| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.0 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹22.8 L+₹1.8 L (8.52%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹23.0 L+₹2.0 L (9.58%)Rejected-Finance | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹23.9 L+₹2.9 L (13.7%)Rejected-Finance | 4 | Rejected-Finance Being other than L-1 | |
| 5 | Rejected-Technical 60 310A 3 KHERIA MOD JAGNER ROAD AGRA 01 | AGRA | UTTAR PRADESH | 282001 | - | Rejected-Technical Being not enlisted in proper category |
Tender Value
₹23.3 L
EMD Value
₹46,500
Closing Date
6 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Adm Area Agra 282008
GE (AF) Adm Area Agra 282008
PROVISION OF EXTERNAL ELECTRIC SUPPLY TO CERTAIN BUILDINGS UNDER GE AF ADM AREA AT AIR FORCE STATION AGRA
2023_MES_579578_1
8000-2026/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Station Agra
Class E
Cat b ii
8 documents required · 8 mandatory
₹500
GE AF Adm Area Kheria Agra
₹46,500
Yes
16 Mar 2023
7 Feb 2023
8 Mar 2023
7 Feb 2023
6 Mar 2023
22 Feb 2023
7 Feb 2023 - 21 Feb 2023
Amount
Supply, installing, testing and commissioning outdoor type step down transformer, 11000/433 Volts (at no load) AC,3 phase, 50 Hz Cycle, 250 KVA, core type copper wound, oil immersed, naturally cooled, Oil natural, air natural (ONAN), with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol. DYN-11 (Vector Group) with neutral brought out on secondary side (LVside) and having tapping at + 2.5%to + 7.5% HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree Celsius in oil and 55 degree Celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp shall be strictly as per IS 1180/2014 regulations. The transformer shall be IS : 1180 marked and shall comprise of the following:- (a) One set of HT bushing on HT side consisting of 3 Nos porcelain bushing with brass rods complete with nut and washers of sutaible sizes:-
(b) One cable box on LT side consisting of 4 Nos porcelain bushing with brass rods complete with nut and washers. With two No cable glands suitable for reception /taking out XLPE insulated heavy duty armoured HT cables including gland, joint and jointing material complete. (c ) Oil conservator with filter type drain valve and oil level guage. (d) Dehydrating breather with first fill dehydrating agent (silica gel). (e) Explosive vent (f) Thermometer pocket on tank cover (g) One No 100 mm dia, dial type thermometer, vapour pressure type having range 0-120 degree Celsius with metal guard having maximum perimeter reading temparature indicator with resisting device for transformer. (h) Two earthing terminals in LT side box to facilitate fixing of 32x6mm galvanized iron earth strip for earthing of neutral & body. (j) Rating plate and terminal marking plate. (k) Oil level guage . (l) Oil drain filler valve
(m) Lifting lugs (n) Oil filling hole with cap/plug with connecting plate complete (o) Air release valve plug (p) Four plain solid cast steel detachable rollers (q) Extra bushing for neutral, outside the LT cable box for providing independent earthing for neutral. (r) First filling of new and unused transformer oil IS-335/93 (fourth revision) marked filtered and tested upto 40 KV dielectric strength at 2.5mm air gap between testing electrodes. (s) One danger notice board having conventional danger sign of skull with bones in painted in red colour.
Supply and installed cubicle compartmentalised outdoor type APFC panel of Cap 100 KVAR, factory made,double door front and rear opening with locking arrangement, dust and vermin proof, CPRI approved, fabricated out of 3.15 mm thick IP-56 CRCA sheet with canopy and base frame & mild steel stand made of 50 x 50 x 6 mm angle iron, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, danger plates etc. and panel shall comprising the following complete including fixed in position, connect with electric supply complete all as specified and directed by EIC. (a) Bus bar chamber having 4 aluminium Bus bar. TPN Aluminiium bus bar of rating not less than 2 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded hot shrinkable sleeves and shall be mounted on F class insulators. Busbar should be short time current capacity 30 KA Peak.
10 KVAR FEEDER (a) 25 A TP MCB, 10KA, D Curve - 4 Nos. (b) Capacitive Duty Contactor, 10 KVAR, 230V AC (Make-Schneider /L&T)- 4 Nos. (c) Capacitor Bank 10 KVAR, MPP Heavy Duty, 440V AC (Make- Schneider /L&T)- 4 Nos. (d) Indicating Lamp - LED Type-RED, 230V AC ON (Make-Rass) -04 Nos. (e) Flush Type,Pushbutton -START, STOP (make -L&T) - 08 Nos. 05 KVAR FEEDER (a) 16 A TP MCB, 10KA, D Curve - 2 Nos. (b) Capacitive Duty Contactor, 5 KVAR, 230V AC (Make-Schneider /L&T)- 2 Nos. (c) Capacitor Bank 05 KVAR, MPP Heavy Duty, 440V AC (Make- Schneider /L&T)- 2 Nos. (d) Indicating Lamp - LED Type-RED, 230V AC ON (Make-Rass) -02 Nos. (e) Flush Type,Pushbutton -START, STOP (make-L&T) - 04 Nos
Supply, installing, erecting, commissioning and testing new factory made LT panel board cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including TPN copper bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-
M&L for earthing with steel earth plate electrode of size 600x600x6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earth lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate, 40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe light grade with funnel and wire mesh, complete all as per SSR with PCC pit 50mm thick, RCC cover 540 x 540 x 50 mm thick in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 75 mm c/c both way in lieu of CI cover, adequate qty of charcoal dust and salt layers all around the earth plate, including earth work in any type of soil, removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed. (Note: Excavation and earth work is deemed to be included in the rates quoted).
M&L for earthing complete with copper earth plate electrode 600x600x3.15 mm tthick buried directly in ground(earth pit not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to copper earth strip 20 x 3 mm thick by means of nuts, bolts, washers and check nuts of brass, 40 mm bore GI pipe light grade proection pipe up to test point, 20mm dia light grade GI pipe for watering, meshed funnel, alternate layer of charcoal and common salt complete all as per SSR with PCC pit 50mm thick, RCC cover 540 x 540 x 50 mm thick in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 75 mm c/c both way in lieu of CI cover, and protection including necessary excavation and earth work complete all as specified and directed.
Supply, laying, testing and commissioning of HT UG cable, XLPE insulated screened PVC bedded, galvanised strip or wire armoured electric power cable (heavy duty) with multistranded aluminium conductor 11 KV grade of size 3 Core 95 Sqmm (Earthed system cable) as per IS 7098 Part II completed and specified as directed.
Supply and Laying in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated, bedded, galvanised steel strip or wire armoured, heavy duty electric cable 1100 volts grade with aluminum conductor of 240 Sqmm 3.5 core complete all as specified and directed.
Supply and Laying in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated, bedded, galvanised steel strip or wire armoured, heavy duty electric cable 1100 volts grade with aluminum conductor of 120 Sqmm 3.5 core complete all as specified and directed.
Supply and Laying in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated, bedded, galvanised steel strip or wire armoured, heavy duty electric cable 1100 volts grade with aluminum conductor of 95 Sqmm 3.5 core complete all as specified and directed.
Supply and Laying in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated, bedded, galvanised steel strip or wire armoured, heavy duty electric cable 1100 volts grade with aluminum conductor of 70 Sqmm 3.5 core complete all as specified and directed.
M&L for cable end terminal joints (heat shrinkable) indoor type suitable for XLPE 11000 Volts aluminium conductor cable of size 95 Sqmm 3 core and testing after jointing complete all as specified and directed.
M&L for cable end terminal joints (heat shrinkable) outdoor type suitable for XLPE 11000 Volts aluminium conductor cable of size 95 Sqmm 3 core and testing after jointing complete all as specified and directed.
Excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc or for laying for cables etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any type of soil including removal of sand, bricks/PCC covers laid for cable proection complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exc. 25 cm in any type of soil complete all as specified and directed.
Removing surplus excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Supply, fixing and laying double corrugated HDPE spilt pipe in 2 Mtrs Size in 120mm OD/103 mm ID as per IS 16205 Part 24 complete all as specified and directed. (Make: Astral/Telerex/ JPC pipes Pvt Ltd./ Bhagwati Plastic & Agriculture Industries)
Supply, fixing and laying double corrugated HDPE spilt pipe in 2 Mtrs Size in 160mm OD/120 mm ID as per IS 16205 Part 24 complete all as specified and directed. (Make: Astral/Telerex/ JPC pipes Pvt Ltd./ Bhagwati Plastic & Agriculture Industries)
Supply, fixing and laying double corrugated HDPE spilt pipe in 2 Mtrs Size in 315 mm OD/ 271 mm ID as per IS 16205 Part 24 complete all as specified and directed. (Make: Astral/Telerex/ JPC pipes Pvt. Ltd./ Bhagwati Plastic & Agriculture Industries)
M&L for PCC 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete including necessary formwork complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in mass concrete, foundation/base of transformer including necessary formwork and finishing even and smooth complete all as specified and directed.
S&F ceiling fan 1200 mm sweep complete with blades, electronic regulator and other accessories, single phase, 230 V, minimum air delivery 230 CMM with service value 6.00 BEE and making connection with flexible wire 23/0.076 mm complete all as specified and directed. Make :- Crompton Model HP Plus/ Bajaj Model Speedstar/ Havells Model Glaze new
S&F Down rod MS 15mm dia, heavy duty of size 600 mm long including making hole for hanging ceiling fan complete all as specified and directed.
GUPTA ENGINEERING WORKS
virendera singh
BHARADWAJ BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .