| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply & install, testing and commissioning of factory made,CPRI approved factory made LT panel outdoor KIOSK type with double doors of suitable size provided with locking arrangements dust, weather and vermin proof 1100 volt grade, 50 Hz AC made out by 3.15 mm thick CRCA sheet steel, fully compartmentalised, with IP-65 protection all as per conforming to IS: 2417 of 1962 complete with and 50x50x5 mm thick angle iron for frame and legs, 04 Nos. legs 750 mm long 450 mm grouted in PCC blocks of type B-1 (1:2:4) with 300 mm ground clearance, for 415 volts, 3 phase, 4 wire AC supply complete all as directed with and including the following
(a) MCCB 4 pole 415 Volt, 630 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 35 KA - 01 No (incoming)
(b) MCCB 4 pole 415 Volt, 250 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 25 KA - 04 No (outgoing)
(c) MCCB 4 pole 415 Volt, 125 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 16 KA - 02 No (Outgoing) | 4 | Each | - | - |
| 1.01 | (d)Digital street light Timer Switch with contactor 40A - 01 Nos
(e) Digital Voltmeter 96 sqmm 0 - 500V with selector switch - 01 No
(f) Digital Ammeter 96 sqmm 0 - 200 Amp with CTs and selector switch - 01 No
(g) Aluminium strip bus bars with colour code PVC insulation 800 Amps capacity - 01 Set
(h) Indicators RYB - 01 Set
(j) Earthing terminals and cable glands.
(k) Internal wiring of panel board with solid coductor copper cable single core of sutable size and incl 03 Nos bakelite control fuses.
[l] Danger notice plate for LT with conventional skull and bones duly rivetted/pasted to the panel board door. | - | - | - | - |
| 2 | Supply & install, testing and commissioning of factory made,CPRI approved factory made LT panel outdoor KIOSK type with double doors of suitable size provided with locking arrangements dust, weather and vermin proof 1100 volt grade, 50 Hz AC made out by 3.15 mm thick CRCA sheet steel, fully compartmentalised, with IP-65 protection all as per conforming to IS: 2417 of 1962 complete with and 50x50x5 mm thick angle iron for frame and legs, 04 Nos. legs 750 mm long 450 mm grouted in PCC blocks of type B-1 (1:2:4) with 300 mm ground clearance, for 415 volts, 3 phase, 4 wire AC supply complete all as directed with and including the following
(a) MCCB 4 pole 415 Volt, 400 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 35 KA - 01 No (incoming)
(b) MCCB 4 pole 415 Volt, 200 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 25 KA - 02 No (outgoing)
(c) MCCB 4 pole 415 Volt, 125 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 10 KA - 02 No (Outgoing)
(d) MCCB 4 pole 415 Volt, 63 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 25 KA - 04 No (Outgoing) | 4 | Each | - | - |
| 2.01 | (e)Digital street light Timer Switch with contactor 40A - 01 Nos
(f) Digital Voltmeter 96 sqmm 0 - 500V with selector switch - 01 No
(g) Digital Ammeter 96 sqmm 0 - 200 Amp with CTs and selector switch - 01 No
(h) Aluminium strip bus bars with colour code PVC insulation 800 Amps capacity - 01 Set
(j) Indicators RYB - 01 Set
(k) Earthing terminals and cable glands.
(l) Internal wiring of panel board with solid coductor copper cable single core of sutable size and incl 03 Nos bakelite control fuses.
(m) Danger notice plate for LT with conventional skull and bones duly rivetted/pasted to the panel board door. | - | - | - | - |
| 3 | Supply & install, testing and commissioning of factory made,CPRI approved factory made LT panel outdoor KIOSK type with double doors of suitable size provided with locking arrangements dust, weather and vermin proof 1100 volt grade, 50 Hz AC made out by 3.15 mm thick CRCA sheet steel, fully compartmentalised, with IP-65 protection all as per conforming to IS: 2417 of 1962 complete with and 50x50x5 mm thick angle iron for frame and legs, 04 Nos. legs 750 mm long 450 mm grouted in PCC blocks of type B-1 (1:2:4) with 300 mm ground clearance, for 415 volts, 3 phase, 4 wire AC supply complete all as directed with and including the following
(a) MCCB 4 pole 415 Volt, 400 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 35 KA - 01 No (incoming)
(b) MCCB 4 pole 415 Volt, 250 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 25 KA - 03 No (outgoing)
(c) MCCB 4 pole 415 Volt, 125 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 10 KA - 02 No (Outgoing) | 4 | Each | - | - |
| 3.01 | (d)Digital street light Timer Switch with contactor 40A - 01 Nos
(e) Digital Voltmeter 96 sqmm 0 - 500V with selector switch - 01 No
(f) Digital Ammeter 96 sqmm 0 - 200 Amp with CTs and selector switch - 01 No
(g) Aluminium strip bus bars with colour code PVC insulation 800 Amps capacity - 01 Set
(h) Indicators RYB - 01 Set
(j) Earthing terminals and cable glands.
(k) Internal wiring of panel board with solid coductor copper cable single core of sutable size and incl 03 Nos bakelite control fuses.
(l) Danger notice plate for LT with conventional skull and bones duly rivetted/pasted to the panel board door. | - | - | - | - |
| 4 | Supply & install, testing and commissioning of factory made,CPRI approved factory made LT panel outdoor KIOSK type with double doors of suitable size provided with locking arrangements dust, weather and vermin proof 1100 volt grade, 50 Hz AC made out by 3.15 mm thick CRCA sheet steel, fully compartmentalised,seperate cable alley, cable gland with IP-65 protection all as per conforming to IS: 2417 of 1962 complete with and 50x50x5 mm thick angle iron for frame and legs, 04 Nos. legs 750 mm long 450 mm grouted in PCC blocks of type B-1 (1:2:4) with 300 mm ground clearance, for 415 volts, 3 phase, 4 wire AC supply complete all as directed with and including the following
(a) MCCB 4 pole 415 Volt, 200 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 36 KA - 01 No (incoming)
(b) MCCB 4 pole 415 Volt, 125 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 25 KA - 04 No (outgoing)
( c) MCB TPN 415 Volt, 32 Amp, 10KA-01 Nos
(d) Digital Voltmeter 96 sqmm 0 - 500V with selector switch - 01 No
( e) Digital Ammeter 96 sqmm 0 - 200 Amp with CTs and selector switch - 01 No
(f) Aluminium strip bus bars with colour code PVC insulation 300 Amps capacity - 01 Set
(g) Indicators RYB - 01 Set
(h) Earthing terminals and cable glands.
(i) Internal wiring of panel board with solid coductor copper cable single core of sutable size and incl 03 Nos bakelite control fuses.
(j) Danger notice plate for LT with conventional skull and bones duly rivetted/pasted to the panel board door. | 2 | Each | - | - |
| 5 | Supply & Fixing in replacement of MCCB 630 Amps, 4 pole, 415 Volts , 36KA, Ics=100% Icu Adjustable Thermal (0.8 to 1 x In) and Fixed Magnetic Release, complete all as specified and directed by the Engineer in Charge. | 2 | Each | - | - |
| 6 | Supply & Fixing in replacement of MCCB 400 Amps, 4 pole, 415 Volts , 36KA, Ics=100% Icu Adjustable Thermal (0.8 to 1 x In) and Fixed Magnetic Release, complete all as specified and directed by the Engineer in Charge. | 6 | Each | - | - |
| 7 | Supply & Fixing in replacement of MCCB 250 Amps, 4 pole, 415 Volts , 25KA, Ics=100% Icu Adjustable Thermal (0.8 to 1 x In) and Fixed Magnetic Release, complete all as specified and directed by the Engineer in Charge. | 8 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
tender.pdf
Tender Documents • 1.28 MB
BOQ_877890.xls
BOQ • 1.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].