Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹10.4 L
Closing Date
28 Aug 2021, 5:00 pmClosed
Nodal Officer
e Procurement Cell,BCD,Jharkhand,Ranchi
Proposed Construction of SDO Cum SDPO Residential and A,B,C,D Types Quarter and Police Barrack at Simaria Chatra, Jharkhand
2021_BCD_50930_1
BCD/Chatra/03/2021-22
Open Tender
Civil Works - Buildings
545 days
Simaria, Chatra
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
EE,BCD,Building Division,Chatra
₹10.4 L
5 Oct 2021
7 Aug 2021
31 Aug 2021
7 Aug 2021
28 Aug 2021
7 Aug 2021
Amount
Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I.
Extra for earthwok in hard soil as per specification and direction of E/I. (Vide classification of soil item - B).
Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode measurement compacted Volume).
Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, rotalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume).
Providing designation 75B work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 75 B work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints of screening materials, scaffolding, ranking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Extra for brick work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/I.
2nd Floor
3rd Floor
Providing designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 112mm thick reinforced designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carraige of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforced) all complete as per building specification direction of E/I.
Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level.
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40mm nominal size)
1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 40mm nominal size)
1:4:8 (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40mm nominal size)
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to Plinth Level- 1:1.5:3 (1 cement ; 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string course, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reionforcement : (1:1.5:3 (1 cement : 1.5 : coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15" landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, fotting, bases of columns, etc. for mass concrete
Suspended Floors, roofs, landings, balconies and access platform
Shelves (Cast in situ)
Lintels, beams, Plinth beams, girders, bressumers and cantilevers
Column, Pillars, Piers, Abutments, Posts and struts
Stairs, (Excluding landings) except spiral-staircases
Weather shade, Chajjas, corbels etc. including edges
Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all complete as per building specification and direction of E/I.
Supplying, fitting & fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with aluminum fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
S/F 35mm solid core type Non decorative single leaf flush door shutter with both sides decorative with black core standard make with aluminum fittings such as hinges, tower bolst, hanlde, cleats and sand block taxes all complete a per building specification and direction of E/i.
Supplying, fitting and 35mm thick solid core non-decorative duble leaf flush shutters in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneered of standard make with oxidised iron fittings - do -
Supplying, fitting & fixing 30mm thick solid core type non-decorative double leaf flush shutter in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneeres of standard makew with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
Supplying, fitting & fixing glass panes including supplying putty, beads and after taking out old and broken glass panes and disposal of debris all complete as per building specification and direction of E/I.
Providing Toe steel reinforcement of following dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel)
8mm (TMT coil Fe 500) (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel)
10mm (TMT coil Fe 500) (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel)
12mm to 25mm (TMT coil Fe 500) (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel)
S/F M.S. grill made of 20 x 6mm M.S. flat as per approved designious fillet welded and finished smooth, hoisting carriage of grill to worksite hoisting as per building specification and direction of E/i.
Providing and fixing fan hook of 16mm dia TMT M.S. bar I meter long bent to required size and shape placed in position and fixed in RCC slab/beam at the time of casting all complete as per building specification and direction of E/I.
S/F local make collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat disgonal with top and bottom rails of T iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts nuts locking arrangements steppers handles including applying a priming coat of red lead paint carriage hoisting and taxes all complete as per building specification and direction of E/I.
S/F local make fully glazed steel door, windows or ventilation of standard rolled 'Z' and mullion steel section and size as per IS - 38 joints met welded with 100 x 16 x 3mm M.S. lug fixed in cement concrete (1:2:4) blocks, 15 x 10 x 10cm size including cost of oxidized iron fitting with hinges, handle per step catch springs, 3mm thick plain glass panes with aluminum beads and inner frame fixed with lugs with 20mm long 6.3mm GI. counter sunk machine screw and nuts and applying a coat red lead paint carriage to work site hoisting and plcing in all position in all storys and taxes all complete as per building specification and direction of E/I.
S/F 35mm dia G.I. pipe fitted and fixed in floor outlet to drain out water in cement concrete including cutting hole making good the wall and finishing, all complete as per building specification and direction of E/I.
Supplying, fitting and fixing 20 guage G.C.I. sheet fitted on M.S. Angle frame of size 60 x 60 x 6mm including cost of fabrication, providing necessary locking arrangement with haskal and dommy duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
S/F M.S. grill gate with M.S. grills made of 20 x 6mm M.S. flats or 16mm M.S. square bars fitted on 25 x 5 x 6mm M.S. angleframe of size 60 x 60 x 6mm including cost of fabrication, carriage to site.
Providing designation 75 B one brick flat soiling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
Providing 50mm thick cement concrete flooring (1:2:4) with 20mm to 6mm size graded stone chips finished with flooring coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/I.
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 with Floating Coat of neat cement in skirting including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing and laying 15mm to 23mm thick kotah stone tiles in risers of step, skirting and pillars of approved size texture and colour laid over 12mm thick cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing to granolilthic finish with approved quality of carborandom stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
Extra for flooring work for each consecutive floor above first floor complete as per direction of E/I
Providing and laying Double charge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622/ISO 13006 of approved make in all colours and shades laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement alurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. complete Size of Tile 600 x 600 mm
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.Outside Plaster
Providing 12mm thick cement plaster (1:6) -with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty as per building direction of E/I. Inside Plaster
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curring with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 1.5mm cement punning including curing carriage of water with all leads and lifts as per building specification and direction of E/I.
Prociding 19mm thick water proof cement (1:3) with clean coarse sand of F.M. 1.5 including screening curing with all leads lifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Prociding 25mm thickwater proof cement (1:4) with clean coarse sand of F.M. 1.5 including screening curing with all leads lifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Extra for plaster work over exterior surface for each consecutive floor above first floor including cost of scaffolding etc. all complete as per direction of E/I.
2nd Floor
3rd Floor
Making 6 x 6mm grooves in plaster surface over walls truly horizontal or vertical as specified at regular intervals at all height including cleaning, finishing scaffolding and curing with all leads and lifts of water all complete as per building specification and direction of E/I.
Providing two coats of oil Bound Distemper of approved shade and make over a coat of cement primer over new surface, including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification & Direction of E/I.
Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/I.
Providing two coats of synthetic enamel paint over a coat of primer of approved shade and make over new wooden surface after cleaning, removing dirt, scales, smokes, grease and sand papering including cost of scaffolding, curing and taxes all complete as per building specification & Direction of E/I.
Providing one coat of wax polishing with mansion, waxpol or equivalent approved quality of wax polish over old or new wooden surface, including cleaning the surface after removing dirt, scales, grease and sand papering, including cost of scaffolding & Taxes all complete as per building specification & Direction of E/I.
Providing primer one coat of red lead paint of approved make over steel surface including preparing the surface after cleaning removing dust, dirt. Scales amokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (mode of measurement of area shall be multiple by the co-efficient as indicated in building specification)
Providing two coats of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface througly coast of scaffolding and taxes all complete as per specification and direction of E/I.
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification & Direction of E/I.
Providing 250mm wide brick drain in cement mortar (1:6) with as. 150mm clear depth and 250mm apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
Water proofing for old and New Roof Slab : - Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specifications with following steps:-
Surface preparation :- Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint/coating and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt. Ltd/MYK schomberg/Dr. Fixit/fosroc or equivalent. Proiding and reparing of all corners and joints such as those between the parapet wall and the roof slab etc. shall be chamfered with 150mm x 150mm fillet of mortar (Cement sna - 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr. Fixit or equivalent.
Before chamfering surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.
1st coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600mm by brush or roller. After 1st coat of application, 45 gsm of fibre glass cloth to lay when the first layer is still green, 1st coat should be applied @ 1.50 kg/sqm/coat. For the purpose of measurement the entire treated surface will be measured.
2nd Coat :- To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @ 0.7 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured. After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be doen as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing coating to be protected from damage before screed over it. Water proofing Brand-Sika Topseal 109hi/Fosroc Brushbond RFX/Dr Fixit Pidifin 2K/MYK Auafin TG, Product Performance - chemical
Base part A : Acrylic copolymer, Part B : Specially graded cementtitious powder - Density 1.6 kg/l (mixed density) at +270C Tensile strength ~ 2N/mm2 after 28 days (with Fibre cloth) (according to ASTM D 2370) Pullout Bond Strength ~ 2 N/mm2 (concrete failure) (According to ISO 4624) Slant-shear bond strength~4 N/mm2 (According to FIP 5.15) Elongation at Break ~ 35% without Fibre Cloth and 20% with fibre cloth (According to ASTM D 2370)
Protection of treatedsurface with PCC : - The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 Mt x 2mt keeping 6mm gap between the panel joint intergal water proofing admixture conforming to IS 2645 @ of 100 ml per bag of cement to be added in the acreed concrete (paid separately for this items) all corners shall be chamfered with 150mm x 150mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between PVC pipe outlet and concerte surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insentive epoxy putty of Sika India pvt Ltd/MYK Schomberg/Dr. Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured."
Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately) Brand - Sika India Pvt. Ltd./MYK Schomberg/Dr. Fixit/Fosroc. Warantly for five years.
Covering of treated surface with PCC :- Providing 50mm thick cement concrete M-20 (1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with approved quality of stone chips of 20mm to 6mm size graded and cleaned sand of F.M. to 3 including screening, shuttering and mixing cement concrete in mixer with admixture in integral water proofing and placing in position, skirting curing, taxes and roaylty all complete as per building specification and directions of E/I. Panels that has been left should be casted next day. There should be 6mm gap between Panels Brand-Sika-plastocrate plus, MYK proof WP 10, Fosroc-Conplast X 4211C, Dr. Fixit Pidproof LW+ or equivalent.
Providing 25mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with integral water proofing compound Liquid @ 125ml per bad cement including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. Brand - Dr. Fixit Pidiproof LW+ Sika-Plastocrate plus, MYK proof WP 10,Fosroc - Conplast X4211C or Equivalent.
Providing and filling of 6mm thick Groove between 50 mm PCC Panels with Polysulphide Sealant (Poring Grade) as per drawings and technical specifications and direction of E/I. (with 18% GST) Brand - Sika-Polysulphide, Forsoc-thioflex 600, Dr. Fixit Pidiseal PS (42P, MYK Seal PS or Equivalent.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over75mm thick bed of dry brick ballast 40 mm nominal size, well rammedand consolidated and grouted with fine sand, including finishing the topsmooth.
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars atevery third course of half brick masonry.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Udaypur green Marble - Area of slab upto 0.50 sqm
Udaipur green marble- Area of slab over 0.50 sqm
Granite of any colour and shade - Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge Granite work.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make,in all colours, shades except burgundy, bottle green, black of any size asapproved by Engineer-in-Charge, in skirting, risers of steps and dados,over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) andjointing with grey cement slurry @ 3.3kg per sqm, including pointingin white cement mixed with pigment of matching shade complete
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 25 mm thick (for cupboard) including ISI marked nickel platedbright finished M.S. Piano hinges IS : 3818 marked withnecessary screws
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :
2nd class teak wood - 50x12 mm
2 nd class teak wood -50 mmx20mm
Providing and fixing PVC rigid foam sheet 1 mm thick on existing doorshutters (bathroom and W.C. doors) using synthetic rubber basedadhesive.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Providing and fixing pressed steel door frames confirming to IS : 4351 manufactured from commercial mild steel sheet of 1.25mm thickness including hinges jamb, lock jamb bead and if required angle threshold of mild steel angle of section 50 x 25mm, or base ties of 1.25mm pressed mild steel welded or riidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after-treatment of the surface as directed by Engineer-in-Charge. Profile B - Fixing with adjustable lugs with split end tail toeach jamb
Providing and fixing circular/hexaganol M.S. Sheet ceiling fan box with clamp of internal dia 140 mm, 73 mm height 3 mm thick rim, top and bottom lid of 1.5 mm M.S. box by means of 3 mm round head screws, clamps shall be made of 12 mm dia M.S. bar bent to shape as per standards drawing with over all length as 80 cm.
Steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. As required. In gratings, frames, guard bar, ladder, railling, brackets, gates and similar works.
Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishingand making curvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete, i/c fixing the railingwith necessary accessories & stainless steel dash fasteners , stainlesssteel bolts etc., of required size, on the top of the floor or the side ofwaist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
Chequered precast cement concrete tiles 22mm thick in footpath and courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20mm thick bed of cement mortar 1:4(1 cement: 4 coarse sand) Dark shade using ordinary cement
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 25mm thick
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), including grouting the joints with white cementand matching pigments etc., complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matchingpigments etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying vitrified tiles in Skirting in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Providing and laying pressed clay tiles (as per approved pattern 20mm nominal thickness of approved size) on roofs jointed with cementmortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral waterproofing compound, laid over a bed of 20 mm thick cement mortar1:4 (1 cement : 4 coarse sand) and finished neat complete
Making Khurras45x45 cm with average minimum thickness of 5cm cement concrete 1:2:4 (1 Cement : 2Coarse sand : 4 graded stone aggregate of 20mm nominal size) over PVC sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3(1 cement : 3 coarse sand and a coat of neat cement rounding the edges and making and finishing the outlet complete as per building specification and direction of E/I.
Providing and fixing on wall face unplasticied Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion (i) Single socketed pipes.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Clamp - 110mm
Single pushfit Couplar - 110mm
Single tee with door - 75x75x75 mm
Single tee with door - 110x110x110 mm
Single tee without door - 75x75x75 mm
Single tee without door - 110x110x110 mm
Bend 87.5° - 75mm
Bend 87.5° - 110mm
Shoe - 110mm
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mmhard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm dia meter and waiting not less than 440 gms.
Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm overand including priming coat of exterior primer applied @ 2.20kg/ 10 sqm)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10sqm over and including priming coat of exterior primerapplied @ 2.20 kg/ 10 sqm)
Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Providing and laying 80 MM th. factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/ shape laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand etc. all complete as per the direction of E/I. 80 mm thick C.C. paver block of M-30 grade with approvedcolor design and pattern.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion - Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) - Powder coated aluminium (minimumthickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight notless than 10 kg/ sqm)
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
Providing and laying water proofing treatment in sunken portion ofWCs, bathroom etc., by applying cement slurry mixed with waterproofing cement compound consisting of applying : a) First layer ofslurry of cement @ 0.488 kg/sqm mixed with water proofing cementcompound @ 0.253 kg/sqm. This layer will be allowed to air cure for4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixedwith water proofing cement compound @ 0.126 kg/sqm. This layerwill be allowed to air cure for 4 hours followed with water curing for48 hours. The rate includes preparation of surface, treatment andsealing of all joints, corners, junctions of pipes and masonry withpolymer mixed slurry
65X65X6 mm Angle Size as per I.S 226
Stainless steel wire guage (Grade-304) aperture 1.4 mm and 0.50mm dia wire
Granular sub-base with coarse Graded Material (400-2) (Construction of granular sub base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with viberatory roller to achieve the desired density, complete as per clause 401), (Rate = RCD, 2016, Inclusivs carriage) - for gading - I Material
Providing & fixing at or near ground level precast cement concrete in kerbs, edging etc. as per approved pattern & setting in position with cement mortar 1:3 including the cost of required centering, shuttering & finishing smooth with 6mm th. Cement plaster 1:3 on exposed surface complete.
Carriage of materials by diesel Truck including loading at source, unloading at works site and stacking properly, labour, P.O.L., etc. all complete as per direction of E/I.
Bricks - 8km (1k + 7p)
Sand - 12km
Chips - 22 km
Metal - 22 km
Local Sand - 3 km
Fly Ash Brick - 15km
Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350 gms.) with extra socket all complere as per specification and direction of E/I.
Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I.
15 mm dia
20mm dia
Providing and fixing G.M. non-return valve Horizontal/Vertical type of approved quality as per specification and direction of Engineer-in-charge.
Horizontal - 25mm dia
Horizontal - 32mm dia
Vertical - 25mm dia
Vertical - 32mm dia
Providing and fixing 15mm dia and 45cm long PVC connection pipe with heavy quality brass coupling at both ends etc. all complete as per specification and direction of Engineer-in-charge.
Providing and fixing N.P/C.P. brass/P.V.C. porcelain shower rose of 15mm inlet etc. all complete as per specification and direction of E/I. 125mm dia C.P. shower
Providing & fixing 15mm size pillar cock C.I. body brass spindle pillar cock of approved quality as per specification & direction of E/I.
Providing and fixing Gun metal full way valve of approved quality all complete as per specification and direction of E/I.
20mm dia
25mm dia
32mm dia
Cutting chajja or cornice for laying G.I. pipe and restoring the same with R.C.C. (1:2:4) brick work in cement mortar (1:4) and cement plaster (1:4) as per specification and direction of Engineer-in-charge.
Making holes in walls for laying G.I. pipes and restoring the same after pipe laying as per specification and direction of E/I.
125mm thick wall
250mm thick wall
RCC Chajja
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.
Glass shelf with C.P. brass rail- 600 x 125mm glass shelf complete
Glass shelf with C.P. brass rail - 450mm x 125mm
Mirrors of 6mm thick glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror - 600mm x 450mm size
Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror - 450mm x 300mm
C.P. brass towel rail 20mm x 600mm with bracket container
C.P. brass soap dish container medium quality with screw and hinges etc.
C.P. brass liquid soap container
Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and dirction of E/I. 580mm long - With 10 liter low level PVC cistern
Supplying, fitting and fixing 40mm high viterous white glazed earthen E.W.C. with 'p' trap of Parry/hindustan or any other approved I.S.S. make including supplying and fixing 15 liters C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grams 15mm P.V.C. alkathene pipw 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead o commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approvd paint over a coat of red oxide priming, all complete as per specification and direction of E/I. Witl, "P" trap - 10 liters low level P.V.C. cistern
Supplying fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15mm dia C.I. body brass spindl stop cock approved quality of weight not less than 30 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of exacavted earth within initial lead and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I. For classification of soil item - A
Lbour for alying, fitting and fixing NP2 R.C.C. spun pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leakproof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complet as per specification and direction of E/I. 150mm dia RCC spun pipe - Upto 3.0 metre depth of invert below G.L.
Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.
Supplying and fixing NP2 Hume pipe etc. (150mm dia)
Supplying fitting & fixing special type of C.P. Bath room fittings for V.I.P. buildings (JAL, Jaquar, Marc or equivalent mark)
Bib cock (Long Thread)
Angular Stop Cock
Centrel Hole Besin Mixure (Best Quality)
Wall mixure with Provision for over head shower with elbow cupling and wall flange
Sink Mixure with swinging casted spout
Toilet Paper Holder
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink without drain board - 610x460 mm bowl depth 200 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
Providing and fixing PTMT grating of approved quality and colour. C.P. Gratings - Circular type - 100mm dia
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5
Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/G.I. boc etc. as required. Group A
Wiring for twin control light point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way piano type switch, phenolic laminated sheet, suita
Point wiring in PVC conduit, with modular type switch - Point wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required. Group B
Twin control point wiring in PVC conduit, with modular type switch - Wiring for twin control light point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch, modular plate, suitable size G.I. box etc. as required.
Wiring for light plug with 2 x 4 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC PVC conduit along with 1 Nos. 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for Circuit/submain wiring along with earth wire with the following sizes PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.
2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire
2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire
2 x 4.0 sq.mm. + 1 x 4.0 sq.mm. earth wire
2 x 6.0 sq.mm. + 1 x 6.0 sq.mm. earth wire
2 x 10 sq.mm. + 1 x 10 sq.mm. earth wire
2 x 16.0 sq.mm. + 1 x16.0 sq.mm. earth wire
4 x 6.0 sq.mm + 2 x 6.0sq.mm earth wire
4 x 10 sq.mm + 2 x10 sq.mm earth wire
Wiring in existing conduit - Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. 2 x 1.5 sq.mm.
Telephone wiring in existing conduit - Supplying and drawing following pair, 0.5 sq.mm FR PVC copper conductor, unarmoured telephone cable in the existing surface/recessed PVC conduit as required. 3 Pair
TV cable in existing conduit - Supplying and drawing co-axial TV cable RG-6 grade copper conductor, PE insulated, with PVC sheath in the existing surface/recessed PVC conduit as required.
S/F PVC conduit - Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required. 20 mm
Supplying and fixing following piano type switch/socket obn the existing switch box/cover including connections etc. as required.
5/6 amps, one way switch
3 pin 5/6 a,ps. Socket outlet
T.V. Anteena Shoket Outlet
Electronic step fan Regulator Deluxe
S/F Modular type switch socket - Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required
5/6 amps, one way switch
3 pin 5/6 a,ps. Socket outlet
Telefone socket outlet
TV antina shoket outlet
S/F Modular type electronic fan regulator - Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
S/F light plug point with piano type accessories - Supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic liminated sheet cover in front including providing and fixing 5 pin, 5/6 amps socket outlet and 5/6 amps piano tyep switch connection, painting etc. as required.
Supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic liminated sheet cover in front including providing and fixing 6 pin, 15/16 amps socket outlet and 15/16 amps piano type switch connection, painting etc. as required.
S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc. as required
S/F power plug point with Modular type accessories - Supplying and fixing suitable size G.I. box with modular plate cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc. as required.
Supplying and fixing 2 pin 5 amp. Ceiling rose on the existing junction box/wooden block including connection etc. as required
Supplying and fixing batten/angle holder including connection etc. as required
S/F Electronic musical call bell - Supplying and fixing electronic musical call bell suitable for D.C/A.C. single phase, 230 volts, complete as required.
Supplying and fixing call bell/buzzer suitable for D.C./A.C. single phase, 230 volts, complete as required.
Installation, testing and commissioning of resistance type ceiling fan regulator, in existing switch box including connection with 1.5 sq.mm. FR PVC insulated, copper conductor, single core cable as required.
Installation of exhaust fan up to 450mm sweeo in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required.
Providing and fixing following capacity double pole/TP & N sheet metal switch disconnector fusen unit in existing metal with rewireable type fuses, including drilling holes in metal board, making connections, etc. as required.
63 amps, double pole
100 amps, TP & N
Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body, etc. as required. 100 amps
Supplying and fixing following way single pole neutral, sheet, MCB disrtibution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator)
6way, single door
8 way, single door
12 way, Double Door
Supplying and Fixing TPN MCB DB: Supplying and Fixing of following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder including painting, earthing etc. as required( without MCB/RCCB/ISOLATOR). Make :- Havells / Standard / indoasian. 4+12 ways, double door Horizontal type (4 Way)
Supplying and fixing 6 amps to 32 amps rating, 240 volts, "B" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required. 6/32, single pole, "B" series
S/F DP MCB Isolator - Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
S/F four pole MCB isolator - Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioining etc. as required
Earthing with G.I. earth plate 600mm x 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. (but without charcoal or coke and salt)
S/L 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode including soldering etc. as required
P/F 25 x 5mm copper earth strip in pipe:- Providing and fixing 25mmx5mm cpper earth strip in 40mm & 2.5Mtr long G.I.pipe for earth electrode etc. as required.
P/F 25x5mm copper earth strip in surface/recess :- Providing and fixing 25mmx5mm cpper earth strip in surface/recess for connections etc. as required and making the earth grid for all copper earthing pits of the building.
P/ F 6 SWG G.I.. loop earthig wire in surface/recess:- Providing and fixing 6 SWG dia G.i wire on surface or in recess for loop earthing as required.
P/F G.I. lightning conductor final - Providing and fixing of lightning conductor final, made of 25mm dia 300mm long, G.I. tube, having single prong at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required.
Fixing of lighting conductor final, made of 25mm dia 300mm long, copper tube
Reverting, sweating and soldering of copper/G.I. tape (With another copper/G.I. tape, basae of the final or any other metallic object) as required.
P/F G.I. lightning conductor tape in horizontal run - Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
P/F G.I. lightning conductor tape in vertical run - Provding and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
P/F Testing joint G.I. lightning conductor - Providing and fixing testing joint, made of 20mm x 3mm thick G.I. strip, 125mm long, with 4 nos. of G.I. bolts, nuts, check nuts and spring washers etc. complete as required.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 35 sq.mm. but not exceeding 95 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required
Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm. but not exceeding 400 sq.mm. direct in ground including excavation, sand cushioning, protective covering refilling the trench etc as required.
Cable Route Marker:- Supplying and making cable route marker with cement concrete 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm x 60 cm at the bottom and 50 mm x 50 mm at the top with a thickness of 10 cm including inscription duly engraved as required.
Supply, Installation, testing and commissioning of following, size ceiling fan 3 Blades confirming to IS : 374 : 2019 including wiring the down rods of standard length (up to 30cm) with 1.5 sq.mm. FR PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as required. 1200mm (48") ceiling Fan
S.I.T.C. of following rating, surface mounted LED light fitting, suitable for 230V 50Hz, single phase supply etc. complete as required. 20/22W LED Tube Light
Power Transformer (with off load Tap Changer) Any ISI Mark
Supplying outdoor type copper wound transformer continuously rated for 3 Ph. 50 Hz at full load and temp rise not exceeding 450 C by thermometer in oil and 500 C by the resistance in winding after continous run at full load rating, the transformer should have oil immersed winding having vector group DY11, HT side connected in delta and LT side connected in star with neutral brought out connected to provide separate earthing. The Transformer shall have power terminal arrangement, bushing/cable end box on HT side and cable end box on LT side 2 no. chhanels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. The transformer should have following standard fittings. Transformer shall be latest manufacturing stndards as per amended IS specification and the load & No load losses shall be limited to the values given below r s per IS : 2026 or Norms issued by SEB which ever are lower -
1. Oil Conservator with fitting hole with cap and plain oil level gauge
2. Silica gel dehydrating breather charged with silica gel
3. Oil drain valve
4. Oil filter valve
5. Lifting eyes/hooks
6. Two earthing terminals
7. Diagram and rating plate
8. Air vent
9. Explosion vent
10. 100mm dia thermo meter with thermometer pocket
11. Four bi directionsl plain roller.
200 KVA (No load loss 500W and load loss 3000W)
S/D of 1100 volt grade Aluminum armoured cable, multi core PVC insulated, PVC extruded inner sheath armoured cable.
50 Sq.mm, 3.5 core
70 Sq.mm, 3.5 core
95 Sq.mm, 3.5 core
3.5c x120 sq mm
Supplying HT Aluminium three core cable XLPE insulated insulating screened with extruded semi conducting compound in combination with copper tape (0.3 KA for 1 sec.) cores laidup inner sheath of pvc tape,galvanised steel flat strip armourd and overall PVC sheathed cable conforming to IS:7098/II/85 with latest amendments. 3c x 240 sqmm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC innsulated aluminum conductor cable of 1.1 KV grade as required
3½ X 50 sq. mm (35mm)
3½ X 70 sq. mm (38mm
3½ X 95 sq. mm (45mm)
3.5c x120 sq mm (45mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC innsulated aluminum conductor cable of 11 KV grade as required. 3c x240 sq mm
Providing , laying and fixing following dia GI pipe (medium Class) in ground complete with G.I.Fittings including trenching (75 cm deep) and refilling etc. as required. 50 mm dia
12" (300mm) metal exhaust fan
LED Street light (45/48W)
LED Street light (90/100W)
9/10 Watt LED Bulb
Bulk head fitting with 9/10 watt CFL/LED
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to125.00 M
(c) From126.0 M to150.00 M
DT : Basic rates for 125/115mm dia drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH rig Machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of E/I.. (Basic Rates) Drilling upto 30 mtr. Depth below G.L. in Rural Area
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 100 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for allleads & lifts, all complete as per direction of Engineer-in-charge
Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying Submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. the pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible Pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages - 2 HP
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 50 mm nominal outer dia Pipes
Supplying and stacking of good earth at site including royalty and cariage up to 1 km. (Earth measured in stacks will be reduced 8% for payment)
Supplying and stacking of sluge at site including royalty and cariage up to 1 km. (Earth measured in stacks will be reduced 8% for payment)
Supplying and stacking at site dump manure from local or other approved source including royalty and cariage up to 1 km. (Manure measured in stacks will be reduced 8% for payment). Screened through sieve of I.S. designation 4.75 mm.
Rough dressing the trenched ground including breaking clods.
Fine dressing the ground
Spreading of sludge, dump manureor / and good earth in required thivkness(Cost of sludge, dump manure or / and earth to be paid seperately).
Mixing earth and sludge or manure in proportion specified or directed.
Providing and displaying of Araucaria cookie plant, having ht. 60 cm to 75 cm, straight, well developed, fresh and healthy with lush green leaves from bottom to top in 20 cm size of Earthen pot / Plastic pot. & as per direction of the officer-in-charge.
Providing and displaying of Brassia Variegated plant, having ht. 30 cm to 45 cm, well developed with fresh and healthy foliage in 25 cm size of Earthen pot / Plastic pot . & as per direction of the officer-in-charge.
Supply and stacking of Cassia fistula (Amaltash) plant of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Supply and stacking of Azadirachta indica ( Neem ) plant of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge.
Supply and stacking of Cassia javanica plant of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Supply and stacking of Adansonia digitata (kalp vricksh) plantof ht 150-165 cm in bag size of 25 cm as per direction of the officer-in charge.
Supply and stacking of Magnolia grandiflora plant of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.
Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge
Planting Permanent Hedges including Digging of Trenches (Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30 cm apart)
Maintenance of Hedge for one year
Planting Flowering Plants and Shrubs in Central Verge
Maintenance of Flowering Plants and Shrubs in Central Verge for one Year
NON-SCHEDULE ITEMS
Supplying, installation, testing and commissioning of Outdoor Feeder Pillar with 16 swg MS sheet with one coat steel primer and two coat spray painting with approved shade,making PCC Plinth and foundation including fitting and fixing,connection,transportion up to work site,labour charge etc all complete as reqd.
INCOMER:- 4 pole MCCB 200A,35 KA with fixed thermal magnetic setting.(1 Nos.) 1 Set phase indication lights (R, Y, B) 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. 1 No. 0-200 Amp. Ammeter (digital type) with inbuilt ASS AL. BUSBAR CHAMBER:- 200 amp 415 V heavy duty three phase with neutral bus bar chamber. OUT GOINGS:- 4 pole MCCB 100 A,10 kA with fixed thermal magnetic setting.(3 Nos.) 6/32 A, DP, MCB.(2 Nos.) TOTAL COST OF OUTDOOR FEEDER PILLAR NO-1.
Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes ,royalty etc all complete job as per direction of E/I.
Add 12 % GST
Add 1% Labour Cess
M/S SETH KUMAR
SHANKAR AND COMPANY
M/s Raj Construction
CHHOTELAL CONSTRUCTION PRIVATE LIMITED
Ms R. S. Construction
M/S PUJA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid