Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.7 LAccepted-AOC 4 13A PERIYAR NAGAR THANGAMAPURIPATTINAM METTUR DAM 636 402 | SALEM | TAMIL NADU | 636402 | ₹8.7 L Quoted ₹7.5 L | 1 | Accepted-AOC L1 |
| 2 | 2₹7.7 LRejected-AOC NO 42 PERIYAN NAGAR THANGAMAPURIPATTINAM METTUR DAM 636 402 | METTUR DAM | SALEM | TAMIL NADU | 636402 | ₹7.7 L | 2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | ANNAI ENTERPRISES L1 | T S CONTRACTOR L2 |
|---|---|---|---|---|---|
| 1.00 | Transportation of valve from central store to site
Transporting the valves and pipes from central store to Unit-II repair bay and repair bay to work spot. | 1 | No | 8,190 ₹8,190 | 8,200 ₹8,200 |
| 2.00 | Labour charges for IBR Welding for replacement of ES-3/4/5 size 200 mm/250 ATA/MO/NRV pipeline of size OD 219.1x6.35mm thick | 25 | joints | 4,430 ₹1.1 L | 4,500 ₹1.1 L |
| 3.00 | Stress Relieving charges for newly welded ES-3 & ES-4 valve welding joints of pipe size: OD 219.1 X 6.35 mm thick | 6 | joints | 13,980 ₹83,880 | 14,050 ₹84,300 |
| 4.00 | Labour charges for IBR welding for replacing the existing defective valve MC-29, MC NRV Deaerator floor size of GV 300/16 ATA/BW/MO / pipe dia 323.9 x 6.35 | 38 | joints | 4,430 ₹1.7 L | 4,500 ₹1.7 L |
| 5.00 | Cutting and Welding of GLV 1"/1500/ 2500 class valves or equivalent joints by IBR Welder.
Charges for cutting the defective 1" valve or equivalent 2 Nos 1" joints in drain / vent line, grinding and welding the new valve in the line by IBR welder. | 40 | joints | 2,120 ₹84,800 | 2,200 ₹88,000 |
| 6.00 | Labour charges for replacement of valves, pipes, stubs, bends and Reducers by Non IBR welding works.
Replacing the defective drain line valves or equivalent in Heater drip, condenser air, Auxiliary steam, and drain water lines etc by Non IBR welder. | 152 | joints | 1,525 ₹2.3 L | 1,600 ₹2.4 L |
| 7.00 | Labour charges for replacing the defective drain line valves or equivalent in Cooling water lines and ACW lines by Non IBR welder.
(ERW pipe, reducer & bends) Rate for Two number Non IBR cutting and welding) | 20 | joints | 1,525 ₹30,500 | 1,600 ₹32,000 |
| 8.00 | Cost of welding electrodes for IBR welding. Electrode: E 9018 B3 (For Item Sl.No:2) | 455 | Nos | 9.88 ₹4,495.40 | 10 ₹4,550 |
| 9.00 | Cost of welding electrodes for Non-IBR welding.
Electrode : E7018 –A1 (ARC) (For Item Sl.No:4) | 1,330 | Nos | 7.25 ₹9,642.50 | 8 ₹10,640 |
| 10.00 | Cost of welding electrodes for (ERW) Non-IBR welding. Electrode : E 6013 (For Item Sl.No:5) | 140 | Nos | 3.1 ₹434 | 3.5 ₹490 |
Tender Value
Refer Docs
EMD Value
₹8,400
Closing Date
1 Dec 2025, 2:00 pmClosed
Superintending Engineer /Mechanical-I/MTPS-I
Office of the Superintending Engineer / Mechanical -I Mettur Thermal Power Station- I Mettur Dam-636406
MTPS I TM UNIT II Transporting the valves from central store Replacing the defective Extraction steam to HP Heaters 5 6 isolation valves ES 5 ES 6 MC 29 MC NRV Deaerator floor BFP Suction valves 2C CA 24 eroded drip line reducers
2025_EB_624019_1
CE / MTPS-I / SE / M-I / TM / OT. 396 / 2025-26
Open Tender
Power/Energy Projects/Products
15 days
Mettur Thermal Power Station-I / Mettur Dam
As per the Tender Specifications
4 documents required · 4 mandatory
₹0
₹8,400
Yes
29 May 2026
17 Nov 2025
2 Dec 2025
17 Nov 2025
1 Dec 2025
17 Nov 2025
Amount
Transportation of valve from central store to site Transporting the valves and pipes from central store to Unit-II repair bay and repair bay to work spot.
Labour charges for IBR Welding for replacement of ES-3/4/5 size 200 mm/250 ATA/MO/NRV pipeline of size OD 219.1x6.35mm thick
Stress Relieving charges for newly welded ES-3 & ES-4 valve welding joints of pipe size: OD 219.1 X 6.35 mm thick
Labour charges for IBR welding for replacing the existing defective valve MC-29, MC NRV Deaerator floor size of GV 300/16 ATA/BW/MO / pipe dia 323.9 x 6.35
Cutting and Welding of GLV 1"/1500/ 2500 class valves or equivalent joints by IBR Welder. Charges for cutting the defective 1" valve or equivalent 2 Nos 1" joints in drain / vent line, grinding and welding the new valve in the line by IBR welder.
Labour charges for replacement of valves, pipes, stubs, bends and Reducers by Non IBR welding works. Replacing the defective drain line valves or equivalent in Heater drip, condenser air, Auxiliary steam, and drain water lines etc by Non IBR welder.
Labour charges for replacing the defective drain line valves or equivalent in Cooling water lines and ACW lines by Non IBR welder. (ERW pipe, reducer & bends) Rate for Two number Non IBR cutting and welding)
Cost of welding electrodes for IBR welding. Electrode: E 9018 B3 (For Item Sl.No:2)
Cost of welding electrodes for Non-IBR welding. Electrode : E7018 –A1 (ARC) (For Item Sl.No:4)
Cost of welding electrodes for (ERW) Non-IBR welding. Electrode : E 6013 (For Item Sl.No:5)
Cost of Cutting Gas for cutting the pipes, valves & bends wherever necessary (For Item Sl.No.2 & 4)
Consumables and Tools & plants for Item Sl.No:1 to 5
T S CONTRACTOR (BID ID -1520446)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
BOQ_746162.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid