Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 CrAccepted-AOC NOT SPECIFIED | ₹2.9 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹3.2 Cr+₹28.1 L (9.77%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹3.2 Cr+₹28.1 L (9.77%) | L2 | Rejected-Finance Not lowest |
| 3 | L3₹3.4 Cr+₹49.7 L (17.3%)Rejected-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹3.4 Cr+₹49.7 L (17.3%) | L3 | Rejected-Finance Not lowest |
| 4 | L4₹3.7 Cr+₹85.3 L (29.7%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹3.7 Cr+₹85.3 L (29.7%) | L4 | Rejected-Finance Not lowest |
| 5 | L5₹3.7 Cr+₹86.5 L (30.1%)Rejected-Finance 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | ₹3.7 Cr+₹86.5 L (30.1%) | L5 | Rejected-Finance Not lowest |
| Sl No | Description | Qty | Unit | Shri Sai Electricals L9 | SHRI GANESH ENTERPRISES L6 | M/s Prem Associates L7 | Shree Ayyappa Engineering L2 | United Sales Corporation L1 | R D Bansal L4 | UNIQUE ENGINEERS L10 | Leo Air and Power Solution pvt Ltd. L3 | NATIONAL ENGINEERING CORPORATION L8 | Vijaypower Generators Limited L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and errection of Swaged tubular steel poles conforming to IS: 2713 standards, ensuring durability and reliability for overhead power lines complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 m long) including two coats of aluminium paint over a red oxide primer, providing corrosion resistance and a long-lasting finish, complete all as specified and directed. | 8 | EACH | 28,000 ₹2,24,000 | 20,000 ₹1,60,000 Lowest | 27,000 ₹2,16,000 | 25,500 ₹2,04,000 | 22,000 ₹1,76,000 | 35,500 ₹2,84,000 | 35,000 ₹2,80,000 | 30,065 ₹2,40,520 | 30,000 ₹2,40,000 | 3,66,000 ₹29,28,000 |
| 2.00 | M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. | 15 | PER QUINTAL | 11,000 ₹1,65,000 | 100 ₹1,500 Lowest | 12,000 ₹1,80,000 | 14,000 ₹2,10,000 | 10,000 ₹1,50,000 | 12,000 ₹1,80,000 | 1,05,000 ₹15,75,000 | 12,000 ₹1,80,000 | 12,000 ₹1,80,000 | 13,900 ₹2,08,500 |
| 3.00 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundations of HT/LT poles etc complete including necessary formwork weathering, and ramming, complete all as specified and directed. | 3.5 | CUBIC METRE | 2,800 ₹9,800 Lowest | 7,000 ₹24,500 | 4,000 ₹14,000 | 5,800 ₹20,300 | 3,500 ₹12,250 | 4,500 ₹15,750 | 4,500 ₹15,750 | 4,000 ₹14,000 | 9,000 ₹31,500 | 8,400 ₹29,400 |
| 4.00 | M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundations of stays and HT/LT poles etc complete including necessary form work weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. | 24 | CUBIC METRE | 3,200 ₹76,800 | 3,000 ₹72,000 Lowest | 5,000 ₹1,20,000 | 6,300 ₹1,51,200 | 4,000 ₹96,000 | 3,500 ₹84,000 | 5,000 ₹1,20,000 | 4,500 ₹1,08,000 | 5,000 ₹1,20,000 | 9,600 ₹2,30,400 |
| 5.00 | M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate as in coping weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. | 4 | CUBIC METRE | 3,650 ₹14,600 | 10,000 ₹40,000 | 6,000 ₹24,000 | 6,200 ₹24,800 | 4,000 ₹16,000 | 3,500 ₹14,000 Lowest | 5,200 ₹20,800 | 4,000 ₹16,000 | 4,500 ₹18,000 | 9,600 ₹38,400 |
| 6.00 | M&L for Anti climbing devices; comprising of 2.24 mm dia galvanised steel 2-strand barbed wire with 2 mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 m clamped and properly secured or as ordered (clamps measured separately) complete all as specified and directed. | 0.1 | PER QUINTAL | 12,000 ₹1,200 | 150 ₹15 Lowest | 14,000 ₹1,400 | 14,000 ₹1,400 | 10,000 ₹1,000 | 15,000 ₹1,500 | 95,000 ₹9,500 | 15,000 ₹1,500 | 12,000 ₹1,200 | 1,080 ₹108 |
| 7.00 | Supply and fixing Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25x20cm size, complete all as specified and directed. | 8 | EACH | 850 ₹6,800 | 500 ₹4,000 | 300 ₹2,400 | 250 ₹2,000 | 500 ₹4,000 | 200 ₹1,600 Lowest | 250 ₹2,000 | 549 ₹4,392 | 400 ₹3,200 | 390 ₹3,120 |
| 8.00 | Supply and fixing light grade galvanized iron pipe, ensuring durability and corrosion resistance, 100 mm dia (nominal) to accommodate standard cables, 3 m length, suitable for installation along or across the poles/channel to shield underground cables, above ground for protection of underground cable as required, complete all as specified and directed. | 7 | EACH | 3,500 ₹24,500 | 2,000 ₹14,000 | 4,500 ₹31,500 | 4,000 ₹28,000 | 3,000 ₹21,000 | 7,600 ₹53,200 | 1,000 ₹7,000 | 897 ₹6,279 Lowest | 4,000 ₹28,000 | 1,902 ₹13,314 |
| 9.00 | Supply, installation, testing and commissioning of extensible, motorised 24 KV Indoor Ring Main Unit (02 Nos incoming Load Break Switch (LBS) and 03 Nos outgoing VCB Breaker) having capacity of 630A, the STC for RMU shall be 16KA, STC: 20kA for 3 sec with CTs, PTs, metering, protection relays, battery charger and Battery backup, Temperature class: -25 °C - +40 °C outdoor, Degree of protection: (i) SF6 tank: IP 67 (ii) Front cover: IP 2X (iii) Cable cover: IP 3X (iv) Enclosure IP 54 complete all as specified and directed with the standard following equipment: -
(i) Earthing switches (ii) Operating mechanisms with integral mechanical interlocking (iii) Operating handle (iv) Facilities for padlocks on all switching functions (v) Bushings for cable connection in front with cable covers (vi) Manometer for SF6 -pressure/density monitoring (vii) Lifting lug for easy handling (viii) All units are designed for the subsequent fitting of an integral remote control and monitoring unit (ix) Colours: (a) Front cover: RAL 7035 (b) Side and cable cover: RAL 7035 (c) Enclosure IS 632 (x) Pressure of SF6 gas: 1.4 bar at 20 °C (xi) Impulse withstand voltage: To earth and between phases: 125 kV, Insulation level: Power frequency 1 min: 50 kV | 1 | EACH | 31,50,000 ₹31,50,000 | 25,00,000 ₹25,00,000 | 23,55,000 ₹23,55,000 | 21,53,000 ₹21,53,000 | 15,00,000 ₹15,00,000 Lowest | 21,55,000 ₹21,55,000 | 20,00,000 ₹20,00,000 | 17,08,860 ₹17,08,860 | 32,00,000 ₹32,00,000 | 18,43,750 ₹18,43,750 |
| 10.00 | Supply, installation, testing and commissioning of extensible, motorised 24 KV Indoor Ring Main Unit (02 Nos incoming Load Break Switch (LBS) and 02 Nos outgoing Vacuum Circuit Breaker (VCB)) having capacity of 630A, 16KA, STC: 20kA for 3 sec with CTs, PTs, metering, protection relays, battery charger and Battery backup, Temperature class: -25 °C - +40 °C outdoor, Degree of protection: (i) SF6 tank: IP 67 (ii) Front cover: IP 2X (iii) Cable cover: IP 3X (iv) Enclosure IP 54 complete all as specified and directed. with the standard following equipment: -
(i) Earthing switches (ii) Operating mechanisms with integral mechanical interlocking (iii) Operating handle (iv) Facilities for padlocks on all switching functions (v) Bushings for cable connection in front with cable covers (vi) Manometer for SF6 -pressure/density monitoring (vii) Lifting lug for easy handling (viii) All units are designed for the subsequent fitting of an integral remote control and monitoring unit (ix) Colours: (a) Front cover: RAL 7035 (b) Side and cable cover: RAL 7035 (c) Enclosure IS 632 (x) Pressure of SF6 gas: 1.4 bar at 20 °C (xi) Impulse withstand voltage: To earth and between phases: 125 kV, Insulation level: Power frequency 1 min: 50 kV | 1 | EACH | 21,25,000 ₹21,25,000 | 20,00,000 ₹20,00,000 | 20,00,000 ₹20,00,000 | 19,07,000 ₹19,07,000 | 12,00,000 ₹12,00,000 Lowest | 17,50,000 ₹17,50,000 | 16,50,000 ₹16,50,000 | 14,98,248 ₹14,98,248 | 26,00,000 ₹26,00,000 | 14,75,000 ₹14,75,000 |
Tender Value
₹4.2 Cr
EMD Value
₹4.9 L
Closing Date
16 Jun 2025, 6:00 pmClosed
CHIEF ENGINEER RND SECUNDERABAD
CHIEF ENGINEER RND SECUNDERABAD PICKET OPP JUBILEE BUS STATION SECUNDERABAD 500003
PROVISION OF EXTERNAL SERVICES FOR CENTRE OF ELECTROMAGNETIC LAUNCH TECHNOLOGY (CEMALT) AT TECHNICAL AREA-III ARDE UNDER GE I RND PASHAN, PUNE
2025_MES_708113_1
81394
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
PASHAN PUNE
Class A
category b(i)
8 documents required · 8 mandatory
₹2,000
GARRISON ENGINEER I RND PASHAN PUNE
₹4.9 L
Yes
9 Sept 2025
14 May 2025
18 Jun 2025
14 May 2025
16 Jun 2025
9 Jun 2025
Amount
Supply and errection of Swaged tubular steel poles conforming to IS: 2713 standards, ensuring durability and reliability for overhead power lines complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 m long) including two coats of aluminium paint over a red oxide primer, providing corrosion resistance and a long-lasting finish, complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundations of HT/LT poles etc complete including necessary formwork weathering, and ramming, complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundations of stays and HT/LT poles etc complete including necessary form work weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate as in coping weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L for Anti climbing devices; comprising of 2.24 mm dia galvanised steel 2-strand barbed wire with 2 mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 m clamped and properly secured or as ordered (clamps measured separately) complete all as specified and directed.
Supply and fixing Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25x20cm size, complete all as specified and directed.
Supply and fixing light grade galvanized iron pipe, ensuring durability and corrosion resistance, 100 mm dia (nominal) to accommodate standard cables, 3 m length, suitable for installation along or across the poles/channel to shield underground cables, above ground for protection of underground cable as required, complete all as specified and directed.
Supply, installation, testing and commissioning of extensible, motorised 24 KV Indoor Ring Main Unit (02 Nos incoming Load Break Switch (LBS) and 03 Nos outgoing VCB Breaker) having capacity of 630A, the STC for RMU shall be 16KA, STC: 20kA for 3 sec with CTs, PTs, metering, protection relays, battery charger and Battery backup, Temperature class: -25 °C - +40 °C outdoor, Degree of protection: (i) SF6 tank: IP 67 (ii) Front cover: IP 2X (iii) Cable cover: IP 3X (iv) Enclosure IP 54 complete all as specified and directed with the standard following equipment: - (i) Earthing switches (ii) Operating mechanisms with integral mechanical interlocking (iii) Operating handle (iv) Facilities for padlocks on all switching functions (v) Bushings for cable connection in front with cable covers (vi) Manometer for SF6 -pressure/density monitoring (vii) Lifting lug for easy handling (viii) All units are designed for the subsequent fitting of an integral remote control and monitoring unit (ix) Colours: (a) Front cover: RAL 7035 (b) Side and cable cover: RAL 7035 (c) Enclosure IS 632 (x) Pressure of SF6 gas: 1.4 bar at 20 °C (xi) Impulse withstand voltage: To earth and between phases: 125 kV, Insulation level: Power frequency 1 min: 50 kV
Supply, installation, testing and commissioning of extensible, motorised 24 KV Indoor Ring Main Unit (02 Nos incoming Load Break Switch (LBS) and 02 Nos outgoing Vacuum Circuit Breaker (VCB)) having capacity of 630A, 16KA, STC: 20kA for 3 sec with CTs, PTs, metering, protection relays, battery charger and Battery backup, Temperature class: -25 °C - +40 °C outdoor, Degree of protection: (i) SF6 tank: IP 67 (ii) Front cover: IP 2X (iii) Cable cover: IP 3X (iv) Enclosure IP 54 complete all as specified and directed. with the standard following equipment: - (i) Earthing switches (ii) Operating mechanisms with integral mechanical interlocking (iii) Operating handle (iv) Facilities for padlocks on all switching functions (v) Bushings for cable connection in front with cable covers (vi) Manometer for SF6 -pressure/density monitoring (vii) Lifting lug for easy handling (viii) All units are designed for the subsequent fitting of an integral remote control and monitoring unit (ix) Colours: (a) Front cover: RAL 7035 (b) Side and cable cover: RAL 7035 (c) Enclosure IS 632 (x) Pressure of SF6 gas: 1.4 bar at 20 °C (xi) Impulse withstand voltage: To earth and between phases: 125 kV, Insulation level: Power frequency 1 min: 50 kV
Supply, installation, testing and commissioning of outdoor type, stepdown, copper wound transformer 2000 KVA, 22KV / 0.433KV, BIS Level-II, ONAN cooled, oil immersed, conforming to specification EEL-2 of IS : 1180-2014 with amd. no. 1,2,3 & 4. Formerly EEL-3 (till 30.3.2022), complete with first filling of IS:335, ISI marked, filtered & dehydrated transformer oil and other standard fittings/accessories and offload tap changer complete all as specified and directed. and comprising fo the following accessories: - (i) HV cable box (ii) LV Cable Box (without Cable Glands) (iii) Buchholz Relay (having Contacts for Alarm & Trip) (iv) OTI (having Contacts for Alarm & Trip) (v) WTI (having Contacts for Alarm & Trip) (vi) Marshalling Box (having TTB Only) (vii) Lifting Lugs, Top Cover Lugs (viii) Earthing Terminals (viii) Conservator with Oil Gauge Glass, Oil filling hole with Plug and Drain plug (ix) Transformer Drain Valve (x) Bi Directional Plain Rollers (xi) Explosion Vent with Diaphragm (xii) Thermometer Pocket (xiii) Air Vent Plug (xiv) Silica Gel Breather (vx) Rating & Diagram Plate inspection cover terminal marking plate (xvi) Cooling Radiators (xvii) LV Neutral Bushing brought out for external earthing (xviii) First fill of EHV grade Transformer oil as per IS 335 (xix) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device. Note. (i) Transformer secondary side should be suitable to draw LT Bus Trunk (4000 Amp sandwich type rising mains).
(ii) Quoted rate shall be deemed to be included for "plinth with dimensions of 2.5 m (width) x 2 m (length) x 1.5 m (height) of foundation structure designed to support and elevate a transformer includig embedded anchor bolts or mounting brackets to secure the transformer, have cable entry and exit points for easy connection of power lines."
Supply, installation, testing and commissioning of outdoor type, step down, copper double wound transformer 100 KVA, 22KV / 0.433KV, energy efficient, confirming to Std. & Tolerance as Per IS-1180 (Part-1_2014), BIS Level-II, ONAN cooled, oil immersed, complete with first filling of IS:335, ISI marked, filtered & dehydrated transformer oil and other standard fittings/accessories and Off Load Tap Changer with AVR & RTCCP complete all as specified and directed and comprising of the following: - (i) Lifting Lugs, Top Cover Lugs (ii) Earthing Terminals (iii) Conservator with Oil Gauge Glass, Oil filling hole with Plug and Drain plug (iv) Transformer Drain Valve (v) Bi Directional Plain Rollers (vi) Explosion Vent with Diaphragm (vii) Thermometer Pocket (viii) Air Vent Plug (ix) Silica Gel Breather (x) Rating & Diagram Plate inspection cover terminal marking plate (xi) Cooling Radiators (xii) LV Neutral Bushing brought out for external earthing (xiii) First fill of EHV grade Transformer oil as per IS 335 (xiv) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device. Note: Quoted rate shall be deemed to be included for "plinth with dimensions of 2.0 m (width) x 2 m (length) x 1.5 m (height) of foundation structure designed to support and elevate a transformer includig embedded anchor bolts or mounting brackets to secure the transformer, have cable entry and exit points for easy connection of power lines."
Supply, laying, testing and commissioning Aluminium HT Cable 22 KV (Earthed), 3 core 120 Sqmm, Stranded Compacted Circular Aluminium Conductor (A2XFY), Conductor Screen with Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with Extruded Semi Conducting Compound in Combination with Copper Tape, Cores Laid Up, Inner sheath of PVC, Galvanised Steel Flat Strip Armoured, & Overall PVC Sheathed Cable Conforming to IS 7098 (Part-2) 2011 with upto Date Amendments complete all as specified and directed.
Supply, laying, testing and commissioning Aluminium HT Cable 22 KV (Earthed), 3 core 95 Sqmm, Stranded Compacted Circular Aluminium Conductor (A2XFY), Conductor Screen with Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with Extruded Semi Conducting Compound in Combination with Copper Tape, Cores Laid Up, Inner sheath of PVC, Galvanised Steel Flat Strip Armoured, & Overall PVC Sheathed Cable Conforming to IS 7098 (Part-2) 2011 with upto Date Amendments complete all as specified and directed.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete Includes all necessary components such as lugs, insulating tubing, and sealing materials suitable for size 120 sqmm, 3 Core, XLPE aluminium conductor cable of Voltage Rating suitable for 22 kV systems, ensuring safe and efficient operation, complete all as specified and directed.
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete Includes all necessary components such as lugs, insulating tubing, and sealing materials suitable for size 120 sqmm, 3 Core, XLPE aluminium conductor cable of Voltage Rating suitable for 22 kV systems, ensuring safe and efficient operation, complete all as specified and directed.
Supplying and making straight through joint with heat shrinkable jointing kit complete Includes all necessary components such as lugs, insulating tubing, and sealing materials suitable for size 120 sqmm, 3 Core, XLPE aluminium conductor cable of Voltage Rating suitable for 22 kV systems, ensuring safe and efficient operation, complete all as specified and directed.
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete Includes all necessary components such as lugs, insulating tubing, and sealing materials suitable for size 95 sqmm, 3 Core, XLPE aluminium conductor cable of Voltage Rating suitable for 22 kV systems, ensuring safe and efficient operation, complete all as specified and directed.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete Includes all necessary components such as lugs, insulating tubing, and sealing materials suitable for size 95 sqmm, 3 Core, XLPE aluminium conductor cable of Voltage Rating suitable for 22 kV systems, ensuring safe and efficient operation, complete all as specified and directed.
Supply and fix HT 22 KV outdoor type gang operated polymer air-break switch suitable for horizontal or vertical mounting fixed type, double stack type, complete with 9 insulators of continuous current rating 200 Amps, rated short time withstand current for one second 16 kA rms, Reaed peak withstand curent for one second 40 kA (Peak), conforming to relevant IS. IEC 62271-103 amended upto date, with Electrolytic hard drawn tinned copper male & female contacts, cross section area of fixed contact 300 sqmm (Min), cross section area of moving contact 250 sqmm (Min), GI operating pipe 32 mm outer dia, class B, 6 meter length, flexible tinned copper braided tape including terminal bracket, operating horizontal (Solid) square rod 25x25 sq mm, GI oerating handle with nut bolts and washers etc complete all as specified and directed.
Supply and fix HT 22 KV outdoor type gang operated polymer air-break switch suitable for horizontal or vertical mounting fixed type, double stack type, complete with 9 insulators of continuous current rating 400 Amps, rated short time withstand current for one second 16 kA rms, Reaed peak withstand curent for one second 40 kA (Peak), conforming to relevant IS. IEC 62271-103 amended upto date, with Electrolytic hard drawn tinned copper male & female contacts, cross section area of fixed contact 300 sqmm (Min), cross section area of moving contact 250 sqmm (Min), GI operating pipe 32 mm outer dia, class B, 6 meter length, flexible tinned copper braided tape including terminal bracket, operating horizontal (Solid) square rod 25x25 sq mm, GI oerating handle with nut bolts and washers etc complete all as specified and directed.
Supply & Fixing in repair distribution lightining arrestor suitable to nominal system voltage 22 KV, highest system voltage 24 KV, rated voltage of arrester 18 KV rms, As per minimum line discharge capability conforms to Class 2 of IEC 600994 & IS 3070 (Part-3) amended upto date , nominal discharge current 10 KA (Peak) with all fittings bolts nuts and washers etc, complete all as specified and directed.
Supply and fix Polymer double stack channel type pin insulator's Drop Out fuse, nominal system voltage 22 KV, highest system voltage 24 KV, 6 insulators (Number of insulators for pole 2 Nos), current rating 200A/400A, complete all as specified and directed.
Supplying and fixig cable route marker with 10cm x 10 cm x 5 mm thick GI plate with inscription here on, bolted or welded onto a 35 mm x 35 mm x 6 mm angle iron, providing a sturdy and reliable framework, the angle iron is 60 cm long, ensuring adequate height and visibility when installed, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core conforms to as per IS 7098 (Part 1) 1988 with upto Date Amendments, complete all as specified and directed..
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core conforms to as per IS 7098 (Part 1) 1988 with upto Date Amendments, complete all as specified and directed..
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm 3.5 core conforms to as per IS 7098 (Part 1) 1988 with upto Date Amendments, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core conforms to as per IS 7098 (Part 1) 1988 with upto Date Amendments complete all as specified and directed.
(c) MCCB 4P, 63A, 25 KA,415V, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 Nos. (d) suitable to draw Bus trunk system from outgoing ACB's and LT cable from MCCB's. (e) Panel mounted type digital multifunctional energy meter A, V,Z, KW, PF T operated, LT 3 Phase, 4 wire inclding CT ration 100/5 - 04 Nos, (f) Control MCB 'C' curve, SP, 6 to 32A, 10KA, 'C' Curve - 04 Nos (g) LED phase indicator (R,Y & B) - 01 Set.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant, System Luminous Efficacy 120 lm/ W (Min) complete with driver and lamp, Operating voltage range: 140 V - 270 V, Average life of 50000 hours, complete all as specified and directed.
Supply and fix pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of size 300 x 200 x 105mm (internal) comprising of 63A power terminal block 4 ways, One No SP MCB single pole of capacity 6 amps, 'C' curve, 240 volts, 10 KA duly fixed on DIN rail 'C' type and one No. terminal for loop in & loop out suitable for three phase street light system including nuts, bolts and wahsers, MS clamp fabricated from 25x3mm flat iron mounted on pole complete all as specified and directed.
Supply and fixing of 50 mm dia x 1.5 metres long GI pipe (Medium grade) bracket for mounting of street light fitting on pole including bending the pipe to the required shape, 2 Nos 40mm x 3mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and paint etc complete all as specified and directed.
Supply and fix steel tubular swaged poles type 410 SP-22 (8.5 m long) complete with CI base plate and finial including foundation and coping , including painting with anti corrosive paint internally complete and externally up to planting depth, alternative white & black strips of 30 cm width upto 1.5 m above ground level, complete all as specified and directed.
Material and labour for maintenance free Chemical bore Earthing of Dual Pipe technology of 3 m long with Outer pipe Diameter of 88 mm & inner pipe diameter 48 mm, the pipes outer is properly galvanized for 80-120 micron and Wall thickness of inner pipe 3.0 mm and 2.0 mm of outer pipe. There should be terminal for connection of 75 X 6.0 mm with two holes of 14mm diameter. Electrode is duly filled with the highly conductive material with sealing at both ends with lead terminal of 75 X 5.2 mm at top. The electrode shall be duly tested & certified by CPRI (Central Power Research Institute), Govt. Of India for a minimum short circuit current of 42 kArms for 1 Second with initial pick of 88.2 kA. The Electrode is tested in MSME Govt of India. The Electrode is tested for salt spray testing as per B 117-09 for corrosion for minimum 500 hours from NABL accredited lab CHEM .T 298 /& MECH.T 299 & ISO/IEC 17025 accredited material testing lab, Supply of earth enhancing Compound 2 Bags of 25kgs each. The chemical compound should be tested and certified by any International accredited and BIS (Bureau of Indian Standards) accredited laboratory.The testing laboratory should be ISO 9001 & ISO 14001 certified. The earth enhancing compound should be tested referring to protocol IS 1350 & IEC62321/111/54/CDV. The pH value of compound should be between 7 to 8.(i.e. basic in nature) The content of mercury (Hg) & Hexachromium should be below detection level. (i.e. Non Toxic Compound) including necessary boring in ground of 150 / 200mm dia in any type of strata connecting to test point including provision of chamber cover complete all as specified and directed.
Material and labour for special factory made Pure Copper Single Pipe earthing, the pipe dia is of 76 mm Pipe, & wall thickness of pipe is 2.0 mm & the cavity is filled with highly conductive, non?corrosive material along with supply of Fast Electrode Earth Enhancing Compound 2 Bag of 25 Kgs. The Earth Enhancing Compound should have Test certification from NABL accredited Lab. It should be tested as per IS 1350/ AHPA guideline’s. The pH value of Compound should be 7.59, Moisture % by mass should be 8.91& Solubility in 1:1 HCL should be 32.29 %. The Compound should have test certification ELV Test as per protocol IEC 62321/111/54/CDV/ICP-OES for contains of Lead (23.0 ppm), Cadmium (15.0ppm), Mercury (Below Detection Level) & Hexa-chromium(Below Detection Level). The manufacture of Earthing should be registered under Udyam registration and certified for ISO 9001:2015 including necessary boring in ground of 150/200 mm dia in any type of strata connecting to test point including provision of chamber cover complete all as required
Notes: (i) The earth resistance shall be less than 1 ohms. (ii) Contractor shall improve the desired earthing resistance within the permissible limit without any extra cost.
M&L for providing and laying GI tape of durable and corrosion-resistant, ideal for use in earthing systems, cross sectional area of 32 mm width and 6 mm thickness, ensuring effective current dissipation and mechanical strength, the tape is laid directly in the ground, securely connected to the earth electrode, and buried at a depth as per safety standards complete all as specified and directed.
Supply & fixing copper strip is of high conductivity and corrosion resistance, ensuring reliability for earthing applications, the strip has a cross-section of 32 mm width and 6 mm thickness, the strip is buried in the ground according to the required depth and alignment, ensuring effective dissipation of fault currents complete all as specified and directed.
Earth work in excavation in all kinds of soil by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, complete all as specified and directed.
Excavation of the cable trenches in hard rock not exceeding 1.50 m in width, and lift upto 1.5 m, including getting out the excavated soil and disposal of excavated soil as diretced within a lead of 50 m, complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover, Classified as HVP (High Voltage Protection), type 2, with a peaked design for added strength and visibility, size 300 mm (length) x 180 mm (width) x 40 mm (thickness)(ISI Marked), suitable for standard cable protection needs, complete all as specified and directed.
Supply, spreading, leveling and well ramming in layers not exceeding 20 cm in height stone-crushed Sand filling under floors, cable trenches or in foundations, each layer is well rammed and watered to achieve proper consolidation and density, complete all as specified and directed.
Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m, complete all as specified and directed
Supplying, installing by overhead, testing and commissioning of 4000A, Isc-50KA for 1 sec capacity sandwich type Rising mains for use on 3 phase wire 415 volts, 50 Hz A.C. Supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6 mm thick steel sheet duly powder coated in convenient section complee with 4 Nos aluminium bus bars having current density of 130A/Sq cm at nominal current rating, necessary joints, elbow joints & expansion joints an bends, fire barrier, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping bracket, suspenders, angle iron bracket, MS supporting channel, ms clamps, steel fasteners, connecting to earthing system etc. complete all as specified and directed. Note. MS square bar, MS clamps, steel fastners will be measured and paid separately.
Supply and fixing in repair Automatic Street Light Switch using astronomical switch for Street lights based on LUX level of Natural Light. The Sensor (Nature Switch) along with suitable three phase, Power Contactor 32 Amps, MCB TPN 40Amps, 'C' curve, 10 KA and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof conforming to IP54 and FRLS internal wiring, in-built short circuit protection. The Contactor, MCB and Circuit Wiring should suitable enough to take load of 6 kW three-Phase load complete all as speified and directed.
Supply and laying synthetic Rubber insulated mats 19 mm thick for voltage upto 22 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety, ISI marked, of sizes 2m x 1m complete all as specified and directed.
Supply and lay Electric rubber hand gloves made from high-grade rubber, offering flexibility, durability, and resistance to wear and tear, ISI marked, Certified as per Indian Standards (IS:4770), 22 KV complete all as specified and directed
Supply and fix fibre glass discharge rod 20 feet, providing sufficient reach for safe operation, divided into three sections for easy portability and assembly, made of fiberglass, ensuring high insulation, durability, and resistance to environmental factors and equipped with an Aluminum head for effective discharge and durability suitable for 22 KV operation complete all as speified and directed.
Supply and fixing 16 m long, providing wide-area illumination, High galvanized mast light accommodates 9 lanterns symmetrically fitted, ensuring uniform light distribution along with their control gear and equipped with a two-point suspension system using a 6 mm diameter stainless steel wire rope (97/19 gauge) for stability and durability and Includes a double drum winch for smooth and efficient raising and lowering of the lantern carriage, a luminaire mounting arm and pulley assembly for secure and adjustable installation, aviation obstruction light, lightning arrester spike for added safty including RCC (Reinforced Cement Concrete) foundation for stability and long-term durability as per height, powered by a 3-phase electric motor, ensuring efficient and reliable operation complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core conforms to as per IS 7098 (Part 1) 1988 with upto Date Amendments complete all as specified and directed.
Supply, install, testing and commissioning of weather proof LT panel indoor type made out of CRCA sheet 2 mm thick, cubical type factory made with front opening type free standing, suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply having 4 Nos aluminium bus bars of 4000 amps capacity duly insulated with heat shrinkable colour coated sleeve complete, painted with powder coated with locking arrangement, mounted on MS agnle bae frame of size 75 x 75 x 6mm including grouting in PCC. The LT panel povided with the following accessories complete all as specified and as directed :- (a) Microprocessor based Air Circuit Breaker (ACB), manual draw out type 4 pole, 2500A, 415V, 75 KA, 50 Hz - 01 No. Outgoing: (a) MCCB 4P, 400A, 50 KA,415V, thermal magnetic release, AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 07 Nos, (b) MCCB 4P, 630A, 50 KA,415V thermal magnetic release - , AC supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 Nos, (c) Panel mounted type digital multifunctional energy meter A, V,Z, KW, PF T operated, LT 3 Phase, 4 wire inclding CT ration 100/5 - 10 Nos, (d) Control MCB 'C' curve, SP, 6 to 32A, 10KA, 'C' Curve - 02 Nos, (e) LED phase indicator (R,Y & B) - 10 Set.
Supply and drawing 3 x 2.5 sqmm size of FRLS PVC insulated copper conductor, single core cable, the cable is drawn through existing surface/recessed steel or PVC conduits, or within existing steel swaged poles, as required.
Supply, installing, testing and commissioning of silent Diesel Engine Drives Generating Set, 415 Volts, 40 KVA (32KW), 3 Phase, 4 wire, 0.8 Power Factor, 50 Hz, 1500 RPM, radiator cooled engine, self excited, self regulated brushless AC generator suitable for ambient conditions complete with sound proof canopy as per CPCB IV norms, with battery, Control panel for automatic starting on main failure installed on cement concrete foundation as per recommendation of manufacturer and 60 cm above ground level complete all as specified in description given below and directed. (a) Diesel Engine : Diesel engine suitable BHP at 1500 RPM multi cylinder 4 stroke, water cooled, Electrical starter motor with soft start engagement feature, Coolant heater, Oil drain pump, Heavy duty air cleaner, Electronic Governing, Optimised turbocharger for increased altitude capabilities, Standard integral set-mounted radiator system, designed and tested for 50°C ambient temperature etc and ARAI approved capable of taking 10% over loading. The engine shall be fitted complete with all the required accessories.
(b) Control panel shall be manufactured with 2 mm thick CRCA sheet and powder coated for weather-proof and long lasting finish. The control panel consists of the following parts :- (i) Microprocessor based generator set monitoring and control system. This control includes an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration and diagnostics. Intuitive operator interface which includes LED backlit LCD display with tactile feel soft-switches and generator set status LED lamps, Remote Start-Stop, Engine Metering : Oil pressure, Engine temperature, Starting battery voltage, Engine running hours, AC Alternator Metering : L-L Voltage and L-N Voltage, Current (phase and total), kVA (phase and total) and Frequency. Engine Protection : Low lube oil pressure, High/Low coolant temperature, Battery Over/Under/Weak Volts, Fail to Crank/ Start, Sensor failure, Cranking lockout, Low fuel level. AC Alternator Protection : Over/Under Voltage, Over/Under Frequency, Loss of AC Sensing. Data Logging : Engine Hours, Control Hours and upto 5 recent fault codes Configurable glow plug control, 12 Volt DC operation, Sleep mode, Modbus interface (RS485 RTU), InPower compatible (PC based service tool).
(ii) Automatic starting on mains failure (AMF Panel) as per the manufacturer standard practice and specification complete with Aluminum bus bars of suitable capacity of incoming/outgoing terminals, Indicating lamps for ‘Load ON’ and ‘Set Running’. (iii) Instrument fuses duly wired and ferruled. (iv) Circuit breakers of suitable rating with overload and short circuit protections. (c) Alternator : Synchronous alternator rated at 40 KVA, 415 Volts at 1500 RPM 3 phase 50 Hz, AC supply, Brushless type, Screen protected, Revolving field, Self excited alternator conforming to IS/IEC 60034-1, Compact design with sealed bearings and ƒImpregnation on all wound components suitable for tropical conditions and with class F/H insulations. (d) Mounting Arrangement : Engine and alternator shall be mounted on a common MS fabricated base frame with AVM pads. Base frame with integral fuel tank shall be provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning. (e) Fuel Tank : Daily service fuel tank of capacity as per manufacturer standard specification fabricated out of MS sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class C pipe of suitable dia complete with valves. (f) Exhaust System : Dry exhaust manifold with hospital exhaust silencer and catalytic converter.
(g) Starting System : 12V/24V starting system comprising of starter motors, voltage regulator and arrangement for initial excitation complete with suitable Nos of batteries (lead acid type) as required as per specification. (iii) Instrument fuses duly wired and ferruled. (iv) Circuit breakers of suitable rating with overload and short circuit protections. (h) Acoustic Enclosure : Specially designed to meet stringent CPCB norms of 75 dBA @ 1mtr at 75% load under free field conditions. The acoustic enclosure is made of CRCA sheets and a structural/ sheet metal base frame painted in black, High quality noise absorbent and fire-retardant grade acoustic Insulation material (Foam) complying to IS 8183, Two point lifting for easy handling, Air inlet louvers specially designed to operate at rated load, 11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme environment, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling arrangement inside the enclosure etc. Note : PCC and earth work for DG set foundation, cable connection with glands and lugs shall be deemed to be included in quoted rates
Removing excavated material, transported and deposited not exceeding 50 metres from the excavation site and the deposit should not exceed 1.5 meters above the level of the starting point complete all as specified and directed.
Supply and fixing MS channels, MS clamps, steel fasteners etc complete all as specified and directed.
Shree Ayyappa Engineering (BID ID -3324864)
Leo Air and Power Solution pvt Ltd. (BID ID -3325259)
R D Bansal (BID ID -3325038)
Vijaypower Generators Limited (BID ID -3325487)
SHRI GANESH ENTERPRISES (BID ID -3324279)
M/s Prem Associates (BID ID -3324605)
NATIONAL ENGINEERING CORPORATION (BID ID -3325309)
Shri Sai Electricals (BID ID -3322510)
UNIQUE ENGINEERS (BID ID -3325247)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .