Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.7 LAccepted-AOC | 1 | Accepted-AOC Accepted being L1 | |
| 2 | 2₹28.1 L+₹37,716.80 (1.36%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | 2 | Rejected-Finance Rejected being not L1 | |
| 3 | 3₹29.0 L+₹1.3 L (4.77%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | 3 | Rejected-Finance Rejected being not L1 | |
| 4 | 4₹30.3 L+₹2.6 L (9.41%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | 4 | Rejected-Finance Rejected being not L1 | |
| 5 | 5₹31.3 L+₹3.6 L (12.9%)Rejected-Finance WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | 5 | Rejected-Finance Rejected being not L1 |
| Sl No | Description | Qty | Unit | MV Engineers And Contractors L4 | Commercial Traders L7 | Rajindera Enterprises L6 | Vijay Electricals L2 | ALLIED CONSTRUCTION L1 | mayur enterprises L5 | M P TYAGI ENGINEERS AND CONTRACTORS L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes:- Note:- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately under respective items of schedule. | ||||||||||
| 1.01 | 16 Sqmm 4 core | 350 | RM | 131 ₹45,850 | 149 ₹52,150 | 150 ₹52,500 | 125 ₹43,750 | 120 ₹42,000 Lowest | 140 ₹49,000 | 189 ₹66,150 |
| 1.02 | 35 Sqmm 3.5 core | 550 | RM | 191 ₹1,05,050 | 220 ₹1,21,000 | 210 ₹1,15,500 | 180 ₹99,000 | 170 ₹93,500 Lowest | 200 ₹1,10,000 | 249 ₹1,36,950 |
| 1.03 | 50 Sqmm 3.5 core | 480 | RM | 276 ₹1,32,480 | 305 ₹1,46,400 | 300 ₹1,44,000 | 254 ₹1,21,920 | 235 ₹1,12,800 Lowest | 260 ₹1,24,800 | 299 ₹1,43,520 |
| 1.04 | 70 Sqmm 3.5 core | 280 | RM | 379 ₹1,06,120 | 414 ₹1,15,920 | 400 ₹1,12,000 | 333 ₹93,240 | 300 ₹84,000 Lowest | 350 ₹98,000 | 459 ₹1,28,520 |
| 1.05 | 95 Sqmm 3.5 core | 660 | RM | 451 ₹2,97,660 | 515 ₹3,39,900 | 500 ₹3,30,000 | 420 ₹2,77,200 | 390 ₹2,57,400 Lowest | 450 ₹2,97,000 | 499 ₹3,29,340 |
| 1.06 | 120 Sqmm 3.5 core | 250 | RM | 569 ₹1,42,250 | 650 ₹1,62,500 | 600 ₹1,50,000 | 550 ₹1,37,500 | 490 ₹1,22,500 Lowest | 650 ₹1,62,500 | 599 ₹1,49,750 |
| 1.07 | 150 Sqmm 3.5 core | 341 | RM | 657 ₹2,24,037 | 760 ₹2,59,160 | 700 ₹2,38,700 | 600 ₹2,04,600 Lowest | 600 ₹2,04,600 Lowest | 850 ₹2,89,850 | 699 ₹2,38,359 |
| 1.08 | 185 Sqmm 3.5 core | 363 | RM | 765 ₹2,77,695 | 940 ₹3,41,220 | 900 ₹3,26,700 | 775 ₹2,81,325 | 750 ₹2,72,250 Lowest | 1,000 ₹3,63,000 | 999 ₹3,62,637 |
| 1.09 | 300 Sqmm 3.5 core | 400 | RM | 1,281 ₹5,12,400 | 1,440 ₹5,76,000 | 1,400 ₹5,60,000 | 1,158 ₹4,63,200 | 1,150 ₹4,60,000 Lowest | 1,250 ₹5,00,000 | 1,299 ₹5,19,600 |
Tender Value
₹46.9 L
EMD Value
₹94,000
Closing Date
12 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY ELECTRIC SUPPLY
GE UTILITY ELECTRIC SUPPLY DELHI CANTT-10
SPECIAL REPAIR TO OLD VINTAGE LT CABLES AT 505 ABW ME LINE AND 5 SIKHLI IN THE AREA OF AGE U ES NO I UNDER GE U ES DELHI CANTT 10
2025_MES_709743_1
GE ELECT/D-13/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELECTRIC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE UTILITY ELECTRIC SUPPLY
₹94,000
Yes
29 Sept 2025
22 May 2025
14 Jun 2025
22 May 2025
12 Jun 2025
5 Jun 2025
Amount
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes:- Note:- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately under respective items of schedule.
16 Sqmm 4 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
150 Sqmm 3.5 core
185 Sqmm 3.5 core
300 Sqmm 3.5 core
400 Sqmm 3.5 core
Excavation in trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation, laying of cable or pipe (where provided for protection of cable or fixing with poles and stays) and getting out in any type of soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and directed by the Engg-in-Charge.
Returning filling in, Including spreading, levelling, Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by the Engg-in-Charge.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc complete all as specified and directed by Engr-in-Charge. Note : Measurement shall be taken after punning down.
S&F sub class B bricks of size 230mmx115mmx75mm having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by the Engg-in-Charge.
All as per srl item No 6.00 here-in-before but using old bricks complete all as specified and directed by the Engg-in-Charge.
S&F GI Pipe (light grade) bore sizes 50 mm with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah complete all as specified and directed by the Engg-in-Charge.
S&F GI Pipe (light grade) bore sizes 80 mm with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah complete all as specified and directed by the Engg-in-Charge.
Demolition of PCC/Hardstanding/Tarmac above GL for laying of cables complete all as specified and directed by the Engg-in-Charge.
M&L for PCC type C2, 1:3:6 using (40 mm gradded stone aggregate) laid in foundations, mass concrete or similar works complete all as specified and directed by the Engg-in-Charge.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique/manual and necessary machine including HDPE pipe of 50 to 150 mm dia suitable for 0.4 Mpa working pressure/GI Pipe complete all as specified and directed by the Engg-in-Charge.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
Vijay Electricals (BID ID -3320381)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3321323)
MV Engineers And Contractors (BID ID -3315280)
mayur enterprises (BID ID -3321261)
Rajindera Enterprises (BID ID -3319782)
Commercial Traders (BID ID -3317130)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .