Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.2 L+₹19,465 (3.26%)Rejected-Finance 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹6.4 L+₹45,968 (7.70%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate category i.e c (i). |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
16 Dec 2021, 6:00 pmClosed
GE (AF) Bhisiana
Military Engineer Services, Garrison Engineer (AF), Bhisiana, Bathinda-151201
Repair and Maint of Internal Wiring, Summer appliances alongwith connected Items at AF Stn Abohar under GE (AF) Bhisiana
2021_MES_483276_2
GE/BHI-48/2021-22
Open Tender
Miscellaneous Works
Item Rate
60 days
GE (AF) Bhisiana
Please Refer Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Bhisiana
₹14,000
Yes
11 Feb 2022
2 Dec 2021
18 Dec 2021
2 Dec 2021
16 Dec 2021
2 Dec 2021
Amount
INTERNAL ELECTRIC SUPPLY
S&F in repair of 1x5 watt wall mounted, new generation LED batten for multipurpose application with LED Rod, made from exturded plastic housing, polycarbonate diffuser including all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr in Charge. Make : CG/Havells/Bajaj
S&F in repair of 1x18/20 watt wall mounted, new generation LED batten for multipurpose application with LED Rod, made from exturded aluminium housing, polycarbonate diffuser including all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge.
S&F in repair of new generation energy saving 9/10 watt LED bulk head (porch light fitting) made of plasitic housing with opal diffuser complete all as specified and directed by Engr-in-Charge. Make : CG/Havells/Bajaj
Taking down existing aluminum/copper Point wiring including wooden batten or taking out from existing complete (light/fan/socket) including all fittings such as ceiling rose, switches, regulators,sockets etc and making good distrubed surface of wall,floor & ceiling etc complete all as specified and directed.
M&L for Concealed Point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade drawn through and including non metallic rigid PVC conduit,medium grade minimum 19/20/25mm dia ISI marked and conduit accessories fixed concealed in wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings,switches,sockets outlets,regulators etc complete including provisining of 1.5 sqmm PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the following:-
One light point, ceiling fan/Exhaust fan point controlled by one switch 6 Amp one way.
One bell point controlled by one switch 6 Amp one way.
One 3 Pin Socket 5/6 Amp on the same board.
One 3 pin Socket 5/6 Amp on the independent board.
All as per item No 6 here in before but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed cable 1100 volt grade and 1.5 sqmm PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 Amp multi purpose socket combination point on independent board.
S&F in repairs switch piano flush type single pole 1 way 6 A, complete all as specified and directed.
S&F in repairs switch piano flush type single pole 1 way 16 A, complete all as specified and directed.
S&F in repairs bell push flush type single pole 1 way 5/6 A, complete all as specified and directed.
S&F in repairs Bell , AC, 230 volts, ding dong complete all as specified and directed.
S&F in repairs socket outlet 2 in 1, 3 Pin 5 Amps, flush type complete all as specified and directed.
S&F in repairs socket outlet 3 pin,15 Amps flush type complete all as specified and directed.
S&F in repairs stepped type electronic fan regulator flush type complete all as specified and directed.
S&F in repairs modular white cover plate with frame 1 module complete all as directed by Engineer in Charge.
S&F in repairs modular white cover plate with frame 3 module complete all as directed by Engineer in Charge.
S&F in repairs modular white cover plate with frame 6 module complete all as directed by Engineer in Charge.
S&F in repairs modular white cover plate with frame 8 module complete all as directed by Engineer in Charge.
S&F in repairs modular Switch 1 way 6 Amp, 1 module , complete all as specified and as directed.
S&F in repairs in Modular Bell Push Button 6 Amp, 1 module suitable for Call Bell and , complete all as specified and as directed.
S&F in repairs in modular Socket Outlet 6 Amp 2/3 pin combined 2 module, complete all as specified and as directed.
S&F in repairs modular Switch 1 way 16 Amp, 1 module , complete all as specified and as directed.
S&F in repairs modular Socket Outlet 6 Amp 6 pin combined 2 module, complete all as specified and as directed.
S&F in repairs modular Fan Step regulator 120W , complete all as specified and as directed.
S&F in repairs ceiling rose Polycarbonate, Isolated body surface type bakelite 65x50 mm three terminal complete all as specified and directed.
Taking down unserviceable and M&L for Submain wiring with two single core of 4.00 Sqmm and one single core of 4.00 sqmm as earth wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 volts grade drawn through in PVC Conduit (ISI Marked) of size 20/25 mm dia and the conduits accessories as in repairs complete including making good the distrubed surface to match the existing surface.
Taking down unserviceable and M&L for Submain wiring with two single core of 6.00 Sqmm and one single core of 6.0 sqmm as earth wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 volts grade drawn through in PVC Conduit (ISI Marked) of size 20/25 mm dia and the conduits accessories as in repairs complete including making good the distrubed surface to match the existing surface.
Disconnecting care fully old unserviceable main DB board etc. from site complete with wooden board and making good the disturbed surface complete all as specified and directed.
S&F in repairs Tripple pole and neutral (TPN) 4 way MCB distribution box double door powder coated sheet metal encloser 415 volts TPN including 200 Amps rated bus bar complete all as specified and directed.
S&F in repairs Single pole and neutral (SPN) 8 way MCB distribution box double door powder coated sheet metal encloser 240 volts including 200 Amps rated bus bar complete all as specified and directed.
S&F in repairs of Isolator Three pole & Neutral (TPN) 415 Volt 100 Amp, rupturing capacity 10 KA complete all as specified and directed.
S&F in repairs of Isolator Three pole & Neutral (TPN) 415 Volt 63 Amp, rupturing capacity 10 KA complete all as specified and directed.
S&F in repairs of MCB single pole (SP) B curve 240 Volt 6 to 32 Amp, rupturing capacity 10 KA complete all as specified and directed.
S&F in repairs of MCB single pole & Neutral (SPN) B curve 240 Volt 40 Amp, rupturing capacity 10 KA complete all as specified and directed.
S&F in repairs of MCCB 125 Amp 3 pole 50 Hz 415 volt thermal magnetic release type with breaking capacity 16 KA complete all as specified and directed by Engr in Charge.
M & L for Earthing complete with galvanized iron earth plate electrode 60 cm x 60 cm x 6.30 mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 5 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work, PCC pit with RCC cover, charcoal salt funnel, GI wire up to 7.5 mtrs length complete all as spd and directed.
Sypply and fix in repairs of MCCB 63 to 100 Amp 3 pole 50 Hz 415 volt thermal magnetic release type with breaking capacity 16 KA complete all as specified and directed by Engr in Charge.
Supply and fix in repairs 36/40 watt recessed mounted LED luminaire suitable for armstrong/grid ceiling with super bright LED fittings with connector block etc with short circuit protection , open protection , reverse polarity protection , high voltage protection complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
S&F in repairs 7 watt LED Bulb with base cap B22 type complete all as specified and directed by Engr in Charge.
Supply and fix in repairs 45 W IP 65 LED security light for building luminaire comprising of die cast aluminium housing with weather proof gasket for lamp & driver compartment with system wattage of 45 W . The LED make must be of CREE/NICHIA/OSRAM with 120 degree view angle , > 120 lumen/watt , lumen maintenance > 70 % at 50,000 hrs ,colour temperature of 5000- 6500K,>70 color rendering and LM 80 test compliance . The driver must be integral APFC and constant current type having THD <15% and power factor > 0.95 with short circuit protection , open circuit protection , reverse polarity protection , high voltage protection , protection against 10 KV high surges and comply to IEC 60598-1 , IEC 61000-3-2, IEC 61547. the luminaire must have secondary optics with perfectly matched lens for better light control complete all as specified and directed by Engr in charge.
S&F in repairs MCB DB TPN 4 way vertical type factory made IP 43 protection class metal double door with Shrouded Neautral Bar and Pan assembly with connecting link complete including provision of MCCB upto 125A after dismantling old one.
AIR CONDITIONING, CEILING FAN, GEYSER
Dismantling old defective/burnt sealed compressor of Refrigerator 165 to 310 Ltrs capacity replacement of the same with manufacture reconditioned compressor including soldering copper pipe with new compressor, charging of refrigerant gas R-134a in the system to its rated capacity, replacement of foundation rubber pad, nut and bolts, including testing on full load etc complete all as specified and as directed by Engineer-in-charge.
M&L for Cleaning the gas system with anti corrosive solution and recharging the refrigerant gas R-134a with anti moisture substance and replacement of filter along with rectification of leakage system in the refrigerator of capacity 165 to 310 Ltrs including installation at site and testing on full load etc
Supply and fix thermostatic switch with defrosting system suitable for refrigerator of capacity 165 to 310 Ltrs fixed in repairs complete all as specified and as directed by Engineer-in-charge.
Supply and Fix Starting relay assembly suitable for refrigerator of capacity 165 to 310 Ltr fixed in repairs complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repairs Plastic ice tray suitable for refrigerator of capacity 165 to 310 Ltr fixed in replacement complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repairs Vegetable tray with suitable glass cover suitable for refrigerator of capacity 165 to 310 Ltr fixed in replacement complete all as specified and as directed by Engineer-in-charge.
S&F in repairs in replacement fan blade for water cooler of any capacity all as specified and directed by engr-in-charge.
Repair to voltage stabilizer of capacity 02-05 KVA single phase including replacement of circuit plate, starting relay, voltmeter, fuse terminal box with fuse carrier, rewinding the main transformer with copper of existing size and repair / replacement time delay relay (1-2 Min) built-in type designed for low cut off 140/160 volt, high cut off 260/280 volt on single phase, 50 cycle AC supply etc complete all as specified and as directed by Engineer-in-charge.
Repair / replacement of condensing coil assembly complete suitable for Refrigerator of capacity 165 Ltrs to 310 Ltrs complete and recharging the refrigerant R-134 and testing all as specified and as directed by Engineer-in-charge.
Dismantling/taking down window type AC 1.5/2 Ton from site, opening, cleaning all dust with the help of air blower including cleaning of condenser and evaporator coil with Soap solution, removing the dust with the help of wire brush, repairing & proper fixing of wiring including thimbles and replacelment of Air filter Nylon and reinstalling AC in the same Location and made air tight to opening with thermacol material all around the window type AC complete and testing on full load etc complete all as specified and as directed by Engineer-in-charge.
Dismantling/taking down Split type AC 1.5/2 Ton from site, opening, cleaning all dust with the help of air blower including cleaning of condenser and evaporator coil with Soap solution, removing the dust with the help of wire brush, repairing & proper fixing of wiring including thimbles and replacement of air filter Nylon and reinstalling AC in the same location both unit outdoor/indoor unit complete and testing on full load etc complete all as specified and as directed by Engineer-in- Charge.
S&F in repairs starting relay assembly including cover and clips for air conditioner window type 1.5/2 Ton capacity fixed in replacement complete all as specified and as directed by Engineer-in-charge.
S&F in repairs running capacitor 36/45 mfd suitable for 1.5/.2 Ton capacity of window type AC fixed in replacement complete all as specified and as directed by Engineer-in-charge. Make : Dorson/Tibcon/Sharda/Havells
S&F in repairs capacitor 6 mfd suitable for blower motor,fixed in replacement complete all as specified and as directed by Engineer-in-charge. Make : Dorson/Tibcon/Sharda/ Havells
S&F in repairs thermostatic switch assembly suitable for window type AC of capacity 1.5/2 Ton , fixed in replacement complete all as specified and as directed by Engineer-in-charge.
Taking down dismantling of old unserviceable defective sealed compressor of cap 1.5/2 TR of window type AC/split AC and replacement with manufactures reconditioned compressor company make thermostatic sealed compressor of cap 1.5/2TR by soldering /brazing of copper Tubes and replacement of foundation pads including nut& bolt and washers as required and charging with Refrigerant R-22 to its rated capacity and testing of leakage in the system if any and making good, Testing on full load after reinstalling the same .
S&F in replacement fan blade for window/split AC of 1.5/2.0 TR all as specified and directed by engr-in-charge.
M&L for rewiring of complete window type AC of capacity 1.5 Ton with copper wire single core PVC cable of size 40/0.0076 with necessary sleeves, clip , thimble auto sweep switch etc. Make : Finolex/Plaza/Havells.
Supply & Fix cable of 3 core PVC sheathed copper flexible cable of size 70/0.0076 fixed in replacement complete all as specified and directed.
S&F Blower motor single phase 230 volts, 50 Hz, 1/5 HP, 900 RPM suitable for window type AC of capacity 1.5 Ton fixed in replacement complete all as specified and directed and suitable for existing make and model.
S&F Filter pad nylon type suitable for window type AC of capacity 1.5 Ton fixed in replacement complete all as specified and directed and suitable for existing make and model.
S&F Evaporator coil assembly complete suitable for window type AC of capacity 1.5 Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and directed by Engineer-in-charge.
S&F Condensing coil assembly complete suitable for window type AC of capacity 1.5 Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and directed by Engineer-in-charge.
S&F Front grill assembly complete suitable for window type AC of capacity 1.5 Ton fixed in replacement complete all as specified and as directed by Engineer-in-charge and suitable for existing make and model.
M&L for Cleaning the gas system with anti corrosive solution and recharging the refrigerant gas R-22/410A with anti moisture substance and replacement of filter along with rectification of leakage system in the window type AC of capacity 1.5 Ton including installation at site and testing on full load complete all as specified and as directed by Engineer-in-charge.
M&L for rewinding of blower motor of window type AC 1.5 Ton capacity single phase 1/5 HP, 900 RPM with super enameled copper wire of existing gauge including replacement of bush and nut and bolts, washer etc complete all as specified and as directed by Engineer-in-charge.
S&F Blower and blade assembly complete suitable for blower motor of window type AC of capacity 1.5 Ton fixed in replacement complete all as specified and as directed by Engineer-in-charge.
Preparation of old painted surface and applying two coats of Ducco paint by spray gun fully matched with its original colour outside of the window type AC of capacity 1.5/2 Ton including before painting removal of all dust with the help of air blower, sand paper and rubbing with cleaning compound and polishing on painted surface etc complete all as specified and as directed by Engineer-in-charge.
M&L for Cleaning the gas system with anti corrosive solution and recharging the refrigerant gas R-22/410A with anti moisture substance and replacement of filter along with rectification of leakage system in the split type AC of capacity 1.5/2 TR) Ton including installation at site and testing on full load etc complete all as specified and as directed by Engineer-in-charge.
S&F decorated frame of plywood/teak ply of size 70mm wide and 3mm thick duly varnished of good quality, all around the window type AC for air tight and fixing with screws on existing wooden frame complete all as specified and as directed by Engineer-in-charge.
S&F Insulation to refrigerant pipes of split ACs any make & type complete with suitable size for suction and discharge refrigerant pipes including necessary clamps etc.
S&F Remote control complete with all components suitable for window/split type ACs of capacity 1.5/2.0 Ton as per existing make complete all as directed.
M&L for Copper Pipe Line of size 1/2"/3/8" for Split type AC of any capacity complete all as specified and directed by engr in charge.
M&L for Copper Pipe Line of size 1/4"/5/8" for Split type AC of any capacity complete all as specified and directed by engr in charge.
M&L for Opeaning/Cutting holes in Brick wall suitable for window type AC 2/1.5 Ton and making good disturbed surface area complete with cement plaster and masonary work equired at site and made Air tight to Opeaning with the Thermocoal Material all round the window AC etc complete all as specified and directed by Engr in Charge.
S&F Starting relay assembly suitable for Water cooler of capacity 40/40, 40/80, 60/120, 120/150 Ltrs fixed in replacement , complete all as specified and as directed by Engineer-in-charge.
S&F Evaporator coil assembly complete suitable for Split type AC of capacity 1.5 Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and directed by Engineer-in-charge.
S&F Condensing coil assembly complete suitable for window type AC of capacity 1.5 Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and directed by Engineer-in-charge.
Taking down dismantling unserviceable/defective sealed compressor from water coolers of capacity 40/40, 40/80, Ltrs and replacement with reconditioned compressor including soldering/Brazing of copper tubes and fitted with foundation rubber pakts,nuts,bolts,washers etc. cleaning the refrigerant system with gas pressure and charging the refrigerant F in the system to its rated capacity, to check the leakage if any and made good and testing and full load after etc complete all as specified and as directed by Engineer-in-charge.
S&F Blower motor single phase 230 volts, 50 Hz, 1/16 HP, 1250 RPM suitable for water cooler of capacity 40/40/, 40/80, 120/150, & 150/180 Ltrs , fixed in replacement , complete all as specified and as directed by Engineer-in-charge.
S&F thermostatic switch complete suitable for water cooler etc , fixed in replacement , complete all as specified and as directed by Engineer-in-charge.
S&F chromium plated water tap push type suitable for water cooler etc , fixed in replacement , complete all as specified and as directed by Engineer-in-charge.
M&L for Cleaning the gas system with anti moisture solution and recharging the refrigerant gas with anti moisture substance and replacement of filter and copper capillary along with rectification of leakage system in the water cooler of any capacity including installation at site and testing on full load etc complete all as specified and as directed by Engineer-in-charge.
M&L for writing/marking of SM No /MES No of size 25mm synthetic enamel white paint on the water cooler/desert vooler/Split/window AC of various capacity/Split type AC's /Window type AcCs etc complete all as specified and as directed by Engineer-in-charge.
M&L for Fan motor single phase 230 volts, 50 Hz, 1/6 HP, 1250 RPM suitable for desert cooler of size 4000/5000 CFM, fixed in replacement , complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement blower motor single phase 230 volts, 50 Hz, 1/6 HP, 1250 RPM suitable for desert cooler of size 1800/ 3000 CFM complete all as specified and as directed by Engineer-in-charge.
S&F Submersible water pump for desert cooler 230 volts, 50 HZ, speed not less than 1300 RPM including replacement of mounting nut and bolts clamp etc , fixed in replacement , complete all as specified and as directed by Engineer-in-charge. Make : Star/Universal/Amikart
S&F PVC distributor suitable for desert cooler as per sample etc , fixed in replacement , complete all as specified and as directed by Engineer-in-charge.
S&F PVC pipe Heavy duty polythene ISI marked suitable for desert cooler as per sample etc , fixed in replacement , complete all as specified and as directed by Engineer-in-charge.
S&F Wooden wool pad as per sample suitable for desert cooler etc , fixed in replacement , complete all as specified and as directed by Engineer-in-charge.
M&L for Preparation of old painted surface after removal of all dust & foreign material with the help of sand paper and rubbing with cleaning compound and applying one coat of black Japan anticorrosion / black bituminous paint inside desert cooler body with paint brush and applying one coat aluminium paint of approved make out side the cooler body including pump, fan motor and body, with spray machine etc complete all as specified and as directed by Engineer-in-charge.
S&F Capacitor 4 mfd suitable for desert cooler fan motor etc , fixed in replacement , complete all as specified and directed.
Supply and fixing complete body of Desert cooler of medium size made out of plain sheet of size 1.00 mm thick of good quality in lieu of worn out body of desert cooler as existing complete all as specified and as directed by Engineer-in-charge.
M&L for Closing the opening all around the desert cooler in window with 6 mm thick plywood including cutting making to shape and fixing etc complete all as specified and directed .
Supply and fix float Valve high pressure of PTMT with epoxy coate Aluminium rod & high denesity plastc ball screwed for iron Pipe and fixed of Size 20/15 mm dia .
Supply and laying galvanised iron pipe, medium grade 20 mm bore with all new fittings, laid in trenches including jointing material etc complete all as specified and directed.
M&L for PVC Connections 15 mm Size with PTMT nuts of length 450 mm
M&L for Bib tap Standard of PTMT any colour high pressure screwed for iron Pipe and fixed of Size 20 mm dia. Make : Prayag/Polytuff/Shakti
M&L for Bib tap Standard of PTMT any colour high pressure screwed for iron Pipe and fixed of Size 15 mm dia. Make : Prayag/Polytuff/Shakti
M & L for Submain wiring with two single core of 4 Sqmm and one single core of 4 sqmm as earth wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 volts grade drawn through in PVC Conduit (ISI Marked)of size 20/25 mm dia and the conduits accessories as in repairs complete including making good the distrubed surface to match the existing surfce.
Supply and fixing single pole and netural enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amp 240 Volt all as specified and directed by Engr in charge.
Material and labour for replacement of PCB of Split AC capacity 1.5 TR of any make and all as directed by Engr-in-charge.
Material and labour for replacement of PCB of Refrigerator of capacity 165 to 310 Ltrs of any make and all as directed by Engr-in-charge.
Collecting Fans from 44 WEU Abohar ceiling /exhaust/wall mounted fans of any size and any make/model,moving to reputed workshop as approved by GE/Engineer-in-charge , dismantaling the same , cutting and removing the old defective/burnt out winding, cleaning the core of the fan motor, re-winding the fan motor by using machine with supper enemelled copper winding wire and using insulating materials, varnishing the assembly and re-assembling the fan including testing etc. complete all as specified and directed by Engineer-in-charge. MAKE of winding wire : Devi Dayal/Chetak/HTP Thulax. NOTE: All defective / unserviceable parts/items other than winding wire,varnish and insulating material, shall be measured separately and paid for under respective item of this schedule.
All as above item no 108 here-in-before but for ceiling fans any type/any size
All as above item no 108 here-in-before but for exhaust fans of 230/300 mm sweep any type complete all as specified and directed by Engineer in charge.
All as abive item no 108 here-in-before but for exhaust fans of 400/450 mm sweep any type complete all as specified and directed by Engineer in charge.
S & F in repair Capacitor 2.5 mfd complete all as specified and directed by Engineer-incharge.
S & F in repair Capacitor 3.15 mfd complete all as specified and directed by Engineer-incharge.
S & F in repair Capacitor 4 mfd complete all as specified and directed by Engineer-incharge.
Taking down carefully water heater (Geyser) any capacity any make after removing electric & water connections from existing system for carrying out repairs(Repairs will be measured and paid separately under appropriate items) and refixing the same after carrying out necessary repairs to original place all as directed by Engineer-in-Charge.
M&L painting with two coats of white synthetic enameled paint and marking MES No by black permanent marker and reconnecting the same after satisfactory completion of work all as directed by Engineer-in-Charge
Removing existing hot & cold water copper/PVC flexible pipe connection from geyser and S&F new brass chromium plated water pipe with brass nut and washers of good quality about 45cm long in hot & cold water connections and connecting complete
Replacement of heating element 2.0 kW for 25/35 ltrs capacity geyser ISI marked (as approved) all as directed by engr-in-charge.
Replacement of heating element 1.5 kW for 25/35 ltrs capacity geyser ISI marked (as approved) all as directed by engr-in-charge.
Replacement of thermostatic switch of geyser all as directed by engr-in-charge.
Supply and fixing Stop valves, cast copper alloy, screwed down, high pressure, with crutch screwed both ends for iron pipe or for unions of dia 15mm all as directed by Engr-in-Charge .
Cutting/drilling or taping from existing 15 or 20mm dia G I pipe in position for branch connection of 15mm dia including suitable fitting/fixtures all as directed by Engr-in-Charge.
M&L for replacement of fan blade of ceiling fan all as directed by engr-in-charge
M&L for replacement of fan blade of Exhaust fan all as directed by engr-in-charge
Detecting the leakage from geyser of any size/ any model and arresting the same by brazing/ soldering (as approved) all as directed by Engineer in Charge.
Note:- Certain Common items are appearing at different trades in the BOQ. Later BOQ will bifurcates accordingly. If the tenderer will quoted different rate of such items appearing at multiple places in the BOQ. Tendered will revise their rates to bring them whichever is lowest rate for all the repeated items.
M/s Luxmi Constructions
Rasvinderpalandco
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .