Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC NA | NA | NA | 121004 | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.7 L+₹40,877 (1.83%)Rejected-Finance G 86 DATA RAM SECTOR 18 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹24.0 L+₹1.7 L (7.52%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹24.7 L+₹2.4 L (10.8%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹32.3 L+₹10.0 L (44.6%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹44.2 L
EMD Value
₹88,320
Closing Date
10 Jul 2024, 6:00 pmClosed
GE NORTH DELHI CANTT 10
GE NORTH DELHI CANTT 10
REPAIR/MAINT OF STREET SECURITY LIGHTING SYSTEM REPLACEMENT OF UNSV LT PANEL BOARD AND MAINT OF EARTHINGS WITH CONNECTED EM WORK AND REPAIR MAINT OF UNSV INTERNAL ELECTRIFICATION WORK AND REPLACEMENT OF OLD UNSV SUB MAN WIRING DBS VARIOUS TYPES OF LE
2024_MES_660572_1
GE/NORTH-36/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE NORTH DELHI CANTT 10
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE NORTH DELHI CANTT 10
₹88,320
Yes
5 Sept 2024
19 Jun 2024
12 Jul 2024
19 Jun 2024
10 Jul 2024
4 Jul 2024
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5m depth for laying under ground cable/pipes in loose/soft soil all as specified and directed.
All as per the description of srl item No 1 above but Hard/dense soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removal of surplus soil obtained from excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
M&L for sand cushioning for protection of cables with screen wash river sand and punning to proper required cover all as specified and directed.
M&L for bricks of sub class ‘B’ bricks, for cable protection in trenches laid dry and flat all as specified and directed.
Supply, laying, jointing, testing and commissioning in replacment LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors 10 sqmm 2 core laid in trenches, fixed to pole/wall including taking down unserviceable complete any size, type & core complete all as specified and directed. Note:- Earth work, cable protection, sand fillings, cable joint shall be measured and paid separately.
All as per the description of srl item No 7 above item but 16 Sqmm 4 Core.
All as per the description of srl item No 7 above item but 25 Sqmm 3.5/4 Core.
M&L for painting of LT electric pole, steel tubular swaged pole (9 mtr long) of any size, any pattern with one coat of aluminium paint over a coat of red oxide primer in full length of the pole and marking the pole with black and yellow strip (upto to 1.50 mtr length, 1.50 mtr height of PCC coping) alternatively including numbering the pole serially all as directed.
M&L for high intensity retro reflective sheet 5cm width length up to 60 cm length as specified colours with heavy duty self adhesive tape for stick on electrical pole complete all as specified and directed.
M&L for disconnecting of all elecric supply, taking out electric incoming and out going cables from existing LT feeder piller of any size and any type, powder coated painting in inner & outer side complete over a cleaning, scraping with sand paper and removal of dust particles complete with necessary T&P, and refixing the same as incoming and outgoing cables as existing complete all as specified and directed.
S&F in repairs for loop box out door type made out of FRP type body one piece moulding type,Bus bar rating 63 Amps 4 strips aluminium with bus bar mounting colour R,Y,B,N on DMC unbreakable insulator with cable entry main supply from bottom side and pole light connection from back side, simens grey colour, shock prrof, rust proof, fire retardant size approx 300mm x 200mm x 100mm with 6/10 Amps MCB SP, having front, opening and locking arrangement, duly fixed on the pole by MS clamp of suitable sizes, all as specified and directed. Note:- Incoming and outgoing cables suitable size Lugs, Glands rate is deemed to be included in quoted rate against this item.
All as per the description of srl item No 13 above item but single phase system 2 strips aluminium bus bar size of approx 200mm x 150mm x 100mm all as specified and directed.
Labour for cutting and removing grass, vegetation bushes etc from surrounding HT installation/ LT Panel/ Four Pole structure/ Sub Stations and removing all rubbish to a distance not exceeding 50 m as directed.
Labour for trimming of tree branches around the street/ security light poles (not less than 2 mtrs) to clear the vegetation including cleaning of nest of birds, creepers on poles and stays etc complete removing and disposed off from the site complete all as specified and directed.
M&L for disconnecting of all elecric supply, taking out electric incoming and out going cables from existing feeder piller, removal of complete LT panel board/APFC panel/AMF panel inddor/out door type with necessary T&P, breaking of plinth, shifting and fixing of same feeder piller at new location including necessary eath work and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) work as directed and connecting of incoming and outgoing cables, inclusive of two coats synthetic enamel paint of existing colour over one coat of primer, including testing & commissioning etc., complete all as directed. Note: The cost of Aluminium thimbles/lugs and cable gland etc., as reqd at site is deemed to be included in quoted rate against this item.
M&L for replacement of lock assembly with key of old/existing LT panel board any type/size complete all as directed
M&L for replacement of door/MS sheet of old/existing LT panel board any type/size with cutting, welding & bend to shape and spray painting with powder coated paint with smoke grey paint in outer/inner side over one coat of primer after complete all as directed
M&L for replacment of double compression stainless steel gland suitable size for 16/25 sqmm 3.5/4 core LT power cables including restore of electric connection complete all as directed.
All as per the description of srl item No 20 above item but 35 to 50 sqmm 3.5 core LT cable
All as per the description of srl item No 20 above item but 70 to 120 sqmm 3.5 core LT cable
All as per the description of srl item No 20 above item but 150/185 sqmm 3.5 core LT cable
M&L for writing letters or figures (Block, Roman, Italic or Indian) n exc. 30cm high with synthetic enamel paint as per colour scheme complete all as specified and directed.
Material and labour for disconnecting faulty/burnt spreaders 3 pole/4 pole up to 400 amps MCCB rating in existing panel board and replace with suitable set of spreaders (03/04 Nos) complete all as directed.
M&L for disconnecting rotay handle direct type with accessories up to 400 amps MCCB rating in existing panel board and replace with same complete all as directed.
S&F in replacement of MCCB, 4 pole, 415V AC, 63Amps with breaking capacity 16kA, fixed/adjustable type including suitable spreaders of complete.
All as per the description of srl item No 27 above item but 100 Amps with breaking capacity 16kA
All as per the description of srl item No 27 above item but 125Amps with breaking capacity 16kA
Demolition of cement concrete of any description and in any position complete all as specified and directed.
M&L for PCC 1:4:8 type D2, (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C1, (Using 20mm graded crushed stone aggregate) as in foundations, for coping, filling and mass concrete with cement plastering fair finishing all as specified and directed.
M&L for cutting of road/path for laying of GI tubing and making the good to disturbed road/ path including provision of PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate all as specified and directed.
M&L for steel tubes, light grade galvanised 80mm bore laid in trenches/ walls and spreading for cable cushioning/ protection all as specified and directed including taking down old unserviceable complete.
All as per the description of srl item No 34 above item but 50mm bore.
M&L for street light bracket suitable for street/security light fittings upto 1.5m make out of GI pipe of light grade up to 40mm dia proper shaped, bended, threaded and drilling holes for wire entry and MS clamp of suitable size in proper shape and designed including taking down old corroded one all as directed and specified .
M&L for repairs in PVC, sheathed copper cable of 2.5 sqmm, 3 core for street light connection including taking down unserviceable PVC insulated aluminium conductor cable from steel pole /PCC pole /Jn box all as specified and directed.
S&F in repairs for street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 45 Watt including taking down old unserviceable one all specified and directed
S&F in repairs for street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 60 Watt including taking down old unserviceable one all specified and directed.
S&F in repairs for large area flood lighting system LED type IP 66, pressure die cast housing, with heat resistant tempered glass for protection with surge protection system, 120 Watt including taking down old unserviceable one all specified and directed.
S&F in repairs for decorative LED post top fittings 25W Ruby Clear/Coral opal type IP 65 including with all accessories complete along with after taking down old unserviceable one all specified and Make :Halonix/Philips/Wipro) Note: light grade GI pipe and necessary PCC works shall be measured and paid separately under relevant items
S&F in repairs for garden light fitting 10 watts, IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution (crompton LBLSN 10 CDL type) including taking down old fitting, demoliton of brick/PCC work all as specified and directed. Note: Necessary PCC works rates included in quoted rate
S&F in repairs for LED type IP 66, bush light with die cast aluminium having with toughened glass 9 W including fixing arrangements complete all as specified and directed.
Taking down defective street light fitting/flood lights any wattage, make,model from pole and repair the same including replacement of defective/faulty LED driver and re-fixing the same including connection complete all as directed
Removal of unserviceable PCC/Steel pole and M&L for steel tubular swaged poles complete with cast iron base plate final taper plug bolts/swan neck type nuts & screw all as specified and directed Type 410 SP 31 (9 Mtr long) with two coat of aluminium paint over a coat of red oxide primer in full length of the pole with black and yellow strip up to 1.5 mtr over PCC coping alternatively including numbering the pole and necessary excavation including dismantling the unserviceable pole with fittings etc complete all as specified and directed. Note: Excavation, demolition of concrete, PCC for foundation, coping and connected items shall be measured and paid separately under relevant items)
S&F in repairs of LT panel Voltmeter digital type for 415 Volts, 3 phase system, rating 0-500 V complete suitable for operation of LT Panel complete all as specified and directed.
S&F in repairs of LT panel Ammeter digital type for 415 Volts, 3 phase system, rating 0-200 A complete suitable for operation of LT Panel all as specified and directed.
S&F in repairs of LT panel Ammeter digital type for 415 Volts, 3 phase system, rating 0-400 A complete suitable for operation of LT Panel all as specified and directed.
M&L for checking of earth pit results, cleaning pit area complete, pouring of salt water as reqd in pit for maintaning of pit resistance up to less than 5 ohm complete all as specified and directed.
Repair of earth pit including required exacavation, earth work and PCC work to make good damaged/disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced and lifting handle on RCC cover with 8mm MS bars at 150mm centre to centre both ways including supply & fixing of wire mesh and funnel including re-connection of earth wire/strip with panel/transformer using GI nut, bolts & washer complete all as specified & directed
Material & labour for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron wire of 4mm dia as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 2009(Part-I) complete all as specified and directed .
All as per the description of srl item No 51 above item but using with Galvanised Iron strip of size 25mm x 4mm as earthing lead complete all as specified and directed.
All as per the description of srl item No 51 above item but using with copper earth plate electrode 60cm x 60cm x 3.15mm and copper strip of size 20X3mm as earthing lead and 40mm dia GI pipe for protection earth lead complete all as specified and directed.
S&F earth continuity conductor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole or any other situation for loop earthing etc as required 20mm x 3mm copper strip all as specified and directed.
S&F earth continuity conductor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole or any other situation for loop earthing etc as required 25mm x 4mm GI strip all as specified and directed.
Taking down carefully copper/aluminium point wiring (light/fan/socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc including making good the disturbed surfaces to match with the existing complete
M&L for point wiring with single core FRLS, PVC insulated, unsheathed multi stranded copper conductor of size 1.5 sqmm alongwith 1.5 sqmm earth wire of multi strand copper conductor (with same specification) casing caping/conduit pipe including replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the following :-
One light point controlled by one switch
One ceiling/exhaust fan point controlled by one switch
One socket outlet 5 Amps controlled by one switch on same board
One socket outlet 5 amps controlled by one switch on independent board
All as per the description of srl item No 59 above but wiring with 2.5sqmm copper wire and 1.5sqmm earth wire for socket out let 16 Amps on independent board
M&L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic suitable size PVC conduit complete with all PVC conduit accessories suitable for modular type switches/sockets/fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :- Note: 1. The quoted rate is deemed to be included for GI metal flush box of required modulars size, Modular cover inner and outer plates, blanking plates etc complete 2. Modular switch, sockets, Bell push measured and paid separately under relevant items.
One light point controlled by one switch
One ceiling/exhaust fan point controlled by one switch
One socket outlet 5 Amps controlled by one switch on same board
One socket outlet 5 amps controlled by one switch on independent board
One bell point controlled by one bell push switch
All as per the description of srl item No 61 above item but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 16 Amps socket outlet point on independent board with 1.5 Sqmm nominal cross sectional area copper conductor cable as continuous earth wire.
S&F in replacement of concealed metal box 18 to 24 modules having high durability, corrosion resistant,earthing terminal with repalcement of 3mm thick plastic laminated hylam sheet top cover with brass screws, cup wahser and cutting of grooves for switchs,sockets and regulator etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed. Note: Switch, sockets, regulators is to be measured and paid separately
All as per the description of srl item No 63 above item description but 10 to 16 modules complete all as specified and directed.
All as per the description of srl item No 63 above item description but 03/04 modules complete all as specified and directed.
All as per the description of srl item No 63 above item description but 01/02 modules complete all as specified and directed.
S&F switch piano flush type 5/6 Amps single pole one way 230 Volts complete all as specified and directed.
S&F switch piano flush type 15/16 A single pole one way 230 Volts complete all as specified and directed.
S&F socket Outlet 2 in 1, 3 pin 5 Amps flush type 230 Volt complete all as specified and directed.
S&F socket Outlet 2 in 1, 3/6 pin 5 and 15 Amp flush type 230 Volts complete all as specified and directed.
S/F bell push, flush type 5 Amps 230 Volts complete all as specified and directed.
S&F electronic fan step regulator flush type 120 watt, 230 Volt complete all as specified and directed.
S&F ding dong bell, AC, 230 volts, single pole complete all as specified and directed.
S&F lamp holder, 230 volt AC, PVC / Polycarbonate type of angular shape with back plate suitable for batten fittings complete all as specified and directed.
S&F ceiling rose, 6 Amps, 250 volts, AC with three terminals and PVC / Polycarbonate insulated body of 50mm x 25mm size complete all as specified and directed.
S&F modular switch 6 Amps, one way, one module 240 volts complete all as specified and directed.
S&F modular socket, 3 pin 6 Amps,240 volts, 2 module complete all as specified and directed.
S&F modular switch 16 A, 1 module,240 volts complete all as specified and directed.
S&F modular socket 6/16 A, 5 pin, 2 module, 240 volts complete all as specified and directed.
S&F modular bell push 6 Amps, one module 240 volts complete all as specified and directed.
S&F modular fan regulator, step type, 120 W, humfree, AC, 230 volts, 2 module complete all as specified and directed.
M&L in repairs for two single core (submain) PVC insulated cable with 4 sqmm nominal cross sectional area 1100 V,stranded copper conductor, multistranded, and one single core green PVC insulated 4.00 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making disturbed surfaces complete all as specified and directed.
All as per the description of srl item No 82 above herein before but with 6 sqmm two runs and 6 sqmm one run as earth wire
All as per the description of srl item No 82 above herein before but with 10 sqmm two runs and 10 sqmm one run as earth wire
S&F MCB DB, single pole and neutral with 200 Amps rated bus bar, 230 volts, glazed, double door type, 4 way IP-43, including connecting all connections of wire to MCBs with proper lugs & making good to the disturbed surface complete all as specified and directed.
All as per the description of srl item No 85 above but 8 way
All as per the description of srl item No 85 above but 12 way
S&F of factory made distribution box 4 way, AC, TP & neutral metal enclosure, Glazed double dooor, 415 V, AC, concealed type with suitable bus bar, neutral link, earth link suitable complete all as specified and directed.
S&F in repairs for MCB TPN, 240 Volts, AC, 32 to 63 amps, breaking capacity 10 KA, 'C' curve and connection by using suitable copper lugs complete all as specified and directed.
S&F in repairs for MCB, DP/SPN, 240 Volts, AC, 40/63 Amps of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs complete all as specified and directed.
S&F in repairs for MCB SP, 240 Volts, AC, 6 to 32 amps, breaking capacity 10 KA, 'C' curve and connection by using suitable copper lugs complete all as specified and directed.
S&F in repair of hylam sheet cover with brass screws , cup wahser and cutting of grooves 18 to 24 Modules for switchs,socket and regulator etc complete all as specified and directed. Note: 1. The quoted rates deemed to be included for removing of exist connections in switch board and after repair the same is to be refixed properly. 2. Switch, sockets, regulators is to be measured and paid separately under relevant items.
All as per the description of srl item No 92 above but 10 to 16 modules.
All as per the description of srl item No 92 above but 03/04 modules.
All as per the description of srl item No 92 above but 01/02 modules.
S&F in repairs of 200mm dia, 900 RPM, fresh air fan with plastic louvers including frame complete all as specified and directed.
S&F LED batten type fitting for surface/wall mounted 20/22W, 230V, 6500K integrated electronic driver completely pre wired, LED 4 feet fitting with polycarbonate housing & integrated electronic driver complete with connector block, screws, gutties etc.and removing the unserviceable fitting and all as specified and directed.
S&F LED batten type fitting for surface/wall mounted 9/10W, 230V, 6500K integrated electronic driver completely pre wired, LED 2 feet fitting with polycarbonate housing & integrated electronic driver complete with connector block, screws, gutties etc. and removing the unserviceable fitting and all as specified and directed.
S&F surface type LED panel type 36W,230V complete with driver full window glarefree opal diffuser LED panel of size 2ftx2ft with CRCA powder coated white housing, CDL/warm type illumination complete with all accessories required for connection and making good the disturbed any type of ceiling and remove the unserviceable fittings and all as specified and directed.
S&F surface type LED panel type 36W,230V complete with driver full window glarefree opal diffuser LED panel of size 4ftx1ft with CRCA powder coated white housing, CDL/warm type illumination complete with all accessories required for connection and making good the disturbed any type of ceiling and remove the unserviceable fittings and all as specified and directed.
S&F indoor decorative wall light fixture suitable for 10 W LED lamp,230V for soft light ambiance, made up of polycarbonate, spiral B22 base lamp holder used, globe shape, including LED lamp 10W (warm/CDL type) and remove the unserviceable fittings and all as specified and directed.
S&F lighting fixture wall mounted LED bulk head luminaire 9/10W,230V, made of die cast aluminium with opal diffuser IP 65, complete with mounting Brackets & accessories as required with connections and remove the unserviceable fittings and all as specified and directed.
S&F bldg security light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 65 protection and 25 Watt with suitabe size GI pipe bracket,clamps including taking down old unserviceable one all specified and directed.
S&F Indoor recessed/surface type mounted LED luminaires round/square type light weight plastic body downlight fitting 15 Watt, CDL/Warm type with all accessories 3 core copper wire for connection, making good the disturbed any type of ceiling and remove the unserviceable fittings and all as specified and directed.
S&F Indoor recessed/surface type mounted LED luminaires round/square type light weight plastic body downlight fitting 5 Watt, CDL/Warm type with all accessories 3 core copper wire for connection, making good the disturbed any type of ceiling and remove the unserviceable fittings and all as specified and directed.
S&F in repairs of 300mm dia, 900 RPM, exhaust fan metal body witlh louvers including frame, blades complete all as specified and directed. Note: Old fan retrieved from repairs shall be deposited in MES E/M store yard.
S&F in repair of 300mm dia, 900 RPM, wall mounting fan oscalating type complete all as specified and directed. Note:- Old fan retrieved from repairs shall be deposited in MES E/M store yard.
S&F of ceiling fan 5 star rated in white colour 1200mm sweep 220-240 volt with one set of 3 blades, down rod, hanger clamp PVC canopy complete all as specified and directed. Note: Old fan retrieved from repairs shall be deposited in MES E/M store yard.
S&F of water heater storage type, electric, capacity 25 Ltrs BEE 5 star rated, wattage 2KW, ABS plastic body, temparature indicating dial, enamel coated heating element, glass line coated inner tank, magnesium anode type, adjustable thermostat, inlet (cold water) and out let(Hot water) pipes including fixing with fasteners at wall and making good, finishing to disturbed surface to match the existing surface including connection complete all as specified and directed. Note: Old fan retrieved from repairs shall be deposited in MES E/M store yard.
S&F in repairs desert/Air cooler of body size 25"x25"x32", made out of corrosion resistant, 18 SWG GI sheet duly powder coated paint with 500mm sweep copper wound fan motor kit 180 watt with metallic blade, ISI marked, 1400 RPM, 230 volt AC, tank capacity not less than 100 ltr, including plastic submersible pumps, electronis fan regulator with P/switch, desert cooler to be fitted with 6mm thick plywood to cover the gap as required size at existing window complete all as specified and directed. Note:- Old unserviceable desert cooler depositrd in E/M Store yard.
NEETU TRADERS (INDIA)
M/s Prakash Enterprises
MK Enterprises
J V ENGINEERS / JAI SINGH
M P TYAGI ENGINEERS AND CONTRACTORS
Shiv Enterprises
M/s Sree Baba Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .