Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.1 LAccepted-Finance F 60 VIKAS PURI DELHI 110018 | WEST DELHI | DELHI | 110018 | L1 | Accepted-Finance Accepted | |
| 2 | L2₹40.2 L+₹16,950 (0.42%)Rejected-Finance | L2 | Rejected-Finance You are Not L-1 | |
| 3 | L3₹44.5 L+₹4.5 L (11.2%)Rejected-Finance 00 BALOD CHIKHLAKASA WARD NO 03 DALLI ROAD DURG CHHATTISGARH 491228 | BALOD | CHHATTISGARH | 491228 | L3 | Rejected-Finance You are Not L-1 | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Ram Charan Bansal Construction Private Limited L1 | Aditya Construction Co. L3 | M/s SPILLWAY INFRASTRUCTURE PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|
| 1.00 | Cleaning of sewer line by hiring of chassis mounted Super Sucker Machine along with trained manpower for perepherial sewer line as per the direction of Engineer in Charge ( 450 to 600 mm dia) | 11,000 | meter | 225 ₹24,75,000 | 250 ₹27,50,000 | 170 ₹18,70,000 Lowest |
| 2.00 | Cleaning of sewer line by hiring of chassis mounted Super Sucker Machine along with trained manpower for perepherial sewer line as per the direction of Engineer in Charge ( 650 to 750 mm dia) | 2,200 | meter | 300 ₹6,60,000 | 350 ₹7,70,000 | 290 ₹6,38,000 Lowest |
| 3.00 | Cleaning of sewer line by hiring of chassis mounted Super Sucker Machine along with trained manpower for perepherial sewer line as per the direction of Engineer in Charge ( 800 to 950 mm dia) | 1,700 | meter | 425 ₹7,22,500 | 450 ₹7,65,000 | 395 ₹6,71,500 Lowest |
| 4.00 | Plugging of the existing sewer line and Manhole with 2 Nos. MS sheet 6 mm thick with angle iron frame and braces shutters to be strutted with wooden struts and filling the manhole with empty cement (PVC) bags filled up with earth up to suitable depth to avoid leakage the sewerage on the u/s side to be pumped with suitable nos. and capacity of pumps, till the work is completed so as to keep reduce the pressure to be required extent to the plugged manhole. Necessary arrangement to be made for pumping of any leakage noticed in the manhole or to re-plug in the case of heavy leakage. The steel shutters and the earth filled PVC cement bags shall be removed after the completion of work and then the manhole shall be de-silted (450 to 550 mm dia) | 22 | meter | 4,500 ₹99,000 Lowest | 5,000 ₹1,10,000 | 24,300 ₹5,34,600 |
| 5.00 | Plugging of the existing sewer line and Manhole with 2 Nos. MS sheet 6 mm thick with angle iron frame and braces shutters to be strutted with wooden struts and filling the manhole with empty cement (PVC) bags filled up with earth up to suitable depth to avoid leakage the sewerage on the u/s side to be pumped with suitable nos. and capacity of pumps, till the work is completed so as to keep reduce the pressure to be required extent to the plugged manhole. Necessary arrangement to be made for pumping of any leakage noticed in the manhole or to re-plug in the case of heavy leakage. The steel shutters and the earth filled PVC cement bags shall be removed after the completion of work and then the manhole shall be de-silted (600 to 700 mm dia) | 5 | meter | 5,000 ₹25,000 Lowest | 6,000 ₹30,000 | 30,950 ₹1,54,750 |
| 6.00 | Plugging of the existing sewer line and Manhole with 2 Nos. MS sheet 6 mm thick with angle iron frame and braces shutters to be strutted with wooden struts and filling the manhole with empty cement (PVC) bags filled up with earth up to suitable depth to avoid leakage the sewerage on the u/s side to be pumped with suitable nos. and capacity of pumps, till the work is completed so as to keep reduce the pressure to be required extent to the plugged manhole. Necessary arrangement to be made for pumping of any leakage noticed in the manhole or to re-plug in the case of heavy leakage. The steel shutters and the earth filled PVC cement bags shall be removed after the completion of work and then the manhole shall be de-silted (800 mm dia) | 2 | meter | 6,000 ₹12,000 Lowest | 7,000 ₹14,000 | 36,800 ₹73,600 |
| 7.00 | Plugging of the existing sewer line and Manhole with 2 Nos. MS sheet 6 mm thick with angle iron frame and braces shutters to be strutted with wooden struts and filling the manhole with empty cement (PVC) bags filled up with earth up to suitable depth to avoid leakage the sewerage on the u/s side to be pumped with suitable nos. and capacity of pumps, till the work is completed so as to keep reduce the pressure to be required extent to the plugged manhole. Necessary arrangement to be made for pumping of any leakage noticed in the manhole or to re-plug in the case of heavy leakage. The steel shutters and the earth filled PVC cement bags shall be removed after the completion of work and then the manhole shall be de-silted (900 mm dia) | 2 | meter | 7,000 ₹14,000 Lowest | 8,000 ₹16,000 | 41,000 ₹82,000 |
Tender Value
Refer Docs
EMD Value
₹83,500
Closing Date
20 Sept 2025, 3:00 pmClosed
EXECUTIVE ENGINEER ( T ) M-1
M-16, Pocket- E , Mayur Vihar-II, Delhi -91
Cleaning of peripheral sewer lines ranging from 450 mm dia to 900 mm dia under EE(C) 1 for area under Assembly Constituencies AC 55 to AC 56 by hiring of jetting cum suction machine (Super Sucker) under SE(C)-01
2025_DJB_277847_2
NIT No. 33 (2025-26)
Open Tender
Civil Works
Works
210 days
M-16, POCKET-E MAYUR VIHAR PHASE-II
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
online
₹83,500
Yes
24 Oct 2025
8 Sept 2025
20 Sept 2025
8 Sept 2025
20 Sept 2025
8 Sept 2025
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .