Executive Engineer STD Udhampur
Udhampur
Attached
2025_PDD_298117_1
19
Open Tender
Electrical Works
Turn-key
90 days
Batote
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer , STD Udhampur
₹80,000
8 Jan 2026
13 Dec 2025
5 Jan 2026
13 Dec 2025
3 Jan 2026
13 Dec 2025
SITC FOR AUGMENTATION OF POWER TRANSFORMER AT 33 KV LEVEL FROM 3.15 to 6.3 MVA At Khari
33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ)
11 kV 3- Core XLPE 400 mm² armoured, FRLS
Installation, Testing,and Commissioining of 6.3 MVA 33/11kV, 3 phase ONAN, Copper wound, Out-door Type,Power Transformer, Oil Filled with OLTC and all accessories including HT and LT Terminal connections as per latest IS Standards. (efficiency level 2)
Transportation of spare 6.3 MVA Power Transformer from Banihal Receiving. Station to Receivining Station Khari.
Earthing of Power Transformer ( Improvement/Strengthening works)
GI Chainlink Fencing of 33 kV Yard of Substation by way of Mass Concrete in Foundations and chainlink fencing of 6 ft height with MS angle 56 x 65 x 6 mm Posts
Construction of Bathroom of size 8 ft * 6 ft includind all allied works like centre fitting,all centre fitting accessories,illumination and marble/ceramic tiles in floor/all walls.
Providing and placing of Terrace Polythylene Water Tank IS 12701 marked with cover and suitable locking arrangement and make necessary holes for inlet,outlet and overflow pipe.( capacity 1000 ltrs)
Construction of Under ground Water tank and 1 no Septic Tank (8 ft * 6 ft * 6 ft)
Erectionof Main gate MS steel ( 15 ft wide* 5 ft ht)along with RCC columns( complete job)
Dismantling of existing 3.15 MVA power Transformer and wite back of the same to Divisional Store .
SITC FOR AUGMENTATION OF POWER TRANSFORMER AT 33 KV LEVEL FROM 3.15 - 6.3 MVA AT Sangaldan
Installation, Testing,and Commissioining of 6.3 MVA 33/11kV, 3 phase ONAN, Copper wound, Out-door Type,Power Transformer, Oil Filled with OLTC and all accessories including HT and LT Terminal connections as per latest IS Standards. (efficiency level 2)
Transportation of spare 6.3 MVA Power Transformer from 33/11 KV Dhar Road Receiving Station to Receiving Station Sangaldan.
Earthing of Power Transformer ( Improvement/Strengthening works)
33kv C&R Panel along with O/C, E/F relays , mimic diagram, Voltmeter, Ammeter, Annunciation windows with annunciation relays, 3-Phase Tri-Vector Smart meter- % amps, DLMS Compliant including earthing. Make Megawin, Crompton Greaves Pascal, Stelmec, Yamuna ,etc .
33 kV Isolator with Earthing Blade (36kV,1250A, Outdoor, 3 poles, 25 kA)
33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ)
11 kV VCB Panel Board Set (12 kV, 1250A, 25 kA, Indoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector smart meter -5 Amps, DLMS Compliant with RS-485 port SCADA Compatible etc MAKE :- Seimens, Megawin, BHEL, Electricfield, Pascal, Stelmec. Yamuna ,etc . (1+1)
11 kV 3- Core XLPE 400 mm² armoured, FRLS
Dismantling of existing 3.15 MVA power Transformer and wite back of the same to Divisional Store .
Compatibility Report for DhunaBOQ.xls
Run on 10-07-2021 14:05
The following features in this workbook are not supported by earlier versions of Excel. These features may be lost or degraded when you save this workbook in an earlier file format.
Significant loss of functionality
Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear clipped.
Minor loss of fidelity
Some formulas in this workbook are linked to other workbooks that are closed. When these formulas are recalculated in earlier versions of Excel without opening the linked workbooks, characters beyond the 255-character limit cannot be returned.
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
SBDCombinedBatote.pdf
Tender Documents • 7.49 MB
BOQ_966271.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .