COMPREHENSIVE MAINTENANCE OF CENTRAL AC PLANT OF 02X120 TR AND 03X20 INCLUDING REPLACEMENTS OF SPARES AT CHAF BANGALORE
2022_MES_547298_2
87464CWEAFNBAN
Open Tender
Civil Works
Item Rate
330 days
GE (AF) BANGALORE
AS PER NIT
6 documents required · 6 mandatory
₹500
GE (AF) BANGALORE
₹36,000
Yes
20 Dec 2022
12 Oct 2022
11 Nov 2022
12 Oct 2022
3 Nov 2022
20 Oct 2022
13 Oct 2022 - 14 Oct 2022
Amount
Overhauling of compressor including taking down unserviceable parts, refixing new parts wherever necessary complete including leak testing with nitrogen gas all as directed by Engineer in charge and testing the compressor for satisfactory performance for the Compressor. Model : SMC - 4- 65 S, Make : Accel.(Location- 3X20 TR AC Plant at Family wing) (Note : Spare parts required shall be measured and paid separately under respective items as 'Supply Only".)
Supply only following spare part of Compressor model No. SMC-4-65 Make :Accel (a) Piston
(b) Piston Ring
(c) Strainer suction assembly
(d) Oil Pump Assembly
(e) Bearing bush
(f) Oil filter
(g) 'O' Ring set
(h) Gasket set
(j) Connecting rod
(k) Ball bearing 3207
(l) Gudgen pin
(m) Suction & Discharge valve reeds
(n) Magnetic Strainer
Supply and fixing in repairs liquid line valve 20 mm dia as per existing make including brazing,welding work etc.Model No-DN 20WCB S,suitable for 3x20TR plant all as specified and directed
Supply and fixing in repairs liquid line valve 25 mm dia as per existing make including brazing,welding work etc.Model No-WCB DN 25 M,suitable for 3x20TR plant all as specified and directed
Supply and fixing in repairs solenoid valve as per existing make including brazing,welding work etc.Model No- IP67 Type-I size-2, suitable for 3x20TR plant all as specified and directed
Supply and fixing in repairs solenoid valve as per existing make including brazing,welding work etc.Model No- MKC-2, suitable for 3x20TR plant all as specified and directed
Supply and fixing in repairs expansion valve as per existing make-Danfos, including brazing,welding work etc.Model No-TEX 12,suitable for 3x20 TR plant all as specified and directed
Supply and fixing in repairs V belt , Model No- B77. Make:Fenner
Supply and fixing in repairs V belt , Model No- A76. Make:Fenner
Supply and fixing in repairs HP Cut out as per existing make suitable for 3x20 TR plant all as specified and directed. Make: Danfoss
Supply and fixing in repairs LP cut out as per existing make suitable for 3x20 TR plant all as specified and directed. Make: Danfoss
Supply and filling compressor oil-68 for 3x20TR all as specified and directed
Supply and fixing in repairs Oil pump assembly as per existing make, suitable for 3x20 TR Plant all as specified and directed Make- Accel
Supply and fixing in repairs of DOL starter . Model No-MK-I SS0001,suitable for pump set 3 HP, all as specified and directed Make L&T equivalent in Schneider/Siemens
Material and labour for carefully opening the motor of compressor for repairs and servicing by shifting to local work shop, taking out the burnt windings, cleaning of slots and rewinding the same with copper winding wire of existing gauge and quantity, heating applying shellac varnish to the windings, replacing insulating materials as required baking up and assembling back including replacing the bearings bushes using hydraulic pressure for 12.50 HP capacity 380/415 volt, 3 phase 50 HZ all as specified and directed
All as per item No.27 Above but 3 HP capacity for AHU/Condensers 380/415 volt, 3 phase 50 HZ all as specified and directed
All as per item No.27 Above but 2 HP capacity for cooling tower 380/415 volt, 3 phase 50 HZ all as specified and directed
M & L for taking out the monoblock pumping set 3 HP from the foundation after disconnecting and dismantling the water supply inlet and out let and plug it off, transporting the pumping set to local work shop and back for necessary repairs and replacement of bearing/bushes impellar and install at site replacement of corroded base plate tesing for its satisfactory performance of mono block pump set all as directed
Disconnecting & Dismantling the old Power cables, Circuit wiring and controlling accessories like MCCBs, Contactors , relays and timers from the existing pannel board of 20TR capacity AC plant replacing the power cables and circuit wiring with 10 sq mm and 4 Sq mm stranded copper cables including repairs/ replacing Contactors, timers and Relays. (Note:- Contactor ML1.5, ML 2, ML 3, Timers and relays will measure and paid separately under respective items of schedule.)
Supply and fixing in repairs over load relay of range 10 to 16 Amps ML1.5 starter with coil voltage 415 volt of all as specified and directed
Supply and fixing in repairs starter timer suitable for ML1.5 starter all as specified and directed.
Supply and fixing in repairs of contactor assembly suitable for ML 1.5 starter.all as specified and directed.
Material and Labour for painting with super Synthetic enamel paint two coats after cleaning and scrapping out the surface as required to machineries and accessories of the central air conditioning plant entral type 3x20 TR including one Nos. AHUs , condensor 03 Nos , compressor-03 Nos ,compressor motor -03 Nos ,Pump-02 Nos,LT Panel, Liquid line, discharge lines , suction line approx 25 mtr complete complete all as directed
M & L for descaling the condensers units of AC Plant capacity 3x20 TR after dismantling the inlet and out let of water/refrigerant gas connections and circulating descaling HCL acid/chemical with help of external pump, brushing the condenser tubes removing the scale neutralizing the base of tubes by circulating neutralizing agent replacement of rubber gasket for the end covers of the condenser removing the dummies connecting the water pipe line /refrigerant connections, removing the air,including refilling the removed refregerant(R 22) gas, leak testing checking gas pressure and testing complete all as specified and as directed.
M&L for cleaning to FRP base of cooling tower 3x20 TR capacity by dismantling coupling cooling fan, draining out of water, removing algey, silt etc, cleaning & servicing of mechanical components and welding to cross members and frame bracing components incl repair/over hauling the complete transmission system of cooling tower and re-assembling all the dismantled components to its original position, complete all as directed.
M&L for pressure testing and rectifying the leakages found in the system of 3x20 TR capacity including vacumizing and charging of the refrigerantgas to the desired pressure etc using nitrogen complete for satisfactory functioning all as specified and as directed. Note: Topping up of gas (R22) if required will be measured and paid seperately
Supply and fixing in repairs gun metal gate valves 50mm with iron wheel head screwed both ends for GI pipe of 3x20TR all as specified and directed
Supply onlyt of refrigerant (R-22) for 3x20TR plant all as specified and directed.
Overhauling of compressor including taking down unserviceable parts, refixing new parts wherever necessary complete including leak testing with nitrogen gas all as directed by Engineer in charge and testing the compressor for satisfactory performance for the Compressor. Model : ERDX1202, Make : Voltas. (Location - 2X120 TR AC Plant at OT Complex) Note : Spare parts required shall be measured and paid separately under respective items as Supply Only)
Supply only following spare part of Compressor model No. ERDX 1202, Make :Accel (a) Piston
(b) Piston Ring
(c) Strainer suction assembly
(d) Oil Pump Assembly
(e) Bearing bush
(f) Oil filter
(g) 'O' Ring set
(h) Gasket set
(j) Connecting rod
(k) Ball bearing 3207
(l) Gudgen pin
(m) Suction & Discharge valve reeds
(n) Magnetic Strainer
M&L for dismantling of electric driven induction motor of capacity up to 2 HP 230 volt, single phase 50 HZ of various AHUs for exhaust air of 2X120TR AC Plant repairs and servicing shifting to local work shop taking out the burnt windings, cleaning of slots and rewinding the same with copper winding wire of existing gauge and quantity, heating applying shellac varnish to the windings, replacing insulating materials as required baking up and assembling back including replacing the bearings bushes using hydraulic pressure all as specified and directed.
All as per Item No 55 above but of capacity 5 HP 380/415 volt, 3 phase 50 HZ of cooling tower 2x120TR AC Plant and AHUs of various OTs complete all as specified and as directed.
All as per Item No 55 above but motor of capacity 7.5 HP 380/415 volt, 3 phase 50 HZ of condenser water pump set of 2x120TR AC Plant complete all as specified and as directed.
All as per Item No 55 above but motor of capacity 12.5 HP 380/415 volt, 3 phase 50 HZof Chilled water pump set of 2x120TR AC Plant.complete all as specified and as directed.
M&L inreplacement electric driven induction motor as per existing make of capacity 1 HP 230 volt, single phase 50 HZ of various AHUs for exhaust air of 2X120TR AC Plant all as specified and directed.Make:Kirloskar
M&L for repair to chilled water Split casing pumpset of 12.5 HP for 2x120TR plant by disconnecting suction & discharge water lines and removing of electric connection, dismantling the U/S pumpset from MS foundation, opening the pump, remelting the shaft and filling of metal at decayed portions including all kind of machine works i.e. welding, turning, polishing etc as required to make the shaft of required shape and size, as original, balancing the shaft and refitting in pump body replacement of Cushy foot anti vibration pad with and including carrying out complete repair / replacement /servicing of damaged parts i.e. bearings bush, gland plate, gland packing, coupling cleaning of impeller assembly etc and reassembling the pump after greasing of moving parts and reinstallation of the pump with motor in original location using new MS stud, nut, bolt, washer and other packing material etc; checking the alignment; reconnecting the suction and delivery pipes, testing and commissioning for smooth operation complete all as directed.
All as per Item No 60 above but of Condenser water Split casing pump set of capacity 7.5 HP complete all as directed.
M & L for descaling the condensers units of AC Plant capacity 2x120 TR after dismantling the inlet and out let of water/refrigerant gas connections and circulating descaling HCL acid/chemical with help of external pump, brushing the condenser tubes removing the scale neutralizing the base of tubes by circulating neutralizing agent replacement of rubber gasket for the end covers of the condenser removing the dummies connecting the water pipe line /refrigerant connections, removing the air,including refilling the removed refregerant(R 134a) gas, leak testing checking gas pressure and testing complete all as specified and as directed.
Matrerial and labour for servicing of chilled Water cooled type cooling coil of AHUs of capacity 2400 to 3200 CFM/26-39GPM including cleaning of complete AHU and cooling coil with necessary chemicals/caustic soda liquid of required quantity, and giving final water wash and refixing the same,cleaning and drying of suction / disharge filters,blower and all accessories including replacement of connected canvas cloth of existing type between AHU and duct all as directed.
All as per Item No 63 here-in-above but for AHUs of capacity 3500 to 9800 CFM/52-96 GPM of chilled Water cooled type.
Dismantling the side cover of existing cooling tower carefully without damaging the other portion of cooling tower removing unserviceable PVC frills (130 Nos) carefully from cooling tower, and fix new PVC frills for cooling tower of 2x120 TR capacity including replacement of unserviceable bolts and Nuts etc of supporting media all as directed.
Supply and fixing in repairs of Condenser water pipe line of size 125 mm dia MS pipe of medium grade class 'B' black in colour all as specified and directed
Supply and fixing in repairs of Condenser water pipe line of size 150 mm dia MS pipe of medium grade class 'B' black in colour all as specified and directed
M&L for removing/cutting existing old rusted MS pipe line of size 125/150 mm to the required length and fixing new line in the existing position with necessary welding jointing fixing with suitable size/nos flanges, gaskets including bolts nuts washers complete on requisite PCC bed of suitable size and height as directed by Engineer incharge and painting of pipes with two coats of synthetic enamel paint of existing colour over a coat of primer all as specified and as directed. Note: (i) Rates are deemed to be included for providing necessary PCC work (ii) length of new pipe will measured and paid seperately under relavant item 66 & 67 above
Disconnecting & Dismantling the old Power cables, Circuit wiring and controlling accessories like MCCBs, Contactors , relays and timers from the existing pannel board of 120TR capacity AC plant replacing the power cables and circuit wiring with 10 sq mm and 4 Sq mm stranded copper cables including repairs/ replacing Contactors, timers and Relays. Note:- Contactor ML1.5, ML 2, ML 3, Timers and relays will measure and paid separately under respective items of schedule.)
Supply and fixing in replacement of power contactor of 6.3-9 Amp 415V AC rating, 03 pole, with 2NO+2NC Aux Contacts, 415V, with and including taking down of unserviceable contactor and making all electric connection, complete all as directed.
All as per srl item No 70 here-in-above but 32 Amps capacity.
All as per srl item No 70 here-in-above but 25 Amps capacity. Make Siemens or equivalent in Schneider/L&T
Supply and fixing in replacement of over load relay as per existing make ,range 20-32 Amps, direct / separate mounting on contactors, as required, with and incl taking down of unserviceable relay and making all electric connection, complete all as directed.
All as per srl item No 73 here-in-above but 12-16 Amps capacity.
All as per srl item No 73 here-in-above but 6-10 Amps capacity.
Supply and fixing in replacement of phase failure relay 3 Ph 415V 6-32A as existing type with high voltage, low voltage and neutral fail protection, complete all as directed.
S & F inreplacement Moulded Case Circuit Breakers of 63A 3 pole 415V 10 kA Fixed Thermal & Fixed Magnetic setting for Motor starter control mains complete all as directed.
S & F inreplacement Moulded Case Circuit Breakers 3 pole 415V 100A 16 kA Fixed Thermal & Fixed Magnetic settingfor LT panel control mains complete all as directed.
S & F in replacement Power contactor with in built conventional coil 230v/415v of Compressor motor starter of Cap upto 195/225 A type for 2x120TR AC Plant complete all as directed.
S & F in replacement Power contactor with in built conventional coil 230v/415v of Compressor motor starter of Cap upto 140/150 A type for 2x120TR AC Plant complete all as directed.
S & F in replacement push button, projecting head (push function) type, for controling the motors starters of cooling tower/water pumps etc complete all as directed.
S & F in replacement of LED type indicator lamp of red/yellow/blue/colour for phase indication, complete all as directed.
S & F in replacement Cast iron butter fly valve as per existing make, Hand liver operated ISI marked, PN - 1.0 pressure grade, having Nitrile/EPDM/nylon rubber lining, SS stem, CS/SS disc, of size 125 mm dia bore including all jointing material i. e. nut, bolt, washer, packing material etc, duly insulated on fixing complete all as directed.
All as per sl item No 83 here-in-above but 150 mm dia size.
S & F in replacement of gun metal gate valve of 20 mm dia bore size with iron wheel head, screwed inside, non-rising stem, complete all as directed.
All as per srl item no 85 here-in-above but of 25 mm bore size.
S & F in replacement of Air Vent valve, 20 mm dia ISI marked with and incl all fixing accessories, complete all as directed.
M & L for insulation for MS pipe of size 150 mm dia with PUF moulded type 40/50 mm thick with and incl applying bituminous compound and aluminium cladding with suitable gauge aluminium sheet with and incl taking down of old insulation and preparing of pipe surface by scratching / removing rust, dust and old paints etc with wire brush, emery paper, grinder etc and making surfaces smooth, complete all as directed.
All as per srl item no 88 here-in-above but of 80 to 125 mm bore size.
M&L for cleaning to FRP base of cooling tower 2x120 TR capacity by dismantling coupling cooling fan, draining out of water, removing algey, silt etc, cleaning & servicing of mechanical components and welding to cross members and frame bracing components incl repair/over hauling the complete transmission system of cooling tower and re-assembling all the dismantled components to its original position, complete all as directed.
M&L for applying one coat of primer and synthetic enameled spray paint of existing colour on 2x120TR Ac plants steel/iron surfaces of MS structurals,pipes ,motors, condensor inlet outlet pipeline incl preparing of surface by scratching / removing rust, dust and old paints etc with wire brush, emery paper, grinder etc and making surfaces smooth for achieving better grip between surface and primer, complete all as directed.
Supply and fix inreplacement pvc sprinkler set assembly as in existing make/ type/size of FRP cooling tower suitable for 2x120 TR capacity including removing of unserviceable sprinkler set with fittings/fixtures complete all as specified and as directed.
Supply and fixing inreplacement solenoid valve as per existing make including brazing,welding work etc.Model No- OC155 suitable for 2x120TR AC plant all as specified and directed
Supply and fixing inreplacement of thermostatic expansion valve including brazing and welding etc. Model No- 067N5185, Make- Danfos.
Supply and fixing water pressure gauge 0 - 10.6 kg and 4" dia ,as per existing make,suitable for condenser / Chiller water line including removing of old/unserviceable pressure gauge complete all as specified and as directed.
Supply and fixing suction/ discharge/oil pressure gauge of 0-150 PSI equivalent in Kg/ Cu cm ,as per existing make ,suitable for central type AC plant including removing of old unserviceable pressure gauge complete all as specified and as directed.
S & F resin bonded fibre glass insulation with 50 mm thick with one side factory laminated with aluminium foil wrapping around for existing ducts of any size including FRP Polyshield sheet of each layer of 1mm thick wrapped and held in position by 1.0mm dia GI wire around the duct from AHUs to wall entry into OTs to prevent water ingress where ever necessary including taking down old teared insulation with cover sheet complete all as specified
M&L for charging of refrigerant (R-134a).for 2x120TR plant all as specified and directed.
Supply and fixing inreplacement V belt A-61.
Supply and fixing inreplacement V belt A-60.
Supply and fixing inreplacement V belt A-43.
M&L for pressure testing and rectifying the leakages found in the system of 2x120 TR capacity including vacumizing and charging of the refrigerantgas to the desired pressure etc using nitrogen complete for satisfactory functioning all as specified and as directed. Note: Topping up of gas (R134a) if required will be measured and paid seperately
S& F inreplacement synthetic rubber insulating mat of size 2mx1mx3mm all as specified and directed.
M&L for servicing as in Preventive maintenance and repairs to centralised compressed air system to AFIDS consisting of reciprocating type air compressor with squirrel cage induction motor 3 phase 5 HP 2 Nos, compressed air receiver tank 500 litres capacity 1 No, cut out switches 2 nos, Air filter dryer, flow control valves for 16 Nos outlets distribution pipe line of 3/8" 1/2" & 3/4" dia complete including replacing of unserviceable spares, initial replacement of compressor oil and toping up as and when required basis, cleaning the complete system externally to keep the plant clean and tidy and satisfactory functioning through out the maintenance period to the entire satisfaction of Engr-in-Charge as and when ordered
M&L for dismantling of electric driven induction motor of capacity 5 HP 415 volt, 3 phase 50 HZ of centralised compressed air system repairs and servicing shifting to local work shop taking out the burnt windings, cleaning of slots and rewinding the same with copper winding wire of existing gauge and quantity heating applying shellac varnish to the windings, replacing insulating materials as required baking up and assembling back including replacing the bearings bushes using hydraulic pressure all as specified and directed
Material and Labour for painting with super Synthetic enamel paint two coats after cleaning and scrapping out the surface as required to machineries and accessories to the centralised compressed air system complete all as directed
S & F inreplacement DOL starter as in existing make, suitable for 5HP motor all as specified and directed .Make L & T/Havells/Standard
Supply and fixing inreplacement Air Pressure cut off switch as in existing make/type ,operates between 30-90 PSI for Air compressor plant fixed in replacement all as specified
Supply and fixing inreplacement Air filter as in existing make/size operates between 30-90 PSI for Air compressor plant all as specified and directed.
M&L for applying one coat of primer and synthetic enameled spray paint of existing colour on 3x20TR AC plants steel/iron surfaces of MS structurals,pipes ,compressor-03,pumps-02,cooling tower-01,AHU-01, incl preparing of surface by scratching / removing rust, dust and old paints etc with wire brush, emery paper, grinder etc and making surfaces smooth for achieving better grip between surface and primer, complete all as directed.
Supply & fixing in replacement of MS/GI hot dip galvanised/powder coated ladder type cable trays of width 300 mm, Height-75 mm and thickness 2.50 mm, including necessary coupler plates,Tees, cross,horizontal/vertical, nut and bolt arrangements complete all as specified and directed.
Supply & fixing in replacement of MS hot dip/powder coated perforated cover for cable tray of width 300 mm, thickness 2.50mm ,including necessary nut and bolt arrangements complete all as specified and directed.
Material and labour for mixed cement concrete (1:3:6) type M10 using 12.5 mm graded coarse aggregate for base to cable tray complete all as specified and directed.
M&L for complete cleaning of ducts by using HEPA filtered vaccum unit to create negative pressure in the duct system, by placing the same outside the accupied space by using variety of tools to agitate and loosen the dust, which shall be then drawn into the vaccum unit and contained therein. the cleaning should be done by using robotic video camera for cleaning the hard to reach areas, which are out of reach for most duct cleaning equipments. Access cutting can be made, if required and shall later be refitted with screw and sealant. All floors and furnishing where the work will be carried on shall be covered and complete care shall be taken to avoid minimum amount of cross- contamination. upon completition of work the system shall be sanitized by fogging the ducts to ensure all mold and bacteria spores and foul smell is eradicated the entire process shall be caried out with Air compressor with bib, pneumatic air whips and power jobs, Rotary brush Drum vaccum wit pipe. Negative machine HEPA and 10" hose pipe and Robo camera with control unit. All clening agents/chemicals used shall be inaccordance with the regulation and shall be certified for use in the respective system for the following AC Plants located at various location in CHAFB complete all as specified and directed by Engr-in Charge. (a)Package type AC Plants (i) Package type AC 2X8.5 TR Capacity (Location- CTVS OT)
(ii) Package type AC 1X11 TR Capacity (Location - ICCU)
(iii) Package type AC 2X7.5 TR Capacity (Location - Nuclear Medicine)
(iv) Package type AC 1X5 TR Capacity (Location- Nuclear Medicine)
(v) Package type AC 1X5.5 TR Capacity ( Location - CTVS OT Corridor)
(b) Central ACPlant 2X120 TR Capacity (Location - Main OT Complex) (i) AHU OT-1
(ii) AHU OT-2
(iii) AHU OT-3
(iv) AHU OT-4
(v) AHU OT-5
(vi) AHU OT-6
(vii) AHUPassage
B5BUILDING SOLUTIONS
UNIVERSAL ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .