Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹21.3 L+₹79,101 (3.86%)Rejected-Finance | L2 | Rejected-Finance not lowest | |
| 3 | L3₹21.3 L+₹80,413.45 (3.92%)Rejected-Finance 21 GURUKRIPA PATIL LAYOUT GOPLA NAGAR NAGPUR 440022 | NAGPUR | NAGPUR | MAHARASHTRA | 440022 | L3 | Rejected-Finance not lowest | |
| 4 | L4₹22.1 L+₹1.6 L (7.88%)Rejected-Finance | L4 | Rejected-Finance not lowest | |
| 5 | L5₹22.1 L+₹1.6 L (8.04%)Rejected-Finance SIBAL NIWAS BAGADGANJ POST OFFICE NAGPUR 440008 | NAGPUR | NAGPUR | MAHARASHTRA | 440008 | L5 | Rejected-Finance not lowest |
Tender Value
Refer Docs
EMD Value
₹38,700
Closing Date
28 Apr 2021, 6:00 pmClosed
GE AF NAGPUR
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
PROVISION OF FOOTPATH AT SUDHA PARK AND SPECIAL REPAIR TO SIGNAL SECTION AT VSN NAGPUR
2021_MES_433726_1
GE/NAG/20-21/8439/81
Open Tender
Civil Works
Item Rate
180 days
GE AF NAGPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE AF NAGPUR
₹38,700
28 May 2021
31 Mar 2021
30 Apr 2021
31 Mar 2021
28 Apr 2021
14 Apr 2021
Amount
Taking down of shutters of any description not exceeding 1 sqm each all as specified and as directed.
Taking down of chowkat with shutter without taking off shutters from the frame, not exceeding 1.5sqm each all as specified and as directed.
S&F IInd class HW plain solid, straight ,chowkats and frame, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified and as directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, pillars etc all as specified and directed.
Demolition of cement concrete(unreinforced) of any description and in any position not otherwise specifically provided for all as specified and directed.
Dismantling boarding, any description, fixed in any position with screws all as specified and directed.
Dismantling framed timber scantlings 40 Sq. cm and over in section and in any position all as specified and directed.
Dismantling of framed fillets, rails, posts, rafters, purlins etc., under 40 Sq. Cm in section all as specified and directed.
M&L for dismantling of MS cooling duct in any shape/ size and to be deposited to MES store all as specified and directed.
S & F powder coated Anodised aluminium frame and shutter for doors, windows, ventilators with one or more rebates including necessary joining cleats, glazing clips, rubber packing, handles 2 Nos in each door, hinges, anodised alumnium snap beading, screws etc.(minium thickness of powder coating 50micron) complete all as specified
S & F 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty oin squares not exceeding 0.5 Sqm in each pane all as specified and directed.
S &F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed.
M & L 6 mm thick Veneered decorative Ply wood, grade 1 with BWR resin with decorative face veneers on both faces fixed with screws to timber frame work in stands, boards, partitions, shutters, etc. all as specified and directed.
M & L for providing and fixing Gypsum Board 12 mm thick in ceiling fixed with screws as peRmanufacturer's instructions all as specified and directed.
S&F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre and Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified
Taking down cement or cement lime plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. all as specified and directed.
M & L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished smooth and even without using extra cement all as specified and directed.
M&L for rendering 5 mm thick on fair faces of concrete surfaces in ceilings in cement mortar 1:3 and finished fair and even without using extra cement all as specified and directed.
M&L for preparing newly plastered surfaces of ceilings and applying three coats of white wash all as specified and directed.
M&L for white wash three coats on new plaster surfaces including prepration of surfaces complete all as specified.
M&L for preparing newly plastered surfaces and applying two coats of distemper oil emulsion including priming plastered and other surfaces with alkali resistant priming paint to distempering on surfaces of ceiling all as specified and directed.
M&L for preparing old painted surfaces by washing, rubbing down and stopping of distempered and painted surfaces and applying a coat of distemper oil emulsion on surfaces of walls all as specified and directed.
M&L for preparing old surfaces of ceilings by brooming down or by steel wire brushing and applying three coat of white wash all as specified and directed.
M&L for Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or girth on old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over one coat of pink primer all as specified and directed.
M & L for complete removal of old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or girth, on old painted steel surfaces of any description, over 10 cm width or girth, applying two coats of synthetic enamel paint over one coat of red oxide,zinc chrome not otherwise described including complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and directed.
S&F non skid ceramic white tiles 7to8 mm thick (square/ rectengular) area of each tiles exceed.06 sqm but not exc. .1 1sqm , white tiles in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match all as specified and directed.
S&F Joint free Glazed ceramic Coloured tiles 450x350x7 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match all as specified and directed.
S&F double charged Vitrified ceramic tiles 10 mm thick (square/ rectengular) size of each tiles shall be 600x600mm , in floors etc etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match in light shed all as specified and directed.
S&F double charged Vitrified ceramic tiles 10 mm thick (square/ rectengular) area of each tiles exceed0.36 sqm but not exc.0.42 sqm , in floors etc etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to matcch in light shed.in vertical surfaces all as specified and directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 for backing of Dado/ Skirting all as specified and directed.
M & L for Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:6 all as specified and directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 all as specified and directed.
M&L brick work with flyash bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 all as specified and directed.
S & F Mild steel work in window guard bars, plain, let in and fixed independently in wooden frames and similar work confiRming to Fe 290 Gde E-165 all as specified and directed.
M&L for Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified and directed.
M&L for two coat of wall care putty on wall all as specified and directed.
M&L for complete removal existing surfaces and applying two coats of distemper oil emulsion including chalk whitening preparatory to distempering on surfaces of ceilings all as specified and directed.
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil all as specified and directed.
Excavation in trenches n.exc 1.5 m wide & n.exc 1.5 m in depth for foundation etc on.exc 1.5 m in depth and getting out in Hard/dense soil as specified & as directed
M & L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils all as specified and directed.
Removing excavated soil n exc. 50 m and depositing where directed at a level n.exc. 1.5m above the starting point all as specified and directed.
M & L for hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface all as specified and directed.
M & L 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded granite stone aggregate) in sub base of flooring/ hard standing all as specified and directed.
Material and labour for 300x300x25 mm thick accupressure tiles sharp dotted type precast (factory made PCC tiles rubber moulded manufactured from OPC cement mixed with pigments strength minimum M-25 grade concrete vibro-compacting,confirming to IS 15658-2006 of any shape and design as approved laid over and including 20 mm screed bed in C:M 1: 6 laid required slope for avoiding water clogging , use compactor machine to ensure compaction. thereafter sprinkal sand over the fixed inter locking paver and pouring water evenly complete all as specified and directed. Note:- The shape and size of tiles shall be as approved by GE in writing before procurement. Sides of tiles shall be grouted in PCC 1:2:4, type B0 to make straight line. tiles shall be laidfrom one end keeping a gap of 1 to 2 mm between blocks and the gap shall be filled with sand as directed.
Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Hard/ Dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m & making good surface all as specified and directed.
M&L for Mild steel angles , bars , flats, etc as in supports for stiffening of fencing , wall ties, hold fasts, clamps plain angle cleats for securing purlins and similar small articles confirming to Fe 410-O or Fe 310-O all as specified and directed.
S & F Mild steel screw bolts (machine made) 16 to 20 mm dia of shank with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10cm but n exc 15cm long all as specified and directed.
Supply only Chain link MS Galvanized fencing, any size/type all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc., including provision of binding wire all as specified and directed.
M&L for Mild steel round bars 10 mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips in chain link fencing confirming to Fe-410-W(Gde.E-250)quality-A or Fe290 (Gde-E-165) all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement all as specified and directed.
S & F Mild steel work in framed and hung gates, including Pintle hinges, stops, hand made sliding bolts etc. and similar work confirming to Fe 290 Gde E-165 all as specified and directed.
Taking down DB/main switch of any size and making good disturbed surface of wall/floor complete all as specified.
Taking down carefully sub-main wiring of any description and making good to ther disturbed surfaces to match the existing all as specified and as directed by EIC.
M & L for sub main wiring (concealed) complete with four single core 6 Sqmm FR PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 6 Sqmm FR PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed.. Make of cable : Polycab, Finolex,Havells Note: 5 run of 6 sqmm&one run of PVC conduit shall be measured as single unit
M & L for sub main wiring (concealed) complete with two single core 6 Sqmm FR PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 6 Sqmm FR PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed.. Make of cable : Polycab, Finolex,Havells Note: 3 run of 6 sqmm&one run of PVC conduit shall be measured as single unit
M & L for sub main wiring (concealed) complete with two single core 4 Sqmm FR PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 4 Sqmm FR PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Make of cable : Polycab, Finolex,Havells Note: 3 run of 4 sqmm&one run of PVC conduit shall be measured as single unit
All as per serial item No 58 here-in-after but 20 mm dia rigid non-metallic PVC conduit heavy grade with two runs of 2.5 Sqmm and earth continiuty conductor of size 2.5 Sqmm all as specefied and directed. Make of cable : Polycab, Finolex,Havells Note : 3 run of 2.5 sqmm&one run of PVC conduit shall be measured as single unit
Taking down carefully any type point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified and as directed.
M & L for point wiring (concealed) on walls and surface on ceiling complete with FR PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit heavy grade accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls by cutting chases using machine and making good the disturbed surface, with and including suitable modular boxes ,switch plates of suitable make and 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed. (a) One light point controlled by one switch
(b) One fan point controlled by one switch
(c) One exhaust fan point controlled by one switch.
(d) One switch socket outlet modular type 3 pin 6 amp on same board.
(e) One light point controlled by two, two way switches,
All as per item No 61 above but 1.5 sq mm cable size and 1.5 sq mm earth continuity wire for one 3 pin socket outlet, 6 amps on Independent board.
All as per item No 61 above but 2.5 sq mm cable size with 2.5 sq mm earth continuity wire for one 3 pin socket outlet, 16 Amps on independent board. Note for Item No. 61 to 67 :- The disturbed surfaces of wall for concealing box/wiring shall be make good by applying cement plaster, putty and colour wash etc matching with the existing surfaces. The rate for point wiring shall be deemed to include the cost of making good.
S & F master led tube 4ft 20 W LED Tube . nominal system lumen output of 2100 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 40,000 burning hours at L70.The luminaire should have a color temperature of 6500K and CRI>83. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. The total power consumption should not exceed 18W (including driver). Make : Phillips/CG/WIPRO
S & F decorative box type fitting with blue coloured end caps pre wired for LED tube energy of 20 Watt . Make : Phillips/CG/WIPRO
S & F Surface mounting LED Luminaries and 1 x 9 Watt LED fitting with connecting up with copper 3 core flexible cord of minimum size 1.5 Sqmm size complete all as specified and as directed . Make : CG, Phillips, Wipro
S & F 0-4 step, one module, modular type electronic regulator for ceiling fan 1200 mm sweep, 240 volts, 100 Watts humfree single pole, all as specified and as directed. Make : Legrand Cat No. 675531
S & F switch modular type single pole two way 6 amps 250 volts, all as specified and as directed. Make : Legrand Cat No 675502
S & F Switch modular type, single pole one way 6 Amps, 250 volts Ac suitable for modular switch boxes without indicator, all as specified and as directed. Make : Legrand Cat No. 675501
S & F socket modular type single pole one way 6 Amps multistandard 250 volts all as specified and as directed. Make : Legrand Cat No. 675550
S & F for ceiling rose, surface bakelite, 65 x 50 mm, two to three terminals all as specified and as directed.Make : Leader, Anchor
S & F socket modular type 16 Amps, 3 pin combine, 2 module,240 volts all as specified and as directed. Make : Legrand Cat No. 675555, ABB,Seimens
S & F switch modular type 16 Amps,one way with indicator, 1 module,240 volts all as specified and as directed. Make : Legrand Cat No. 675513, ABB,Seimens
S & F power unit for upto 2 ton AC and geyser up to 3.5 KW modular type , 4 module,240 volts all as specified and as directed by EIC. Make : Legrand Cat No. 675558, ABB, Seimens
S & F sheet metal enclosures for DB's for incorporating MCBs, TPN, 4 way, IP-43 with metal double door with 200 amps rated busbar, 415 volts, as per IS-8623 including taking down the old unserviceable TPN DB, all as specified and as directed. Make : Legrand Cat No 507670, ABB, Seimens.
S & F MCB TPN, 63 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. Make : Legrand Cat No. 408683 , ABB , Seimens
S & F sheet metal enclosures for SPN DB's with metal double door for incorporating MCBs,IP-43 , 8 way with 200 amps rated busbar, 240 volts, as per IS-8623 all as specified and as directed. Make : Legrand Cat No 507611, ABB, Seimens
S & F MCB SPN, 32 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. Make : Legrand Cat No. 408617 , ABB, Seimens
S & F MCB SP 10-32 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. Make : Legrand, ABB,Seimens
M/s ABHIMAN HEGDE
Asha Enterprises
S D WAGHAMSHI
SIBAL AND SIBAL
Vishwakarma Engineering Works
Meet Road Lines
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .