AGE (I) CIF (R)
AGE(I) CIF(R) C/O 56 APO
REPAIR/ MAINTENANCE OF PERIMETER SECURITY LIGHTS, STREET LIGHTS AND OTHER CONNECTED WORKS AT HQ CIF (R) AND SIGNAL REGT UNDER AGE (I) CIF (R)
2024_MES_666298_1
AGE(I)/R-42/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AGE (I) CIF(R)
Class E and above and category b(i)
8 documents required · 8 mandatory
₹500
AGE (I) CIF (R)
₹19,600
Yes
19 Oct 2024
18 Jul 2024
20 Sept 2024
18 Jul 2024
13 Sept 2024
2 Aug 2024
Amount
Supply, fixing and errection of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 09 Mtr metres long. Poles shall be coated with two coats of black bituminous paint throughout internally, and externally up to the planting depth. The remaining portion of the exterior shall be painted with one coat of red oxide primer including taking down old unserviceable pole complete all as specified and directed . Note:-Necessary excavation and foundation are measured and paid separately.
Shifting of poles 09 mtr long including all accessories (junction box, street light, service connection cable, clamp ) without any damage from one place to another place not exceeding 200 mtr and errection at new place. Poles shall be coated with two coats of black bituminous paint throughout internally, and externally up to the planting depth complete all as specified and directed. Note:-Necessary excavation and foundation are measured and paid separately.
M&L in replacement of earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion, complete all as specified and directed.
Excavation in trenches in hard/dense soil not exc 1.5m wide and n.exc 1.5m in depth for electric poles stay foundation and under ground electric power cables and getting out, complete all as specified and directed.
Excavation in trenches exceeding 1.50m wide and exceeding 1.50m in depth and getting out in for hard/dense soil, all as specified .
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm in any type of soil complete all as specified and directed.
Removing surplus spoil to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.50m from the starting point., all as specified .
M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed.
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 16 Sqmm 4 core including taking down old cable, complete all as specified and directed by Engineer-in-Charge.
All as per ser item No 10.00 here in before but 25 Sqmm 3.5 core
All as per ser item No 10.00 here in before but 10 Sqmm 2 core
Supply and fixing in replacement MCCB 250 Amps, four pole, 415 volt,50 Hz with breaking capacity 36 KA, adjustable thermal & adjustable magnetic, complete all as specified and directed.
Supply and fixing in replacement MCCB 200 Amps, four pole, 415 volt,50 Hz with breaking capacity 36 KA, adjustable thermal & adjustable magnetic, complete all as specified and directed.
M&L in Replacement of GI bracket made of 40 mm medium grade GI pipe bend to shape approx 1.2 mtr length including suitable clamp ,nut,bolt,washers etc complete for fixing of street light.
S&F in Replacement of Junction box SMC KIOSK box water proof IP-54 of size 270 X 225 X 135 mm incl fixing of terminal connector 100A, 4 pole suitable for in and out connection of 4 core cable fixed on pole complete all as specified and directed.
S&F Copper cable 1.5 Sqm 3 core PVC sheathed multi core for connection of street light inserting from top in side the pole and connecting in junction box complete and making Hole in Pole as per Site including taking down old cable, all as directed by Engineer-in-Charge
M & L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping of pole around pole all as specified and as directed by Engineer-in-Charge.
M & L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as foundation of pole all as specified and as directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in foundation of pole around pole and for road filling all as specified and as directed by Engineer-in-Charge.
S&F LED Post Top Lantern 25 watt luminaire with diffuser and painted spun aluminium deflector including 3 core 1.5 sqmm multistranded flexible copper conductor cable from connection junction box to light fittings deemed to be included in the quoted rate and taking down old unserviceable. Make :(Cat RUBYPT25WLED757PSYMTOPC of Havells or equivalent cat part of make as specified in list of make here-in-after.
S&F in Replacement of LED Post Top Bolard light 10 W, UFO shape IP-65 including nesessory excavation and PCC work for fixing including 3 core 1.5 sqmm multistranded flexible copper conductor cable from connection junction box to light fittings deemed to be included in the quoted rate and taking down old unserviceable Complete . Make :(Cat MINIMOUNTBL10WLED830PSYMTOPMMAS(1.0 M) of Havells or equivalent cat part of make as specified in list of make here-in-after.
S&F in replacement of New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device of capacity 90 Watt including 3 core 1.5 sqmm multistranded flexible copper conductor cable from connection junction box to light fittings deemed to be included in the quoted rate and taking down old unserviceable. Make : (Cat ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO of Havells or equivalent cat part of make as specified in list of make here-in-after.
S&F in replacement of New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source with toughened glass top cover. TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device. of capacity 120 Watt including 3 core 1.5 sqmm multistranded flexible copper conductor cable from connection junction box to light fittings deemed to be included in the quoted rate including taking down old unserviceable. Make : (Cat ENDURAPEARLMAGSL120WLED757PASYTOTGASTHO of Havells or equivalent cat part of make as specified in list of make here-in-after.
S&F in replacement of Energy saving, environment friendly, long life, exclusive innovative die-cast aluminium flood light with highly efficient IP- 66 LEDs as light source, suitable for highlighting architectural features or retail spaces of capacity 200 Watt completed with connection including 3 core 1.5 sqmm multistranded flexible copper conductor cable from connection junction box to light fittings deemed to be included in the quoted rate and taking down old unserviceable. Make : (Cat JETAIRISMAXFL200WLED757PNBLTG of Havells or equivalent cat part of make as specified in list of make here-in-after.
Steel tubing galvanized (medium grade) 50 mm bore conforming to IS-1239 for passing cable under road/floor or fixing to poles for protection of underground cable complete with Flat iron 50x6mm clamps made to shape and 12mm dia bolts, nuts including taking down existing pipe and washers for fixing where required. NOTE :- Excavation and earth work shall be measured and paid separatly
Steel tubing galvanized (medium grade) 40 mm bore conforming to IS-1239 for passing cable under road/floor or fixing to poles for protection of underground cable complete with Flat iron 50x6mm clamps made to shape and 12mm dia bolts, nuts including taking down existing pipe and washers for fixing where required. NOTE :- Excavation and earth work shall be measured and paid separatly
M & L for pole painting 9.0 mtr long with two coat of aluminium paint after preparation of old painting surface by scrappining including marking of black and yellow strip not less than 30 cm width with sythethic enamelled paint from couping to upto height 1.5 mtr of pole alternative way including necessary `MES & Pole number to be wriiten in the circular yello batch on the pole all as specified and directed.
Supply and fixed in replacement of Environmental friendly, new generation, energy saving, decorative spike light using COB LED 09 watt as light source 3 core 1.5 sqmm multistranded flexible copper conductor cable from connection junction box to light fittings deemed to be included in the quoted rate including taking down old unservicable light fittings all as specifed and directed. Make : LYCUSSPS9WLED730PSYMBOTG of Havells or equivalent cat part of make as specified in list of make here-in-after.
Supply and fixed in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire, complete all as specified and directed.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of ₹ 26,230.00 during AOC Note:- Tenderers shall not quote for this Schedule
KRISHNA ENGINEERING ENTERPRISES (BID ID -3090833)
ABINASHI ENTERPRISES (BID ID -3095052)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .