GE (AF) BHISIANA
GE (AF) BHISIANA PIN - 151201
PROVN OF MODERNISATION OF AFNET EQUIPMENT ROOM AND PROVN OF WEATHER SHELTERS SHED AND SECURITY POST AT MAIN GATE OF AF STN ABOHAR UNDER GE(AF) BHISIANA
2024_MES_669258_1
GE/BHI/CAP-04/2024-25
Open Tender
Civil Works
Item Rate
183 days
GE (AF) BHISIANA
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) BHISIANA
₹55,862
Yes
17 Dec 2024
31 Aug 2024
7 Oct 2024
31 Aug 2024
5 Oct 2024
19 Sept 2024
31 Aug 2024 - 12 Sept 2024
Amount
34W/44WEU(A)/CAP-03/2024-25 : PROVN OF MODERNISATION OF AFNET EQUIPMENT ROOM (B/R) (NIT: 1.94 L)
Dismantling wall & ceiling board any type, any thickness including cover fillets, complete all as specified & directed by Engineer in Charge.
M&L for Elegant Tile made of perforated cement fiber composite 595x595/295X1195/595X1195x5mm covered with absorptive microfiber coating on the front side and Acoustics fiber on the back side, water resistance, fire resistant absorption coefficient upto 0.89 at 160 Hz tested as per ISO 354. The tiles are anti-sag and installed on T24 grid system of 0.6mm thick Main 'T' length minimum 3000mm, web minimum 35mm to be placed at 600mm center to center and secondary cross 'T' of length 600mm web minimum 35mm inter locked, Wire Support for Main T to be taken at every 1200mm length wise and 600mm width wise, with a backing of 50mm 1000 GSM thick absorb wool tested as per Fire Retardant IS 15061-2002 for excellent results, complete all as specified & directed by Engineer in Charge.
S&F for Rolled Mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting Plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), conforming to Fe-2901 (Gde E-165), Quality A, complete all as specified and as directed by Engineer in Charge.
S&F for for Plates 6mm thick (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe-290 (Gde E165), complete all as specified and as directed by Engineer in Charge.
M&L for preparation of newly steel Surfaces of any des-cription, over 10cm in width or grith, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer in Charge.
Taking down cement plaster on brick or stone masonry Including raking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by Engineer in charge.
M&L for Rendering 15mm thick in CM (1:4) on fair faces of brick masonry/ concrete surface on wall and finishing the surfaces even and fair withoutusing extra cement , complete all as specified and directed.
M&L f applying two coat of oil bound distemper over Priming plastered (old/new) surfaces with alkali resistant priming paint including preparartion of surfacecomplete all as specified and as directed.
Dismantling floor , hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specifed and directed by Engineer in Charge.
M&L for Coloured Glazed ceramic tiles , ,on vertical surface 350x250x7 mm/450 x 350 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles including taking down existing finishes of wall surface, etc. laid over with 10 mm thick cement plaster in CM(1:4 ), complete all as specifed and directed by Engineer in Charge. NOTE : Cost of Rendering shall deem to be include in the Quoted Unit Rate.
34W/44WEU(A)/CAP-03/2024-25 : PROVN OF MODERNISATION OF AFNET EQUIPMENT ROOM (E/M) ( NIT: 13.08 L)
Supply , Installation , testing and commissioning of isolation transformer 10 kva copper wound 3 Phase , oil cooled 110% insulation resistance More than 100 M Ohms, VI Electric Strength Strength 2500V AC for 120 Sec, 50 HZ ON AN Cooled oil emersed copper wound indoor type isolation transformer complete with first filling of UIS 335 ISI marked filtered & dehydrated TFR oil electrostatic shield between primary 415v in delta connected & secondary 415 v staer connected complete & other stand and fitting including all accessories with vector gropup DYN-11. Note. (a) The contractor has to submit drawing of Isolation TFR and dully vetted by third party . (b) All specification of TFR should be match wiht latest IS (BIS) standard of india
S&F of LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 70 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed by Eng-in -Charge. (From Exc Source to Isolation TFR)
S& Fix of earthing complete with galvanised steel steel earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than 1.5 mtrs below nominal ground level connected to galvanised strip 32x6 mm by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No 3 of SSR Part I connected to earthing test point and testing on completion. all as specified and as directed. Note:- the cast of excavation and earth work PCC pit and PCC cover with handle, funnel & watering pipe, wiremesh,charcoal dust and common salt and earth strip up to 7.5 mtrs long shall be deemed included in the unit rate for earthing complete all as specified and as directed by Engineer in Charge.
M&L for PCC 1:3:6 with 20 mm graded stone aggregate for making foundation / making of approach path /support of pipe line for placing of rotational moulded polyethylene water storage tanks of capacity 500 Ltrs complete all as specified and as directed by Engineer in Charge.
M&L for supply installation and testing of maintenance free earthing system consisting of 99.9% pure copper solid rod type , UL approved copper bonded earth rod of 10 feet length, 17.2 mm dia. (as per drg) made of high tensile low carbon steel rod , molecularly bonded with 99.9% electrolytic grade copper on outer surface ( minimum copper bonding thickness - 250 microns) with exothermally jointed copper bus bar of 50 X 6 X 200 mm for connection. The rod and exothermic joint together successfully tested at 25 KA fault current by CPRI with 50 Kg eco friendly earth enhancing compound with each earth rod. The earth pit should be 125 mm dia. the compound should comply to IEC:62561-7 having passed leaching, corrossion, sulphur and resistivity test as per IEC: 62651-7 by NABL accredit Lab with FRP earth pit cover of top size lockable Lid. It includes GI Protection pipe light grade of size 40 mm dia. with GI strip of size 32X6 mm upto test point complete all as specified and directed. Note:- (a) Copper Strip connecting between two earthing will be measured and paid seperately in respective item. (b) Cost of Earthwork and neccessary PCC work for earthing pit is included in the above item. (c) Installation of earthing will be done by the company Engr at site. (d) Testing will be done by the company rap and 5 years guarantee certificate will be submitted by the company. and ISD for sum of 10% of quopted rate. (e) The test result of each set of earthing is less than 1 Ohm. All earthing test will be carried out in presence of MES Rep, manufacturer Rep and test result will be recorded in a register with sign of manufacturer & Engr-in-charge. (f) 5 Year gaurantee certificate from company for maintaining earth result less than 1 Ohm will be submitted by contractor. (g) 1425 RTC SS universal clamp of size 175 x 50 x 3mm. (h) Earth enhancing compound (PROCEM) ECS GB 25 tested as per IEC 62561-7-25Kg. (j) Chemical earthing will be installed by manufacturer Rep and purchase voucher of earthing will be produced before payment. Payment shall be made only after getting satisfactory result.
S&F test point terminal block made of gunmetal or phosphorus bronze size 75x75x25mm drilled and screwed incl 3 Nos 8mm dia 25mm long hexa head screw, complete all as specified directed and directed by Engr-in-charge.
S&F of Earth continuity copper conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated size of copper strip 20x3mm copper strip, complete all as specified directed and directed by Engr-in-charge.
Twsting :-On full and final installation of the voltage stabilizer, it shall be put on water load testing or testing with strip heaters. Testing shall be carried out by the Garrison Engineer/ Engineer-in-Charge for continuous running of 24 hours on full load including testing with 10% over load for one hour in between. The contractor shall make all necessary arrangement for testing including water/strip heaters load. During the testing of 24 hours on load, following aspects shall also be considered to ascertain the satisfactory performance of the voltage stabilizer: - (a) Noise level and temperature rise of oil. (b) Rate of voltage correction, sensitivity and response time. (c) Functioning of metering monitoring controls alarm and indicating.
M&L for sub main wiring (surface) /concealed complete with two single core 4sq mm FRLS stranded copper conductor cable drawn through pvc conduit casing and caping ( size of casing and caping as required in ground) including all accessories , fixing in walls/floors/ceiling with 4 sqmm copper earth continuity wire connected to earth dolly complete and making good the disturbed surface all as specified and directed Make: of cable : Polycab,Finolex,Havells . Note: 3 run of 4 sqmm & one run of PVC conduit shall be measured as single unit, complete all as specified directed and directed by Engr-in-charge. Note: The disturbed surface of wall for surfacce box wiring shall be make good by applying cement plaster, putty and colour wash etc matching with the existing surfaces. The rate for point wiring shall be deemed to include the cost of making good existing surface.
Supply and install invertor based split AC with cordless remote of capacity 02 TON ,(Copper coil Both Indoor & Out door Unit) electric driven single phase , 230 volts, New 4 star rating including all accessories like brackets, rubber tubing , copper tubing as required at site, gas charging , with auto filter clean technilogy etc including testing and commissionin with as per norms of BEE and making good to the disturbed surface to match the existing surface complete all as specified and directed by Engineer in Charge. Note :- All cooling /condensing coil should be copper material
Supply and install Voltage stablizer automatic operation single phase naturally air cooled indoor type & designed for input variation between 130 Volt to 280 Volt with output voltage stablized at 230 Volt with accuracy of (+/-)2.5 percent of capacity 5KVA. Make:V guard ,Steady Volt,Microtek, complete all as specified directed and directed by Engr-in-charge.
Supply and fix sheet metal enclosure with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB 20 Amps , 240 volts, complete all as specified directed and directed by Engr-in-charge.
Supply and fix PVC rigid conduit pipe 20/25 mm dia including all accessories and necessary saddles with fixing screwa, gutties etc. complete all as specified directed and directed by Engr-in-charge.
Supply and fix flexible U-PVC trunking of size 105x50 mm duly fixed on wall/floor all as specified and as directed complete all as specified directed and directed by Engr-in-charge.
Supply and Fix split AC stand of outdoor unit suitable for 1.5/2 ton including necessary fixing arrangement. complete all as specified directed and directed by Engr-in-charge.
S&F in replacement LCD Digital type AC timer for cyclic operation of 02 any type of Air Conditioner with displaying AC 1/AC 2 on indication & 1 to 24 hours programmable to take load upto 2 Ton window/split AC with auto/manual facility at site all as specified & directed by Engineer in Charge.
Supply and fix chemical dehumidifier continuous operating complete, with heaters, ducting, electrical connection for 1200 Cfm capacity, 440/220 V AC 50 HZ complete all accessoroes and inlet and out let connection all as specified directed and directed by Engr-in-charge. Make ISI/ BIS approved Mark
M&L for Addressable Fire Alarm Panel Pre Wired-Wall mounting Panel with MCBs, Terminals, Relay Board, Push Buttons, Power supply, IO Modules, Battery Set etc and Addressable Fire Alarm Panel as per below: • Suitable for 2 loops with required power/communication and IO modules • Self Verify function for automatic testing of detectors • Automatic addressing of detectors • AutroFieldBus • User-friendly Backlit display 16 x 40-character alphanumeric display and operator controls • Surface mounting on wall • Rack mounting in standard 19’’ cabinets • Conforms to applicable EU directives and regulations • Approved according to CEN Standards EN 54-2,EN 54-4 and EN 54-13, FM regulations (Factory Mutual) and maritime regulations (IMO/SOLAS and USCG) • Communication Ports : 2 Ethernet ports,2 USB host ports (max. 100mA), 1serial port for the std. detection loop communication protocol, 1 RS-232, RS-422 or RS-485 serial port for communication with third party Make: Autronica Model: 116-BS-420g/ Equivalent make, complete al as specifed adn as directed by Engineer in Charge.
S&F Addressable Optical smoke Detector with Base (IS type) and requires EX Barrier BZ-500 (Qty of Ex Barrier: Total 8 Nos i.e. 4 each for WSA-B & C Area) for use in intrinsically safe areas EX zone 1 and 2 made of white polycarbonate plastic having alarm LED, IP 44, Approval: EN54/ATEX/IECex, Deckhead Moulting Base for Termination with Mounting Accessories, glands etc. Make Autronica Model No 116-V-530-EX1A/ Equivalent make, complete al as specifed adn as directed by Engineer in Charge.
S&F Addressable Manual Call Point Break Glass type (IS Type) for use in intrinsically safe areas EX zone 1 and 2 and comprises the Self Verify function and built in Short circuit isolator made of GRP material, IP 66, Approval: EN54/ATEX/IECex, Deckhead Moulting Base for Termination with Mounting Accessories, glands etc.. Make: Autronica Model: 116-BF-501/EX, complete all as specifed adn as directed by Engineer in Charge.
Supply & fixing PVC insulated 2x1.5 sq mm ( 1 pair) PVC sheathed stranded armoured (ISI Marked) copper conductor FRLS cable on surface, including connection and steel conduit not less than 32mm dia with clam, etc. ccomplete all as specified directed and directed by Engr-in-charge.
Supply & fixing PVC insulated 4x1.5 sq mm ( 2 pair) PVC sheathed stranded armoured (ISI Marked) copper conductor FRLS cable on surface, including connection and steel conduit not less than 32mm dia with clam, etc. ccomplete all as specified directed and directed by Engr-in-charge.
Supply fix and test Cable tray perforated of 200 mm width, 70 mm height and of 14 Gauge powder coated including coupler plate, bends, angle iron 40x 40x 5 mm size at every one mtr for support with wall etc , complete all as specified directed and directed by Engr-in-charge.
S&F Addressable Horn Cum Strobe WP Type Type: LED, Red Sound Db: 100 db @ 1m Material: ABS IP Protection: IP42 with all required Mounting accessories i.e. Metallic mounting box, Glands etc Make: Autronica Model: 116-BBQ-230, complete all as specified directed and directed by Engr-in-charge.
Supply and laying underground type Optic fibre Cable(OFC) - Armoured FRLS Cable of 6 core, single mode (wired armoured) inside 50mm HDPE red colour pipe including root indicator suitable for repeater panel from fire alarm panel to fire station alongwith all suitable required devices like LIOU panel, fibre optic converters and picktails, etc complete all as specified directed and directed by Engr-in-charge.
S&F for Fingerprint Biometric Face Recognition Machine verex access control Wifi Based 1000 Users TCP/IP Software High Performance Facial System complete all as specified directed and directed by Engr-in-charge.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in deep for foundation of poles/stays/cables/Pipe lines etc and getting out in soft/loose soil, complete all as specified and as directed by Eng -in - Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers each not exceeding 25 cm thickness, complete all as specified and as directed by Eng -in - Charge.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and as directed by Eng -in - Charge.
Material and labour for sand cushioning with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches, complete all as specified and as directed by Eng -in - Charge.
Supplying & laying old size sub calss 'B' bricks laid flat in trenches over the cable with length of bricks perpendicular to the direction of cable, adjacent/abutting each other, complete all as specified and as directed by Eng -in - Charge.
S&F ECO FIRE Premium Clean Agent Automatic Modular Type Fire Extinguisher with Mount Hook with their use of Instruction Manual Capacity-5 kg complete all as specified directed and directed by Engr-in-charge.
34W/44WEU(A)/CAP-04/2024-25 : PROVN OF WEATHER SHELTER SHED AND SECURITY POST AT MAIN GATE (B/R) (NIT: 9.31 L)
Excavating in post holes (or similar holes) each not exceeding 0.5 Cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exceeding 50m and making good surface, complete all as specified and directed by Engineer in Charge.
M&L for Cement concrete 1:2:4 type B-2 ( 40 mm graded aggregate) in foundations, filling and mass-concrete complete all as specified and directed by Engineer in Charge.
S&F Mild Steel angle/flat iron/channel framed work such as iron gate fencing posts & parking sheds in cluding cutting tops to shape as directed, drilling holes nothing for wire etc falt iron fillets (fro securing wire mesh etc) including all necessary drilling bolting or reveting etc ans similar work, complete all as specified and directed by Engineer in Charge.
S&F Roof trusses (framed) , trussed purlins crane gantries rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces cleats etc complete all as specified and directed by Engineer in Charge.
S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer in Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer in Charge.
M&L for preparation of newly steel Surfaces of any des-cription, over 10cm in width or grith, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer in Charge.
M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and directed by Engineer in Charge.
M&L for Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer in Charge.
M&L for 15mm thick cement plaster in CM (1:6) on fair faces of brick or concrete surfaces and finishing the surface even and fair (without using extra cement) etc including applying two coats oil bound distemper (OBD) over a coat of primer and after preparation of plastered surfaces complete all as specified and directed by Engineer in Charge.
M&L for 15 mm thick plaster in 1:4 cement mortar and finishing the surface even and fair without using extra cement including applying two coat of cement base paint over and a coat of primer after preparation of new plastered surfaces complete all as specified and directed by Engineer in Charge.
M&L for Hard core of guage exc 63mm but not exc 100mm, deposisted spreaded and levelled in layers not exc15 cm thick watrered and rammed to a ture surface, complete all as specified and directed by Engineer in charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out, in soft/ loose soil , complete all as specified and directed by Engineer in Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm , complete all as specified and directed by Engineer in Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point , complete all as specified and directed by Engineer in Charge.
M&L for Non skid/Rectified coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM (1:6) for laying floor finishes complete all as specified and directed by Engineer in charge.
M&L for Non skid/Rectified coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm on vertical surfaces as in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick cement plaster in CM 1:4 to receive vertical tiles complete all as specified and directed by Engineer in charge.
M&L for fixing of granite 18-20mm thick of any type ( table rubbed and polished in steps, jambs pillars, window cill, cooking platform and like in cement mortar 1:4 incl pointing in white cement complete all as specified and directed by Engineer in charge.
M&L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection complete all as specified and as directed by Engineer in Charge.
M&L for Damp proof course to horizontal or vertical surfaces including necessary formwork, complete all as specified and as directed by Engineer in Charge.
M&L for Reinforced cement concrete Type-B1 nominal mix (using 20mm graded aggregate) for beams, cantilivers, beressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge.
M&L for RCC Slabs Type-B1 nominal mix (using 20mm graded aggregate) supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary form work, complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete raillings , opening in concrete walls, floors and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, hozontal or sloping and similar work exc 5cm but n exc 10cm etc.for fair finished surface complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; flat not exceeding 200mm thick (Horizontal or sloping) rough finish surface complete all as specified and directed by Engineer-in-Charge.
M&L for Mild steel TMT bars 10mm dia and over , cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns,footing, plinth beam, roof beam, lintels, slabs and other similar structures etc., hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge
All as per ser item no 25 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed by Engineer-in-Charge
M&L for Factory made single extruded WPC ) Wood Polymer Composite) solid door/window/ceosetory windows & other Frames/ Chowkat of size 45x70mm comprisisng of virgin PVC polymer of K value 58-60 (suspension Grade), Calcium carbonate and natural fibers (wood Powder/rice husk/wheat husk) and non txic additives (maximum toxicity index of 12 for 100 gms fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of of 750kg/cum, screw withdrawal strength of 2200N (face) & 1100 N (Edge), minimum copmressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resitance to spread of flame of glass A category with property of being termite/borer proof water/ moisture proof and fire retardant and fixed positions with MS hold fast'lugs/SS dash fasteners of required dia and length complete as per directios of Engineer-in-Charge. (M.S hold hold fast/lugs or SS dash fasteners shall be paid for separately)
S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising type flush door shutter of size 30mm thick comrising of viegin ploymer of valuve 58-60 (Suspension Grade) calcium carbonate and natural fibers (wood pwder/rice husk/wheat husk) and non toxic additives (maximum tocity indx of 12 for 100gms) having minimum dencity of 650 kg/cum and screw withdrawal strength of 1800N (Face) & 900 N (Edge) minimum compressive strength 50N/mm2 modulus of elasticity 850N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutters anf fixixng with stainless but hinges of requires size with necessary full body threaded star headed counter sunk S.S screw all as per direction of Engr-in-Charge
S&F 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S & F 150mm long stainless steel 204 grade bright finishd tower bolts of extruded section complete all as specified and directed by Engineer-in-Charge.
S&F butt hinges mild steel, medium weight 100 mm size with fixed complete all as specified and ditected.
S&F Extruded Aluminium handles, cast type, anodised of size 150mm complete all as specified and directed by Engineer-in-Charge.
S&F Powder coated Anodised aluminium frame for doors, windows, ventilators, partations with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer in Charge.
S&F Powder coated Anodised aluminium window and ventilator shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed by Engineer in Charge.
S&F Powder coated aluminium decorative grill of size of mesh 50mmX50mm fixed with doors, window for safety of glass etc. complete all as specified and directed by Engineer in Charge.
S&F sheet glass 5.5 mm thick ordinary quality and glazing with oil putty/ any type of beading in square/rectangular exceeding 1.00 Sqm in each pane complete all as specified and directed by Engineer in Charge.
S&F sheet glass 6.30 mm thick ordinary quality and glazing with oil putty/ any type of beading in square/rectangular exceeding 0.50 Sqm in each pane complete all as specified and directed by Engineer in Charge.
M&L for Non asbestos fibre cement boards 600x600x4mm thick fixed in ceiling Aluminium frame work with screws complete all as specified and directed by Engineer in Charge.
S&F Anodised aluminium snap grid frame work of grid 605x605mm for false ceiling complete all as specified and directed by Engineer in Charge.
M&L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS-15658-2006 of 60mm thickness M-35 Grade with grey cement and pigment complete all as specified and as directed by the Engr-in-Charge.
M&L for sand cushning 25mm thick for interlocking tiles complete all as specified and as directed by the Engr-in-Charge.
34W/44WEU(A)/CAP-04/2024-25 : PROVN OF WEATHER SHELTER SHED AND SECURITY POST AT MAIN GATE (E/M) (NIT: 3.58L)
S&F in replacement of LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 70 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed by Eng -in - Charge.
S&F in replacement of earthing complete with galvanised steel steel earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than 1.5 mtrs below nominal ground level connected to galvanised strip 25x4 mm by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No 3 of SSR Part I connected to earthing test point and testing on completion. all as specified and as directed. Note:- the cast of excavation and earth work PCC pit and PCC cover with handle, funnel & watering pipe, wiremesh,charcoal dust and common salt and earth strip up to 7.5 mtrs long shall be deemed included in the unit rate for earthing complete all as specified and as directed by Eng -in - Charge..
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.complete all as specified and as directed by Eng -in - Charge.
S&F of 170 watts LED Flood light for highly efficient LED Flood light with lens made of pressure die cast aliminium housing, extruded aluminium heat sinks & enclosed with toughened glass IP-66 fitted on the wall/ roof top/pole/ High Mast tower etc. with the help of nuts,bolts, clamps PCC work including connection with 2.5 Sqmm 3 core copper wire, complete all as specified and as directed by Eng -in - Charge. Note :- All T&P i.e ladder, tools, safety gloves etc will be provided by the contractor without any extra cost.
S&F of factory made LT feeder pillar box Outdoor type platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface with TPN aluminium bus bar of rating not less than 200Amps suitable foundation, complete all as specified and as directed by Eng -in - Charge. CPRI Approved make.
S&F of Time switches with battery backup 3P module, 24 hours programm, programable every 30 min, backup of 100 hrs current capacity 16 Ampscomplete all as specified and as directed by Eng -in - Charge.
S&F Tripple pole and neutral (TPN) 4 way MCB distribution box double door powder coated sheet metal encloser 415 volts TPN including 200 Amps rated bus bar complete all as specified and as directed by Eng -in - Charge.
S&F of MCB single pole (SP) B curve 240 Volt 6 to 32 Amp, rupturing capacity 10 KA complete all as specified and as directed by Eng -in - Charge.
S&F of MCB single pole & Neutral (SPN) B curve 240 Volt 40 Amp, rupturing capacity 10 KA complete all as specified and as directed by Eng -in - Charge.
Sypply and fix of MCCB 63 to 100 Amp 3 pole 50 Hz 415 volt thermal magnetic release type with breaking capacity 16 KA complete all as specified and as directed by Eng -in - Charge.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in deep for foundation of poles/stays/cables/Pipe lines etc and getting out in soft/loose soil, complete all as specified and as directed by Eng -in - Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers each not exceeding 25 cm thickness, complete all as specified and as directed by Eng -in - Charge.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and as directed by Eng -in - Charge.
Material and labour for sand cushioning with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches, complete all as specified and as directed by Eng -in - Charge.
Supplying & laying old size sub calss 'B' bricks laid flat in trenches over the cable with length of bricks perpendicular to the direction of cable, adjacent/abutting each other, complete all as specified and as directed by Eng -in - Charge.
M&L for Submain wiring with two single core of 4.00 Sqmm and one single core of 4.00 sqmm as earth wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 volts grade drawn through in PVC Conduit (ISI Marked) of size 20/25 mm dia and the conduits accessories as in repairs complete including making good the distrubed surface to match the existing surface.complete all as specified and as directed by Eng -in - Charge.
NOTE: BoQ has bifurcated job wise, if bidder quoted different rate for same item at two jobs then lowest quoted rate shall be considered for acceptance.
VIVEK CONSTRUCTION CO (BID ID -3125819)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .