| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC NO 7 ARIEF MARICAR NAGAR VETTAIKARAN STREET THALATHERU KARAIKAL | L1 | Accepted-AOC Work order issued | |
| 2 | L2₹8.7 L+₹84,570 (10.8%)Rejected-Finance NO 46 SOUTH STREET KEEZHAKASAKUDY KOTTUCHERRY KARAIKAL 609 609 | KARAIKAL | PUDUCHERRY | 609609 | L2 | Rejected-Finance Unsuccessful tenderer | |
| 3 | L3₹9.1 L+₹1.3 L (16.2%)Rejected-Finance NO 55 SRI RAM NAGAR KARAIKAL | KARAIKAL | PUDUCHERRY | 609601 | L3 | Rejected-Finance Unsuccessful tenderer | |
| 4 | L4₹9.4 L+₹1.6 L (20.3%)Rejected-Finance NO 142 BHARATHIYAR ROAD KOTTUCHERRY KARAIKAL 609 609 | KARAIKAL | PUDUCHERRY | 609609 | L4 | Rejected-Finance Unsuccessful tenderer |
Tender Value
₹8.4 L
Closing Date
2 Nov 2021, 3:30 pmClosed
Executive Engineer
Executive Engineer, Buildings and Roads Division, Karaikal
Construction of toilet block at Government Primary School, Rayanpalayam in Kottucherry Commune.
2021_PWDC3_8636_1
15-03/PW/BRK/KKL/2021-22
Open Tender
Civil Works
Item Rate
90 days
GPS, Rayanpalayam
Please refer Tender documents.
6 documents required · 6 mandatory
₹525
Exempted
2 Dec 2021
26 Oct 2021
2 Nov 2021
26 Oct 2021
2 Nov 2021
26 Oct 2021
Amount
Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m - all kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m
Supplying and filling in plinth with river sand under floors, including watering, ramming consolidating and dressing complete
Supplying and filling with gravel (excluding rock) in trenches, plinth, sides of foundations etc . In layers not exceeding 20cm in depth consolidating each deposited layers by ramming and watering etc .complete including all lead and lift
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns,piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping,bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. upto floor five level, excluding the cost of centering ,shuttering and finishing - 1:5:10 (1 cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluing the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
Centering and shuttering including strutting, propping etc and removal of form for - Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc and removal of form for - Lintels, beams, plinth beams, girders, bressumers and catilevers
Providing, hoisting and fixing upto floor five level precast reinforced cement concrete in lintels, beams, and bressumers including setting in cement mortar 1:3 (1 cement : 3 coarse sand) , cost of required centering and shuttering but excluding the cost of reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing precast cement concrete jali 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning , fixing and finishing in cement mortar 1:3 ( 1 cement : 3 fine sand) etc. complete excluding plastering of the jambs, sills and soffits - 50mm thick
Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more
Brick work with common burnt clay F.P.S.(non modular ) bricks of class designation 3.5 in foundation and plinth in - cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 3.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:6 ( 1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level upto floor V level - cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance +_ 1mm ), with wall thick ness 2.0 mm (+-0.2mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws , joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S.tube of size 19x19 mm and 1mm (+-0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification - Extruded section profile size 42 x 50 mm
Providing and fixing to existing door frames - 30 mm thick factory made Polyvinyl Chloride (PVC) door shutters made of styles and rails of a uPVC hollow section of size 60 x 30 mm and wall thickness 2 mm (+- 0.2 mm) with inbuilt decorative moulding edging on one side . The styles and rails mitred and joint at the corners by means of M.S. galvanised / plastic brackets of size 75 x 220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x 20mm and 1mm (+- 0.1mm) wall thickness . The lock rail made up of 'H' section, a uPVC hollow section of size 100 x 30 mm and 2mm (+-0.2 mm) wall thickness, fixed to the shutter styles by means of plastic / galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multichambered single panel of size not less than 620 mm, having overall thickness of 20 mm and 1 mm (+_ 0.1mm) wall thickness . They panels filled vertcally and tie bar at two places by inserting horizontally 6 mm galvanised M.S.rod and fastened with nuts and washers, complete as per manufacturer's specification
Providing and fixing of 65mm Godrej Navatal lock of 6 levers etc complete
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc .complete - 40mm thick with 20mm nominal size stone aggregate
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manu -facturer), of approved make, inall colours, shades except burgundy, bottle green, black of any size as approved in skirting , risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement with pigment of matching shade complete
Providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make (Nitco / Kajaria) in colours such as white, Ivory, Grey, Fume red brown ,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including pointing the joints with white cement and matching pigment etc., complete
Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 110mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - Coupler - 110mm
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion -Single tee with door - 110x110x110mm
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - Single tee without door -110x110x110mm
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - bend 87.5 degree -110 mm bend
12mm cement plaster of mix -1:4 ( 1 cement : 4 fine sand)
15mm cement plaster on the rough side of single or half brick wall of mix - 1:4 (1 cement : 4 fine sand)
6mm cement plaster of mix 1:3 (1 cement : 3 fine sand)
White washing with lime to give an even shade - new work (three or more coats)
Finishing walls with acrylic smooth exterior paint of required shade - New work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm
Flush pointing with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for flat tile bricks on top of mud phaska - with F.P.S. brick tiles
Providing and fixing white vitreous china pedestal type water closet (European type W.C.pan) with seat and lid, 10 litre low level white P.V.C. flusing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS: 7231,with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required - W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15mm C.P brass pillar taps,32mm C.P.brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required - white Vitreous China wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete - external work - 20mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete - external work - 32mm nominal outer dia pipes
Providing and fixing C.P.brass bib cock of approved quality conforming to IS: 8931 - 15 mm nominal bore
Constructing soak pit 1.20 x 1.20 x1.20 m filled with brickbats including S.W.drain pipe 100 mm diameter and 1.20 m long complete as per standard design
Grading roof for water proofing treatment with - Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
ANBALAGAN G
RADJARAME P
M BASKAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .