Loading…
Loading…
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
30 Sept 2026, 6:00 pm
GE (AF) GURGAON
GE (AF) GURGAON
REPAIR/MAINT OF DG SETS OF DIFFERENT CAPACITIES, AMF PANELS SECURITY/STREET LIGHT FITTINGS SECURITY LIGHT POLES EARTHING INFRASTURUTURE AND ALLIED WORKS AT AF STN RAJOKRI UNDER GE AF GURGAONNNECTED ITEMS AT AIR FORCE STATION INDAUR UNDER AGE E/M ARJ
2026_MES_788521_1
GE/GUR-/NIT-85/2026-27
Open Tender
Civil Works
Item Rate
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹90,000
9 Sept 2026
9 Sept 2026
3 Oct 2026
9 Sept 2026
30 Sept 2026
23 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for attending complatints of street light, flood light,high mast light mounted at any height in pole/hanger in domestic and tech area of AFS Rajokri and connected road light by checking connection , serviceability of fittings, SMC boxes , MCB, thimbles or any other minor fault complete all as specified and directed. Note- (a) Arrangement of Ladder shall be done by contractor. (b) Arrangement of hydra as and when required or any other T&P, Grese for attending complaints of Hanger light/high mast light shall be done by contractor.(c) Complaints shall be rectified with in 24 Hours.if contractor fails to attend the complaints a recovery of Rs 500 per day shall be deducted from payment due to contractor(e) Weekly inspection of all security lights/street lights of area under AFS Rajokri shall be carried out and report shall be submitted to Engr-in-chage without any delay. | 2,000 | Each complaint | - | - |
| 2 | Supply and fixing in rerplacement LED type street light 35 watt 230 volts AC outdoor type with IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed. | 35 | Each | - | - |
| 3 | Supply and fixing in replacement LED type street light 60 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed. | 200 | Each | - | - |
| 4 | Supply and fixing in replacement LED type street light 90 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed. | 200 | Each | - | - |
| 5 | Supply and fixing in replacement LED type flood light 70 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed.. | 20 | Each | - | - |
| 6 | Supply and fixing in replacement LED type flood light 100 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed.. | 50 | Each | - | - |
| 7 | Supply and fixing in replacement LED type flood light 120 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed.. | 50 | Each | - | - |
| 8 | Supply and fixing in replacement LED type flood light 250 watt 230 volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed.. | 50 | Each | - | - |
| 9 | Supply and fixing in replacement post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K/3500k (warm white or cool day white as per site requirement), inbuilt surge protection = 5 Kv, 50000 Hrs burning hours including gountong of light grade pipe of suitable length on post complet all as specified and directed.. | 30 | Each | - | - |
| 10 | Supply and fixing in replacement LED Bollard 8 watt 230 volts AC outdoor type with decorative for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular at the top and opaque acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K/3500K/3000K as required at site, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed. Note- (1)Earth work and PCC shall be included in quoted rate.(2) Model and design shall be finalized by dept. | 50 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
TenderDocuments85.pdf
Tender Documents • 0.42 MB
BOQ_883871.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .