Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC | L1 | Accepted-AOC Being lowest L1 | |
| 2 | L2₹44.8 L+₹49,500 (1.12%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹45.8 L+₹1.5 L (3.40%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹46.6 L+₹2.4 L (5.32%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹46.8 L+₹2.5 L (5.67%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Mar 2024, 6:00 pmClosed
GE (AF) Pathankot
GE (AF) Pathankot
REPAIR/ MAINT OF AMF PANELS, DG SET AND CONNECTED ITEMS AT AIR FORCE STATION PATHANKOT
2024_MES_644107_1
8422/GE/PAF-65/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Pathankot
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Pathankot
₹90,000
Yes
7 Jun 2024
26 Feb 2024
20 Mar 2024
26 Feb 2024
18 Mar 2024
11 Mar 2024
Amount
Servicing of Folllowing capacity of DG set installaed at varieouis locations by replacing fuel filter , Lub oil filter , by pass filter , air cleaner inner and outer element , water seperator , , engine oil, cleaning of diesel tank , cleaning of radiator as recommended by manufacturercomplete all as specified and directed by Engr-in-charge. Note :- Fuel filter , Lub oil filter , by pass filter , air filter will be replaced in the quoted rate of this item. (a) 400 KVA DG Set complete all as specified and directed by Engr-in-charge .
All as per ser item no 1.00 here-in-above but 320 KVA DG Set complete all as specified and directed by Engr-in-charge .
All as per ser item no 1.00 here-in-above but 200 KVA DG Set complete all as specified and directed by Engr-in-charge.
All as per ser item no 1.00 here-in-above but 160 KVA DG Set complete all as specified and directed by Engr-in-charge .
All as per ser item no 1.00 here-in-above but 125 KVA DG Set complete all as specified and directed by Engr-in-charge .
All as per ser item no 1.00 here-in-above but 100 KVA DG Set complete all as specified and directed by Engr-in-charge .
All as per ser item no 1.00 here-in-above but 82.5 KVA DG Set complete all as specified and directed by Engr-in-charge .
All as per ser item no 1.00 here-in-above but 60 to 75 KVA DG Set
All as per ser item no 1.00 here-in-above but 20 to 40 KVA DG Set complete all as specified and directed by Engr-in-charge .
All as per ser item no 1.00 here-in-above but 5 to 10 KVA DG Set complete all as specified and directed by Engr-in-charge .
Supply only Fan/V belt for the following capacity of DG Set including taking out unserviceable items complete all as specified and directed by Engr-in-charge . (a) 400 KVA DG Set complete all as specified and directed by Engr-in-charge .
All as per ser item no 11.00 here-in-above but 320 KVA DG Set complete all as specified and directed by Engr-in-charge .
All as per ser item no 11.00 here-in-above but 200 KVA DG Set complete all as specified and directed by Engr-in-charge .
All as per ser item no 11.00 here-in-above but 160 KVA DG Set complete all as specified and directed by Engr-in-charge .
All as per ser item no 11.00 here-in-above but 125 KVA DG Set complete all as specified and directed by Engr-in-charge .
All as per ser item no 11.00 here-in-above but 100 KVA DG Set complete all as specified and directed by Engr-in-charge .
All as per ser item no 11.00 here-in-above but 82.5 KVA DG Set complete all as specified and directed by Engr-in-charge .
All as per ser item no 11.00 here-in-above but 60 to 75 KVA DG Set complete all as specified and directed by Engr-in-charge .
All as per ser item no 11.00 here-in-above but 20 to 40 KVA DG Set complete all as specified and directed by Engr-in-charge .
All as per ser item no 11.00 here-in-above but 5 to 10 KVA DG Set complete all as specified and directed by Engr-in-charge .
Checking and repair wiring of control panel /AMF Panel including replace of defective wire and testing complete all as specified and directed by Engr-in-charge.
Supply and fixing MCCB 3 pole 415 volts with rupturing cap 16 KA , 100 Amps thermal magnetic complete all as specified and directed by Engr-in-charge.
Supply and fixing MCCB 3 pole 415 volts with rupturing cap 16 KA 63 Amps complete all as specified and directed by Engr-in-charge.
Supply and fixing MCCB 4 pole 415 volts with rupturing cap 160 Amps complete all as specified and directed by Engr-in-charge.
Supply and fixing MCCB 4 pole 415 volts with rupturing cap 200 Amps complete all as specified and directed by Engr-in-charge.
Supply and fixing MCCB 4 pole 415 volts with rupturing cap 250 Amps complete all as specified and directed by Engr-in-charge.
Supply & fixing multifunctional digital Astro Rex3 D-21 including connecting electrically using copper conductor cable of appropriate sizecomplete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement power contactor 4 pole 415 volts 50 Hz AC-3 duty, current rating 63 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement contactor 4 pole 415 volts 50 Hz AC-3 duty, current rating 100 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement contactor 4 pole 415 volts 50 Hz AC-3 duty, current rating 150 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement contactor 4 pole 415 volts 50 Hz AC-3 duty, current rating 250 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement air break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 70 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement air break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 110 amps (normal life) with operating coil voltage 230 volts , complete all as specified and directed by Engr-in-charge.
Supply and fix single single core cupper LT power cable of size 95 sqmm PVC innersheathed unarmoured complete all as specified and directed by Engr-in-charge.
Supply and fixing single single core cupper LT power cable of size 120 sqmm PVC innersheathed unarmoured complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of Over/under voltage Relay 3 phase 415 volts AC complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of Engine starting / stopping Relay 12 / 24 Volt DC complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of AC Timer 230 Volts having adjustment 0-60 Seconde. complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of DC Timer 12/24 Volts having adjustment 0-60 Seconde complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of Cranking Relay 12/24 V complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of DC Relay Multipin complete 12 V/24 V. complete all as specified and directed by Engr-in-charge.
Material and labour for AVR of DG Set 100 KVA to 400 KVA complete all as specified and directed by Engr-in-charge.
Material and labour AVR of DG Set 5 KVA to 82.5 KVA complete all as specified and directed by Engr-in-charge.
Material and labour Battery Charging alternator 12/24 volt with in built regulator of DG Set complete all as specified and directed by Engr-in-charge.
Material and labour Electromechanical governor of DG set 5 KVA to 160 KVA complete all as specified and directed by Engr-in-charge.
Repair of DG Set engine 5 to 82.5 KVA capacity opening /dismantling the complete engine and repair of crank shaft ,replacement of head gasket and other gaskot, bush, bearing any type, oil seal, rings or any lath work at Civil workshop, replacement of defected piston assembly, cylinder liner, head inlet/outlet valves and other gasket and reassemble after repair ,testing, commissioning complete in tht presence of Engg-in-Charge.
Repair of DG set engine 100 KVA to 320 KVA by opening / dismantling of engine Head of DG set complete major overhauling and repair replacement of Valve Guide, inlet/ outlet Valve, valve seals,head Gaskets, injectors assemblies, and repair head in Civils workshope and reassemble after repair ,testing, commissioning complete in tht presence of Engg-in-Charge.
Material and labour for Solonoid valve as per sample complete all as specified and directed by Engr-in-charge.
Material and labour for Flexible fuel pipe as per sample complete all as specified and directed by Engr-in-charge.
Material and labour for High pressure pipe as per sample complete all as specified and directed by Engr-in-charge.
Material and labour for radiator hose pipe as per sample complete all as specified and directed by Engr-in-charge.
Replacement of tripping coil 12/24 Volts as per sample complete all as specified and directed by Engr-in-charge.
Material and labour for coolant complete all as specified and directed by Engr-in-charge.
Material and labour for Distilled water for battery refilling complete all as specified and directed by Engr-in-charge.
Material and labour for water pump assembly as per sample complete all as specified and directed by Engr-in-charge.
Material and labour for head gasket kit for DG Set any cap as per sample complete all as specified and directed by Engr-in-charge.
Repair to battery charger upto 60 Volt including rewinding of transformer of charger, repair/ replacement of rectifier assy, switches, ammeter, voltmeter etc complete all as specified and directed by Engr-in-charge.
Repair to radiator assy Cleaning washing thoroughly, de- scaling and M&L for replacement of rubberize paid and MS Nut & Bolts including brazing /repair of cooling tubes with dismantling and segregation upper and lower chamber (tank) including and reassembling any type any capacity complete all as specified and directed by EIC.
Dismantling the alternator assembly of DG set of capacity 5 to 82.5 KVA from the foundation after disconnecting the electric connection,carrying the same to workshop,dismantling of alternator and taking down worn out windings of rotor field coils and excitor coils,rewinding the stator,rotor and excitor gauge,replacement of insulation material,heat varnishing provision of connecting leads and terminal plates etc to make the alternator fully serviceable,reassembling the alternator shifting back to the installation ,assembling the same with engine making electric connections,testing and commissioning complete all as specified and directed by Engineer-in-Charge.
All as per ser item no 59.00 above here in before but for DG Set of cap 100 KVA to 320 KVA complete all as specified and directed by Engr-in-charge.
Overhauling of PT (Pressure time) fuel pump by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts and testing by celebration as per sample of cap 5 KVA to 63 KVA complete all as specified and directed by Engr-in-charge.
All as per ser item no 61.00 above here in before but for DG Set of cap 100 KVA to 320 KVA complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of self starter 24 volt complete with accessory for DG set as per sample. complete all as specified and directed by Engr-in-charge.
Supply and fixing self starter 12 volt complete with accessory for DG set – as per sample. complete all as specified and directed by Engr-in-charge.
Repair to self starter 12/24 volts with replacement of carbon brushes,pinion,rewinding of starter and rotor winding ,replacement of defective bents etc to make the starter fully serviceable and testing for DG Set any make any size complete all as specified and directed by Engr-in-charge.
Repair to DG Set control panel any type incl replacement defective sensors like AMF module , relay card / board ,current transformer ,key switch , indiators , warning ,push button and checking wiring complete including made functional all the system/controls complete all as specified and directed by Engineer in charge
Supply and fixing of maintinance free battery 12 volt 180 AH tubular type including battery leads and initial charging of battery complete all as specified and directed by Engr-in-charge.
Supply and fixing of maintinance free battery 12 volt 100 AH tubular type including battery leads and initial charging of battery complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement on load change over switch of capacity 400 amps front operated four pole 415 volts 50 Hz of complete all as required for integrating electrically and connecting with existing panel all as directed by Engr in Charge.
Supply and fixing in replacement on load change over switch of capacity 320 amps front operated four pole 415 volts 50 Hz of complete all as required for integrating electrically and connecting with existing panel all as directed by Engr in Charge.
Supply and fixing in replacement on load change over switch of capacity 200 amps front operated four pole 415 volts 50 Hz of complete all as required for integrating electrically and connecting with existing panel all as directed by Engr in Charge.
Supply and fixing in replacement on load change over switch of capacity 100 amps front operated four pole 415 volts 50 Hz of complete all as required for integrating electrically and connecting with existing panel all as directed by Engr in Charge.
Material and labour for inbuilt auto battery charger fitted in DG set control panel /AMF panel operating 12 Volt 6 Amps to charge battery during main supply having mains , boost , float , battery reverse indicator with electric connection complete all as specified and directed by Engr-in-charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in any type of soil for laying of cable complete all as specified and directed by Engineer-in-charge.
Returning filling in (soil) including spreading levelling, watering and well ramming in layers not exc 25cm thick all as specified and directed by Engineer -in-charge.
Removal of excavated soil to a distance n.exc 50 m and depositing where directed at a level not exc 1.5 mtr above the ground level/starting point complete all as specified and directed by Engr-in-charge.
Sand cushioning to the under ground electric cable complete all as specified and directed by Engr-in-charge.
Material and labour Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and directed by Engr-in-charge.
Reuse old Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and directed by Engr-in-charge.
Relaying only LT cable taking out aganist items passing through pipe 1100 volts grade heavey duty cable with PVC insulated multistand aluminium conductor of size 6 to 185 Sqmm 2/3.5 core , armoured with galvanized steel strip or wire complete all as specified and directed by Engr-in-charge.
Supply laying and testing cable XLPE insulated screended PVC bedded , galvanised steel strip armoured, electric power cables (heavy cable ) with stranded aluminium conductor , 1100 Volts grade of size 3.5 core 120Sqmm complete all as specified and directed by Engr-in-charge.
Supply laying and testing cable XLPE insulated screended PVC bedded , galvanised steel strip armoured, electric power cables (heavy cable ) with stranded aluminium conductor , 1100 Volts grade of size 3.5 core 95 Sqmm complete all as specified and directed by Engr-in-charge.
Checking the DG set for its oil pressire ,leakage any type ,,pipe coolant, AMF panel entire servicivility, finding any type of fault in the engine along with cleaning the DG set and maintaing proper record of each DG set ,Register provided by contractor ,on daily basis equiped with tool kits,clamp meter ,pliers,testpain,,screw gause,all type of key set etc all as directed byEngineer-in-charge.Note-DG set mechanic must have full knowledge and experience of DG set controll panel and Engine.) complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement on delay timer 12/24 volt all as specified and directed by Engr-in- charge.
Supply and fixing in replacement on delay timer 230 volt all as specified and directed by Engr-in- charge.
Supply and fixing in replacement relay MG 73 AH all as specified and directed by Engr-in- charge.
Supply and fixing in replacement relay 8 PIN 12/24 volt all as specified and directed by Engr-in- charge.
Supply and fixing in replacement on glass relay timer 230 volt all as specified and directed by Engr-in- charge.
Supply and fixing in replacement phase sequence and phase sequence relay all as specified and directed by Engr-in- charge.
Cutting grasses, bushes, wild growth (after cutting remaining grass should not be more than 50 mm from ground level) to the entire satisfaction of Engr-in-Charge and including cleaning of area around the HT/ LT pole, LT Feeder Piller / LT Panel out door, E&M installation bldgs etc, removal of sharps, bushes and grasses and deposited as where directed by Engr-in-Charge. (ii) Any damage cause due to contractormen will be rectified without any extra payment
Material & Labour for earthing complete with copper earth plate elect rode 600x600x3mm thick buried directly in ground to a depth not less than 3 mtr deep below normal ground level with top edge of the earth plate not less than 2.25 mtr deep below normal ground level connected to copper strip 20x3mm size as earthing lead by means of soldering/brazing and bolts, nuts, check nuts and washers of brass, GI protection pipe light grade 40mm bore up to test point 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:2:4 type BI, RCC cover with suitable handle, earth pit filled with ground enhancing material i.e. mixture of copper sulphate, magnesia sulphate, graphite power etc mixed in equal quantity all around earth plate up to 150 cm and filled with vegetable soil above GEM up to ground level earth work in any type of soil all as required and directed including testing on completion. (i) Main earthing lead from earth plate electrode to test point upto length of 7.5 meters length shall deem to be included in the unit rate quoted against this item . (ii) GI protection pipe & earthing lead beyond 7.5 metre shall be measured and paid for seperately under appropriate item of Sch A part-IV (Sec-I) . (iii) On testing after completion if the desired resistenance is not obtained the contrator shall redo the earthing without any extra cost to the department . (iv) vegetable soil from outside to be provided by contractor included in quoted rate Note for item No. 30 to 32 for all type of earthing - (1). Contractor will be responsible for the functionality of earthing pit & its acceptable earth resistivity for 6 month from date of completion of CA. Note - (2) . Eath work & filling of material inside the earh will be carried out in presence of user rep.
Supply and fixing of maintinance free battery 12 volt 7AH tubular type including battery leads and initial charging of battery complete all as specified and directed by Engr-in-charge.
Repair to complete Electro monitoring system/Engine controll panel of all type DG set complete all as specified and directed by Engr-in-charge.
Supply Battery terminal all as specified and directed by Engr-in-charge.
Surya & Gautam Builders
M/S SHRI RAM BUILDERS
M/S V K TRADERS
Ashoka Engineers
SUBASH MAHAJAN
M/S SINGHAL ENGINEERS
INDERJIT SINGH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .