Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹32.7 L+₹85,450 (2.69%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹34.6 L+₹2.8 L (8.85%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹34.7 L+₹2.9 L (9.13%)Rejected-Finance 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹35.3 L+₹3.5 L (10.9%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
15 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Nasik Road
As per Tender Documnets
2023_MES_594770_2
GE/NRC/8962/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Nasik Road
As per NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer Nasik Road
₹79,000
Yes
7 Aug 2023
24 Jun 2023
17 Jul 2023
24 Jun 2023
15 Jul 2023
1 Jul 2023
Amount
Excavation in trenches in any type of soil, n. exc. 1.5m wide and n. exc. 1.5m deep and getting out complete.
M&L for PCC(1:4:8) type D-2 using 40mm graded stone aggregate in foundation mass concrete and filling complete.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc all as specified and directed.
Formwork to sides of pillars,posts, struts, piers, columns and stanchions etc all as specified and directed.
M&L for providing RCC 1:2:4 Type B1 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams,plinth beams, bases for column etc using 20mm graded aggregates all as specified and directed.
M&L for providing RCC 1:2:4 Type B1 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts etc using 20mm graded aggregates all as specified and directed.
M&L for TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc.
All as per item No 08 but 6mm to 8mm dia complete all as specified and directed.
M&L for returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm in soft/loose soil all as specified and directed.
Removal of surplus excavated soil to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above starting point complete.
M&L for 15 mm thick rendering on brick work or concrete surface in two layer, in cement mortar 1:4 mixed with water proofing compound 200gm per 50Kg weghit of cement, surface finished even and smooth without using extra cement complete.
M&L for reparing of newly plastered/concrete surfaces of walls and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces
S&F high tensile fabric sheet covered overhead shed approximate ht 5 to 6 m including M.S tubular frame painted with red oxide coating and Deco/Aspa spary paint, inculding fixing of Membrane, plotting of structure, patterning & HF welding of Membrane, Heat sealing of Membrane, waterproofing of Structure, fixing of M.S Fitting, metalic Ribs, Stainless steel fitting all as per described fwg structure and technical specification, Note: Cost also inclusive of making arrangement necessary scaffholding and ladders required. (a) Roof : Architectural membrane Make with Fabric 730 GSM fabric 100% polyester/ 1100 detx, HIGH TENCITY PRE-TREATED LOW WICK POLYESTER, Weaving style DIN ISO 2286, Total weigt 780 g/Sqm. ANTI MOULD-UV PROTECTEDTOPSIDE HQ, Lacquering 1/1, Embossing Glossy, Breaking strength Warp 3000N/5cm, breaking strength Weft 3000 N/5cm, Tear strength Warp 300N, Tear strength Weft 300/N, Adhesion 120 N/5cm Temperature resistance - 45 +70º c, Light fastness 7 , Fire behaviour b-s2, do, Fire behaviour reaction to fire, Adhesion 120 N/5cm, Application Tent TA/Arc Membrane (b) Structure: MS Column 165 Od/3.5mm, Top MS Top pipe 76 Od/3mm, MS Tai Rod pipe 60 Od/2.5mm, Base Plate 350 x 350 x 12mm, S Fitting 304 Grade, Red oxide then Deco/Aspa Spray Paint.
S&F framed work as in doors or gates of angle or other section with gusset plates,rails,braces,etc., complete,drilled for fixing of steel sheeting or other covering,door etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings(exclusive of steel running rails and guides) and hanging also fastening and fixing complete fabrication and erection (Fe-290 Gde-165)
S&F 1.60 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
M&L for preparation new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description,over 10 cm width or girth not otherwise described complete all as specified and as directed.
S&F Bands,straps,supports and stays for rain water,ventilating pipes inlcuding bolts if required: hooks(stays),heavy for large gates ;hook and pintle hinges:large hasps and staples; chains;hand made sliding bolts; clamps;hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165
M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 50mm and innter dia 38mm including 90 degree bends with coupler and rubber ring laid in trenches of size 50 mm suitable for cable protection of size 2 core 10 sqmm to 3.5 core 50 sqmm cable complete all as specified and directed.
M&L for Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
Supply, laying or fixing or passing through pipe commissioning and testing of XLPE insulated, armoured heavy duty, electric power cable with aluminium conductor, 1100 volts grade of cross sectional area 16 sqmm 4 core including suitable size lugs complete all as specified and directed Note:- Excavation & earth work, HDPE pipe where required shall be measured & paid separately under relevant items.
Supply, laying or fixing or passing through pipe commissioning and testing of XLPE insulated, armoured heavy duty, electric power cable with aluminium conductor, 1100 volts grade of cross sectional area 10 sqmm 4 core including suitable size lugs complete all as specified and directed Note:- Excavation & earth work, HDPE pipe where required shall be measured & paid separately under relevant items.
M&L for drilling (Horizontally) without cutting/ damaging existing road (Maximum 10 mtr wide) suitable for passing HDPE pipe of dia 50mm suitable for 0.4mpa working pressure complete all as specified and directed.
M&L for submain wiring with two single core PVC insulated unsheathed, FRLS type, multistranded flexible copper conductor 1100Volts grade cables 2 x 4 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits including 4 Sqmm 1100 Volts grade PVC insulated unsheathed multi stranded, FRLS type flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified & directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground, (Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to and including galvanised iron earth strip 25x4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 3 of MES SSR part-I (2009) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 32 mm nominal bore medium grade GI protection pipe 7 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground, (Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to and including galvanised iron earth wire 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 3 of MES SSR part-I (2009) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 20 mm nominal bore medium grade GI protection pipe 7 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply and fixing LED flood lights not less than 200 watts, nominal voltage 240 volts, 50 Hz, high efficiency long life LED module with SMD LED package mounted on MCPCB, lumen efficacy of LED shall not be less than 100 lumen/W, Colour temp (CCT) -5700K and viewing angle of 120 degree to ensure better uniformity, epoxy powder coated pressure die cast aluminium housing elegantly designed heat sink for efficient thermal management, high quality toughened glass IK 07 fixed to housing, having electronic driver, integral, isolated electronic driver with lower THD, output open/short circuit protection, over voltage protection, surge voltage protection with SPD not less than 10 KV and other safety test as per IS 15885 Part-2/Sec 13, having adjustable MS cradle of thickness 5mm provided with the fixture by 2 elliptical slots complete all as specified and directed,
Supply, installation, commissioning and testing of latching High mast made up of galvanised special steel conforming to IS, ASTM- A- 572/BN -EN -10025 continuously tapered 12 sided polygonal cross section suitable for lighting system. it shall be suitable for wind speed as per IS-875, Part- 3, 1987 double section of length approximately 16 meters to sustain as arising wind speed as per is 875 . An opening door shall be provided at the base that shall access to equipment installed in it in and including providing of double drum winch & cable Plug and socket, double lock paddle, raising & lowering mechanism, lantern carriage ring suitable to carry 06 Nos LED light of wattage above 200 watts, whinch head frame, torque motor, limitor switch, cable trailing which, aluminium Pulley, having three point suspension system with stainless steel wire rope AISI 316 grade, 6mm dia 97/19 construction in and including suitable terminal box shall be provided at base compartment of high mast for terminating incoming cables made up of special rubber trailing with EPR insulation and PVC sheathed & suitable power electrically driven tool shall couple with winch using sprocket motor mounted at base of mast with compartment one number heavy duty hot dip galvanised lighting finial shall be of 2 mtr in length shall provide centre of head frame, suitable earthing terminal at base minimum 12mm diameter GI nuts and bolts, base plate shall be not less than 570mm, 3mm thick, PCD -490mm, bottom of the high mast shall not be less than 410mm and top shall not be less than 150mm dia in and including providing foundation bolt manufactured from special steel and hot dip galvanised alongwith nuts and bolt fixing the same in PCC foundation and base plate of high mast complete all as specified and directed in and including the following :-
(a) Excavation, returning and filling in excavated soil, removal of surplus soil from site and depositing upto meter in low laying area as directed by Engr-in-charge at site (b) M&L for construction of foundation for 16 meter high mast considering the soil load bearing capacity 10 ton/sqm at 2 meter depth, (the contractor shall submit the OEM foundation drawing with complete details for approval by the Engr-in-charge before progressing the work at site as per manufacturer proposal) (c) Providing of suitable size and length of cable from terminal block in base of High mast upto LED light with the provision of rolling winch which can be operable at the time of taking down of light carriage from top to bottom. (d) LT Panel having incoming MCCB, outgoing MCCB/MCBs, time switch, contactor, indicator, voltmer suitable for controlling of electric supply of high Mast as per manufacturers design. (e) Aviation obstruction light, yellow painted die-cast aluminium alloy housing LED lights , heat resistent clear thick glass and accessories all as specified and directed connected electrically from LT feeder Pillar box to aviation lights of suitable length of size 2.5sqmm, 3 core industrial, copper flexible cable in and including providing of lightening protection spike complete all as specified. Note : 1. The contractor will make the High Mast functional in all respect, if anything missed out, the contractor shall provide the same without any extra cost or claim to the department 2. The contractor shall submit warranty of material for one year from the date of certified date of completion
Supply and fixing LED highbay 200watt, light with electronic driver and other connected items , protection IP 65 including connecting up with twin core twisted flexible copper conductor cable with suitable size, 230 volts, 50 Hz, high efficiency long life LED module with SMD LED package mounted on MCPCB, lumen efficacy of LED shall not be less than 100 lumen/W, Colour temp (CCT) -5700K complete all as specified and directed.
Supply & fixing of sheet metal enclosure (factory made) double door shutter type for distribution board (when MCBs are to be used) triple pole and neutral 415 volts, 4 way with 200 Amps rated busbar including dressing and connecting both incomimg and outgoing cable termination with proper taping complete all as specified and directed.
Supply & fixing of sheet metal enclosure (factory made) double door shutter type for distribution board (when MCBs are to be used) single pole and neutral 230 volts, 4 way with 200 Amps rated busbar including dressing and connecting both incomimg and outgoing cable termination with proper taping complete all as specified and directed.
Supply and fixing 415 Volt, 'B' curve miniature circuit breaker MCB TPN of rating 63 Amps and current carrying capacity 10 KA installed in the DB complete with connection testing and commissioning.
Supply and fixing of MCB SPN 6-32 Amps, 230 Volts, 50 Hz with 10 KA installed in the DB complete with connection testing and commissioning.
Supply and fixing of MCB SP 6-32 Amps, 230 Volts, 50 Hz with 10 KA installed in the DB complete with connection testing and commissioning.
Supply and fixing of MCB SP 40-63 Amps, 230 Volts, 50 Hz with 10 KA installed in the DB complete with connection testing and commissioning.
N K ASSOCIATES
sapana enterprises
MAHIMA CONSTRUCTION
M/s.NIKI ENTERPRISES
SHRI SULAI ELECTRICALS
Bidder Name
DHARMESH ENTERPRISES
SHRI SULAI ELECTRICALS
sapana enterprises
N K ASSOCIATES
M/s.NIKI ENTERPRISES
MAHIMA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .