Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.0 LAccepted-AOC LAMBA LINE PB NO 414 JUNGLIGHAT PO PORT BLAIR A N 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC L1 | |
| 2 | L2₹55.4 L+₹5.5 L (11.0%)Rejected-Finance | L2 | Rejected-Finance Not Bering L1 | |
| 3 | L3₹55.7 L+₹5.8 L (11.7%)Rejected-Finance 94A APR COLONY BILHARI JABALPUR MP | JABALPUR | MADHYA PRADESH | 482020 | L3 | Rejected-Finance Not Bering L1 | |
| 4 | L4₹56.5 L+₹6.6 L (13.2%)Rejected-Finance PB NO 809 ABERDEEN BAZAR PO ATLANTA POINT NEAR POLICE WIRELESS PORT BLAIR 744104 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744104 | L4 | Rejected-Finance Not Bering L1 | |
| 5 | L5₹57.5 L+₹7.6 L (15.3%)Rejected-Finance | L5 | Rejected-Finance Not Bering L1 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
4 Feb 2023, 6:00 pmClosed
GE Minniebay
GE Minniebay Junglighat Post Port Blair 744103 AN Islands
SPECIAL REPAIRS TO BLDG NO P-48 AT INS UTKROSH AND PROVN OF SPLIT AC AT NCS AND PROVN OF SMART ENERGY METER TO PRIVATE PARTIES UNDER GE MINNIE BAY PORT BLAIR
2023_MES_572656_1
8212/E8
Open Tender
Civil Works
Item Rate
180 days
Minniebay Port Blair
as per tender documents
10 documents required · 10 mandatory
₹500
GE Minniebay
₹92,000
Yes
4 Mar 2023
2 Jan 2023
6 Feb 2023
3 Jan 2023
4 Feb 2023
17 Jan 2023
Amount
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings including ridges complete all as specified and directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffolding at any height )
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings heads, shoes, bends, swan-necks etc (measured overall as fixed along the centre line over fittings and accessories complete all as specified and directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffolding at any height )
Taking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water , etc complete all as specified and directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffolding at any height )
Demolition of cement Concrete(unreinforced) including tiles and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
Taking up or down old/chocked water tubings 20 mm bore with fittings from trenches /walls for credit to contractor all as directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffolding at any height )
Taking up or down old/chocked water tubings 25 or 32 mm bore with fittings from trenches /walls for credit to contractor all as directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffolding at any height )
Taking down existing chowkats or frames exc 1.5 sq. m but n exc 4 sq. m each without taking off shutters from the frames complete all as specified and directed by Engineer-in-Charge.
Taking down existing chowkats or frames n.exc. 1.5 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed by Engineer-in-Charge.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the debris of the premises all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed by Engineer-in-Charge.
S& F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffolding at any height )
S& F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffolding at any height )
Supply & fixing in repairs aluminium Flat iron work in wind ties scrow as directed incul all necessary drilling ,bolting , riviting & etc complete all as specified and directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffolding at any height )
Dismantling of cast iron or reinforced concrete / PVC (SWR) drain pipes of size 75/100 mm dia, jointed in cement mortar and taking out of trenches, if required including fittings such as elbow,bend etc complete all as specified and as directed.
S&F in Repairs PVC (SWR) 160mm bore pipes single socketed with shoes , in any length with rubber ring joints fixed to walls , incl all necessary brackets , clamps , as in down take pipes complete all as specified and directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffolding at any height )
S&F in Repairs PVC (SWR) bends 160 mm dia complete all as specified and directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffolding at any height )
S&F in Repairs PVC (SWR) 110 mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or on wall complete all as specified and directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffolding at any height )
S&F in Repairs PVC (SWR) 75 mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or on wall complete all as specified and directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffolding at any height )
S&F in Repairs PVC (SWR) bends 110 mm dia complete all as specified and directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffolding at any height )
S&F in Repairs PVC (SWR) bends 75 mm dia complete all as specified and directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffolding at any height )
M&L for external rendering 5mm thick in CM 1:4 with water proofing compound (water proofing compound shall be used as per manufacturers instructions) over a coat of 10mm thick in CM 1:6 over block masonry or concrete surfaces finished even and fair surfaces complete all as specified and directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffolding at any height )
M&L for rendering 10mm thick on fair faces of brick/concrete surface in CM (1:6) finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering to ceiling in 5mm thick on fair faces concrete surface in CM (1:3) finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Supply only water proofing compound conforming to IS-2645 1975 complete all as specified and directed by Engineer-in-Charge.
M&L for oil bound distempering two coats over a coat of alkali resistant priming paint including preparation of new plastered or unplastered surfaces of wall complete all as specified and directed by Engineer-in-Charge.
M&L for oil bound distempering two coats over a coat of alkali resistant priming paint including preparation of new plastered or unplastered surfaces of ceiling complete all as specified and directed by Engineer - in -Charge. (Note :- Rate quoted is inclusive of Scaffoliding at any height )
M& L for two coat of whether proof exterior emulsion anti fungal paint with anti fungal property over a coat of primer and a coat of external wall putty on newly plastered wall surfaces including preperation of surfaces etc complete all as specified and directed by Engineer-in-Charge.
S & F Aluminium anodised section in (50 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, complete all as specified and as directed by Engineer-in-charge. (Note:- Weight of aluminium sections handles,hinges and locking arrangements shall be considered for payment. However cost of rubber packing required in the item shall be deemed to be included in the rate quoted. Glass panels, prelaminated particle boards, glass & aluminium wire cloth as reqquired shall be measured and paid separately in 'supply only' items.
Supply only 5mm thick sheet figured glass and glazing with rubber packing around the glass, in squares exceeding 0.50 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs 5 mm thick sheet figured glass and glazing with rubber packing around the glass, in squares exceeding 0.50 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed by Engineer-in-Charge.
M&L for preparing new or previously untreated surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of redoxide primer complete all as specified and directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffoliding at any height )
M&L For preparation of old plastered surface of wall and applying one coat of anti fungal Exterior emulision based premium quality matt finish exterior as per manufactors instruction complete all as specified and directed by Engineer-in-Charge. (Note :- Rate quoted is inclusive of Scaffoliding at any height )
S&F in repair aluminium anodised snap grid false ceiling of standard aluminium section such as wall angle of size 38mm x 25mm x 2.4mm weighing 0.36 Kg/Rm, Main/cross tees of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/Rm, grid size n.exc. 610 x 610mm suspended with 4mm dia GI wire at interval n.exc. 600mm centre to centre for main & cross tees fixed to roof slab, roof truss fixed with suitable size MS hook and fastening bolts etc including 'E' board classic 4mm thick oceanic sheet of size n.exc. 610 x 610mm size fixed in ceiling with clips to aluminium snap grid including preparation of new surface and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed by Engr-in-Charge
M&L for in Repairs Framed work as in brackets ,angles , or tees with web and flanges cut to shape , drilled ans counter sunk for scrow , incl bending and welding angles as necessary gusset plates, rails braces, etc. covering.g and fixing complete all as specified and as directed by Engr-in-Charge.
M&L mild steel work in Staircase/ladder (framed) including stringers, treads, landing, balusters, hand rails etc. including cleats, brackets, etc Fe-410- W(Gde- E-250) quality- A complete all as specified and as directed by Engr-in-Charge
S&F for Rolled sections/Tubular MS pipes as in cross beams, hip and jack rafters, vertical posts, purlins where connected to common rafters fixed with angle cleats or similar work including welding and all necessery works complete all as specified (Fe 410-W -(Gde E-250) quality A complete all as specified and as directed by Engr-in-Charge. Note : The rates are inclusive of Scaffoldings as required
S&F Plates (Plain or chequred), channels, square cut or notched forming holes, without any attachment including necessary welding complete all as specified and as directed by Engr-in-Charge.
M & L for Filleting in brick/block masonry not exc 25 Sqcm in any position and to any shape in cement mortar 1:4 including all mitres, stops complete all as specified and as directed by Engr-in-Charge.
M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting exc 10 cm but not exc 20 cm girth complete all as specified and as directed by Engr-in-Charge.
S&F 10 mm dia 100 mm long dash through fasteners bolt in concrete and brick work complete all as specified and as directed by Engr-in-Charge.
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed CM 1:6 complete all as specified and as directed by Engr-in-Charge.
All as per above Item No : 44 skirting / dado fixed with 10 mm thick backing cement coat C:M 1:4 complete all as specified and as directed by Engr-in-Charge.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed CM 1:6 complete all as specified and as directed by Engr-in-Charge.
All asper above Item No : 46 skirting / dado fixed with 10 mm thick backing cement coat C:M 1:4 complete all as specified and as directed by Engr-in-Charge.
M&L complete removal existing wall surface and applying two coats of oil bound distemper over a coat of alkali resistant priming paint including preparation of new plastered surfaces of wall complete all as specified and as directed by Engr-in-Charge.
Taking up or down 15/20mm bore steel tubing and connections, including fitting such as bend,coupler,elbow etc complete all as specified and as directed by Engr-in-Charge.
S&F of 20mm CPVC Pipes SDR 11 & plain CPVC SDR 11 fittings on walls / ceiling or laying in floor complete all as specified and as directed by Engr-in-Charge.
S&F of 25mm CPVC Pipes SDR 11 & plain CPVC SDR 11 fittings on walls / ceiling or laying in floor complete all as specified and as directed by Engr-in-Charge.
S&F Brass threaded Elbow CPVC pipe outer dia 20 mm complete all as specified and as directed by Engr-in-Charge.
S&F Brass threaded Elbow CPVC pipe outer dia 25 mm complete all as specified and as directed by Engr-in-Charge.
S&F Brass threaded Tee CPVC pipe outer dia 20 mm complete all as specified and as directed by Engr-in-Charge.
S&F Brass threaded Tee CPVC pipe outer dia 25 mm complete all as specified and as directed by Engr-in-Charge.
S&F Male brass threaded adopter CPVC pipe outer dia 20 mm complete all as specified and as directed by Engr-in-Charge.
S&F Male brass threaded adopter CPVC pipe outer dia 25 mm complete all as specified and as directed by Engr-in-Charge.
S&F Tank adopter CPVC pipe outer dia 20 mm complete all as specified and as directed by Engr-in-Charge.
S&F Tank adopter CPVC pipe outer dia 25 mm complete all as specified and as directed by Engr-in-Charge.
S&F Union CPVC pipe outer dia 20 mm complete all as specified and as directed by Engr-in-Charge.
S&F Union CPVC pipe outer dia 25 mm complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Ball valves high pressure with Epoxy coated aluminum rod & high density plastic ball screwed for iron pipe of 20mm bore all as specified and directed by Engr-in-Charge
S&F in replacement of Ball valves high pressure with Epoxy coated aluminum rod & high density plastic ball screwed for iron pipe of 25mm bore all as specified and directed by Engr-in-Charge
S&F in replacement of Ball valves high pressure with Epoxy coated aluminum rod & high density plastic ball screwed for iron pipe of 20mm bore all as specified and directed by Engr-in-Charge
S&F in replacement of Ball valves high pressure with Epoxy coated aluminum rod & high density plastic ball screwed for iron pipe of 25mm bore all as specified and directed by Engr-in-Charge
S&F in repair for 1000 Litres ISI marked rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including tank cover all as specified and directed by Engr-in-Charge
S&F in repair CP towel rail 20 mm dia, 60 cm long fixed with CP screws and wood cleats / rowel plug in wall, all as specified and directed by Engr-in-Charge
S & F in repair Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type heavy duty, 15 mm dia, with capstan head, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed all as specified and directed by Engr-in-Charge
S & F in repairs to Bib Taps, cast copper alloy heavy duty, 15 mm dia, Chromium Plated, Fancy Type screwed down for iron pipe and fixed etc complete all as specified and directed by Engr-in-Charge
S & F in repairs 15 mm dia bore cast copper alloy chromium plated angle cock/stop cock with long shank and cup screwed down high pressure with capstan head, screwed both ends for iron pipes or for union and fixed, complete all as specified and directed by Engr-in-Charge
S & F in repairs to Two way Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type screwed down for iron pipe and fixed etc complete all as specified and directed by Engr-in-Charge
S & F in repairs 32/40mm dia PVC flexible Waste Pipe, 750 mm long fixed to Wash Hand Basin or Sink complete all as specified and directed by Engr-in-Charge.
S&F in repairs PVC connection 15mm size with CP brass Nuts of legnth 600 mm complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 10 litre capacity PVC low level valve less syphonic action type flushing cistern, white, with inlet, ball valve, float and handle including brackets, and 32mm PVC pipe complete all as specified and directed by Engr-in-Charge.
S&F in repairs vitreous China wash hand basin of size 550 x 400mm white flat back including chromium plated, pillar tap, waste coupling, including brackets, PVC waste pipe, including cutting for and pinning in ends of brackets or erecting stand, complete all as specified and as directed by Engineer-in-Charge.
M&L for TMT bars 10mm dia and over as in reinforcement cut to length, bent to shape required including cranking hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing clips complete all as specified and directed by Engr-in-Charge.
All as per item no 77.00 as above but of 6 mm to 8mm dia in stirrups complete all as specified and directed by Engr-in-Charge.
M&L for form work for lintel , chajjas, slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick(Horizontal or sloping) complete all as specified and directed by Engr-in-Charge.
M&L for Reinforced cement concrete 1:2:4 ( Nominal mix) in Chajjas , slabs and similar type of work complete all as specified and directed by Engr-in-Charge.
M&L Precast cement concrete block masonry with PCC solid blocks in 1:3:6 type C1 using 20mm graded stone aggregates, exc. 10cm in width and set in CM 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection and finished even and smooth with using extra cement complete all as specified and directed by Engr-in-Charge.
S&F 18 to 20 mm thick HDF board incuding decorative laminations on bothsides , one side plain and another side decorative fixed to frame work complete all as specified and directed by Engr-in-Charge.
M&L for First class hard wood for wooden beading , cupboards / shelves / wardroble / wall panallling exc 6 ¬ exc 13 Sqm complete all as specified and directed by Engr-in-Charge.
S&F 100 mm brass handles, cast type, polished bright complete all as specified and directed by Engr-in-Charge.
S&F 100 mm size hasp and staple , safety type, brass with mild steel hinges pin incuding bolt to hinge plate with screws complete all as specified and directed by Engr-in-Charge.
S&F continuous (piano) hinges,mild steel, bright finish or electro galvanised and width of flaps 30 mm (when open ) complete all as specified and directed by Engr-in-Charge.
S&F Teak wood lipping frame 6 mm thick for 18/ 19 mm width fixed with nails/ screws complete all as specified and directed by Engr-in-Charge.
S&F Second class hard wood for plain , solid , straight , chowkats and frames , wrought , framed reabeated the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed by Engr-in-Charge.
S&F Magnet catch for cup boards of brass body and skirting plate complete all as specified and directed by Engr-in-Charge.
S&F in repairs only stainless steel friction stay hinges 200 x19 x1.90mm of standard size complete all as specified and directed by Engr-in-Charge.
Taking down old Energy Meter from the Shops/ houses and depositing it to MES store yard complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, Testing & Commissioning of Microprocessor based Single phase tamper proof electronic smart energy meter( pre paid/ postpaid)rating with 2 wire 240 Volts, 50 HZ, of range 5-60 Amps, confirming to IS 16444 with DLMS protocol , LED/LCD display and parameters like Voltage, Current, Frequency, Power, Power factor, KWh/ KVA,Network work topology GPRS/LONG RANGE RF compatible for smart energy billing system both post paid and prepaid with optional user based disconnection /reconnection through remote software and data export to MES ERP software as specified and as directed with 5 Years warranty. Note: - Quoted rate shall have deemed to be inclusive of following parameters: - (a) Meter reading record shall be submitted before and after replacement duly signed by the contractor rep and MES rep. (b) Any rejoining of wires /cables shall be done using suitable ferrule /cable connectors after removal of meter. (c) The cost of making good disturbed surfaces & matching to the existing surface is deemed to be included in the unit quoted rates.
Supply ,Installation ,Testing & Commissioning of Microprocessor based three phase tamper proof electronic smart energy meter (pre paid/ postpaid)rating with 4 wire 415 Volts, 50 HZ, of range 10-60 Amps, confirming to IS 16444 with DLMS protocol , LED/LCD display and parameters like Voltage, Current, Frequency, Power, Power factor, KWh/ KVA,Network work topology GPRS/LONG RANGE RF compatible for smart energy billing system both post paid and prepaid with optional user based disconnection /reconnection through remote software and data export to MES ERP software as specified and as directed with 5 Years warranty. Note: - Quoted rate shall have deemed to be inclusive of following parameters: - (a) Meter reading record shall be submitted before and after replacement duly signed by the contractor rep and MES rep. (b) Any rejoining of wires /cables shall be done using suitable ferrule /cable connectors after removal of meter. (c) The cost of making good disturbed surfaces & matching to the existing surface is deemed to be included in the unit quoted rates.
Supply, fixing testing & commissioning and configuration of (MDM system) Local Sever base own premise hosting software with life time license assigned grouping/ user level modules optional web based full fledged utility software with life time License for MDM Software. (i) Meter data management Modules : The meter data management module would be deemed for collecting the data from the meter to DCU and server vice versa, make the data available in bidirectional mode to the currency recharge, online payment gateway, post paid billing modules, scheduling maintenance, low balance warning, quarter wise Kva allocation/tripping, tariff configurations, software customisations etc as directed by Engr-in -charge. (ii) Secured Mobile App/ PC based/Swipe machine/ Online payment gateway for all users as directed. (a) 30min instantaneous data from all the meters for minimum seven parameters - cumulative energy, Power, Current, Voltage, Power factor and frequency. (b) Abstract download for monthly and quarterly billing survey data for cumulative energy and max demand and tampering features. (iii) Billing Module : The billing module capable to create data sheet for currency recharges, recharge history, maximum demand individually, user complaints registers, cheque/ payment reconciliations, fixed charges, energy bill details etc (iv) Occupation and Vacation module : Provision to enter admin controls for transfers / vacations. The system would support occupation/ vacation based on the unit categories.The system would support automatic data capture on occupation and vacation events. (v) Customer Module : The system would include a customer portal for the resident/occupants to log in and view their own energy/billing data. (vi) Energy Accounting module : The system would include features of energy accounting/ audit, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case tally with incomer EB energy meter. (vii) Communication Module : The system would provide communication of energy data and bills via print, email and sms methods. (viii) Meter Master Data : The system would support meter replacement process. (ix) Excel Export : the system would support export of metering and billing data in excel format to ERP.
Hosting and GPRS Charges per meter for Five years complete as specified and directed by Engineer-in-Charge.
Material & Labour for Provision of Static IP , Broad Band connection with High speed internet for 5 Years complete as specified and directed by Engineer-in-Charge. Note. MOU between Contractor and Telecommunicaiton Authority shall be submitted before the execution of work. The format of MoU shall be supplied by department for strict compliance.
Supply & Fixing of Laser-jet printer with single function black & white with USB connection with printing speed of min 18 pages per minute with resolution 600 x 600 x 2DPI.Printer complete as specified and directed by Engineer-in-Charge. Make: HP. Model: P1108.
Supply and fix All in one Desktop PC with dual core I7 processor 8GB RAM ,1TB HDD, Windows 10 PC 21.5” monitor 22 inch 1-CD/DVD Combo Drive R/WType,4 USB port including Video card, Cordless key board &Mouse with licensed Operating system (Windows 10) complete as specified and directed by Engineer-in-Charge. Make: Dell/HP/ Lenova
S & F UPS with following specifica&on complete all as specified and directed by Engr- in-Charge:- (a) Capacity of 600VA with output voltage 230V AC +10% of frequency 50HZ +1%. (b) Balery of 12 Volts , 7 AH-1 No with min 30 min backup with full balery condi&on. (c) Output waveform of pseudo Sine. (d) Off balery mode charging with high voltage protec&on. (e) Balery warrenty of atleast 2 years. Make : V-Guard, Modle No : Splender pluse 600/Luminous / Microtek
M&L Sub main wiring with 2 runs of 6 Sqmm single core, PVC FRLSH insulated, unsheathed 1100 Volts grade, multi-stranded, copper conductor cables drawn through PVC casing capping / Conduit with fitting/accessories, fixed on, walls, ceiling etc. as required including 06 Sqmm PVC FRLSH insulated, unsheathed, multistranded, copper conductor, single core cable as earth continuity wire complete as specified and directed by Engineer-in-Charge. Note : (i) PVC casing capping/ Conduit and its accessories measured and paid separately (ii) Two runs of cables and one run of earth wire shall be measured as one run length.
Supply and fixing hi-wall split units indoor/outdoor complete copper condenser including complete with cordless remote control unit, multi adjustable mode, anti microbial air filteration, inverter compressor, copper tube upto 3 mtr length and MS stand for outdoor unit, 5 Star rating of capacity 2.0 TR including testing complete all as specified and directed by Engr-in-Charge. Model : 245V Vectra Plus (4503456) of Make : Voltas or equivalent in Blue Star NOTE : The cost of all safety precautions arragement for working upto third floor, tools & plants etc., shall be deemed to be included in the quoted rate. (ii) The cost of core cutting in any type of wall and making good disturbed surface as per existing complete shall be deemed to be included in the quoted rate.
Supply and fixing hi-wall split units indoor/outdoor complete copper condenser including complete with cordless remote control unit, multi adjustable mode, anti microbial air filteration, inverter compressor, copper tube upto 3 mtr length and MS stand for outdoor unit, 5 Star rating of capacity 1.0 TR including testing complete all as specified and directed by Engr-in-Charge. Make : Voltas Model : 125V MDAZQ NOTE : (i) The cost of all safety precautions arragement for working upto third floor, tools & plants etc., shall be deemed to be included in the quoted rate. (ii) The cost of core cutting in any type of wall and making good disturbed surface as per existing complete shall be deemed to be included in the quoted rate.
Supply and fixing of wall mounted voltage stablizer for automatic operation, single phase naturally air cooled indoor type of designed for input variation between 170V to 270V with output voltage stablized at 230V with accuracy of +2.5% and capacity 5.0KVA complete all as specified and directed by Engr-in-Charge.
Supply and fixing of wall mounted voltage stablizer for automatic operation, single phase naturally air cooled indoor type of designed for input variation between 170V to 270V with output voltage stablized at 230V with accuracy of +2.5% and capacity 3.0KVA complete all as specified and directed by Engr-in-Charge.
Supply only Rigid non metallic PVC conduit (ISI marked) /PVC casing & caping 20 mm inclusive of all tees, bends, elbows, reducers and fixing accessories for drain outlet fixing on wall and floor complete all as specified and directed by Engr-in-Charge.
M&L for Taking down existing Split type AC unit (Indoor & Outdoor unit)1.5/2 ton capacity from old location of Navy Children School carefully by disconnecting existing electrical connection, suction and discharge refrigerant pipe line, removing aside, servicing by using blower/soap water for making dust free to the complete unit and applying lubricants to all the moveable parts and replacement of worn out bolts, nuts washers, split pin,remote battries etc at site and reassembling & fixing at new location of Navy Children School including testing complete all as specified and directed by Engr-in-Charge. NOTE : (i) The cost of all safety precautions arragement for working upto third floor, transportation for shifting of AC, tools & plants etc., shall be deemed to be included in the quoted rate. (ii) The cost of core cutting in any type of wall and making good disturbed surface as per existing complete shall be deemed to be included in the quoted rate.
Supply and fixing of Copper tubing of size 5/8" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and directed by Engr-in-Charge.
Supply and fixing of Copper tubing of size 1/2" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and as directed.
Supply and fixing of Copper tubing of size 3/8" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and as directed.
Supply and fixing Mild Steel stand heavy duty for Condenser outdoor unit of 1.5/2 TR AC complete all as specified and as directed.
Supply only Regrigerant gas R-32 in manufacturer's sealed cylinder complete all as specified and as directed by Engineer-in-Charge. Note: (i) Empty cylinder shall be returned to contractor. (ii) Payment shall be made for net weight of gas.
M&L for Submain wiring with PVC FRLSH insulated unsheathed multi-stranded copper conductor cable two run of 4 Sqmm single core (FRLS) 1100 volts grade drawn through in and including PVC rigid conduit medium grade for concealed wiring of not less than 20mm dia with conduit accessories and concealed in wall/ceiling or PVC Casing 'n' caping for surface wiring of suitable size with all accessories and one run of 4 Sqmm PVC FRLSH insulated copper conductor(FRLS) for earth continuity wire complete all as specified and as directed. Note : (i) Two run of single core cable with one run of earth continuity conductor and PVC conduit and PVC conduit accessories will be measured as one length. (ii) The cost of making good disturbed surface as per existing complete shall be deemed to be included in the quoted rate.
S&F Power unit modules 25A, 240V, 50HZ consists of 4 module surface mounting plastic box, 4 module cover plate outer & inner, 25Amps starter, 25Amps socket and plug top complete all as specified and as directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .