| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹34.3 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | 1 | Accepted-AOC AOC | |
| 2 | 2₹36.8 L+₹54,507.45 (1.50%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | 2 | Rejected-Finance REJCTED DUE TO NOT L1 | |
| 3 | 3₹40.3 L+₹4.0 L (11.1%)Rejected-Finance | 3 | Rejected-Finance REJCTED DUE TO NOT L1 | |
| 4 | 4₹43.5 L+₹7.3 L (20.2%)Rejected-Finance | 4 | Rejected-Finance REJCTED DUE TO NOT L1 | |
| 5 | 5₹44.2 L+₹8.0 L (22.1%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | 5 | Rejected-Finance REJCTED DUE TO NOT L1 |
| Sl No | Description | Qty | Unit | MV Engineers And Contractors L5 | mayur enterprises L7 | Vijay Electricals L2 | M/s JAIMAA ASSOCIATES L4 | DS CONSTRUCTION L3 | Commercial Traders L1 | M P TYAGI ENGINEERS AND CONTRACTORS L8 | SB ENTERPRISES L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and directed by Engineer- in- Charge. | 696.6 | Cum | 120 ₹83,592 | 200 ₹1,39,320 | 100 ₹69,660 | 180 ₹1,25,388 | 100 ₹69,660 | 85 ₹59,211 Lowest | 99 ₹68,963.4 | 139 ₹96,827.4 |
| 2.00 | Material and labour for returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engineer- in- Charge. | 498.21 | Cum | 29 ₹14,448.09 | 100 ₹49,821 | 19 ₹9,465.99 | 40 ₹19,928.4 | 20 ₹9,964.2 | 15 ₹7,473.15 Lowest | 19 ₹9,465.99 | 39 ₹19,430.19 |
| 3.00 | Material and labour for removing excavated material (i.e. soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. | 198.39 | Cum | 29 ₹5,753.31 | 100 ₹19,839 | 19 ₹3,769.41 Lowest | 40 ₹7,935.6 | 20 ₹3,967.8 | 20 ₹3,967.8 | 29 ₹5,753.31 | 39 ₹7,737.21 |
| 4.00 | Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engineer- in- Charge. Note : Measurement shall be taken after punning down. | 139.32 | Cum | 360 ₹50,155.2 | 500 ₹69,660 | 400 ₹55,728 | 400 ₹55,728 | 300 ₹41,796 | 300 ₹41,796 | 299 ₹41,656.68 Lowest | 299 ₹41,656.68 Lowest |
| 5.00 | Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm.complete all as specified and directed by Engineer- in- Charge. | 5,733 | Each | 48 ₹2,75,184 | 35 ₹2,00,655 | 20 ₹1,14,660 | 55 ₹3,15,315 | 25 ₹1,43,325 | 21 ₹1,20,393 | 19 ₹1,08,927 Lowest | 29 ₹1,66,257 |
| 6.00 | All as per srl item No 5 here-in-before but using old cable cover obtained under srl item No 1 here in before complete all as specified and directed by Engineer- in- Charge. | 3,822 | Each | 5 ₹19,110 | 3 ₹11,466 | 1 ₹3,822 | 1 ₹3,822 | 0.1 ₹382.2 Lowest | 1 ₹3,822 | 9.99 ₹38,181.78 | 0.9 ₹3,439.8 |
| 7.00Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed of following sizes :- | |||||||||||
| 7.01 | 95 sqmm 3 core. | 350 | RM | 990 ₹3,46,500 | 1,000 ₹3,50,000 | 700 ₹2,45,000 Lowest | 800 ₹2,80,000 | 800 ₹2,80,000 | 743 ₹2,60,050 | 4,999 ₹17,49,650 | 999 ₹3,49,650 |
| 7.02 | 120 sqmm 3 core. | 950 | RM | 1,100 ₹10,45,000 | 1,100 ₹10,45,000 | 999 ₹9,49,050 | 950 ₹9,02,500 | 900 ₹8,55,000 | 900 ₹8,55,000 | 699 ₹6,64,050 Lowest | 1,189 ₹11,29,550 |
| 7.03 | 150 Sqmm 3 Core | 100 | RM | 1,290 ₹1,29,000 | 1,200 ₹1,20,000 | 999 ₹99,900 | 1,150 ₹1,15,000 | 1,100 ₹1,10,000 | 1,050 ₹1,05,000 | 799 ₹79,900 Lowest | 1,289 ₹1,28,900 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
11 Jul 2025, 6:00 pmClosed
GE UTILITY ELECTRIC SUPPLY
GE UTILITY ELECTRIC SUPPLY DELHI CANTT-10
REPAIR / REPLACEMENT OF 11 KV CABLE INCLUDING JOINTS, TRANSFORMER/RMU PLINTHS, FENCING, 11 KV BUS BAR CHAMBER AND TRANSFORMER, VCB, RMU, BATTERY CHARGER, RELAY AND CONNECTED ITEMS AT BI LINE, RRRC, KHYBER LINES, KHYBER LINE FAMILY QTR, ARJAN VIHA
2025_MES_715717_1
GE ELECT/D-23/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELECTRIC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE UTILITY ELECTRIC SUPPLY
₹96,000
Yes
18 Sept 2025
20 Jun 2025
14 Jul 2025
20 Jun 2025
11 Jul 2025
4 Jul 2025
Amount
Material and labour for excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and directed by Engineer- in- Charge.
Material and labour for returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engineer- in- Charge.
Material and labour for removing excavated material (i.e. soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engineer- in- Charge. Note : Measurement shall be taken after punning down.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm.complete all as specified and directed by Engineer- in- Charge.
All as per srl item No 5 here-in-before but using old cable cover obtained under srl item No 1 here in before complete all as specified and directed by Engineer- in- Charge.
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed of following sizes :-
95 sqmm 3 core.
120 sqmm 3 core.
150 Sqmm 3 Core
185 sqmm 3 core
240 sqmm 3 core
300 sqmm 3 core
Material and labour for boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe up to150 mm bore and making good both ends complete all as specified and directed by Engineer-in-Charge.
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah complete all as specified and directed by Engineer- in- Charge of following bore sizes :-
Supply and fixing of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed by Engineer-in-Charge of following size :-
50 Sqmm to 95 Sqmm 3 core.
120 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 400 Sqmm 3 core
Supply and fixing of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed by Engineer-in-Charge of following size :-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 400 Sqmm 3 core
Supply and fixing of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed by Engineer-in-Charge of following size :-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 400 Sqmm 3 core
Material and labour for earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground, (Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed by Engineer-in-Charge and shown in electrical plate number 3 of MES SSR part-I (1991)
Material and labour in replacement 32x6mm galvanised iron strip for earth continuity conductor for earthing of transformer, GOD, 4/6 pole, structure etc complete all as specified and directed by Engineer- in- Charge at site.
Material and labour for cutting and removing grass, vegetation bushes etc from surrounding 4 pole/6 pole HT structure, outside area of HT installation and removing all rubbish to a distance not exceeding 50 m complete all as specified and directed by Engineer- in- Charge.
Suplying and laying as replacement in sub station fixing 3.3 to 11 KV electrical insulation mat of size 5 mtr x 1 mtr x 2.5 mm thick specification complete all as specified and directed by Engineer- in- Charge.
Supplying and fixing in replacement LED flood light fitting made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by Engr-in-Charge of following size :-
Supplying & fixing of LED street light Fitting 60 watt LED, IP-66 protection, single piece pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 4.5 KV complete all as specified and directed by Engineer- in- Charge.
Supplying & fixing of LED street light Fitting 45 watt LED, IP-66 protection, single piece pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 4.5 KV complete all as specified and directed by Engineer- in- Charge.
S&F in replacement ACB 4 pole, 800 Amp, 50 KA, 415 Volt AC Horizontal draw out type, front operated with Micro processor based LCD protection release for adjustable over current, short circuit and earth fault protection complete all as specified and directed by Engineer- in- Charge.
Supply installation & commissioning in replacement of 12 Volts-100 AH sealed maintenance free battery complete all as specified and directed by Engr-in-charge.
Material and labour for disconnecting electrically & mechanically outdoor transforemrs upto 630 KVA capacity, lowering down/getting out from plinth carefully for repairing /making of plinth of transformer and re- connecting electrically and mechanically after repairing/making of plinth, testing and commissioning complete all as specified and directed by Engineer- in- Charge. Note:- (a) Rate is deemed to be inclusive for hydra, men power, and other items required for temp energization of transformer. (b) M&L used to repair the Plinth shall be measured and paid separetely under items of sch of work here-in -after.
Material and labour for brick masonry platform (suitable for 100 to 630 KVA transformer) having size 2.5 mtr x 2.5 mtr and total height 1.6 M (0.45 M below ground level including excavation and earth work, 1.15M above ground level including RCC slab 150 mm on top and refilling of sand/soil), PCC 1:4:8 type D-2 in foundation, sub class 'B' brick work in CM 1:4, 15mm thick rendering in CM 1:6 on all sides of platform upto 150 mm below ground level, supply and fixing of 02 Nos MS channels of suitable size for balancing of transformer, embedded in PCC 1:2:4 type B-1 up to 150mm thick RCC slab, including provn of stair case on one side complete all as specified and directed by Engineer- in- Charge.
Supply, installing, testing and commissioning in replacement of factory made and tested HT Panel board, size: 1200 mmx1200mmx900mm, cubical compartmentalized, out door type double door, suitable for 11000 Volts, 3 phase, 50 HZ AC supply system having bus bar chamber with insulated aluminium bus bars of size ,50 mm x 10 mm, 3 Nos installed on SMC insulators suitable for 11000 Volts. The panel shall be dust and vermin proof. IP-65 class protection and shall be made of 3.15 mm CRCA MS sheet, and 50x 50 x 6mm thick MS angle iron frame work, powder coated front and rear opening type, with apron for cable entry closing locking . The fixing of double doors shall be on MS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). including excavation, earth work and platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level complete all as specified and directed by Engineer- in- Charge.
Supply in replacement and Installation of HT CT operated Trivector Meter with the following specifications:- (a) Meter Type: HT 3 Phase 4 Wire Electronic Tri vector Meter (b) Standard: IS 13779:1999 / CBIP 88 (c) Accuracy: Class 0.5 (d) Voltage and Current rating:- (i) Reference Voltage - 3x240 V (ii) Basic Current (Ib) - 5 A (iii) Maximum continuous current (Imax) - 10 A (e) Rated Frequency (variation) - 50Hz (±5%) (f) Power consumption:- (i) Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency (ii) Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (g) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (h) Display in the event of Power Failure: Internal battery back-up for LCD display (j)Communication port: (iii) Energy recording - Unidirectional
Supplying & fixing in replacement of MS work of angles for post and struts of fencing around RMU/Transformer etc drilling holes, flat iron ,fillet for securing wire mess by welding to angle iron frame and framed work as in gate of angle and wire mess .Door to be fixed by 03 Nos 100mm long hinges and one sliding door bolt of 300mm long for locking arrangement and MS channel for plinth of transformer complete all as specified and directed by Engineer- in- Charge.
Supplying & fixing in replacement 3.15mm dia MS wire 75x75mm mesh , made up into mattress or cages appx 2.00 mtr height and fixed with flat iron /angle by welding in position complete all as specified and directed by Engineer- in- Charge.
Material and labour for 2 coat of synthetic enamel painting over a coat of red oxide to MS wire fencing including preparation of new surface complete all as specified and directed by Engineer- in- Charge.
Supplying & fixing in replacement of UNSV /Burnt MCCBs of capacity 400 Amps, FP, 35 KA, 415 Volts 50 Hz, AC, with microprocessor release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed by Engineer- in- Charge.
Supplying & fixing in replacement of UNSV /Burnt MCCBs of capacity 250 Amps, FP, 35 KA, 415 Volts 50 Hz, AC, with with microprocessor releaserelease fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed by Engineer- in- Charge.
Supplying & fixing in replacement of UNSV /Burnt MCCBs of capacity 160 Amps, FP, 25 KA, 415 Volts 50 Hz, AC, with thermal magneticrelease fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed by Engineer- in- Charge.
Supplying & fixing in replacement of UNSV /Burnt MCCBs of capacity 63 Amps, FP, 16 KA, 415 Volts 50 Hz, AC, with thermal magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed by Engineer- in- Charge.
Material & Labour for painting of transformer installed on plinth/4/6 pole structures at various site of capacity upto 630 KVA with existing colour, with spraying machine, after cleaning, preparation of outer surface of transformer, including writing of SM No, MES and capacity of transformer complete all as specified and directed by Engineer- in- Charge.
Supplying & fixing in replacement for Danger Notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white , with letters, figures and conventional skull and bobes in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25x20 cm size including taking down old one complete all as specified and directed by Engineer- in- Charge.
Supply installation & commissioning in replacement of 24V/40A Float Cum Boost Battery Charger unit including battery bank comprising 02 Nos of 12 Volts-100 AH sealed maintenance free battery. The CCCV battery charger consisting of copper wound, air cooled transformer, 01 Set single phase full wave bridge rectifier consisting of diodes and SCRs, liberally rated mounted on heat sink and complete with resistor/condenser network for surge supperssion . During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DC digital ammeter , DC digital voltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility for fuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom . The battery charger shall be divided into two compartments. The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:- (a) Input working voltage-180 -270 Volts (b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor - > 0.8 (d) On load unit watt efficiencies-> 80% (e) No load losses of complete charge-< 10% (f) Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j) Float charging -2.15 V/Cell (k) Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l) Reverse polarity -No damage will caused . A visual indication for reverse polarity will appear with an audio alarm. (m) Short circuit-MCB protecton provided. Make of battery charger :- Statcon/Sinetrac/Amar Raja
Supply, installation and testing in replacement Numerical Relay draw out type in HT 11 KV VCB Panel comprising of new and modern numerical scheme for detecting, indicating and tripping the breaker on faults over-current and earth-fault in any of the three phases, Trip circuit supervision relay, 5% pick up for OC and 5% for EF. The relay shall also have the following features as minimum; (i) Programmable rated current 1A & 5A, (ii) Last 8 fault record & 200 event record with time stamping, (iii) 4 analog CT & 3 PT input, 8 DI & 8 DO, (iv) Communicable on IEC61850 protocol, (v) Disturbance recording upto 300 cycles, (vi) Self supervision function. The relay shall be fully integrated with the feeder, internally capturing feeder statuses if available including Breaker On, Off, Spring Chrgd, Test, Service, AC-Fail, Trip circuit healthy relay, PT supervision, inter panel tripping, Master trip relay, local remote and display the same locally on a built-in LCD screen and suitably labeled status LEDs. Relay shall have facility to locally Trip/Close the breaker as a backup to TNC switch provided separately on the panel. The relay shall be fixed on new 2mm CRCA sheet of matching existing VCB panel color and suitable size covering all blank space formed by removing old mechanical type IDMT relay complete including associated wiring and integration with existing HT VCB panel complete all as specified and directed.,
Taking out faulty underground 11000 Volt HT cable of different sizes by excavation and removing PCC cover of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks complete all as specified and directed by Engineer- in- Charge. Note: (a) 11000 Volt HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable PCC cable cover will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
Supply and fixing of mild steel chequered plates Fe410-10-W(Gde-E-250) qualityon cable pit sizes as required on site 6mm to 10 mm thick including taking out old unsv RCC duct cover complete all as specified and directed by Engineer- in- Charge.
Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
Vijay Electricals (BID ID -3355084)
DS CONSTRUCTION (BID ID -3355399)
M/s JAIMAA ASSOCIATES (BID ID -3355123)
MV Engineers And Contractors (BID ID -3352818)
SB ENTERPRISES (BID ID -3354565)
mayur enterprises (BID ID -3354193)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3350856)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .