ROHIT KUMAR
Punhana PHED
Special repair for renovation and upgradation of existing 4.5 MLD STP bassed on MBBR Technology.
2025_HRY_444955_1
2025629DCFF8 0D7F 41F0 8B0C 80FEB58C8F71562PUH
Open Tender
Civil Works
Works
180 days
Punhana
2 documents required · 2 mandatory
₹5,000
₹2.0 L
Yes
3 Jul 2025
5 May 2025
14 May 2025
5 May 2025
13 May 2025
5 May 2025
Amount
Job work for Data transfer of BOD, COD, TSS, PH inlet flow meter, outlet Flow meter at portal of HSPCB and CPCB including cloud charges and sim Charges complete in all respect.
P/ Fof Grouting steel flate plates 12mm thick and 200mm vide for running of secondary clarifier bridge wheels on it and replacement of V Notch wier with SS V Notch and fired with proper level around the collecting drain complete in all respect.
P/F of flat rectangular type LED street light mounting of steel pole 75 watt complete with wiring etc.
P/F of Stainless steel mechenical fine screen having 6mm spacing with 8 mm thick stricks angle 60 degree with horizontal bed at grit chamber at STP. ` In Course`
P/F of Stainless steel mechenical fine screen having 6mm spacing with 8 mm thick stricks angle 60 degree with horizontal bed at grit chamber at STP. ` In Fine `
Repair of Gate valves at MBS including replacement of damage GI pipe with 50mm SS pipe and all other works contingent thereto.
Supply Installation , commission and testing of 1 No. electromagnetic flow meter along with RTU inlet pipe of 4.5 MLD STP and all other works contingent thereto.size 250 mm
Supply Installation , commission and testing of 1 No. electromagnetic flow meter along with RTU outlet pipe of 4.5 MLD STP and all other works contingent thereto. of size 250 mm
Supply Installation , commission and testing of 1 No. Junction box for non clog motor at 4.5 MLD STP and all other works contingent thereto.
Supply Installation , commission and testing of 1 No. VFD at 4.5 MLD STP and all other works contingent thereto. for 30 HP Flow meter
Supply Installation , commission and testing of 2 No. DO meter at 4.5 MLD STP Punhana and all other works contingent thereto.
Cleaning and disposal of Sludge beds i.e 8 No. SDW are filled fro dry sludge complete in all respect
Job work for repair and service of 3 No. Blower Units repair of blower motor repair of blower , capacity assessment , foundation of Blower Unit and repair of covering Unit including paint replacement of damaged insulation material repair of air release / Control valves and repair of connecting air line from blower to difuses complete in all respect.
P/F of 12 watt Battery for generator and DG set at STP
P/F of 5 Mega Pixel high video regulation with night vision quillity with audio support at STP Punhana complete in all respect.
P/F of All kind of Chemicals and equipments for STP lab at STP Punhana complete in all respect
PF of 12 Watt tubeler Li-Im Battery for inverter
Providing and fixing of 1 KVA UPS for Computer STP Punhana
Providing and fixing of New inverter for double battery make Luminous1500VA at STP Punhana
Providing and fixing of Roto pumps and motors with fully automatic electric panels for disposal of sludge to drying beds including all fiixing accessories complete in all respect.
Providing and fixing of SS Scrappers for bridge in secondary clarifier and complete repair of bridge including painting and all other works contingent thereto.
Repair and erection of Fully automatice electric panel board for 5 No. Sewage Pumps , 3 No. Blowers 1 No. Bridge Motor 2 No. Sludge thickner motor complete in all respect including providing or repair of insulation of panel steps , Providing and fixing of all asences like CCWLD, UBTD, Level low, Level High replacement of erusting demaged wiring contractor main switchs relays MCB preventors indicators voltmeters ammeters coplete in all respect of reputed make like l andT etc.
Repair of 5 No. guid pipes including replacement of damaged pipes connecting 150x100x12 ISB MB and chekerd plates 15mm thick of operating platesforms complete in all respect.
RAJEEV KUMAR GOEL CONTRACTORS (BID ID -1260057)
RAJEEV KUMAR GOEL CONTRACTORS (BID ID -1260057)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .