Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.6 LAccepted-AOC 86 NAROTTAM KUNJ MADHU NAGAR AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹24.6 L+₹24,977 (1.03%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹26.4 L+₹2.0 L (8.30%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹29.4 L+₹5.0 L (20.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹30.3 L+₹5.9 L (24.4%)Rejected-Finance 40 6 UKHARA PO PRATAP PURA AGRA UP 282001 | AGRA | AGRA | UP | 282001 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
9 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (WEST) AGRA
62 Station Road Agra Cantt
ADDN ALTN TO BUILDING NO P 125 (JCOS LIVING IN ACCOMMODATION) OF HQ AFSOD AND IMPROVEMENT TO SECURITY INFRASTRUCTURE AT HQ AFSOD UNDER GE (WEST) AGRA
2020_MES_402642_1
8012/770/E8
Open Tender
Civil Works
Item Rate
180 days
GE (WEST) AGRA
As per NIT
9 documents required · 9 mandatory
₹500
GE (WEST) AGRA
₹56,000
Yes
19 Apr 2021
11 Dec 2020
12 Jan 2021
11 Dec 2020
9 Jan 2021
26 Dec 2020
60 days
Amount
Dismantling brick tiles in roof top laid bedded & pointed in any mortar and removing from site all as specified and directed.
Dismantling of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) all as specified and directed.
Disposal of removed / demolished soil / materials exc 1.50 km but n. exc 5 km and depositing where directed complete all as specified and directed
Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with CM 1:3 or PCC 1:2:4 type B0 complete all as specified and directed.
M&L cement concrete 1:2:4, type B-0, (Using 12.5 mm graded stone aggregate) in padding, roof kerbs or mud stops, rounded or chamfered on edges and similar work including necessary use & waste of formwork all as specified and directed.
M&L for 10mm thick rendering in CM 1:4 on brick or concrete surface finished fair & even complete all as specified and directed. Note: Plastering to be done when the concrete is green
M&L for making grooves of 300 x 300mm grid minimum 3mm depth complete all as specified and directed
M&L for cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in benching,coping, roof kerbs, mud stop etc and similar work including all necessary use & waste of form work complete all as specified & as directed.
M & L for water proofing treatment of roof slab all as followes: - (a) Preparation of roof surfaces by brushing, cleaning and M&L for applying 15mm thick plaster in CM 1:4 with water proofing compound @ manufacturers instruction. (b) Applying a priming coat with bitumen primer @ 0.5 ltr/Sqm (c) Applying a hot blown bitumen grade 85/25 @ 1.2 Kg/sqm (d) Laying APP modified water proofing membrane weighing not less than 3 Kg/Sqm will be laid over applied bitumen. (e) Applying a tack coat of hot bitumen grade 85/25 @ 1.2 Kg/Sqm and sand in confirming to Zone II in dry condition will be dusted over the bitumen @1.00 Kg/Sqm Note : WPC shall be measured and paid separately under respective item
M & L cutting holes into or through brick wall built in cement mortar superfacial area exc 150 Sqcm but n exc 400 sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
S & F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed.
S & F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S & F in repair 75 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S&F in 110 mm bore PVC (SWR) tee of any radius complete all as specified & directed.
S&F in repairs vitreous china wash down water closet pan pedestal pattern white (excluding flushing cistern and flush pipe) complete with seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hingeing device complete all as specified and directed.
S&F CP health faucet 15mm with 1.00m connection pipe of ABS body complete all as specified and as directed Make : Prayag Cat No 451 or equivalent
S&F bathroom cabinet mirror complete all as specified and as directed. Make Prayag Cat No 556 or equivqlent
S&F mild steel joist, channel, angle or tee sections fixed independently without connecting plates etc of grade fe-410-0 & fe 310-0 complete all as specified and directed.
S&F 5.0 cm thick sand stone slabs in sun shades, chajjas, shelves, roof slabs etc n.exc. 2m in length punched dressed on face and along exposed edges, self faced on other side and set and pointed in CM 1:4 complete all as specified and directed.
S&F in repairs three layered rotational moulded polyethene water storage tank 500 ltr capacity, hoisted and fixed in position including plug and check nuts, PVC cover complete all as specified and as directed.
S&F 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20 mm dia (minimum weight - 210 gm) complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connection complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connection complete all as specified and directed.
S&F 20mm bore steel water tubing medium grade galvanized including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed.
Refixing old steel water tubing 20 mm dia with and including new GI fittings and connected to new or old positions of walls, ceilings, floors etc complete all as specified and directed.
S&F 15mm bore steel water tubing, medium grade, galvanized including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed.
Refixing old steel water tubing 15mm dia with and including new GI fittings and connected to new or old positions of walls, ceilings, floors etc complete all as specified and directed.
S & F in repairs 15 mm bore chromium plated fancy bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth etc. brick walls complete all as specified and directed.
S&F in repairs 10 ltrs capacity PVC flushing cistern low level (white) with inlet ball valve and handle including brackets, rubber bush, washers etc complete all as specified and directed.
S&F in repairs Vitreous china wash basin white flat back size 550 x 400mm incl chain plug, brackets complete all as specified and directed. .
S&F 15mm bore, brass chromium plated pillar cock (foam flow) screwed down for pipe and fixed complete all as specified and directed.
S&F Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm- 45gms/40mm-60 gms) of 32mm bore suitable for wash hand basin complete all as specified and directed.
S&F corrugated waste pipe 32mm x 800mm Make Prayag Cat Part No - 327 or equivalent
S&F in repairs PVC connection 15mm size with PTMT nuts, 600 mm long complete all as specified and directed
S&F in repairs Stop valves, cast copper alloy screwed pressure, but fancy type, chromium plated with long shank and cup (concealed type) screwed both ends for iron pipe for unions and fixed
S & F in repairs Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) including fixing to steel pipe or union complete all as specified and directed
S&F in repair 15 mm bore CP angle/Stop valves, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed.
Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and pre-cast concrete articles complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed.
M&L for 15mm thick rendering in CM 1:6 on any faces of brick or concrete surfaces of walls & finishing the surface complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on brick or concrete surface with water proofing compound as per manufacturer's instruction finished fair complete all as specified and directed. Note : Water proofing compound will be measured and paid seperately under respective item of Sch ‘A’.
Supply only integral water proofing compound complete all as specified and directed.
M & L for rendering 10mm thick in CM 1:4 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered or un-plastered surfaces of walls and applying three coats of white wash on wall complete all as specified and directed.
M&L for preparation of new plastered or un-plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for preparation of new plastered or un-plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation of new plastered or un-plastered surfaces of wall and applying two coats of oil bound distemper over a coat of average 1mm thick Birla putty complete all as specified and directed.
M&L for preparation of old plastered surfaces of wall and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old plastered surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old painted surface of wall and applying one coat of cement base paint complete all as specified and directed.
M&L for complete removal of existing treatment of old plastered or unplastered surfaces of walls and applying two coat of distemper oil emulsion over a coat of 1mm thick wall care putty complete all as specified and directed.
M&L for preparation of old decorated plastered or un-plastered surface of wall and applying one coat of weather proof paint (APPEX Paint) complete all as specified and as directed
M&L for coloured glazed ceramic tiles in vertical surface 350 x 250 x 7 mm / 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match tiles including 10mm thick rendering in CM 1:4 on brick wall complete all as specified and as directed .
M&L glazed ceramic non skid joint free coloured tiles (1st quality/ premium quality) 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exc. 0.11 Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cment mortar (1:6) complete all as specified and directed.
M&L glazed ceramic non skid joint free coloured tiles (1st quality/premium quality) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11Sqm but not exc. 0.18 Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cment mortar (1:6) complete all as specified and directed.
S&F in repair 100 mm PTMT grating (Min weight 25 gms) complete all as specified & as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
Demolition of cement concrete (unreinforced) in any position n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L machine cut kota stone 20-25 mm thick as in floor, stair case, landing etc. laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing over 20mm thick screed bed in CM (1:6) as in floor complete all as specified and directed.
M&L machine cut kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick rendering as bed or bedding layer in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
PCC 1:3:6 C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection (75 mm thick) laying in alternate ways finished even and fair without using extra cement complete all as specified and directed.
S&F towel rail 600 mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 190 gms) complete all as specified and directed..
S&F in repairs mild steel PVC coated drapery rods, 25mm internal diameter including decorative type brackets and PVC curtain rings 8 Nos per RM including fixing arrangement with drilling holes in walls, brackets etc complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n. exc 1.5 Sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 Sqm but not exc 4 sqm each complete all as specified and directed.
Taking down shutter of any description exc 1 Sqm and not exc 2 Sqm each complete all as specified and directed.
S&F anodised (15 micron) aluminium door/window/vetilator frame and side/top hung or sliding shutter complete and fixed with fittings, one or more rebates including jointing cleat, glazing clips, rubber neoprene packing, aluminium snap beading, screws, anodised aluminium fittings etc. complete all as specified. Note: (i) Sheet glass and particle board, hinges, lock, handle, floor spring, hydraulic door closer will be measured and paid separatly (ii) Aluminium door frame with shutters shall be fixed in position in brick wall opening as required according to site conditions including all fastening arrangemennts etc complete all as specified and directed. (iii) The gap shall be sealed externally with Polysulphide sealant and finished flush with the surface
S&F 6.3mm Sheet glass, ordinary quality fixed to aluminium frame complete all as specified and as directed
Mild steel farmed work as in doors (as in ckowkats) or gates of angle or other section with guest plates rail, brasses rail etc exculsive of steel sheeting or other covering hanging also fastening and fixing complete confirming to Gde Fe-290 including shop coat of red oxide including prepration of surface before fixing complete all as specified and directed.
Refixing the shutters of any description exc 1.00 Sqm but not exc. 2 Sqm each in the same opening or in other opening complete all as specified and directed.
S&F Second class hard wood (SAL) chemically treated for ATT, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints including tarring back of chowkhat with a coat of crude oil complete all as specified and directed.
S&F 35 mm thick 2nd class hard wood (Hollock/Sal/Bijasal), locally febricated glazed skeleton door shutters open rebated and prepare to receive glass, gauge (without sash bars) edges of framing plain chamfered or rounded, fitted with cut including mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8, clause No 8.24 (a) complete all as specified and directed.
S&F 35 mm thick 2nd class plain framed panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commericial face veneers: supplied and fitted to chowkats, complete all as specified and directed.
S & F 25 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
M & L 19 mm thick particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work in cup board shutters, partitions, shelves and similar work complete all as specified and directed.
S&F 150 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F 100 mm long medium weight, cold rolled mild steel butt hinges complete all as specified and directed.
S&F 100 mm long aluminium anodised hinges complete all as specified and directed.
S&F solid PVC frame of size 50x47mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube supplying & fixing in opening as specified in clause No. 8B.3 at Sl page No. 145 and shown in drawing on sl page No 160 of SSR 2010 respectively and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified in clause No. 8B.2 at Sl page No. 143 to 144 and shown in drawing on sl page No 156 of SSR 2010 respectively and as directed.Make : Rajshree/Sintex
S&F 100 mm long stainless steel hinges type B-12 complete all as specified and directed.
S&F 150 mm long aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 100mm long aluminium anodised hasp and staple, safety type including bolt to hinge plate and fixed with screws complete all as specified and directed.
S & F mild steel angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps, plain angle cleats for securing purlins and similar small articles confirming to Fe 290 complete all as specified and directed.
S&F floor door stopper 150 mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor
S & F steel windows with side hung shutters including box type hinge with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S & F steel windows with side hung shutters including projecting type hinge with steel handle and steel peg stay, complete with out glazing bars, dovetailed or welded complete all as specified and directed.
S & F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and directed.
S & F Mild steel work in framed work such as grills, gratings, guard bars etc, with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe 410 - O or Fe 310 - O complete all as specified & directed.
S & F Galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed
S&F 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq. M in each pane complete all as specified and directed.
S&F 3 mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sq. M in each pane complete all as specified and directed.
S&F repair Aluminium anodized 150mm long barrel tower bolt of extruded section and fixed.
S&F in repairs 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F in repairs150 mm long aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F galvanised MS wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tack or galvanised wire staples as in repairs.
M & L for preparation of old wooden surface of any discription not otherwise discribed over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as specified and directed.
M & L for preparation of new steel surface over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old painted steel and iron surfaces of any description not other wise described over 10 CM width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Dismantling of AC sheets corrugated or semi- corrugated as in roof covering, wall clading including ridges complete all as specified and directed.
Dismantling un-framed timber scantlings 40 Sq. cm and over in section and in any position complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & as directed.
Demoltion of wall, ceiling board (fibre pulp, insulation etc) or insulation board/ slabs/blankets, any thickness, including cover fillets all as specified and directed
M&L anodised aluminium snap grid frame work for false ceiling complete all as specified & directed.
M&L hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified
M&L 6mm exposed metal frame ceiling with calcium silicate board if siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 x 600mm grid complete all as specified & as directed.(Frame work for ceiling shall be measured and paid separately)
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground for fixing of new posts complete all as specified & as directed.
Dismantling old barbed wires from posts or struts (wood, RCC or steel) complete all as specified and directed
Excavation in post holes (or similar holes) in soft soil each not exceeding 0.5 Cum getting out, returing filling in and ramming earth or broken rubble mixed with rearth around , in layers not excceding 25 Cm complete all as specified and as directed.
Removal of surplus soil not exceeding 50 mtr from staring point and depositing where directed as directed by Engr-in-Charge.
M&L PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) in foundation, filling and mass concrete complete all as specified & as directed.
S & F Mild steel work confirming to Fe 290 Gde E-165 as in fencing posts including cutting tops to shape as directed & struts, fillets for securing chain link fencing etc. including all necessary drilling, bolting or riveting, etc and similar work complete all as specified and directed
S&F mild steel screw bolts (machine made) with hexagonal or square head and one end screwed or screwed both ends, each screwed ends to be fitted with washers and one hexagonal or square nut, n exc. 5 cm long & diameter of neck 5 to 10mm complete all as specified and directed .
Supply only MS Galvanized chain link fencing any size and type complete all as specified and directed
Fixing only chain link fencing including line wires, any mesh, size and type of standards, rails, straining bolts etc. including provision of binding wire complete all as specified and directed
Supply only mild steel round bars confirming to Fe 290 Gde E-165 10mm dia as line rows for securing chain link fencing complete all as specified and directed Note: Cost of cutting to length, bent to shape required & binding with MS wire is included in the above rate
M&L preparation of new steel surfaces of any description, n exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed .
M&L for brick work (Except bricks) with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed.
M&L 100mm thick PCC 1:4:8 type D-2 (Using 40 mm graded stone aggregate) as in hardstanding, pavement complete all as specified.
M&L for cement concrete 1:2:4 Type B-1 (using 20mm graded stone aggregate) 40mm thick as in hardstanding, pavement complete all as specified & as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, lamp holders, light fitting etc removing materials to store for keeping in safe custody for taking credit or reuse serviceable fittings/fixtures and making good the disturbed surfaces of wall/floors complete all as specified & as directed.
M&L for point wiring in concealed conduit with 1.5 Sqmm PVC insulated flame retardent low smoke(FRLS) single core stranded copper conductor for one light/fan/bell point in and including PVC conduit 19/20 mm dia to be terminated in pressed steel terminal boxes with 3 mm thick bakelite sheet top cover including 1.5 sqmm PVC insulated "Flame Retardent Low Smoke"( FRLS)" single core stranded copper earth continuity conductor controlled by one switch and/or one regulator complete all as specified and directed. (Wiring shall be made as per colour code in IS for Phase, neutral and earth)
One socket outlet 5/6 Amps on independent bd controlled by one switch.
One socket outlet 5/6 Amps controlled by one switch on same board with other switches
All as per item No 127 here in before but one socket out let 15/16 Amps controlled by one switch on independent board and wiring with 2.5sqmm cable complete all as specified & as directed.
S&F switch piano flush type single pole , 5/6 Amps one way, 230 volts, complete all as specified & as directed.
Supply and fixing switch bell push button single pole , 5/6 Amps , one way , 230Volts complete all as specified & as directed.
S&F switch piano flush type single pole , 15/16 Amps one way, 230 volts, complete all as specified & as directed.
S& F socket outlet 5/6 Amps flush type piano 5 pin 230 volts complete all as specified & as directed.
S&F socket outlet 15/16 Amps multipurpose 3 pin 230 V complete all as specified & as directed.
S&F ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified & as directed.
Supply & Fixing lamp holder , insulated body ,with back plate suitable for batten fitting complete all as specified and directed.
Supply and fixing electronic steping up type ceiling fan regulator suitable to operate at 230 volts 50 Hz, AC supply complete all as specified & as directed.
S&F in replacement sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin and earth plug and socket complete with one No MCB, SP, 20 Amps, 230 Volts, 10KA 'C' series complete all as specified and directed.
Supply & fix in replacement surface/wall mounting LED batten 20 watt luminaire having Aluminium housing and integrated electronic driver with mounting accessories complete with lamp holders fixed to wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No-LUMILINEPLUSBS20WLED865SPCSS or equivalent Model of Philips/Bajaj/CG as approved by GE.
Supply & fix in replacement, outdoor street light LED 36/40 watt luminaire IP 65/66 protection polyster powder coated with pressure die cast aluminium housing and robust construction with reflector cover pre anodised and flat white high transmission acrylic cover or toughened glass, natural white type with electronic driver, connector block etc with internally prewired fixed to building with and including 1.20M long bracket made out of 40mm dia light grade GI pipe bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/MS clamps & 12mm dia bolts, nuts & washers etc and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- ENDURAPEARLNEOSL40WLED757PASYTOPC, Phillips cat part no BRP052 LED 036 CW HP SLA FG S1 PSU GR or equivalent as approved by GE.
Supply and fixing in replacement of electrical bell (Ding dong type) AC, 230 Volt complete all as specified & as directed.
Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor complete all as specified & as directed.
M&L sub main wiring of two single core PVC insulated unsheathed stranded copper conductor cables of size 6 Sqmm, 1100 volts grade drawn through and including 20mm dia PVC concealed conduit of 1.2 mm wall thickness including all fixing accessories, and 2.5sqmm PVC insulated stranded copper conductor cable as earth wire(green colour) connected to earth dolly complete all as specified and directed. (Phase-Red, Neutral – black in colour of cable) Note:- Both running cables including earth wire shall be measured & paid for as single length.
M&L for provision of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 2.5 sqmm drawn in and including PVC rigid conduit medium grade not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 1.5 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:- (i) Finished sub main wiring with two runs of 2.5 sqmm cable & one run of 1.5 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Taking down distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces.
S&F in replacement of unserviceable MCB DB sheet metal enclosure triple pole and neutral 415 V with 200 Amps standard bus bar of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mounting type double door factory fabricate complete without MCB and with encosure blank plates for unused way suitable for 4 way flush in wall complete all as specified & as directed.
All as per item No 23 above but DB SPN 8 way double door
S & F MCB, 63 Amps, TPN, 415 volts,10 KA rupturing capacity 'C, series as in repairs, complete all as specified and directed.
S & F MCB 40 Amps SP, 240 Volt C, series complete all as specified and directed.
S & F MCB SPN 40 Amps 240 Volts C, series complete all as specified and directed
S & F MCB 6 to 20 Amps SP, 240 Volt C, series complete all as specified and directed.
M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanised steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 .
Supply, assembling & hanging of fans ceiling complete with accessoriessuch as down rod up to 1.0 mtr long, electronic stapped type 100 watt ,socket type fan regulator etc suitable for operation on single phase AC elect supply ,230 V, 50 HZ of size 1200 mm sweep. BEE 5 star rated including three core flexible copper conductor cable of size 0.75 sqmm as required at site from ceiling rose to fan connector block all as specified by Engr-in-Charge.
Supply & fix LED Flood light of die cast aluminium body 50 W with high power LEDs as light source complete with electronic driver and lamp holders fixed to recess/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Havells cat part JETAQUANTOPLUSFLP60WLED757SYMLENS
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver including three core flexible copper conductor cable of size 0.75 sqmm as required at site from ceiling rose to fan connector block complete all as specified & as directed.
Supply and fix XLPE insulated armoured heavy duty multistranded electric cable with aluminium LT conductor 1100 volts grade ISI marked laid in trenches, fixed to wall poles etc of size 25 sqmm 3.5 core complete all as specified & as directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose/ soil for taking out/laying cable etc and getting out soft/loose soil complete all as specified & as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified & as directed.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified & as directed.
M&L sub-class 'B' bricks, well burnt, laid breadth wise along the length for cable laid in trenches over sand cushion laid for UG Cable protection, complete all as specified and as directed.
M&L for sand cushioning dry fine for cable cushioning 8 cm below the cable and 15 CM above cable complete all as specified & as directed.
Material and labour for galvanised steel tubing light grade for protection of cable/earth continuity conductor fixed to poles/walls/roof or laid in floors, road crossing/in ducts fixed with clamps, bolts, nuts and washers etc complete all as specified and directed for 50 mm dia bore pipe complete all as specified & as directed.
Supply and fixing steel tubular swaged pole 8.5 Mtrs long type 410 SP- 22 ISI marked final taper plug, bolts, nuts & screws including painting of pole with two pole of Aluminium paint over a coat of red oxide primer including 30 cm alternate step of black and yellow paint up to height of 1.5 Mtrs from top of PCC coping complete with base plate of MS sheet 30 cm x 30 cm x 6 mm thick welded at the bottom of pole complete all as specified & as directed.
Supply & fix outdoor street light LED 90 watt luminaire IP 65/66 protection polyster powder coated with pressure die cast aluminium housing and robust construction with reflector cover pre anodised and flat white high transmission acrylic cover or toughened glass, natural white type with electronic driver, connector block etc with internally prewired fixed to building with and including 1.20M long bracket made out of 40mm dia light grade GI pipe bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/MS clamps & 12mm dia bolts, nuts & washers etc and connecting up with & including twin twisted copper flexible wire from ceiling rose/junction box to fittings complete all as specified & directed. Make:- Havells cat part No- ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO, equivalent as approved by GE.
Supply, installation, testing and commissioning of astronomical time watch (Three phase) pannel with all accessories incl bypass arrangement, fixation wire 10 Sqmm multi stranded copper cable of finolex/Havells with following main item :- (a) Astronomical timer switch digital type all as per legrand D-21 type, cat No 412631. (b) MCB SP, 20A of Legrand - 3 No (c) TP contactor ML4 of BCH - 1 No (d) MCB FP, 63A of Legrand - 1 No (e) Anodised copper bus bar 4 strip mounted on insulator and of min length 30 cm for each strip (f) Auxiliary changeover switch 6A, 250V, Legrand model No 007350-1 No (g) clamp of 25 x5mm complete with nut, bolt and washers
Supply & fix outdoor street light LED 36/40 watt luminaire IP 65/66 protection polyster powder coated with pressure die cast aluminium housing and robust construction with reflector cover pre anodised and flat white high transmission acrylic cover or toughened glass, natural white type with electronic driver, connector block etc with internally prewired fixed to building with and including 1.20M long bracket made out of 40mm dia light grade GI pipe bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/MS clamps & 12mm dia bolts, nuts & washers etc and connecting up with & including twin twisted copper flexible wire from ceiling rose/junction box to fittings complete all as specified & directed. Make:- Havells cat part No- ENDURAPEARLNEOSL40WLED757PASYTOPC,Phillips cat part no BRP052 LED 036 CW HP SLA FG S1 PSU GR or equivalent as approved by GE.
Supply & fix NEW GENERATION POST TOP energy saving envirmental friendly long life 35 watt LED luminaire light fitting, IP 65 protection with reflector cover electronic driver, connector block etc with internally prewired fixed to brcket on gate with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No-RUBYPT35WLED757PSYMTOPC or equivalent model of make Philips/Bajaj/ Crompton Greaves as approved by GE.
Supply and lay in trenches or passing through pipe/fixed to wall/pole and duct cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volt grade ISI marked confirming to IS 7098 Pt-I with stranded aluminium conductor of size 10 Sq mm 2 Core all as specified and directed.
Supply and lay in trenches or passing through pipe/fixed to wall/pole and duct cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volt grade ISI marked confirming to IS 7098 part-I with stranded aluminium conductor of size 16 Sq mm 4 Core all as specified and directed.
Supply and fixing enclosed MS junction box of Size 300 mmx 250 mmx150 mm depth,Made out of 2 mm thick sheets with openable hinged shutter on front side with locking arrangement.The box shall be provided with and including 63 amps 3 nos and 32 amps one no Aluminium bus bar of size 200 x 3 mm mounted on porcelene insulators and MCB SPN 16 A -01 Nos and connecting the bus bars to cables with using suitable GI nut, Bolts and washers and aluminium lugs etc fixed on GI pipe using clamp nut, bolt and washers complete all as specified and directed. - Notes-(i) The Exposed and internal surfaces of the MS boxes and clamps shall be painted with applying two coat of aluminium paint over a coat of red oxide primer. (ii)The contractors quoted rates for above items are deemed to include for fixing the MS box in position with suitable MS Clamps and/or necessary PCC as per requirement.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps mounted on wall/pole/panel including all accessories complete all as specified and directed.
Material and labour for plain cement concrete (1:4:8) type B-2 using 40 mm graded stone aggregate for bed of poles complete all as specified & as directed.
Material and labour cement concrete (1:2:4), type C -1 (using 20 mm graded stone aggregate) for pedestal of poles/copping including necessary use & waste of form work fair finishing to exposed surfaces using extra cement complete all as specified & as directed.
Apoorva Constrution
M/s Rahul Kumar Agrawal
M/s Tomar Builders
Attar Singh and Sons
M/S SHRINATH CONTRACTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .