Loading…
Loading…
Tender Value
₹7.0 Cr
EMD Value
₹5.0 L
Closing Date
30 Jan 2026, 3:00 pmClosed
Signalling work in connection with Provision of precast/Cast in situ, Sleeper boundary wall, Anti crash barrier, small size underpass in the section of Sr.DEN/II/DLI.
558-Sig-16-M-Tender-1459~NR
558-Sig-16-M-Tender-1459
Open
Works - General
12 Months
Shimla, Himachal Pradesh
₹0
₹5.0 L
30 Jan 2026
6 Jan 2026
16 Jan 2026
A-Signalling work in connection with Provision of precast/Cast in situ,
Supply of single apparatus case steel RE with 'E' type lock and key ward no.42 and handle as per drg. No. RE/S&T/ALD/SK/219/82 with (Alt A) and 221/82 with Alt.B. Inspection: RITES.
Casting, concreting and curing of foundation and erection of single apparatus cases of size (1160mmx760mm) at surface and 650mm deep as per approved Drg.No.NR/S&T/CON/2-7/97. 2 A layer of 3 mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All material such as cement, coarse sand, aggregate and anchor bolt shall be supplied by contractor. Apparatus Case single will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. Inspection: Site Engineer.
Preparation of App. Case single not involving wiring of relays. Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal and fixing and jamming of cables with 2-inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on 3 location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from outside as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specification, non-deteriorating type HRC fuses with bases, catenary wires , nuts and bolts and other items shall be supplied by the contractor. ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer.
Preparation of Apparatus Case single involving wiring of relays. Preparation & fixing of bakelite hylum sheet 910x800x6mm and backelite shelf 900x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, Q series relays and other type relays on square bars fixing and jamming of cables with 2-inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable 4 through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specn., non deteriorating type HRC fuses with bases, catenary wires , nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer.
Casting, concreting and curing of foundation and erection of half apparatus cases of size (670mmx760mm) and 650mm deep as per Drg.No.NR/S&T/CON/2. 8/97. A layer of 3 mm of 5 bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All material such as cement, coarse sand, aggregate and anchor bolt shall be supplied by contractor . App. Case half will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. Inspection: Site Engineer.
Supply of apparatus case steel RE half with E type lock and key ward no.42 and handle as per drg.no. RE/S&T/ALD/SK/220/82 and 221/82 with Alt.B. Inspection: RITES.
Preparation of Apparatus Case (location box) half involving wiring of relays. Preparation and fixing of bakelite hylum sheet 450x800x6mm and Backelite shelf 450x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location box secured by nuts and bolts. This includes fixing of fuse ARA terminal, Q series relays and other type of relays on square bars, fixing and jamming of cable with 2-inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately 7 for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. Wiring description for terminal drawing of circuits, inside app. Case. Painting from outside as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specification, non-deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer.
Preparation of App. Case half not involving wiring of relays. Preparation and fixing of Bakelite hylum sheet 450x800x6mm and Backelite shelf 450x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location box secured by nuts and bolts. This includes fixing of fuse ARA terminal and fixing and jamming of cable with 2-inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the 8 hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from outside as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specification, non-deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer.
Supply and installation of earth electrodes as per std. practice. The item includes 9 digging of pit in earth, 3 Mtrs. deep and fixing earth electrode pipe. Casting of cement concrete enclosures as per drg. No. (NR/S&T/CON/6.4/97). The soil treatment shall be done as per std. practice. The item includes provision of mild steel flat of size 35mm x 6mm (as per IRSEM) and nut bolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to block instrument, cable sheath of power equipment, signal base, apparatus case, CT rack / relay racks, other equipment as per the instruction of Engr. at site & IRSEM. Earthing connection location to location shall be done through cable which shall be provided by Railway. Complete materials such as earth electrodes as per drg. No. (NR/S&T/CON/6. 3/97), cement, wiring material, nut bolt for connection & mild steel flat of size 35mm x 6mm or 210 sqm as per SEM etc. to be supplied by the contractor. Inspection: RITES for supply portion, Execution: Site Engineer.
All work of horizontal boring and trenchless cabling along with supply, transportation and insertion of double wall corrugated pipe -( ISI marked) conforming to RDSO Spec no. 10 RDSO/SPN/204/2011, and the laying of cable in the boring under the track / road etc as per instruction of site engg. by using pipe of size 120 mm outer dia, 103.5 mm inner dia in which required number of cables to be crossed. The depth of horizontal boring should be minimum 1.0 m from rail flange/road level. Inspection: RITES for DWC pipe, Execution: Site Engineer.
Laying of signalling/Telecom/power cables of different sizes as per approved Drg. No. NR/S&T/CON/1-1/97A and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables. Inspection: Site Engineer.
Excavating and refilling of trench in Rocky soil to the level of ground with rammed earth as per approved Drg. No.NR/S&T/CON/1-1/97-A1 so as not to form a drain 0.3 Mtrs. Wide & 12 0.5Mtr. Deep on both side of the station alongside the track. This includes 50mm thick concreting work throughout in 1:3:6 ratio. All concreting material to be supplied by the contractor. It shall conform to the safe distance as per signalling and cable plan It also includes clearance of routes of trees & bushes. Inspection: Site Engineer.
Excavating and refilling of trench in Normal Soil to the level of ground with rammed 13 earth as per approved Drg. No.NR/S&T/CON/1-1/97A. Aso as not to form a drain 0.3 Mtrs. Wide & 1 Mtr. Deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable plan. It also includes clearance of roots of trees & bushes. Inspection: Site Engineer.
Supply and laying of 2nd class bricks in the trench and laying as per approved Drg. No.NR/S&T/CON/1- 1/97A as per instructions of the site Engineer. Inspection: Site Engineer.
Blowing/ Drawing of OFC cable in the HDPE duct by mechanical system. Inspection: Site Engineer.
Laying of HDPE duct in the trenches, including in HDD/Manual Boring and supply pulling of Nylon rope through is at different places as per direction of Engineer in charge/ site 16 Engineer. It includes Supply of HDPE duct outer dia 40mm & inner dia 33mm as per TEC Gr No. G/CDS-08/02 Nov /2004 with latest amendment with end cap to be provided along with the drum at both ends. (RDSO specs No. RDSO/SPN/TC/45/2013 revi 2.0) Payment of this item will be made after laying only. Inspection: RITES for supply portion, Execution- Site engineer.
Testing & meggering of all types of outdoor cables after its laying and termination on 17 both ends under supervision of Railway representative. This also includes preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately. This also include dressing and lacing of cable on both ends. Proforma for testing and material for lacing to be supplied by the contractor. Inspection: Site Engineer.
Supply of ARA Terminal Block 25MM center M6 terminal made of PBT as per IRS spec. No.IRS-S- 75/2006 (Rev.2) & IRS drawing No. SA- 23741A(Alt.4), SA23745(Alt.5), SA-23746 & SA- 23756(Alt.3). Inspection: RDSO
Supply and fixing of G.I. pipe perforated at a distance of 20 CM or less of required 19 length at culverts/ bridges/along the cuttings, suitably concreted at both ends as per drg. No. (NR/S&T/CON/1. 4/97) or at ASM office / other buildings suitably fixing it to the wall and at both ends. G.I. clamps of M.S. flats bolts and nut, to be supplied by the contractor. G.I. pipe 75/80 mm dia, 3mm thick. Inspection: RITES for supply portion, Execution: Site Engineer.
Dismantling of lifting barrier/ gate leaves complete set along with winch, wire rope, 20 boom locking arrangements. All dismantled material to be transported and stacked in the store of SSE/Sig at Delhi or Dy.CMM/SSB store depot at DLI or any other store of northern railway as per consignee. Note: - Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr. Inspection: Site Engineer.
General concrete work in cement, coarse sand and aggregate ratio 1:3:6, work 21 scattered at different places for items not covered in above schedule and fine plastering of top will be done with cement sand ratio of 1:4. Volume of foundation also includes volume of C.I. base, anchor bolts etc. Coarse sand, aggregate 25mm and cement to be supplied by contractor. Inspection: Site Engineer
Supply & Installation of Thermo shrink jointing kit for 6-Quad/4-Quad cable for 22 straight through joints as per specifications, drawings and stipulations of tender documents and as per approved cable route plan at various locations. Jointing kits to be supplied as per RDSO specification IRS:TC 77-2012 (Rev.-3) or latest amendments. Inspection : RDSO for supply portion, Execution: Site Engineer.
Supply & Installation of Thermoshrink jointing kit for 6-Quad cable and PIJF cable for 23 Derivation/ Termination joints at LC Gates/Pump House/different locations as decided by the site Engineer as per IRS: TC-77/2012 (Rev.3) with amendment 1 & 2 or latest. This includes all materials required for joints. Inspection: RDSO for supply portion, Execution: Site Engineer.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender-Doc-1459.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .