M.S.Angle 65x65x6 sq mm
Polymeric 11KV Pin Insulator
M S Earthing Rod 240x20 mm
11 kv pin with nut
1x240 LT XLPE Cable
MS Channel 125x65mm 3.5m long 4 Nos Pieces [email protected] Kg. Mtr. With wastage
MS Angle 75x75x6, 2.6M 2 Nos Total [email protected] Kg./M with wastage
MS Channel 125x65mm 3.5m long 2 Nos. 7M @ 13.1 Kg. Mtr.
MS channel 100x50 mm
Rail 105 Lb 8 MTR. LONG
Earthing of substation Switchyard.
Supply of MS Round Bar 32 mm dia (6.21 Kg. per mtr.) for laying of main earth mat in extantred switchyard & pannel earthing Bridge 160 ckt. Mtr.
Supply of MS Round Bar 32 mm dia (6.21 Kg. per mtr.) for making M.S. Earth electrod 32x3000 mm (14no.x3.0mtr.)
Earthing of substation Switchyard complete by round bar 32 mm dia exavation of earth for laying of earth mat 750mm deep and proper leveling after laying of earth mat Complete (10mtr.x15mtr.) as per specification and connecation of all switchyard equipment by GI Flat 50x6 mm (The contractor shall arrange all material )
Cutting ,fabrication and driving of earth electrode of size 32x3000 mm
Cutting shaping, laying and welding of riser strip size 50x6mm G.I strip of size 50x6 mm in between earth mat and equipments /structure/body of T/F for earthing (two nos Riser for each structure equipment individually GI strip shall be provided contractor )
Earthing of Indoor Equipment by making of 2 Nos. Quard of round bar 32 mm dia as per norms.
Fabrication & Erection of cable stand made of two nos MS channel 100x50x3 mtr. Long jointed to each other by means of 05 nos MS strip 50x6 mm of size 150 mm Long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamp also.(All materials will provide by contractor except MS channel).
Painting of all structures equipment Newly Constructed only
Construction of Power T/F plinth suitable for 33/11KV 5 MVA power T/F of size 4x3x1.3 having 0.4 mtr height above ground level. The work includes excavation of foundation base concreting in cc ratio 1:6 M as 12 1st class brick work in ratio 1:4 with coarse sand ,foundation cc in ratio 1:4:8 using M.S bar of 12 mm dia for reinforcement the work includes laying of 2 nos rail pieces 4 mtr long as per drawing/practice the plinth shall be finished in all respect. (only rail piece and M.S angle provided by the department)
Construction of masonry type plinth for 33KV VCB of size 1.6x1.6x1 M brick, sand, cement and stone grit including grouting of 4 Nos foundation Bolts for erection of 33KV VCB.
Fabrication & erection of 11 KV cable exposure type double pole with the provission of cable with fixing of necesory clamps and other acessories like danger board,number plate,barbed wire,2 no. channels 100x50 mm (1600mm each),1 no.MS channel 100x50mm(3200mm in length) for supporting the hoisting of cable & poles.its jumpering by single core PVC aluminium cable with proper size Al.lug after making three phase busbar with help of 11 KV pin,pin insulator and PVC cable. (all material arranged by contractor except steel,pole & insulator).as per RESPO norms.
Isolator Structure-Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of M.S channel 125x65 mm two pieces of M.S channel joined to each other by M.S flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. Grouting of Isolator structure in CC (cement ,coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting os structure complete.(only M.S channel and angle provided by the deptt)
Lightning Arrestor/ CT structure : - Fabrication of lightning arrestor/CT structure as per RESSPO drawing with the help of 2 nos M.S channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect.
Erection of structures, grouting, plinthing of ALL structures equipment.
Mounting of accessories/equipment on fabricated structure complete work with making proper alignment and tightening the work includes fabrication work if required for proper operation of equipment .
33 KV VCB
33 KV lightning Arrestors
Bus/Line Isolator
Fabrication & Erection of Neutral Stand structure with foundation
Commissioning and Testing of 5 MVA T/F & Control cable laying & Termisnation by using cable gland & Lugs
Jumpering complete T/F bay with ACSR panther Cond. and required "L" clamp with nut & Bolts from 33 KV existing bus bar & 33 KV cable to T/F (with copper L piece) other all required work. ( Except Panther Conductor all required material provided by Contractor.)
Laying of Double circuit 11 KV 3x300 sq mm XLPE cable in normal soil/allready Constructed trench/As per Site Condition by digging of suitable size of trench as per site condition cable should be covered by bricks and sand with cleaning of Existing Trench.
Hoisting, jumpering, clamping of 11KV 3x300 sq mm XLPE cable on cable stand, panel with proper taping with the help of empire tape. PVC tape and connectors.
Hoisting of 11KV 3X185 sqmm XLPE cable on double pole with MS pipe/GI pipe of size 5/6" dia 3 M long including its jumpering complete with clamps, nuts and bolts(all material arranged by contractor).
Laying of Single circuit 11 KV 3x185 sq mm XLPE cable in normal soil/already Constructed trench/As per Site Condition by digging of suitable size of trench as per site condition cable should be covered by bricks and sand with cleaning of Existing Trench.
Hoisting, jumpering, clamping of 11KV 3x185 sq mm XLPE cable on 11 KV panels with proper taping with the help of empire tape. PVC tape and connectors.
Construction of Control cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S strip at the interval of 0.30 M and M.S angle at both the edge of the trench.
Construction and fixing of trench cover0.5 M wide 0.75 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench150 mm wide with provision of M.S Angle as per RESPO Norms
Supply & Laying of copper control cable of following sizes its proper dressing ,ferruling and connection with the system as per Site Condition with cleaning of Existing Trench. ( all the material shall be provided by contractor) as per norms
Copper Control Cable 2x2.5 Sq. mm.
Copper Control Cable 4x2.5 Sq. mm.
Pipe boring type earthing minimum 20 mtr deep from ground level or upto water level with B class G.I. pipe 2 " dia. Connection of equipment with earthing by GI strip 50x6 mm included in the job as per specification/norms for power transformer, VCB, CT/LA and other. (All materials will be Provided by contractor)
PG Clamp Panther to Panther
Dragging of following panels (Control and feeder pannel) from unloading place upto control room and placement erection and grouting, commissioning & testing of the same as per RESPO Norms
33 KV T/F Control panel
11 KV Bus coupler, 350 MVA
11 KV Incoming VCB 600/300/5A
11 KV Out going VCB 200/100/5A
Grouting,Plinting and Painting of new erected 11M long ST poles of single pole support,double pole cable exposures and end type poles of 33 KV lines
Digging of Pit in kachcha/Pakka land in depth upto 1/6 length of Pole, Dragging of STP from near by place/Dump, Erection of Single pole along with stone pad in bottom with proper alignment of line for 33 KV line on 11 M long ST Pole and 11 mtr. PCC Pole refilling with ramming of earth.
Grouting of pole in depth of 1/6 the length of pole in ratio 1:4:8 in cement sand and brick balast as per RESPO norms.
Construction of pole plinth 300mm x 450 mm above ground level in 1:2:4 in cement, coarse sand and stone gritt as per RESPO norms.
Painting of new erected ST pole with two coat of red oxide paint,PO red paint at top of pole 2 M & balance by two coats of best quality aluminium paint ISI of Burger/Nerolac/Asian mark as per norms.
Supply of following auxiliary material
Rabber mat 2x1.5 Mtr.
Erection of 24 V batteries set with charger including stand (except 24 V batteries set with charger all the material & stand shall be provided by contractor) & initial charging complete set.
High Pressure Testing
Dismantling of fencing & toe wall 20 mtr. & Refixing of fencing & toe wall 4 mtr
Shifting of Capacitor Bank with structure Isolator & Cable stand
Return balance material to LESA store daliganj and other work in site area
SINGH ENTERPRISES (BID ID -5547610)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid