Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC DUE TO L1 | |
| 2 | L2₹31.9 L+₹12.6 L (65.2%)Rejected-AOC | L2 | Rejected-AOC HIGHER RATE | |
| 3 | L3₹35.0 L+₹15.6 L (80.9%)Rejected-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-AOC HIGHER RATE | |
| 4 | L4₹41.0 L+₹21.7 L (112.2%)Rejected-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L4 | Rejected-AOC HIGHER RATE | |
| 5 | Rejected-Technical 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | Rejected-Technical Requisite category not held i.e. (c) (i) |
Tender Value
Refer Docs
EMD Value
₹80,400
Closing Date
14 Jul 2023, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI
NIT NO GE/ND-35/2023-24 REPAIR/MAINT OF SUBMAIN WIRING, DISTRIBUTION BOARD, LT PANEL, COOLING APPLIANCES, AIR CONDITIONERS, BUILDING SECURITY LIGHTS AND MISC WORKS AT CERTAIN BUILDINGS OF SP MARG MD OFFR ACCN AND ABHM OFFR ACCN UNDER GE NEW DELHI
2023_MES_603661_1
NIT No GE/ND-35/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NEW DELHI
REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE NEW DELHI
₹80,400
Yes
15 Jan 2024
16 Jun 2023
17 Jul 2023
16 Jun 2023
14 Jul 2023
30 Jun 2023
Amount
Disconncting,dismantling the exsiting LT panel Meter board of size 1500mmX1800mmX350mm,415 Volt,3 phase, 4 wire with bus bar 400 amp capacity from exsiting foundation after taking proper shut down and restoration of electric supply to quaters by necceasary arrangements as directed and keeping safe custody for re fixing back including connecting up all connections, new foundation,connecting up all dismantled connection and ensure proper electricsupply distribution to users DB after carry out the following repair works in panel.
S & F in replacement of Din rail for MCB SPN 63 Amps
Cutting the rusted out portion of the LT panel board and Welding with new sheets of thickness 2 mm including necessary fabrication at site not exceeding 1sqmtr and necessary painting etc.
Replacement of view glass for meter compartment.
complete painting with two coats of enamel paint by spray painting machine of approved colour with writing/making of connection details including Bldg no & respective quarter number ., danger sign board etc.
Reconnecting the sub mains 25 sqmm single core copper cable to the MCB's and MCCB's terminal with the help of copper lugs and thimbles and tightening properly in such a way that no leakage current found during site inspection.
Disconnecting,dismantling the existing LT panel Meter board for LIFT of size 600mmX1400mmX300mm with angle frame 50mmX50mmX6mm ,415 Volt,3 phase,4 wire with bus bar 400 amp capacity from existing foundation after taking proper shut down and restoration of electric supply to quarters by necessary arrangements as directed and keeping safe custody for re fixing back including connecting up all connections, new foundation, connecting up all dismantled connection and ensure proper electric supply distribution to users DB after carry out the following repair works in panel as directed by Engg-in-charge.
complete painting with two coats of enamel paint by spray painting machine of approved colour with writing/making of connection details including Bldg no & respective quarter number ., danger sign board etc.
Welding of rusted out sheets with new sheets of thickness 2 mm.(not exceeding 1sqmtr)
M & L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 metre below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 32x6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover etc.
M & L in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required 25X4 mm galvanized iron strip.
Supply and fixing in replacement at the place of old SFUs, MCCB- 4 pole-415 volt of capacity 250 amp, breaking capacity not less than 25 KA , Icu=100% Ics thermal magnetic type adjustable type 80 to 100 % confirming to IEC-60947-II, IS-13947-II , including thimbles, nuts, bolts ,washers etc and connections, replacement of thimbles, minor parts like nuts bolts washer etc. all as specified and directed by Engr-in-Charge Make : Legrand cat part No 420219 or equivalent Make in Schneider/L&T
Disconnecting mains connection and taking out old sub main wiring single core 6/10 sqmm and one single core 2.5/4/6/10 sqmm aluminum conductor cable from the concealed conduit from the wall/ceiling and making good to the disturbed surface all as specified.
M&L for sub main wiring with PVC insulated unsheathed copper conductor multi stranded FRLS type 1100V grade 2 x 6 sqmm complete drawn in new PVC conduit in surface wall and its accessories along with 1x 6 sqmm PVC insulated unsheathed copper conductor multi stranded FRLS type cable for continuous earth wire and duly connected to common earth dolly including taking out old unserviceable sub main wiring all as specified and directed. Note (i) Electrician having proper safety rope with safety belt/strap during sub main wiring for fixing PVC conduit along the bldg within the shaft. Note (ii) work includes chases cutting for laying of PVC conduit with ss clamp at every 0.60 meters &making good the desturbed surfaces including putty filling & oil bound emulsioned painting complete.
M&L for submain wiring with PVC insulated unsheathed copper conductor multi stranded FRLS type 1100V grade 2 x 10 sqmm complete drawn in new PVC fixed to wall conduit and its accessories along with 1x 10 sqmm PVC insulated unsheathed copper conductor multi stranded FRLS type cable for continuous earth wire and duly connected to common earth dolly including taking out old unserviceable sub main wiring all as specified and directed. Note (i) Electrician having proper safety rope with safety belt/strap during sub main wiring for fixing PVC conduit along the bldg. within the shaft Note (ii) work includes chases cutting for laying of PVC conduit with ss clamp at every 0.60 meters &making good the desturbed surfaces including putty filling & oil bound emulsioned painting complete
M&L for submain wiring with PVC insulated unsheathed copper conductor multi stranded FRLS type 1100V grade 2 x 4 sqmm complete drawn in new PVC fixed to wall conduit and its accessories along with 1x 4 sqmm PVC insulated unsheathed copper conductor multi stranded FRLS type cable for continuous earth wire and duly connected to common earth dollyincluding taking out old unserviceable sub main wiring all as specified and directed. Note (i) Electrician having proper safety rope with safety belt/strap during sub main wiring for fixing PVC conduit along the bldg. within the shaft . Note (ii) work includes chases cutting for laying of PVC conduit with ss clamp at every 0.60 meters & making good the desturbed surfaces including putty filling & oil bound emulsioned painting complete
S&F factory made sheet steel distribution boards, double door, SPN,12 way, concealed type, 240 volts AC with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing including taking out old unserviceable DB and making good surfaces of existing distrubed area all as specified.
S&F factory made sheet steel distribution boards, double door, SPN, 8 way, concealed type, 240 volts AC with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing including taking out old unserviceable DB and making good surfaces of existing distrubed area all as specified.
S&F factory made sheet steel distribution boards, double door, SPN,4 way, concealed type, 240 volts AC with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing including taking out old unserviceable DB and making good surfaces of existing distrubed area all as specified.
S&F in replacement MCBs 6-32 Amps, SP, 10 kA rupturing capacity 'B' curve and fixing in DBs all as specified
S&F in replacement MCBs 40-63 Amps, SPN, 10 kA rupturing capacity and 'B' curve fixing in DBs all as specified
S&F in replacement MCBs 6-32 Amps, SPN, 10 kA rupturing capacity and 'B' curve fixing in DBs all as specified
Material and labour for cleaning and painting to old steel surfaces of Desert cooler with two coats of synthetic enamel spray paint over one coat of red oxide on external surface & two coats of anti corrosive black paint inside the Body tank & side grills over a coat of Red Oxide primer including scraping/rubbing with wire brush on old surface of Desert cooler. complete all as specified and directed by engineer-in-Charge
S&F in replacement Desert Cooler fan motor capacity 1/5 HP, 1400 RPM single phase with fan blade and stand complete.
S&F in repairs capacitor 4 MFD for fan motors of desert coolers.
S&F in replacement PVC insulated and PVC sheathed cable copper conductor 3 core (superior quality) complete.
S&F in replacement water lift pump plastic body of 220-240 Volts AC Supply single phase complete all as directed by Engr- in-Charge .
S & F in repairs desert cooler body of size 60x55x65 cm made out of GI sheet & water storage tank of soze 65x55x20 cm deep made out of GI sheet including front grills & three side shutters duly fitted with wood pads 03 nos & duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer (inside & outside) all as directed by Engr-in-charge.
Labour for checking and attending complants of ductable split type ACs, water cooler Refrigetors etc of any capacity, rectification minor defects and make the equipment functional complete all as specified and directed.(any parts required for replacement shall be measured and paid separately under respective items) Note:- (a) The contractor should detail minimum one AC Mechanic & one helper to attend complaints in kashmir House . (b) The complaint should be attended on same day.
Servicing of package type AC 4 Ton capacity complete with blower motor dismantling all parts and refixing after cleaning and replacement of defective parts, dismantling the cover of condensing coil carefuly and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade throughly with the help of descaling chemical, brush, water and dry properly including using air blower for cleaning air dust deposited on the equipment and re-fixing the same after repair complete all as specified. Note:- Spare parts shall be measured and paid separately.
M&L for taking down existing unsv compressor and fixing in replacemnt new hermetically sealed compressor suitable for 4 Ton capacity pacakge type refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge, Make: Kirloskar/Tecumsheh/Copeland/Danfoss/existing make AC's complete all as specified.
Supply & charging the gas refrigerant R-22/R 410 A or as existing No to package type AC's of capacity 4 Ton capaity including removing of leakage if any and testing complete all as specified & directed.
M&L for taking down of inverter type PCB and transporting it to authorized workshop for its repair complete along with necessary accessories like diodes, resistors, capacitors for PCB card suitable for package type AC's of capacity 4 Ton complete all as specified and as directed by Engr-in-Charge.
M&L for taking down existing unsv condensing coil from Deep freezers of any capacity and replacement by new Condensor coil as per existing capacity upto 500 Ltrs including brazing and dehydration by creating vaccuum for more than 24 Hrs so that no oil/sludge remains in the cooling coil/system. Complete all as specified and as directed by Engr-in-Charge.
Servicing of package type ice cube machine 140 Kg/24 hours (with inbuilt bin) capacity complete dismantling all parts and refixing after cleaning and replacement of defective parts, dismantling the cover of condensing coil carefuly and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade throughly with the help of descaling chemical, brush, water and dry properly including using air blower for cleaning air dust deposited on the equipment and re-fixing the same after repair complete all as specified. Note:- Spare parts shall be measured and paid separately.
S & F In repair/ replacement of PVC ice thickness probe including taking down old unserviceable all as directed by Engr-in- Charge
S & F In repair/ replacement of double fold water valve hydraulic type including taking down old unserviceable all as directed by Engr-in- Charge
S & F In repair/ replacement of ice cube machine drain valve industrial type size 15mm including taking down old unserviceable all as directed by Engr-in- Charge
S & F In repair/ replacement of ice cube machine spray arm for metal boby including taking down old unserviceable all as directed by Engr-in- Charge
Supply & fix in replacement of factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way VTPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete and including taking out old U/S DB , cutting chases and making good to walls all as specified.
Supply fix in replacement of MCCB TPN 160 Amp, 36 kA micro processor energy released type with OLED display complete ncluding taking out old MCCB all as specified.
Supply & fix in replacement of factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 4 way VTPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete and ncluding taking out old U/S DB , cutting chases and making good to walls all as specified.
S & F In repair/ replacement of ice cube machine fiber timer size 15mm 220 volt single phase including taking down old unserviceable all as directed by Engr-in- Charge.
M&L for replacement of inverter type PCB indoor or out door unit in existing make complete along with necessary accessories and suitable for package type AC's of capacity 4 Ton complete all as specified and as directed by Engr-in-Charge.
M & L for servicing of Split type/window type AC of capacity 1.5 /2 TR of any by cleaning of filter on front side including fins, checking of refrigerant standing pressure, topping of refrigerant upto the required level, complete all as directed by Engineer-in-Charge. Note : Refrigerant required for topping (R22 /407a) shall be measured and paid for separately
Replacement of following unserviceable item in split type AC :- a) Blade for condensing fan motor of capacity 1.5 /2.0 TR
b) Condensing fan motor of capacity 1.5/2.0 TR
S&F in repairs blower fan motor split type AC of1.5/2.0TR capacity of make Carrier / Hitachi / Voltage / Blue star, all as directed by Engineer-in-Charge.
S & F in repairs starting capacitor, for split type AC of capacity1.5/2.0TR. Complete all as directed. Make : EPCOS /ASIAN /Sarada
S&F in repairs Rotary type Compressor (Sealed Unit) of split type air conditioner of capacity 1.5/2.0 TR, Single phase220 volt of existing make necessary modification of foundation as required to suit the compressor, vacumisation, pressure testing, leakage rectification complete to taking down old unserviceable compressor the entire satisfaction of Engr-in-charge.
S&F in repairs scroll type Compressor (Sealed Unit) of water cooler40/80 ltr capacity single 220 volt of existing make including necessary modification of foundation as required to suit the compressor, vacumisation, pressure testing, leakage rectification testing complete to taking down old unserviceable compressor the entire satisfaction of Engr-in-charge.
Supply and filling of Refrigerant gas R 22/ R-134/ R-410(a) in company sealed cylinder of capacity all as directed by Engr-in-charge
S&F in repairs and replacement wall mounted indoor Voltage Stabilizer automatic operation single phase and designed for input variation between 170 V to 250 Volt with output voltage stabilized at 230 V with accuracy of +2.5% and of capacity 4 KVA.
S & F in replacement of indoor unit 1.5 /2.0 TR capacity as per existing makes and sizes complete all as specified and directed by Engr -in- charge
S & F in repairs PCB Senser unit split AC indoor unit of Capacity 1.5 /2 TR suitable for , existing removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as directed by Engr in Charge.
S&F Metal clad enclosure with plug and socket 20 Amp with one MCB single pole, 20 Amps 240 volts. all as specified.Make:Legrand/Havells/Indoasian
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm including suitable cable gland/lugs/thimbal fixing at surfae of wall/floor all as directed by Engr-in-Charge.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 3.5 core 95 sq. mm including cable gland/lugs/thimbal fixing at surfae of wall/floor all as directed by Engr-in-Charge.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional 3.5 core 120 sq. mm including suitable cable gland/lugs/thimbal fixing at surfae of wall/floor all as directed by Engr-in-Charge.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 3.5core 70 sq. mm including cable gland/lugs/thimbal fixing at surfae of wall/floor all as directed by Engr-in-Charge.
M&L in replacement building security LED 18 watt fitting complete with accessories made of aluminum housing having minimum system efficiency 100 lm/watt operating at full load at AC supply including house service bracket complete all as specified and directed.
Material and labour for bracing supporting, clamps and back plates frabcated from structural steel section incl nut, bolts, washers, welding, bending cold or hot drilling holes for bolts including the fixing of cable tray from pannel to the nearest side wall, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint.
M&L in repair/replacement of inverter type LED street light 90 watt fitting complete with accessories complete all as specified and directed.
J B Electricals
RUCHIKA ENGG.WORKS
SNOWY ENGINEERING INC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .