Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-AOC KALYANESWARI PASCHIM BARDHAMAN WEST BENGAL | KALYANESWARI | PASCHIM BARDHAMAN | WEST BENGAL | L1 | Accepted-AOC Stands L1 and Satisfactory | |
| 2 | L2₹1.2 L+₹1,168.05 (1.00%)Rejected-Finance 223 N DHARMAPALLY TENTULTALA ASANSOL BURDWAN WEST BENGAL 713304 | ASANSOL | BURDWAN | WEST BENGAL | 713304 | L2 | Rejected-Finance Stands L2 | |
| 3 | L3₹1.2 L+₹2,335.73 (2.00%)Rejected-Finance | L3 | Rejected-Finance Stands L3 |
Tender Value
Refer Docs
EMD Value
₹4,000
Closing Date
20 Feb 2023, 3:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Asn Mech Divn, PHE Dte
Janasasthya Karigori Bhaban, Sen-Releigh Road, Opp ESI Hospital, Asansol - 05
Renovation of Internal wiring and other allied works at Kalyaneswari AE I Quarter under RCFA Part I Water Supply Scheme.
2023_PHED_467028_5
WBPHE /EE/AMD/NIT 56e / 2022-2023
Open Tender
Electrical Work/ Equipment
Item Wise
15 days
Kalyaneswari
Please refer Tender documents.
3 documents required · 3 mandatory
₹4,000
10 Apr 2023
6 Feb 2023
22 Feb 2023
6 Feb 2023
20 Feb 2023
6 Feb 2023
Amount
Dismantliong of old damaged wiring from high level ceiling (3.7 mtrs) building of AE -I Quarter Building all complete as per direction.
Supplying and fixing 8 way double door Horizontal TPN MCB Distribution board ( DHDNTHCDRW08 ) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Make : Havells /Equivalent .
Laying of one No. cable 10 sqmm x 4 core sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed ( Cable supply by departmentally ).
Laying of cable 10 sqmm x 4 core on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting .( Cable supply by departmentally )
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE armoured cables as below : ( a ) 10 sq.mm x 4 core cable.
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials ( a ) 4 core 10 sqmm cable
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection .
(a ) 10 Amp.SP MCB .Make : Havells/ Equivalent.
(b ) 16 Amp.SP MCB .Make : Havells/ Equivalent.
Supplying and fixing 63 Amp. 4 pole 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Cutting channel of 43 mm x 43 mm size on masonry wall incl.S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
( a ) 25 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
( a ) 2x2.5 sqmm + 1 x1.5 sqmm as ECC
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish
( I ) 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
( a ) Average run 7 mtr
( b ) On Board 5 pin 5A Plug point
Excavation of soil for installation of Earth Electrode and filling & ramming
( a ) For Morrum Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below ( a ) By TATA-Medium GI pipe
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. (a ) No. 8 SWG
1200 mm sweep size ceiling fan , 220 - 240 V , Single phase , 50 Hz , Model : Arctic Air . Make : Orient .
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set.
Add. GST@18%
Add. Cess@1%
BENGAL CONSTRUCTION
INDUSTRIAL ELECTRICAL CORPORATION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .